Você está na página 1de 55

TABELA I.

Sample Size Code Letters


Special inspection levels
Lot or batch size

General inspection levels

S-1

S-2

S-3

S-4

I
+ leve

II

III +
rgido

2
9
16

to
to
to

8
15
25

A
A
A

A
A
A

A
A
B

A
A
B

A
A
B

A
B
C

B
C
D

26
51
91

to
to
to

50
90
150

A
B
B

B
B
B

B
C
C

C
C
D

C
C
D

D
E
F

E
F
G

151
281
501

to
to
to

280
500
1200

B
B
C

C
C
C

D
D
E

E
E
F

E
F
G

G
H
J

H
J
K

1201
3201
10001

to
to
to

3200
10000
35000

C
C
C

D
D
D

E
F
F

G
G
H

H
J
K

K
L
M

L
M
N

35001
150001
500001

to
to
to

150000
500000
over

D
D
D

E
E
E

G
G
H

J
J
K

L
M
N

N
P
Q

P
Q
R

TABELA 5. Single Sampling Plans for Normal Inspection (Master Table)


Sample
Size Sample
0.010 0.015 0.025 0.040 0.065
size Ac
Code
Ac
Ac
Ac
Ac
Rc
Rc
Rc
Rc
Rc
Letter
A
2
B
3
C
5
8
D
E
13
F
20
G
32
H
J
K

50
80
125

L
M
N

200
315
500

P
Q

800
1250

2000

Acceptable Quality Levers (normal inspection)


0.10

Ac
Rc

0.15

Ac
Rc

0.25

Ac
Rc

0.40

Ac
Rc

0.65

Ac
Rc

2.5

0 1

Ac
Rc

4.0

Ac
Rc

6.5

Ac
Rc

10

Ac
Rc

15

0 1

Ac
Rc

25

250

5 6

7 8

10 11 14 15 21 22

5 6 7 8 10 11 14 15 21 22 30 31 44 45
7 8 10 11 14 15 21 22
10 11 14 15 21 22

5 6 7 8 10 11 14 15 21 22
7 8 10 11 14 15 21 22
10 11 14 15 21 22

3 4
5 6
7 8

5 6 7 8 10 11 14 15 21 22
7 8 10 11 14 15 21 22
10 11 14 15 21 22

650

Ac
Rc

5 6 7 8 10 11 14 15 21 22 30 31
7 8 10 11 14 15 21 22 30 31 44 45
10 11 14 15 21 22 30 31 44 45

3 4
5 6
7 8

2 3
3 4
5 6

Ac
Rc

3 4

2 3
3 4
5 6

1 2

400

Ac
Rc

3 4
5 6
7 8

3 4
5 6
7 8

5 6 7 8 10 11 14 15 21 22
7 8 10 11 14 15 21 22
10 11 14 15 21 22

150

Ac
Rc

2 3

2 3
3 4
5 6

3 4
5 6
7 8

100

Ac
Rc

1 2
2 3

1 2
2 3

2 3
3 4
5 6

65

2 3
3 4
5 6

1 2

1 2

Ac
Rc

1 2

1 2
2 3
3 4

1 2
2 3

40

1 2

1 2
2 3
3 4

1 2
2 3
3 4

Ac
Rc

1 2
2 3
3 4

1 2
2 3

0 1

0 1

1 2
1 2 2 3

Ac
Rc

0 1

0 1

0 1

1.5

0 1

0 1

1 2
2 3
3 4

Ac
Rc

0 1

0 1

0 1

1.0

0 1

0 1

0 1

Ac
Rc

1000

Ac
Rc

30 31
44 45

TABELA 6. Single Sampling Plans for Tightened Inspection (Master Table)


Sample
Size
Sample
Code
0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Ac
Letter
Rc
Rc
Rc
Rc
Rc
A

13

20

32

50

80

125

200

315

500

800

1250

2000

3150

Acceptable Quality Levers (tightened inspection)


