Escolar Documentos
Profissional Documentos
Cultura Documentos
Villa SantAngelo: alteration of the original structural configuration: wooden tie, originally well connected to the external wall by means of an iron device, has been cutted during an heavy refurbishment
Villa SantAngelo: the R.C. roof implied the masonry walls collapse.
San Demetrio: typical cracks in the masonry lintel above the opening
Castelnuovo: total collapse due to poor masonry quality Villa SantAngelo: collapse due to the trasversal connections lack
DAMAGES OVERTURNING
DAMAGES OVERTURNING
DAMAGES OVERTURNING
DAMAGES OVERTURNING
DAMAGES OVERTURNING
TIES
TIES
RC TIE BEAMS
RC TIE BEAMS
In-plane mechanisms
DAMAGES In plane Shear Diagonal Cracks on the masonry walls INTERVENTIONS To increase the mechanical characteristics of masonry panels 1. Steel or Glass Fiber Reinforced plaster 2. Iniections
In-plane mechanisms
DAMAGES In plane Shear Diagonal Cracks on the masonry walls INTERVENTIONS To increase the mechanical characteristics of masonry panels 1. Steel or Glass Fiber Reinforced plaster 2. Iniections
In-plane mechanisms
DAMAGES In plane Shear Diagonal Cracks on the masonry walls INTERVENTIONS To increase the mechanical characteristics of masonry panels 1. Steel or Glass Fiber Reinforced plaster 2. Iniections
In-plane mechanisms
DAMAGES In plane Shear Diagonal Cracks on the masonry walls INTERVENTIONS To increase the mechanical characteristics of masonry panels 1. Steel or Glass Fiber Reinforced plaster 2. Iniections
In-plane mechanisms
DAMAGES In plane Shear Diagonal Cracks on the masonry walls INTERVENTIONS To increase the mechanical characteristics of masonry panels 1. Steel or Glass Fiber Reinforced plaster 2. Iniections
In-plane mechanisms
Localized Steel or Glass Fiber Reinforced plaster
In-plane mechanisms
Diffused Steel or Glass Fiber Reinforced plaster
l a b lo
al n A
s i s ysi
!! ! ! ! !! ! d e d e ne
Case studies to assess the feasibilityof surveys activity and retrofit interventions on historical centers Case studies to point out detailed retrofit programs of historical centers Monitoring activities cultural heritage on
LAQUILA NAVELLI
METHODOLOGY OF STUDY
1. ARCHITECTURAL SURVEY 2. STUDY OF MASONRY AND BUILDINGS
AGGREGATE
ARCHITECTURAL
4. DAMAGE AND CRACKS ANALYSIS 5. IN SITU TESTS 6. SEISMIC ANALYSIS 7. RETROFIT INTERVENTIONS 8. STRUCTURAL CAPACITY INCREASE
DEFINITION OF GUIDELINES FOR THE SURVEY, ANALYSIS AND RETROFIT INTERVENTIONS ON MASONRY BUILDINGS AGGREGATE IN SEISMIC ZONES
LEVEL 0
3
LEVEL 1
STRUCTURAL SURVEY
BRICK MASONRY
THIN VAULT
THIN VAULT
THIN VAULT
CLOISTER VAULT
BARREL VAULT
BARREL VAULT
IN SITU TESTS
FLAT JACKS stress in the masonry SINGLE: DOUBLE: elastic properties
INTERVENTIONS
OUT OF PLANE MECHANISMS: Facades Overturnng
VERTICAL MEMBERS
INSERTION OF TIES
INTERVENTIONS
SHEAR CRACKS
VERTICAL MEMBERS
INJECTIONS
INTERVENTIONS
CRACKS AND PARTIAL OR TOTAL FLOOR SLABS COLLAPSE
FLOOR SLABS
INTERVENTIONS
CRACKS OR PARTIAL COLLAPSE OF VAULTS
FLOOR SLABS