What is t he purpose of Walk- in- F reezer ? What is hold ov er t ime f or Walk- in- F reezer in c ase of pow er f ailure ? What is t he purpose of Walk- in- Cooler ? What does t he name indic at e i.e. Walk- in- Cooler or Walk- in- F reezer ? How t he c apac it y of Walk- in- Cooler is measured ? What are t he c ommon sizes of Walk- in- Cooler / F reezer?

07 In c ase of mains pow er f ailure w hat prec aut ions are t o be t aken t o run t he WIC or WIF ? 08 What are t he c ondit ions w hen Generat or get s aut omat ic ally st art ed t o run t he WIC or WIF ? 09 10 11 What is t he basic purpose of 12 v olt c ar bat t ery ? What is t he f unc t ion of alarm sy st em in WIC & WIF ? What is t he f unc t ion of t emp rec order ?

12 Whic h t y pe of ref rigerant is used in new ly supplied WIC / WIF ? (MPP13A, MPH36A, EUROMON) 13 14 15 16 17 Giv e some inf ormat ion regarding R404A ref rigerant Whic h t y pe of ref rigerant w as used in t he earlier v ersion of WIF ? Giv e some inf ormat ion regarding R502 ref rigerant Whic h oil is rec ommended w it h R404a ref rigerant ? What is t he general int erv al of def rost ing in WIF ?

18 How many t emperat ure sensors c an be c onnec t ed t o T emperat ure Alarm Unit VHA 12/4? 19 20 21 22 23 24 ? 25 Spec if ic at ion of 'CLAUDE LY ONS' aut omat ic v olt age st abilizer. Why is def rost ing nec essary ? St at e probable c ause of pet rol engine st art f ailure. St at e Probable c ourse of Pet rol engine st art f ailure ? Spec if ic at ion of Honda G400 pet rol Engine. Whic h c ondit ions are generally monit ored by AMF panel meant f or Genset What are t he regular c hec ks f or lead ac id bat t ery ? engine lif e w hic h part s of engine require periodic al

26 F or ent ranc ing at t ent ion ? 27

How w e c an measure t he spec if ic grav it y of bat t ery ?

28 29 30 31 32 33 34 35 36 Page

Whic h apparat us is used t o t est t he c ells of bat t ery ? Whic h apparat us is used t o t est t he c ells of bat t ery ? General Maint enanc e f or Diesel Engine T ec hnic al dat a f or lomardine Diesel Engine. Model 9LD561 - 2 L Giv e spec if ic at ion of Compressor used in F ast er WIC.? Giv e spec if ic at ion of c ompressor used in Huurre WIC Giv e spec if ic at ion of c ompressor used in HUURRE W.I.C. What is t he pressost at set t ing in f ast er W.I.C. ? What is t he pressost at set t ing in Huurre WIC ?

01 Ans

02 Ans

03 Ans

04 Ans

05 Ans 06 Ans

W hat i s t he purpos e of W al k-i n-Freezer ? Walk-in-Freezers are used for bulk storage of Polio vaccine at state/regional level at temperatures between -180 C To -200 C Top of Page W hat i s hol d over t i me for W al k-i n-Freezer i n cas e of power fai l ure ? Hold over time is about 4-6 hours in case of power failure Top of Page W hat i s t he purpos e of W al k-i n-Cool er ? Walk-in-coolers are used for bulk storage of vaccines at +40C to +80C Top of Page W hat does t he name i ndi cat e i .e. W al k-i n-Cool er or W al k-i n-Freezer ? The name "Walk-in" is given as one can walk info the storage spaces inside these rooms. Top of Page How t he capaci t y of W al k-i n-Cool er i s meas ured ? Capacity of Walk-in-Cooler is measured in Cu.m. Top of Page W hat are t he common s i zes of W al k-i n-Cool er / Freezer? 16 Cu.M., 20 Cu.m. , 32Cu.m., 40Cu.m.. Top of Page