0.10

Ac
Rc

0.15

Ac
Rc

0.25

Ac
Rc

0.40
Ac

Rc

0.65
Ac

Rc

1.0
Ac

Rc

1.5
Ac

Rc

2.5
Ac

Rc

4.0
Ac

Rc

6.5
Ac

Rc

01
01
0 1
0 1

1 2

0 1

1 2

2 3

1 2

2 3

3 4

1 2

2 3

3 4

5 6

1 2

2 3

3 4

5 6

8 9

1 2

2 3

3 4

5 6

8 9

12 13

1 2

2 3

3 4

5 6

8 9

12 13

18 19

1 2

2 3

3 4

5 6

8 9

12 13

18 19

18 19

0 1
0 1
0 1
0 1
0 1
0 1
0 1

1 2

2 3

3 4

5 6

8 9

12 13

1 2

2 3

3 4

5 6

8 9

12 13

18 19

1 2

2 3

3 4

5 6

8 9

12 13

18 19

2 3

3 4

5 6

8 9

12 13

18 19

0 1
0 1
01

1 2
1 2

evers (tightened inspection)


10
Ac

15
Rc

Ac

25
Rc

Ac

40
Rc

Ac

Rc

65
Ac

Rc

100
Ac

150

Rc Ac

Rc

250
Ac

Rc

400
Ac

Rc

1000
Ac

Rc

1 2

2 3

3 4

5 6

8 9

12 13

18 19

27 29

1 2

2 3

3 4

5 6

8 9

12 13

18 19

27 29

41 42

41 42

1 2

2 3

3 4

5 6

8 9

12 13

18 19

27 29

1 2

2 3

3 4

5 6

8 9

12 13

18 19

27 29

41 42

2 3

3 4

5 6

8 9

12 13

18 19

27 29

41 42

3 4

5 6

8 9

12 13

18 19

5 6

8 9

12 13

18 19

8 9

12 13

18 19

12 13

18 19

18 19

650

Rc Ac

TABELA 7. Single Sampling Plans for Reduced Inspection (Master Table)


Sample
Size
Sample 0.010
Code
Ac
Rc
Letter

2
2
2

13

20

32

50

A
B

80

125

200

315

500

800

Acceptable Quality Levers (reduced inspection)


0.015
Ac

Rc

0.025
Ac

Rc

0.040
Ac

Rc

0.065
Ac

Rc

0.10
Ac

Rc

0.15
Ac

Rc

0.25
Ac

Rc

0.40
Ac

Rc

0.65
Ac

Rc

1.0
Ac

Rc

1.5
Ac

Rc

2.5
Ac

Rc

4.0
Ac

Rc

0 1
0 1
0 1
0 1

0 2

0 1
0 1
0 1
0 1
0 1

0 2

0 1

0 2
0 2

1 3

1 3

1 4

0 2

1 3

1 4

2 5

1 3

1 4

2 5

3 6

1 4

3 6

5 8

0 2

2 5

3 6

5 8

7 10

1 3

3 6

5 8

7 10

10 13

0 2

1 3

1 4

5 3

5 8

7 10

10 13

0 2

1 3

1 4

2 5

7 10

10 13

1 3

1 4
2 5

2 5
3 6

3 6

5 8
7 10

7 10
10 13

10 13

0 1
0 1

1 3

0 2

0 2

0 1

0 1

0 2

1 4

5 8

y Levers (reduced inspection)


6.5
Ac

Rc

10
Ac

15
Rc

Ac

25
Rc

0 1

Ac

40
Rc

Ac

65
Rc

Ac

100
Rc

Ac

Rc

150
Ac

Rc

250
Ac

Rc

400
Ac

Rc

650
Ac

Rc

Ac

Rc

1 2

2 3

3 4

5 6

7 8

10 11

14 15

21 22

30 31
30 31

0 2

1 3

2 4

3 5

5 6

7 8

10 11

14 15

21 22

0 2

1 3

1 4

2 5

3 6

5 8

7 10

10 13

14 17

21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10

10 13

14 17

21 24

1 3

1 4

2 5

3 6

5 8

7 10

10 13

14 17

21 24

1 4

2 5

3 6

5 8

7 10

10 13

2 5

3 6

5 8

7 10

10 13

3 6

5 8

7 10

10 13

5 8

7 10

10 13

7 10

10 13

10 13

1000

TABELA 8. Double Sampling Plans for Normal Inspection (Master Table)

Sample
Size Code Sample
Letter

A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R

First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second

Sample
Size

Acceptable Quality levels (reduced


Correlati
ve
0.010 0.015 0.025 0.040 0.065
0.10
0.15
0.25
0.40
0.65
1.0
Sample
Size Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc

2
4
3
6
5
10
8
16

5
5
8

8
13
13

13

20

20

32

32

50

50

80

80

125
125
200 200
315 315
500 500

.
.
.
26

20
40
32
64
50
100
80
160
125
250
200
400
315
630
500
1000

.
.

