Distribution Management System DMS600 ABB August22, 2013 | Slide 2 Aplicaciones en el panorama de la red de potencia Classic SA and SCADA Infrastructure Smart Grid System Functions: Distribution Automation, Substation Automation, SCADA and DMS Power Plants ABB August22, 2013 | Slide 3 Funcionalidades del sistema en la red de potencia Term Description ABB Products DMS Distribution Management System suite of applications to improve reliability and efficiency of distribution grids. MicroSCADAPro DMS 600 SCADA SupervisoryControl and Data Acquisition System Network control system used in control centers and substations MicroSCADA Pro SYS 600 SCADA/DMS Common name used when deployed together MicroSCADAPro SYS 600 / DMS 600 SA Substation Automation suite of products, applications and solutions to protect, monitor and control a substation MicroSCADA Pro SYS 600 RTU560, Relion IEDs AFS Switches DA DistributionAutomation suite of products and applications to monitor, coordinate, and operate distribution components from remote locations RTU560 DIN-rail RTU211 Terminologa ABB August22, 2013 | Slide 4 Distribution Management System Sistema de manejo de distribucin (DMS) es una coleccin de aplicaciones que monitorean y controlan la red eficiente y confiablemente. Acta como un sistema de soporte de decisin para asistir al personal del centro de control y personal de campo con el monitoreo y control del sistema de distriucin de potencia. En general ABB August22, 2013 | Slide 5 Distribution Management System El sistema completo de automatizacinde distribucin requiereque todos los niveles seanintegrados. La representacincompleta de la red que se muestra en el sistemade manejo de distribucin(DMS) requiere datos de las subestaciones y alimentadores. Funciones avanzadas DMS proveenlos mejores resultados cuando los datos de las subestaciones estn totalmenteintegrados al sistema de control de red(NCS). NOP Switch Switch Feeder terminal Primary SA DTU RMU RMU * SA =substation automation, DTU =Distribution Terminal Unit, NOP=Network Operating Point, RMU=Ring Main Unit ABB August22, 2013 | Slide 6 Distribution Management System Beneficios en la operacin de red Acortar las interrupciones de horas a minutos! Mejorar calidad de potencia entregada con medidas en lnea, estimaciones y simulaciones. Obtener una mejor visin de la red completa de distribucin. No hay necesidad de sobredimensionar la red gracias a herramientas eficientes para anlisis de red, incluyendo tambin prdidas de red. Utilizar recursos mas eficientemente con manejo de cuadrillas de campo Reportes de suspensiones e ndices muestran la calidad del servicio as como donde se requiere mejorar la red. ABB August22, 2013 | Slide 7 MicroSCADA Pro DMS 600 MicroSCADA Pro DMS 600 permite el manejo eficiente de las redes. DMS 600 ofrece Red Geografica presentada con mapas de fondo FDIR Localizacin, aislamiento y recuperacin de fallas Reportes de suspensiones y planeamiento SAIDI*, SAIFI* (DES, FES) Anlisis de red Supervisin de redes LV Manejo de cuadrillas de campo, reportes de suspensin Distribution Management System SAIDI * = System Average Interruption Duration Index SAIFI * =System Average Interruption Frequency Index ABB August22, 2013 | Slide 8 MicroSCADA Pro DMS 600 DMS 600 importa los unifilares de estacin del SYS 600 No hay necesidad de entrada doble de datos Herramientas fciles para dibujar alimentadores de MV en el mapa Anlisis constantede conectividad Chequeos de sistema para evitar errores Dos lneas conectadas a un switch Una lnea conectada a cada devanado del transformador Edicinde datos de red ABB August22, 2013 | Slide 9 MicroSCADA Pro DMS 600 Vista rpida de todas las lneas, switches, transformadores, subestaciones, etc. Zooming Panning De-cluttering Mapas en 5 capas Analiza la conectividad de la red y muestra el coloreo dinmico de la red Coloreo inteligentede alimentadores Redes en lazo Partes Des energizadas Red aterrizada Manejo de Topologas ABB August22, 2013 | Slide 10 MicroSCADA Pro DMS 600 