Você está na página 1de 33

Power Meters Catalog

V4.0

Power metering & energy efficiency management

Zhuhai Pilot Technology Co. Ltd.

Established in 2000, Zhuhai Pilot Technology Co., Ltd. occupies an area of 20,000 square meters plant with nearly 400 staffs. PILOT headquarter in Zhuhai of China, and equipped with a R&D center in Shenzhen Nanshan Technology Park.

Our business is throughout the world with over 20 branch offices in China, and distribution network in Germany, Romania, Iran, Saudi Arabia, UAE, Pakistan, India, Indonesia, Malaysia, New Zealand, Australia, Canada, Mexico, Colombia, Chile, Brazil etc.
Our products and services: --Digital panel meters --Multifunction power meters --Energy meters --Power Quality Analyzer --Branch circuit monitor --LV motor protection and control devices --Leakage current detectors --Energy efficiency solution

Additional, our R&D team design customized products to satisfy your special requirements.

CONTENTS
Page

Certificate Projects References Product Selection Guide Products


PST700Multifunction Power Meter

1 2 4

PMAC615 Single Phase Digital Panel Meter PMAC625 Three Phase Digital Panel Meter

8 9

PMAC720 Multifunction Power Meter PMAC727 Multifunction Power Meter PMAC735 Multifunction Power Meter PMAC760 Multifunction Power Quality Analyzer

11 14 17 20

PMAC901 Single Phase Din-rail Energy Meter PMAC903 Three Phase Din-rail Energy Meter PMAC905 Multifunction Energy Meter PMAC915 Three Phase Multi-tariff kWh Meter PMAC921 Single Phase Multi-tariff kWh Meter

23 23 25 27 29

Certificate

Projects References
Projects Abroad
Hindustan Zinc Limited, the Lead Plant and Silver Plant ( India) IKEA Mega Bangna - IKEA Asias Largest Complex (Thailand) Trekkpje Uranium Plant (South Africa) D.G Khan Cement Plant (Pakistan) Bandung Hydropower Plant (Indonesia) Scotts Feeds Factory Project ( U.K.) Iranian Petrochemical Project ( Iran)

Olympic Venues
Beijing Olympic Hockey Center Beijing Olympic Beach Volleyball Center Beijing Olympic Shooting Range Qingdao International Sailing Center Beijing Olympic Basketball Gymnasium

Municipal Projects
Shanghai F1 International Circuit Shanghai Pudong Government Processing Center Shanghai World Expo - World Expo Axis Shanghai World Expo Village, Block B/ Block D/E plot Shanghai World Expo-China Pavilion Bank of China Shanghai Information Center Chengdu Commodity Inspection Bureau Guangzhou Baiyun International Convention and Exhibition Centre, Phase I, II, III Guangzhou International Financial Center (also known as Guangzhou West Tower) Handan Wastewater Treatment Plant Hangzhou Nanxing Water Plant Industrial and Commercial Bank of China Head Office Building, Xinjiang Nanjing Jiuhuashan Tunnel New Museum of Nanjing Massacre Memorial Hall Sichuan Cangxi Wastewater Treatment Plant Sichuan Wenjiang Water Plant Urumqi Inspection Centre Xingjiang Radio and Television Building Xinjiang Television Station Building

Power Plants / Hydropower Plants


Yunfu Power Plant of Guangdong Electric Xuangxin Power Plant in Inner Mongolia Xinjiang Manasi Power Plant, Phase III Daihai Power Generation Co. Ltd. 4 600MW project, in Inner Mongolia "Shandong Binzhou Weiqiao Thermoelectric Co., Ltd. Zouping 3rd Thermoelectric Plant: 8 135KW Project" Inner Mongolia Yuanbaoshan Power Plant:2 600MW project Inner Mongolia JingLong (Fengzhen) Power Plant: 2 600MW project Xinjiang Hami Power Plant Xinjiang Qiapuqihai Hydropower Station Xinjiang Turk Yamaguchi Hydropower Station Xinjiang Karasuk Hydropower Station Jilintai Hydropower Station II Expansion Project of Qinshan Nuclear Power Station Phase II