.
.
.

.
.
0 2
1 2

0 2
1 2
0 3
3 4

0 2
1 2
0 3
3 4
1 4
4 5

0
1
0
3
1
4
2
6

2
2
3
4
4
5
5
7

0 2
1 2
0 3
3 4
1 4
4 5
2 5
6 7
3 7
8 9

0 2
1 2
0 2 0 3
1 2 3 4
0 2
0 3 31 4
1 2
4
4 5
0 2 0 3 31 4
2 5
1 2 4
4 5
6 7
0 3 31 4 42 5
3 7
4
5
6 7
8 9
1 4
2 5
3 7
5 9
4 5
6 7
8 9
12 13
2 5 3 7
5 9
7 11
6 7 8 9
12 13 18 19
3 7
5 9
7 11
11 16
8 9
12 13 18 19 26 27
5 9
7 11
11 16
12 13 18 19 26 27

Acceptable Quality levels (reduced inspection)


1.5
2.5
4.0
6.5
10

15

25

Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc
.
.
0 2
0 3
.
1 2
3 4
0 2
0 3
1 4 4
.
1 2
3 4
5
.
0 2
0 3
1 4
2 5
1 2
3 4
4 5
6 7
0 2
0 3
1 4
2 5
3 7
1 2
3 4
4 5 6 7
8 9
0 2
0 3
1 4
2 5 3 7
5 9
1 2
3 4
4 5
6 7 8 9
12 13
0 2
0 3
1 4
2 5
3 7 5 9
7 11
1 2
3 4
4 5
6 7
8 9 12 13 18 19
0 3
1 4
2 5
3 7
5 9
7 11
11 16
3 4
4 5
6 7
8 9
12 13 18 19 26 27
1 4
2 5
3 7
5 9
7 11 11 16
4 5
6 7
8 9
12 13 18 19 26 27
2 5
3 7
5 9
7 11
11 16
6 7
8 9
12 1 3 18 19 26 27
3 7
5 9
7 11
11 16
8 9
12 13 18 19 16 17
5 9
7 11
11 16
12 13 18 19 16 17
7 11
11 16
18 19 26 27
11 16
26 2 7

40

65

100

150

250

400

650

1000

Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc Ac Rc
.
.
.
.
.
.
.
.
1 4
2 5
3 7
5 9 7 11 11 16 17 22 25 31
4 5
6 7
8 9
12 13 18 19 26 27 37 38 56 57
2 5
3 7
5 9
7 11
11 16 17 22 25 31
6 7
8 9
12 13 18 19 26 27 37 38 56 57
3 7
5 9
7 11
11 16 17 22 25 31
8 9
12 13 18 19 26 27 37 38 56 57
5 9
7 11
11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57
7 11
11 16
18 19 26 27
11 16
26 27

TABELA 9. Double Sampling Plans for Tightened Inspection (Master Table)


Sample
Size
Code
Letter

A
B

C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S

Sample

First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second

Sample
Size

2
2
3
3
5
5
8
8
13
13
20
20
32
32
50
50
80
80
125
125
200
200
315
315
500
500
800
800
1250
1250
2000
2000

Correlative
Sample Ac0.010 Ac0.015 Ac0.025 Ac0.040 Ac0.065
Size
Rc
Rc
Rc
Rc
Rc

2
4
3
6
5
10
8
16
11
26
20
40
32
64
50
100
80
160
125
250
200
400
315
630
500
1000
800
1600
1250
2500
2000
4000

Acceptable Quality Levers (tightene


0.10

Ac
Rc

0.15

Ac
Rc

0.25

Ac
Rc

0.40

Ac
Rc

0.65

Ac
Rc

Ac
Rc

1.0

Ac
Rc

1.5

.
.
.
.
.
.
.
.
.
.
.
.

0
1
0
1

2
2

0
1
2 0
2 3

2
2
3
4

0
1
0
3
1
4

2
2
3
4
4
5

0
1
0
3
1
4
2
6

2
2
3
4
4
5
5
7

0
1
0
3
1
4
2
6
3
11

2
2
3
4
4
5
5
7
7
12

0
1
0
3
1
4
2
6
3
11
6
15

2
2
3
4
4
5
5
7
7
12
10
16

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

ptable Quality Levers (tightened inspection)


Ac
Rc

2.5

Ac
Rc

4.0

Ac
Rc

6.5

Ac
Rc

10

Ac
Rc

15

Ac
Rc

25

Ac
Rc

40

Ac
Rc

65

.
.
.
.

