Escolar Documentos
Profissional Documentos
Cultura Documentos
60227
9760
0281
6500
CHARACTERISTIC
Mobile
Household
Appliances
Maximum
Operating
Temperature
Maximum
Short circuit
Temperature
Installation
Temperature
Min 5 C
Test Voltage
(AC)
(2kV)
Flexible
Flame
Retardant
Lead Free
APPLICATION
Used for equipments running with low voltage and with medium mechanical stresses with free movement without tensile
stress, like refrigerators, washing machines, etc. and also for household equipments in dry and damp areas. If mechanical
stress exists, it is used in covered and dry places. Usually, it is not suitable for exterior and industrial usage.
-Mobile Household Appliances
TECHNICAL INFORMATION
Nominal Cross-Section
Cu Factor
Overall Diameter of
Cable
(Approx.)
Net Weight
(Approx.)
Conductor DC
Resistance at
20 C (max)
mm2
kg/km
mm
kg/km
/km
Current
Carrying
Capacity
A
2X0.50
9.6
5.2
40
39
2X0.75
14.4
5.4
11
26
13
3X0,50
14.4
5.5
43
39
3X0.75
21.6
5.7
53
26
13
4X0.50
19.2
5.9
53
39
4X0.75
28.8
6.3
63
26
13
H03VV-F
2 CORES
3 CORES
4 CORES
H05VV-F
2 CORES
2X0.75
14.4
6.1
58
26.00
13
2X1.0
19
6.4
64
19.50
15
2X1.5
29
7.3
85
13.30
20
2X2.5
48
8.9
129
7.98
26
2X4
77
10.3
180
4.95
33
2X6
116
11.8
48
3.30
42
2X10
192
15.7
460
1.91
56
2X16
308
18.0
631
1.21
76
3X0.75
21.6
6.5
67
26.00
13
3X1.0
29
6.9
78
19.50
15
3X1.5
43
8.1
109
13.30
20
3X2.5
72
9.7
162
7.98
26
3X4
115
11.1
227
4.95
33
3X6
174
12.8
312
3.30
42
3X10
288
17.3
570
1.91
56
3X16
462
19.5
783
1.21
76
4X0.75
29
7.1
80
26.00
13
4X1.0
38
7.7
98
19.50
15
4X1.5
58
8.9
135
13.30
20
4X2.5
96
10.6
200
7.98
26
4X4
154
12.2
285
4.95
33
4X6
230
14.4
390
3.30
42
4X10
384
18.7
694
1.91
56
4X16
616
21.5
981
1.21
76
5X0.75
36
8.0
99
26.00
13
5X1.00
48
8.3
115
19.50
15
5X1.50
72
10.0
169
13.30
20
5X2.50
120
11.9
245
7.98
26
5X4
192
13.9
352
4.95
33
3 CORES
4 CORES
5 CORES
5X6
290
15.7
467
3.30
42
5X10
480
20.5
821
1.91
56
5X16
770
23.8
1172
1.21
76
Nominal Voltage
Test
Voltage(AC)
Uo/U = 300/300V
(H03VV-F)
Uo/U = 300/500V
(H05VV-F)
2 kV
Maximum
Maximum
Operating
Minimum
Insulation
Operating
Short Circuit Temperature
Installation
Resistance
Temperature Temperature
Range
Temperature
20.0 MOhm x
-70 C
160 C
-20...60 C
5 C
km
Minimum Bending
Radiusm
7,5 x Cable
GENERAL INFORMATION
Outer Sheath Color
No. of cores
2....5
Conductor Type
Insulation
PVC Insulation, complying to, DIN
Class 5 Fine-stranded wire copper conductor VDE 0281 T.3, HD 21.3 S3 ve IEC
60227-3
CABLE CHARACTERISTICS
Flexibility
Flame Retardant
Mechanical Stress
Resistance
Chemical
Resistance
Flame
Retardant
Water
Resistance
Air Resistance
FLEXIBLE
Complying to IEC
60332-1
LOW
GOOD
NO
GOOD
NOT GOOD
MARKING
OZLER KABLO H05VV-F 2x1.5
PACKAGING
Coil
FORWARDING LENGTH
100 m