Identificar zonas de alimentador o transformador Vista por alimentadores Vista por transformadores primarios Navegacin fcil en redes complejas Diagramas dinmicos Trazas downstream upstream Modo de simulacin Reemplaza los pines en la pared o los mmicos. Manejo de topologas ABB August22, 2013 | Slide 11 MicroSCADA Pro DMS 600 Interfaz de usuario integradas Mens automticos para trazar alimentadores, localizar objetos en el mapa, etc. Datos de red del DMS disponibles en grficos de proceso Maneras fciles para abrir diagramas unifilares y dilogos de control del mapade red del DMS Accesode usuario integrado Entrada nica de datos Los datos del diagrama unifilar son reusables La disposicin, los objetos y la conectividadse usanen el DMS. Integracincon MicroSCADAPro SYS 600 ABB August22, 2013 | Slide 12 MicroSCADA Pro DMS 600 Sistema DMS Distribuido (J errquico) Integracin AMI/AMR con servicios WEB Localizacinm de falla con generacin distribuida Mejoras en seguridad Switches desacoplados y topologa desbalanceada Flujo de carga desbalanceado Operacin y control de islas Generacin en redes de LV es visible con smbolos de subestaciones de MV/LV Nuevas caractersticas en la version 4.4 ABB August22, 2013 | Slide 13 Distribution Management Integracin de Informacin en el DMS Datos del cliente Localizacinde los clientes Reportes de suspensinpor los clientes Medidas de la subestacin(IEDs) Impedanciade falla (reactancia) Corriente de corto circuito Fault indicators Medidas de Corriente y Voltaje IntegracinAMI*/AMR* para manejo de redes de LV Otra informacinexistente puede ser adicionadao importadaa la base de datos abierta del DMS Informacindel sitio, instalaciones, datos de mantenimiento, etc. AMI* =Advanced metering infrastructure AMR* =Automatic meter reading ABB August22, 2013 | Slide 14 Datos AMI/AMR para administracin de red Los medidores modernos AMI/AMR proveen informacin de eventos, permitiendo que las redes protegidas por fusible (LV) sean monitoreadas remotamente El DMS puede combinar informacin AMI/AMR a la informacin topolgica de la red, hacer anlisis y generar alarmas DMS NIS Customer Service CIS AMR SCADA * NIS =Network information system * CIS =Customer information system ABB August22, 2013 | Slide 15 Distribution Management DMS 600 Principales Mdulos de Software DMS Base SCADA Interface Planning Base * TCM =Trouble Call Management Outage Reporting LV Networks Fault Location Restoration Support Automatic restoration Oper. Planning Network Analysis Ext. load modeling Recon- figuration TCM* Pole Database Ext. planning Reliability analysis GPS Support ABB August22, 2013 | Slide 16 MicroSCADA Pro DMS 600 DMS Base incluye: Modelo de red para alimentadores en MV con todas las secciones de lnea y datos de componentes. Varios niveles de mapas de fondo (mapas vectoriales y pixeles) Manejo de la Topologa incluyendo switches controlados manualmente, cortes de lnea, aterrizamientos temporales y generadores temporales Interfaz SCADA para datos en tiempo real Funciones de trazado de red (A. Arriba y A. Abajo) Simulacin de acciones de control Nivel Base del DMS ABB August22, 2013 | Slide 17 Distribution Management Reporte de Suspensiones Permite la creacin de reportes de suspensin por falla o mantenimiento con o sin localizacin de falla. Si la localizacin de falla se incluye, el reporte de suspensiones se integra a la funcin de localizacin. Localizacin de fallas Permite el manejo de fallas, localizacin y simulacin. Soporte a la restauracin Permite junto con la localizacin de fallas el planeamiento del aislamiento y restauracin de fallas. Restauracin automtica Con esta opcin el aislamiento y restauracin de la falla se realiza de manera automtica. (SYS 600 control system requerido) DMS 600 Principales Mdulos ABB August22, 2013 | Slide 18 Distribution Management Anlisis de Red Permite el clculo de flujos de carga y corrientes de corto circuito. As mismo anlisis de fusibles y rels de proteccin, estudios de selectividad y simulaciones de ajustes de proteccin. Modelamiento