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
1
0
3
1
4
2
6
3
11
6
15
9
23

2
2
3
4
4
5
5
7
7
12
10
16
11
24

0
3
1
4
2
6
3
11
6
15
9
23

100

Ac
Rc

.
3
4
4
5
5
7
7
12
10
16
11
24

1
4
2
6
3
11
6
15
9
23

150

Ac
Rc

.
4
5
5
7
7
12
10
16
11
24

2
6
3
11
6
15
9
23

250

Ac
Rc

.
5
7
7
12
10
16
11
24

3
11
6
15
9
23
15
14

400

Ac
Rc

.
7
12
10
16
11
24
20
35

6
15
9
23
15
14
23
32

650

Ac
Rc

.
10
16
11
24
20
35
29
53

9
23
15
14
23
32

.
11
24
20
35
29
53

15
14
23
32

1000

Ac
Rc

.
20 23 29
35 32 53
29
53

TABELA 10. Double Sampling Plans for Reduced Inspection (Master Table)
Sample
Size
Code
Letter

Sample

Sample
Size

Correlati
ve
Sample 0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Size Ac
Rc
Rc
Rc
Rc
Rc

Acceptable Quality Levers (tighten


0.10
Ac
Rc

0.15
Ac
Rc

0.25
Ac
Rc

0.40
Ac
Rc

0.65
Ac

Rc

1.0
Ac

1.5

Rc

Ac

Rc

A
B
C

D
E
F
G
H
J
K
L
M
N
P
Q
R

First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second
First
Second

2
2
3
3
5
5
8
8
13
13
20
20
32
32
50
50
80
80
125
125
200
200
315
315
500
500

2
4
3
6
5
10
8
16
13
26
30
40
32
64
50
100
80
160
125
250
200
400
315
630
500
1000

.
.
.
.
.
.

2 0

2 0

2 0

3 0

2 0

4 1

2 0

3 0

4 0

.
.
.

2 0

4 1

5 3

2 0

3 0

4 0

4 1

2 0

4 1

5 3

6 4

8 12

2 0

3 0

4 0

4 1

5 2

5 10

2 0

4 1

5 3

6 4

7 6

8 12

12 16

2 0

3 0

4 0

4 1

5 2

7 3

5 10

2 0

4 1

5 3

6 4

7 6

8 12

12 16

2 0

3 0

4 0

4 1

5 2

7 3

5 10

2 0

4 1

5 3

6 4

7 6

7 8 12

12 16

.
.
.

cceptable Quality Levers (tightened inspection)


2.5
Ac

4.0

Rc

Ac

6.5

Rc

Ac

10

Rc

Ac

15
Rc

Ac

25
Rc

Ac

.
.
.

Rc

Ac

.
.
.

.
.

40

65
Rc

Ac

.
.
.

100
Rc

Ac

Rc

.
.
.

8 12

5 10 7 12
12 16 18 22

8 12

5 10

8 12

12 16

5 10

8 12

12 16

5 10

8 12

12 16

5 10

8 12

12 16

5 10

8 12

12 16

5 10

8 12

12 16

5 10

8 12

12 16

12 16

Rc

.
.
.

5 10

Ac

.
.
.

150

250
Ac

Rc

.
.
.

5 10 7 12
12 16 18 22
11 17
26 30

400
Ac
Rc

650
Ac
Rc

.
.
.
11 17
26 30

1000
Ac
Rc

.
.
.

.
.