Airports / Metro
Guangzhou New Baiyun International Airport Shanghai Pudong International Airport, Phase II Shanghai Hongqiao Airport Reconstruction Project Qingdao Luiting International Airport Wuxi Airport Urumqi Airport Overnight Floor Xinjiang Kanas Airport Terminal Beijing Metro Line 4#, 5# Shanghai Metro Line 6#, 7# Dalian Light Rail Line 3# Shenzhen Metro Line 1# Guangzhou Metro Line 2#/ 3#, 4#

Projects References
Telecommunication Porjects
Shenzhen King Tin Telecommunications Room Shenzhen Fu Yong Telecommunications Room, Phase I,II,& III China Netcom Building in Shanghai China Mobile Building in Henan China Mobile Building in Wangjing China Unicom Building in Zhuhai

Tobacco Industry
Hongyun Group, Kunming Cigarette Factory Moving Project Longyan Cigarette Factory Guiyang Cigarette Factory Hongta Group, Yuxi Cigarette Factory Hongyun Group, Honghe Cigarette Factory Shijiazhuang Cigarette Factory

Hospital / Gym/ School


Tsinhua University Environmental Building Palais Omnisports of Guangzhou Asian Games City Dongguan Changping Chang An Hospital Shanghai Nanhui Central Hospital Shanghai Red House Hospital Shanghai Donghua University, Songjiang Campus Guangzhou University City Complex Building, Phase I, II & III The New Campus of Sichuan Normal University Shanghai Stadium Foshan Century Lotus Stadium Foshan Swimming Pool Foshan Pearl Stadium Beijing Chaoyang Hospital

Commercial/ Complex Buildings


TPL National Support Center / Shanghai Guangzhou Science Meseum Guangdong GSM Building Shenzhen Ho Shing Commercial Centre Shenzhen Hong Long Century Plaza Guangxi TV Station/ Guangxi Science Museum Chongqing Grand Theatre Beijing Yanjing Hotel Beijing Big Bell Temple Commercial Plaza Beijing Chang An Grand Mall Shanghai Gubei Fortune Centre Shanghai Tongji Union Square Shangri-La Hotel, Qingdao Hanzhong IMC Times Square in Shaanxi

Oil/ Chemical/ Light Industry


China Heavy Truck ZF Steering Project Daqing Petrochemical 1.2 million / N delayed coking Daya Bay CNOOC Phase II and petrochemical supporting project Henan Zhongzhou Aluminum Inner Mongolia Yitai Coal Chemical Project New paper mill project in Myanmar Rene Sola project in Sichuan, 3,000 tons of polysilicon Shanghai Chlor-Alkali Chemical PVC project Shanghai Huayi Group, 6500 tons / year synthetic camphor agent project Shanghai No. 5 Iron and Steel Plant Shanxi Coking Group, 1 million tons of coking Shihezi Tianye Chemical, 500,000 tons of calcium carbide project Sinopec (GZ) 1 million t catalytic cracker Sinopec East Gas Transmission - Puguang gas field project Sinopec Fujian Petrochemical integration project Sinopec Refining & Chemical Project in Shijiazhuang Xinjiang Tianshan Cement, 2000 tons / D Xinjiang Yili Steel, 300,000 tons of calcium carbide project in Nilka 3

Product Selection Guide


Model Features PST700 PMAC615 PMAC625 PMAC720 PMAC735 PMAC727 PMAC760 PMAC901 PMAC903 PMAC905 PMAC915 PMAC921

Photo

Display Single or 3 phase Real-time measurement U, I, P, Q, kWh S PF, F kvarh kVAh Demand Max./ min. value Multi-tariff energy Phase angle Temperature Power quality analysis Harmonic Voltage crest factor Current K factor Unbalance rate Load rate U or F deviation DI/ DO Status input Relay output Analog input Analog output Pulse output Communication RS485 / Modbus The 2nd RS485 Profibus Ethernet or USB Infrared COM Memory card Other functions SOE event log Setpoint alarm Data record standard feature

LCD 3

LED single

LED 3

LCD 3

LCD 3

LCD 3

LCD 3

LCD single

LCD 3

LCD 3

LCD 3

LCD single

optional feature

PST700 Multifunction Power Meter


Feature
Suit for LV/ HV voltage system
For low voltage system, PST700 direct connect up to 600VAC For high voltage system, PTS700 need to connect with PTs, PT ratio programmable