07 Ans

08 Ans

09 Ans 10 Ans

11 Ans

12 Ans 13 Ans

In cas e of mai ns power fai l ure what precaut i ons are t o be t aken t o run t he W IC or W IF ? Standby Generator has to be made available to run the Walk-in-Cooler or Walk-in-Freezer in case of power failure. Top of Page W hat are t he condi t i ons when Generat or get s aut omat i cal l y s t art ed t o run t he W IC or W IF ? If there is mains power failure or single phasing or low & high voltage. Top of Page W hat i s t he bas i c purpos e of 12 vol t car bat t ery ? To start the generator engine Top of Page W hat i s t he funct i on of al arm s ys t em i n W IC & W IF ? An alarm system is provided to monitor cold / freezer room temperature. It monitors low & high temperature continuously. Top of Page W hat i s t he funct i on of t emp recorder ? The temperature recorder records the cooler / freezer room temperature continuously on a circular chart. Top of Page W hi ch t ype of refri gerant i s us ed i n newl y s uppl i ed W IC / W IF ? (MPP13A, MPH36A, EUROMON) Refrigerant R404A - NON CFC. Top of Page Gi ve s ome i nformat i on regardi ng R404A refri gerant Blend of (R125+R143+R134a) Formula = OHF2CF3 / CF3OH2F / OH3CF3 Boiling point = -46.30C ODP = 0 , GWP= 0.36 Appearance & odour = Colourless liquified gas Packing = 10.9 Kg steel Cylinder. Top of Page W hi ch t ype of refri gerant was us ed i n t he earl i er vers i on of W IF ?

14

Ans 15 Ans

Refrigerant R502. Top of Page Gi ve s ome i nformat i on regardi ng R502 refri gerant Azeotrope Blend of R22 + R115 R502 = R22 = 49 % & R 115 = 51 % This is low temperature refrigerant Boiling point = -45.60C ODP = 0.18 , GWP = 3.8- 4. Top of Page W hi ch oi l i s recommended wi t h R404a refri gerant ? Mobil EALTM Arctic 46 , Polyolester lubricant. Top of Page W hat i s t he general i nt erval of defros t i ng i n W IF ? In WIF general interval of defrosting is 12 hrs. Top of Page How many t emperat ure s ens ors can be connect ed t o Temperat ure Al arm Uni t VHA 12/4? Four temperature sensor can be connected to VHA 12/4 -1 Alarm unit.. Top of Page Speci fi cat i on of 'CLAUDE LY ONS' aut omat i c vol t age s t abi l i zer. Type : TS - 2.5/3 X S1782 Input : 300 - 414V, 47- 65 Hz; Output : 380 / 220 +; nbsp; + 0.5 % 3 X 13 A 8.6 KVA Top of Page W hy i s defros t i ng neces s ary ? The moisture in the air inside the cold room gets frozen & forms frost on the evaporator coils of the units. For better cooling efficiency.it is to be melted at regular time intervals. Top of Page St at e probabl e caus e of pet rol engi ne s t art fai l ure. 1. No. Fuel in the tank

16 Ans 17 Ans 18 Ans

19 Ans

20 Ans

21 Ans

2. 3. 4. 5. 6. 22 Ans

Fuel Valve closed Choke is not working Fuel overflow in carburetor. Dirty spark plug. Low battery

23 Ans

24 Ans

25 Ans

Top of Page Speci fi cat i on of Honda G400 pet rol Engi ne. Engine oil capacity - 1.2 kg Spark - plug gap - 0.6 mm to 0.7 mm Valve clearance inlet - 0.06 to 0.12 mm Exhaust - 0.09 to 0.15 mm Engine oil - SAE10W - 40 (depending on ambient temperature) R.P.M. = 3000 H.P. = 10 Top of Page Speci fi cat i on of Honda G400 pet rol Engi ne. 1. Engine failure 2. Too low lube oil pressure 3. Too High Engine temperature 4. Phase reversal. 5. Runaway speed of Engine. 6. Maintenance hours . 7. Overloading of Engine Top of Page W hi ch condi t i ons are general l y moni t ored by AMF panel meant for Gens et ? 1. Engine failure 2. Too low lube oil pressure 3. Too High Engine temperature 4. Phase reversal. 5. Runaway speed of Engine. 6. Maintenance hours . 7. Overloading of Engine Top of Page W hat are t he regul ar checks for l ead aci d bat t ery ? Battery specific gravity Battery acid level Battery terminal / pole connection Battery firm on frame Top of Page