TABELA 11. Multiple Sampling Plans for Normal Inspection (Master Table)
Sample
Size
Code
Letter

Sample

Correlati
Sample
ve
Size
Sample 0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Size Ac
Rc

Rc

Rc

Rc

Rc

Acceptable Quality Levers (norm


0.10
Ac
Rc

0.15
Ac
Rc

0.25
Ac
Rc

0.40
Ac
Rc

0.65
Ac
Rc

1.0
Ac
Rc

1.5
Ac
Rc

2.5
Ac
Rc

A
B
C

First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13
20
20
20
20
20
20
20

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
63
78
91
20
40
60
80
100
120
140

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

2
2
2
3
3

1 3
2 3

2
0
0
0
1
2
3
4

3
2
3
3
4
4
5
5

2
0
0
0
1
2
3
4
0
0
1
2
3
4
6

3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

2
0
0
0
1
2
3
4
0
0
1
2
3
4
6
0
1
2
3
5
7
9

3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
4
5
6
7
8
9
10

eptable Quality Levers (normal inspection)


4.0
Ac

Rc

6.5
Ac

Rc

Ac

15
Rc

.
0
0
0
0
1

2
2
2
3
3

1 3
0
0
0
0
1

10

2
2
2
3
3

1 3
2 3
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14

2 3
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19

++
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26

Ac

25
Rc

++
++
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac

Rc

++
++
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54

40
Ac

Rc

++
++
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54
6 16
17 27
29 39
40 49
53 54
65 66
77 78

65
Ac

Rc

++
++
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54
6 16
17 27
29 39
40 49
53 54
65 66
77 78

100
Ac

Rc

++
++
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54
6 16
17 27
29 39
40 49
53 54
65 66
77 78

150
Ac

Rc

++
++
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54
6 16
17 27
29 39
40 49
53 54
65 66
77 78

250
Ac

Rc

400
Ac

Rc

++
++
++
++
4 12
6 16
11 19 17 27
19 27
29 39
27 34
40 49
36 40
53 54
45 47
65 66
53 54
77 78
6 16
17 27
29 39
40 49
53 54
65 66
77 78

650
Ac
Rc

1000
Ac
Rc

++
++

++

TABELA 12. Multiple Sampling Plans for Normal Inspection (Master Table) (continued)
Sample
Size
Code
Letter

Sample

First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh

Correla
Sample
tive
Size Sample 0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Ac
Size Rc
Rc
Rc
Rc
Rc
32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315
500
500
500
500
500
500
500

32
64
98
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2215
500
1000
1500
2000
2500
3000
3500

Acceptable Quality Levers (normal inspection


0.10

Ac
Rc

0.15

Ac
Rc

0.25

Ac
Rc

0.40

Ac
Rc

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

2
2
2
3
3

1 3
.

0
0
0
0
1

1 3

0
0
0
0
1

2
2
2
3
3

1 3
.

2
2
2
3
3

0
0
0
0
1

2
2
2
3
3

1 3
2 3

2
0
0
0
1
2
3
4

3
2
3
3
4
4
5
5

2
0
0
0
1
2
3
4
0
0
1
2
3
4
6

3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

2
0
0
0
1
2
3
4
0
0
1
2
3
4
6
0
1
2
3
5
7
9

3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
4
5
6
7
8
9
10

2 3
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14

2 3
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19

2 3
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26

0.65

Ac
Rc

0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac
Rc

1.0

0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac
Rc

1.5

0 4
1 5
2 6
3 7
5 8
7 9
4 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac
Rc

2.5

0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

cceptable Quality Levers (normal inspection)


Ac
Rc

4.0

0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac
Rc

6.5

1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac
Rc

10

2 9
7 14
13 19
19 25
25 29
31 33
37 38

Ac
Rc

15

Ac
Rc

25

Ac
Rc

40

Ac
Rc

65

100

Ac
Rc

150

Ac
Rc

250

Ac
Rc

400

Ac
Rc

650

Ac
Rc

1000

Ac
Rc

TABELA 13. Multiple Sampling Plans for Tightened Inspection (Master Table)
Sam
ple
Size
Cod
e
A
B
C

Sample

Correl
Sample ative
Size
Sampl 0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Ac
e Size Rc
Rc
Rc
Rc
Rc

Acceptable Quality Levers (tightened inspe


0.10

Ac
Rc

0.15

Ac
Rc

0.25

Ac
Rc

0.40

Ac
Rc

0.65

Ac
Rc

Ac
Rc

1.0

Ac
Rc

1.5

Ac
Rc

2.5

Ac
Rc

4.0

.
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13
20
20
20
20
20
20
20

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
63
78
91
20
40
60
80
100
120
140

0
0
0
0
1
1
2

2
2
2
3
3
3
3

0
0
0
0
1
1
2
0
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

0
0
0
0
1
1
2
0
0
0
1
2
3
4
0
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