New appearance and design


Large LCD display and button, replace AI capacitor by Tam capacitor

Self-testing phase sequence error


In case of error phase sequence input, PST700 will display on LCD

Real-time measurement
True-RMS measuring parameters includes: U, I, P, Q, S, PF, F, kWh, kvarh, kVAh, demand, max./min. value

Demand calculation mode is programmable


2 kinds of demand modes: fixed mode and slip mode Demand cycle programmable: 5/ 10/ 15/ 30/ 60mins Slip window programmable: 1/ 2/ 3/ 5mins


Basic unit Optional module

Multi-tariff billing, historical data of 31 days and 12 months


2 kinds of setting modes: time zone mode and holiday mode Time zone mode: 2 time zones in one year Holiday mode: working days ( Mon.- Fri.) and holidays ( Sat.- Sun.) There are 2 lists of tariff rate, each list can setup 8 periods of time in 24 hours, 4 tariff rates.

Power quality analysis


Harmonic analysis, crest and K factor, unbalance etc.

Optional module and upgradeable


Pluggable in option module, support online upgrade

Setpoint alarm
Under/ over limit alarm, monitoring objects include: U, I, PF, F, THD, unbalance If any parameters is over or under limit and persists over the specified time, PST700 will record the event, and trip relay output signal.

High accuracy
Active energy: according to IEC62053-22, class 0.5s Reactive energy: according to IEC62053-23, class 2

Small size and thin style


Panel: 96x96x13.5mm Cut-out: 90x90mm,

Depth: 45.1mm (basic unit) + 21.5mm (optional module)

Standard

IEC62053-22/ 23, CE. KEMA 5

PST700 Multifunction Power Meter


Basic Function
Voltage Current Power Power factor Real time metering Energy Frequency Demand & Max. demand Max./ min. value Multi-tariff energy Unbalance Harmonic (31st ) Power quality analysis Harmonic RMS (0-31st ) Harmonic energy (1st -31st ) Voltage crest factor, current K factor, Load rate, Voltage deviation, Frequency deviation Setpoint alarm 3DI +2 DO RS485 Record function Voltage/ frequency deviation, Voltage unbalance record Over/ under limit alarm 3 status input + 2 relay output Modbus-RTU protocol SOE (event log), Real-time clock ( yyyy-mm-dd hh:mm:ss) U_unbl, I_unbl THDu, THDi, TOHDu, TOHDi, TEHDu, TEHDi, HRU, RHI Harmonic RMS-U, Harmonic RMS-I Ua, Ub, Uc, Uab, Ubc, Uca, UL-L avg, UL-N avg Ia, Ib, Ic, In, Iavg Pa, Pb, Pc, P, Qa, Qb, Qc, Q, Sa, Sb,Sc, S PFa, PFb, PFc, PF kWh and kvarh (4 quadrant), kVAh F Dmd_I, Dmd_P, Dmd_Q ,Dmd_S Max./ min. (U, I, P, Q)

Optional Module
S R C Ep 2 status input 2 relay output The 2 RS485
nd

P AI AO

Profibus communication 2 analog input (4-20mA) 2 analog output (4-20mA)

2 pulse output

Parameter

Accuracy

Resolution

Measuring Range Direct: 600Vph-ph

Voltage

0.2%

0.01V

PT primary: 0~999.9kV PT secondary: 100Vph-ph or 110V CT primary: 0~49,999A CT secondary: 1 A or 5A each phase: 0~49994MW/ Mvar/ MVA

Current

0.2%

0.001A

Power Power factor Frequency Active energy Reactive energy THD Individual harmonic Un-balance

0.5% 0.5% 0.01 0.5% 2.0% 1.0% 1.0% 1.0%

0.1W/var/ VA Total: 0~149982MW/ Mvar/ MVA 0.001 0.01Hz 0.1kWh 0.1kvarh 0.001 0.001 0.001 -1.000~+1.000 45~ 65 Hz 0~ 99,999,999.9 kWh 0~ 99,999,999.9 kvarh 0~100.0% 0~100.0% 0~100.0%