26 Ans

For ent ranci ng engi ne l i fe whi ch part s of engi ne requi re peri odi cal at t ent i on ? Engine oil filter Air filter Fuel filter * Check oil level by the dipstick daily. Top of Page How we can meas ure t he s peci fi c gravi t y of bat t ery? Using hydrometer. Top of Page W hi ch apparat us i s us ed t o t es t t he cel l s of bat t ery? Cell- tester Top of Page W hi ch apparat us i s us ed t o t es t t he cel l s of bat t ery ? Maximum H.P = 11, R.P.M. = 3600 Fuel consumption = 200-210 Hrs/100-hrs. Fuel tank capacity = 5 ltrs. Oil sump capacity = 1.8 ltrs. Engine oil = SAE 10-40 Compression ratio = 17.5 : 1. Top of Page General Mai nt enance for Di es el Engi ne 1. Engine oil level check 2. Engine oil change 3. Air cleaner element check 4. Air cleaner element cleaning 5. Fuel filter cleaning 6. Injector nozzle checking & cleaning . 7. Valve clearance check & adjust. 8. Combustion chamber cleaning 9. Fuel tank & fuel line cleaning. Top of Page Techni cal dat a for l omardi ne Di es el Engi ne. Model 9LD561 - 2 L No. of Cylinders - 2 Bore - 90 mm, stroke - 88 mm Compression ratio - 17.2 : 1 RPM - 1500 , Min. idling speed - 1000 - 1100 RPM,

27 Ans 28 Ans 29 Ans

30 Ans

31 Ans

Oil sump capacity = 3.05 kg, H.P. = 8, Valve clearance - Inlet - 0.20 mm (Cold Engine) Exhaust - 0.20 mm Fuel tank capacity = 10 ltr. Engine oil grade = SAE 10W / 40 (Depends on ambient temperature) 32 Ans Top of Page Gi ve s peci fi cat i on of Compres s or us ed i n Fas t er W IC.? L'UNITE - CAJ4511A In = 5.3A, Id = 25A, 220V - 240V, 50Hz. 1220VA (975W) Top of Page Gi ve s peci fi cat i on of compres s or us ed i n Huurre W IC ASPERA : J6226M Input power = approx. 1 KW. Resistance (ph-ph) = 14.38 Start current = 13A, Run current = approx .2A Top of Page Gi ve s peci fi cat i on of compres s or us ed i n HUURRE W .I.C. L'UNITE : TAJ 4511A 340-420V, 50Hz, 3ph Winding resistance (1,2,3)= 14.5 each. In = 1.9A Top of Page W hat i s t he pres s os t at s et t i ng i n fas t er W .I.C. ? Following are the set limits of HP/LP switch. HP . 300 psi LP 25 psi ----------Cut off just above vaccum, ----------------------------------Cut on at about Differential - 25 psi Top of Page W hat i s t he pres s os t at s et t i ng i n Huurre W IC ? Following are the set limits of HP / LP switch L.P. = 2.0 bar - variable / adjustable H.P. = 12.0 bar At this setting unit will run L.P. = 0.1 bar H.P. = 16.0 - Variable /adjustable

33 Ans

34 Ans

35 Ans

36 Ans

At this setting and will trip off Differential setting L.P. = 1.0 bar H.P. = 3.6 bar Setting for condenser fan H.P. = 9.0 bar fan on (low)H.P. = 7.0 bar fan off Differential = 2.0 bar Top of Page