0
0
0
0
1
1
2
0
0
0
1
2
3
4
0
0
1
2
3
4
6
0
1
2
3
5
7
9

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
4
5
6
7
8
9
10

ty Levers (tightened inspection)


Ac
Rc

6.5

Ac
Rc

10

Ac
Rc

15

.
0 2
0 2
0 2
0 3
1 3
1 3
2 3
0 2 0 2
0 2 0 3
0 2 0 3
0 3 1 4
1 3 2 4
1 3 3 5
2 3 4 5
0 2 0 3
0 3 0 3
0 3 1 4
1 4 2 5
2 4 3 6
3 5 4 6
4 5 6 7
0 3 0 4
0 3 1 5
1 4 2 6
2 5 3 7
3 6 5 8
4 6 7 9
6 7 9 10
0 4 0 4
1 5 2 7
2 6 4 9
3 7 6 11
5 8 9 12
7 9 12 14
9 10 14 15
0 4 0 6
2 7 3 9
4 9 7 12
6 11 10 15
9 12 16 17
12 14 18 20
14 15 21 22

*
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33

Ac
Rc

25

Ac
Rc

40

*
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49

*
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

65

100

Ac
Rc

150

Ac
Rc

250

Ac
Rc

400

Ac
Rc

650

Ac
Rc

.
*

.
*

.
*

.
*

.
*

.
*

*
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

*
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

*
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

*
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

*
6 15
16 25
25 36
37 66
49 55
61 64
72 73

1000

Ac
Rc

.
*

TABELA 14. Multiple Sampling Plans for Tightened Inspection (Master Table) (continued)
Sampl
Correlat
e Size
Sample
ive
Sample
Code
Size Sample 0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Ac
Letter
Size Rc
Rc
Rc
Rc
Rc
K

First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh

32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315
500
500
500
500
500
500
500
800
800
800
800
800
800
800

32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2205
500
1000
1500
2000
2500
3000
3500
800
1600
2400
3200
4000
4800
5600

Acceptable Quality Levers (tightened inspecti


0.10

Ac
Rc

0.15

Ac
Rc

0.25

Ac
Rc

0.40

Ac
Rc

0
0
0
0
1
1
2
0
0
0
0
1
1
2

2
2
2
3
3
3
3

2
2
2
3
3
3
3

0
0
0
0
1
1
2
0
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

0
0
0
0
1
1
2
0
0
0
1
2
3
4
0
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

0
0
0
0
1
1
2
0
0
0
1
2
3
4
0
0
1
2
3
4
6
0
1
2
3
5
7
9

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
4
5
6
7
8
9
10

0 2
0 2
0 2
0 3
1 3
1 3
2 3
0 2 0 2
0 2 0 3
0 2 0 3
0 3 1 4
1 3 2 4
1 3 3 5
2 3 4 5
0 2 0 3
0 3 0 3
0 3 1 4
1 4 2 5
2 4 3 6
3 5 4 6
4 5 6 7
0 3 0 4
0 3 1 5
1 4 2 6
2 5 3 7
3 6 5 8
4 6 7 9
6 7 9 10
0 4 0 4
1 5 2 7
2 6 4 9
3 7 6 11
5 8 9 12
7 9 12 14
9 10 14 15
0 4 0 6
2 7 3 9
4 9 7 12
6 11 10 15
9 12 16 17
12 14 18 20
14 15 21 22

0.65

1.0

Ac
Rc

Ac
Rc

0 2
0 2
0 2
0 3
1 3
1 3
2 3
0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33

0 2
0 3
0 3
1 4
2 4
3 5
4 5
0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49

Ac
Rc

1.5

0 3
0 3
1 4
2 5
3 6
4 6
6 7
0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

2.5

0 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

4.0

0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

ty Levers (tightened inspection)


Ac
Rc

6.5

0 6
3 9
7 12
10 15
16 17
18 20
21 22
1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

10

1 8
6 17
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

15

3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

25

6 15
16 25
25 36
37 66
49 55
61 64
72 73

Ac
Rc

40

Ac
Rc

65

100

Ac
Rc

150

Ac
Rc

250

Ac
Rc

400

Ac
Rc

650

Ac
Rc

1000

Ac
Rc

TABELA 16. Multiple Sampling Plans for Reduced Inspection (Master Table)
Sam
Correlat
ple
Sample
ive
Size Sample
Size
Sample 0.010 0.015 0.025 0.040 0.065
Code
Ac
Ac
Ac
Ac
Size Ac
Rc
Rc
Rc
Rc
Rc
Letter
A
B
C

D
E
F

Acceptable Quality Levers (reduced inspectio


0.10
Ac
Rc

0.15
Ac
Rc

0.25
Ac
Rc

0.40
Ac
Rc

0.65
Ac
Rc

1.0
Ac
Rc

1.5
Ac
Rc

2.5
Ac
Rc

4.0
Ac
Rc

.
.
.