PST700 Multifunction Power Meter


Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 1A or 5A Rate voltage: direct 120 ~277Vph-N, (optional) PT secondary: 100Vph-ph or 110V, (optional) Frequency: 50/ 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec Wet contact, external power supply Node capacity: 250VAC/5A Pulse output value: 1000~9999imp/ kWh Pulse width: 60~100ms programmable AC 2KV/minute 50M 4kV (peak), 1.2/50uS Standard (EMC) Electrostatic discharge immunity test IEC 61000-4-2,Level 4 Radiated immunity test IEC 61000-4-3,Level 3 Electrical fast transient/burst immunity test IEC 61000-4-4,Level 4 Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-5,Level 3 EN 55022,Class B EN 55022,Class B IP index Weight Environment Power supply Power loss Communication 86 ~265VAC99~374VDC 2VA RS485 serial, support Modbus-RTU Baud rate: 2400, 4800, 9600, 19200, 38400bps Address: 1~247 Panel: 96 x 96 x 13.5 mm Cut-out: 90 x 90 x 45.1 mm (basic) 90 x 90 x 66.6 mm (optional module) IP52 (front panel) and IP30 (case) Basic unit: approx 400gr. Operating temperature: -10~ +55 Storage temperature: -40~ +70 Humidity: 5%~95% non-condensing

Overload

Dimension (L x W x H)

Status input Relay output Pulse output

Power frequency withstand voltage Insulation resistance Impulse withstand voltage

Dimension & Installation


Unit: mm

Order Information
Basic unit: PST700
Note: 1: Current input 5A (optional 1A) 2: Voltage input: 0~600V. 3. Default PT secondary 100Vph-ph. (optional 110V)

Optional module
S R C Ep 2 status input, 2 relay output The 2nd RS485 2 pulse output P AI AO Profibus communication (under development) 2 analog input (under development) 2 analog output (under development)

Note: 1. Max. 3 modules for 1 meter. 2. Module A can be repeatedly chosen for 1 meter, others can not be repeatedly chosen. 7

PMAC615 Single Phase Digital Panel Meter


Feature
Suit for 220V or 240V low voltage system. Simultaneous sampling of Volts and Amps Compact design with all real-time measurement 10 years back-up of integrated energy data LED display, high brightness, auto-scrolling CT ratio programmable Pluggable terminals, easy to install and maintain Panel size: 110 x 65mm Standard: IEC62053-21, CE

Basic Function
Parameter Voltage Current Real time metering Power Power factor Frequency Active energy Accuracy 0.2% 0.2% 0.5% 0.5% 0.01 1.0% Resolution 0.01V 0.001A 0.1 MW/ var 0.001 0.01Hz 0.1kWh Measuring Range 0 ~ 500Vph-ph 0 ~ 50,000A 0 ~30MW/ Var -1.000 ~ +1.000 45 ~ 65Hz 0-99,999,999.9 kWh

Optional Function
DI DO COM Two status input (wet contact) One relay output One RS485

Note: Reactive power and power factor can be read via RS485 COM only

Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 5A (optional 1A) Rate voltage: 220V (optional 240V) Frequency: 50 or 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec 2 channels, external power supply 1 channel, Node capacity: 220VAC/5A, 30VDC/5A 85~265VAC, 80~300VDC 3VA RS485 serial, support Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Power frequency withstand voltage Insulation resistance Impulse withstand voltage AC 2KV/minute 50M 4kV (peak), 1.2/50uS

Overload

Dimension (L x W x H) IP index Weight Environment

Panel: 110 x 65 x 18 mm Cut-out: 90 x 44.5 x 55 mm (+0.5mm) IP54 (front panel) and IP20 (case) Approx 220gr.