extendido de carga Permite la estimacin de carga usando medidas on-line y uso de curvas o perfiles de carga. Reconfiguracin Permite la funcin de reconfiguracin que se usa para minimizar prdidas de potencia activa cambiando puntos abiertos en una red radialmente operada DMS 600 Principales Mdulos ABB August22, 2013 | Slide 19 Distribution Management Planeamiento de Operaciones Esta opcin permite crear secuencias de operacin y anlisis de contingencias Redes LV Esta opcin hace posible adicionar redes de baja tensin (LV) con bases de datos y funciones de anlisis separadas. Manejo de llamadas Aplicacin de formulario de datos de contactos de clientes que permite usar los datos recolectados de las llamadas de los clientes en el manejo de suspensiones en el DMS. DMS 600 Principales Mdulos ABB August22, 2013 | Slide 20 MicroSCADA Pro DMS 600 El Planeamiento del nivel base incluye: Documentacin de red, anlisis y planeamiento con administracin de datos no en tiempo real Resultados de planeamiento de red y comparacin de planes alternativos Posibilidad de transferir el plan seleccionado a la base de datos de la red documentada Planeamiento del nivel base ABB August22, 2013 | Slide 21 Distribution Management Redes de baja tensin Opcindel planeamiento e informacinde red (NIP) que incluye las redes de baja tensincon carga de base de datos y anlisis separados. Base de datos de postes Opcindel (NIP) de tener la base de datos de los postes y funciones especiales para administracinde postes con sus lneas elctricas. Planeamiento extendido de red Posibilidadde crear documentos (MS Word) de planeamiento y de importar datos del plan a la base de datos de la red. Anlisis de confiabilidad Clculo de confiabilidadde red (planeada) usando datos de confiabilidadpromedio y parmetros de restauracin. Clculo de indices SAIDI, SAIFI and ASAI +energa no entregada (NDE). DMS 600 Planeamiento de mdulos base ABB August22, 2013 | Slide 22 Distribution Management Soporte GPS Posibilidad de usar datos GPS almacenados (waypoints) en la edicin de red. Posibilidad de crear un archivo de exportacin de datos GPS (.csv) de localizacin de elementos de la red para ser cargados en otro dispositivo p.e. un dispositivo GPS. Uso fuera de lnea con datos de condicin y mantenimiento Recoleccin de datos de condicin y manetenimiento en el campo con una rplica de la base de datos. J erarquas definidas de usuario para condicion de componentes y trabajo de servicio Administracin de trabajos de inspeccin y mantenimiento con definiciones de rea y presentaciones geogrficas. DMS 600 Planning base modules ABB August22, 2013 | Slide 23 Sistema SCADA de Distribution con DMS 600 Necesidades del Cliente Mejorar la confiabilidad de las redes de distribucin en las ciudades de DaNang, Hue, Qui Nhonand & BuonMa Thout Respuesta de ABB Sistema SCADA MicroSCADAPro con DMS 600 y RTUs para subestaciones primarias y secundarias Beneficios al clientes Menos y ms cortas interrupciones de la distribucin de potencia a travs de una supervisin y control superiores Da Nang, Hue, Qui Nhon & Buon Ma Thout (4), Vietnam ABB August22, 2013 | Slide 24 Sistema distribuido DMS Necesidad del Cliente Sistema DMS Centralizado/Distribuido confiable Sistema abierto, conexiones fciles a varios SCADAs, buena integracin horizontal a sistemas externos de informacon grfico y de datos del cliente GIS / NIS Respuesta ABB DMS600 con amplia funcionalidad Estructura Distribuida/Centralizada Interfaces a NIS, SCADA Beneficios del cliente Operacin flexible Mejor visin para el manejo de la red Confiabilidad aumentada del suministro de potencia Curstomer: Fortum Distribution Oy Finland Year of commissioning: 2002-2007, 2009 Energy company Fortum, Finlandia ABB August22, 2013 | Slide 25 MicroSCADA Pro DMS 600 Disminuye las suspensiones Mejora la calidad de la potencia entregada Obtenga la mejor visin de su red de distribucin Evita el sobredimensionamiento de la red Manejo de cuadrillas de campo Reportes completos de suspensiones Sistema de vanguardia DMS