First
Secon
Third
Fourth
Fivth
Sixth
Seven
First
Secon
Third
Fourth
Fivth
Sixth
Seven
First
Secon
Third
Fourth
Fivth
Sixth
Seven
First
Secon
Third
Fourth
Fivth
Sixth
Seven
First
Secon
Third
Fourth
Fivth
Sixth
Seven

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
63
78
91

0
0
0
0
0
0
1

2
2
2
3
3
3
3

0
0
0
0
0
0
1
0
0
0
0
1
1
1

2
2
2
3
3
3
3
3
3
4
5
6
6
7

0
0
0
0
0
0
1
0
0
0
0
1
1
1
0
0
0
1
2
3
4

2
2
2
3
3
3
3
3
3
4
5
6
6
7
3
4
5
6
7
7
8

0 2
0 2
0 2
0 3
0 3
0 3
1 3
0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10

*
0 2
0 2
0 2
0 3
0 3
0 3
1 3
0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14

ty Levers (reduced inspection)


6.5
Ac
Rc

10
Ac
Rc

15
Ac
Rc

.
.
*
*
0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17

*
*
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

25
Ac
Rc

.
.
*
*
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

40
Ac
Rc

65
Ac
Rc

.
.
.

.
.
.

*
*
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

*
*
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

100
Ac
Rc

.
.
.
*
*
*
*
0 6
3 9
6 12
8 15
11 17
14 20
18 22

150
Ac
Rc

.
.
.

250
Ac
Rc

.
.
.
*
*

400
Ac
Rc

.
.
.
*
*

.
.
.
*

650
Ac
Rc

1000
Ac
Rc

.
.
.

.
.

TABELA 16. Multiple Sampling Plans for Reduced Inspection (Master Table)
Sampl
Correlat
e Size
Sample
ive
Sample
Code
Size Sample 0.010 0.015 0.025 0.040 0.065
Ac
Ac
Ac
Ac
Ac
Letter
Size Rc
Rc
Rc
Rc
Rc
L

First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh
First
Second
Third
Fourth
Fivth
Sixth
Seventh

32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315

32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2205

Acceptable Quality Levers (tightened inspecti


0.10

Ac
Rc

0.15

0
0
0
0
0
0
1

2
2
2
3
3
3
3

0
0
0
0
0
0
1
0
0
0
0
1
1
1

2
2
2
3
3
3
3
3
3
4
5
6
6
7

0
0
0
0
0
0
1
0
0
0
0
1
1
1
0
0
0
1
2
3
4

2
2
2
3
3
3
3
3
3
4
5
6
6
7
3
4
5
6
7
7
8

0 2
0 2
0 2
0 3
0 3
0 3
1 3
0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10

0.40

0.65

1.0

Ac
Rc

Ac
Rc

Ac
Rc

Ac
Rc

0 2
0 2
0 2
0 3
0 3
0 3
1 3
0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14

0 2
0 2
0 2
0 3
0 3
0 3
1 3
0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17

0 3
0 3
0 4
0 5
1 6
1 6
1 7
0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

0 3
0 4
0 5
1 6
2 7
3 7
4 8
0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

0 4
0 5
1 6
2 7
3 8
4 9
6 10
0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

0.25

Ac
Rc

Ac
Rc

1.5

0 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

Ac
Rc

2.5

0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

Ac
Rc

4.0

0 6
3 9
6 12
8 15
11 17
14 20
18 22

ty Levers (tightened inspection)


Ac
Rc

6.5

Ac
Rc

10

Ac
Rc

15

Ac
Rc

25

Ac
Rc

40

Ac
Rc

65

100

Ac
Rc

150

Ac
Rc

250

Ac
Rc

400

Ac
Rc

650

Ac
Rc

1000

Ac
Rc

Você também pode gostar