Status input Relay output

Power supply Power loss Communication

Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing Standard (EMC)

Electrostatic discharge immunity test IEC 61000-4-2,Level 4 Radiated immunity test IEC 61000-4-3,Level 3 Electrical fast transient/burst immunity test IEC 61000-4-4,Level 4

Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions

IEC 61000-4-5,Level 3 EN 55022,Class B EN 55022,Class B

Order Information
PMAC615----
W Z S RC C Voltage + Current + Active Energy Voltage + Current + Active Power + Reactive Power + Power Factor + Frequency + Active Energy Two External Status Input ( wet contact) One Relay Output + One RS485 COM One RS485 COM

PMAC625 Three-phase Digital Panel Meter


Feature
Suit for 220V, or 240V (ph-N) low voltage system Simultaneous sampling of Volts and Amps Compact design with all real-time measurement 10 years back-up of integrated energy data LED display, high brightness, auto-scrolling CT primary is programmable Pluggable terminals, easy to install Panel size: 96 x 96mm Password protect Standard: IEC62053-21, CE

Basic Function
PMAC625 measures and display one or more parameters listed below: VoltageUa, Ub, Uc, Uab, Ubc, Uca, CurrentIa, Ib, Ic, In Active power Pa, Pb, Pc, P Reactive power Qa, Qb, Qc, Q Power factorPFa, PFb, PFc, PF Frequency--F Active energykWh Reactive energy-- kvarh

Optional Function
Two status input ( wet contact) Two relay alarm output One RS485 communication

Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 5A (optional 1A) Rate voltage: 220Vph-N (optional 240V) Frequency: 50/ 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec 2 channels, external power supply 2 channels, Node capacity: 220VAC/5A, 30VDC/5A 85~265VAC, 80~300VDC 2VA RS485 serial, support Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Standard (EMC) Electrostatic discharge immunity test Radiated immunity test Electrical fast transient/burst immunity test IEC 61000-4-2,Level 4 IEC 61000-4-3,Level 3 IEC 61000-4-4,Level 4 Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-5,Level 3 EN 55022,Class B EN 55022,Class B Power frequency withstand voltage Insulation resistance Impulse withstand voltage AC 2KV/minute 50M 4kV (peak), 1.2/50uS

Overload

Dimension (L x W x H) IP index Weight Environment

Panel: 96 x 96 x 18 mm Cut-out: 89.5 x 89.5 x 65 mm (+0.5mm) IP54 (front panel) and IP20 (case) Approx. 350gr. Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing

Status input Relay output

Power supply Power loss Communication

PMAC625 Three-phase Digital Power Meter


Parameter Voltage Current Power Power factor Frequency Active energy Reactive energy Accuracy 0.2% 0.2% 0.5% 0.5% 0.01 1.0% 2.0% Resolution 0.01V 0.001 0.1W/ var 0.001 0.01Hz 0.1kWh 0.1kvarh Measuring Range 264V(ph-N), 500V (ph-ph) CT primary: 0~9,999A CT secondary: 1 A or 5A 9,999 kW/ kvar -1.000~+1.000 35-65Hz 0-99,999,999.9 kWh 0-99,999,999.9 kvarh

Dimension & Installation


Unit: mm

Order Information
PMAC625---
W Z Voltage + Current + Active Power + Reactive Power + Power Factor + Active Energy Voltage + Current + Active Power + Reactive Power + Power Factor + Frequency + Active Energy + Reactive Energy Two External Status Input ( wet contact) Two Relay Alarm Output One RS485 COM

S R C

Note: PMAC625 default rated voltage/ current is 220V/ 5A. Other customized input such as 240V or 1A is available, please mention the requirement before place order. Example: Model No. PMAC625-W-C, which indicates the device measures voltage, current, active power, reactive power, power factor, active energy, and provide RS485 communication

10

PMAC720 Multifunction Power Meter


Feature
Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High accuracy, V or I is 0.2%, kWh is class 1 CT and PT programmable Panel size: 96 x 96mm Password protect Standard: IEC62053-21/ 23, CE

Basic Function
PMAC720 provides one RS485 communication, measures and display real-time parameters: VoltageUa, Ub, Uc, Uab, Ubc, Uca, CurrentIa, Ib, Ic, In Active power Pa, Pb, Pc, P Reactive power Qa, Qb, Qc, Q Power factorPFa, PFb, PFc, PF Frequency--F Active energykWh Reactive energy kvarh Basic unit Optional module

Optional Module
4 status input (dry contact) + 4 relay output 8 status input (dry contact) + 2 relay output 4 status input (wet contact) + 4 relay output 8 status input (wet contact) + 2 pulse output 2 pulse output + 2 analog output

Optional Function
Up to 31st harmonic analysis Clock and SOE (event log) TOU (multi-tariff) Two RS485 communication port One 4~20mA analog input One 4~20mA analog output

Status input apply to monitoring various kinds of switch status Relay output apply to monitoring over limit alarm with setpoint system Pulse output apply to exporting pulse signal for active/ reactive energy

Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 5A (optional 1A) Rate voltage: direct 120 ~277Vph-N, (optional) PT secondary 57.7V/ 100V Frequency: 50/ 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec 8 channels, provides 30VDC power if it is dry contact 4 channels, Node capacity: 220VAC/5A, 30VDC/5A Power frequency withstand voltage Analog output (optional) Pulse output (optional) 2 channels, 4~20mA, load resistance: 400 2 channels, 48~50VDC for external connection Insulation resistance Impulse withstand voltage AC 2KV/minute 50M 4kV (peak), 1.2/50uS Power supply Power loss Communication 85~265VAC, 80~300VDC 2VA RS485 serial, support Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Panel: 96 x 96 x 16 mm Cut-out: 89.5 x 89.5 x 55 mm (+0.5mm) IP54 (front panel) and IP20 (case) Approx. 500gr.

Overload

Dimension (L x W x H) IP index Weight

Status input (optional) Relay output (optional)

11

PMAC720 Multifunction Power Meter


Standard (EMC) Electrostatic discharge immunity test RF immunity test Electrical fast transient/burst immunity test Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-2 Edition 2.0 (2008) IEC 61000-4-3 Edition 3.0 (2007) IEC 61000-4-4 Edition 2.0 (2004) IEC 61000-4-5 Edition 2.0 (2005) EN 61326-1:2006, CISPR 11:2004 EN 61326-1:2006, CISPR 11:2004 Environment Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing

Parameter

Accuracy

Resolution

Measuring Range Directly: 300Vph-N, 520Vph-ph

Voltage

0.2%

0.01V

PT primary: 0~599,999V PT secondary: 57.7Vph-N, 100Vph-ph CT primary: 0~49,999A CT secondary: 1 A or 5A each phase: 0~100 MW/ Mvar

Current

0.2%

0.001A

Power Power factor Frequency Active energy Reactive energy Individual harmonic Un-balance

0.5% 0.5% 0.01 1.0% 2.0% 1.0% 1.0%

0.1W/ var Total: 0~300 MW/ Mvar 0.001 0.01Hz 0.1kWh 0.1kvarh 0.001 0.001 -1.000~+1.000 45~ 65 Hz 0~ 99,999,999.9 kWh 0~ 99,999,999.9 kVarh 0~100.0% 0~100.0%

PMACFeature U-LL, U-LN, 3I, In, 3P, P, 3Q, Q, F, 3PF, PF, kWh, kvarh, RS485 communication 4 status input (dry contact) + 4 relay output 8 status input (dry contact) + 2 relay output 4 status input (wet contact) + 4 relay output 8 status input (wet contact) + 2 relay output 2 pulse output + 2 analog output (4~20mA) H T F M AI AO Up to 31st harmonic analysis Clock and SOE (event log) function TOU ( time-of-use) Two RS485 communication ports One 4~20mA analog input One 4~20mA analog output

720N

720A

720B

720C

720D

720E

Apparent power Demand function

Remark: = standard feature, =optional function = conditional function 1. If select -F, -T should be selected also. 2. Analog port-AI and AO are incompatible feature, can not be selected together 3. For module PMAC720N-, PMAC720E- , the SOE function is invalid.

12

PMAC720 Multifunction Power Meter


Dimension & Installation
unit: mm

Order Information
PMAC720---- ----
N A B C D E H T F M AI AO V1 V2 V3 V4 V5 V6 V7 Basic Module Basic Module + 4 Status Inputs (Dry Contact) + 4 Relay Outputs Basic Module + 8 Status Inputs (Dry Contact) + 2 Relay Outputs Basic Module + 4 Status Inputs (Wet Contact) + 4 Relay Outputs Basic Module + 8 Status Inputs (Wet Contact) + 2 Relay Outputs Basic Module + 2 Pulse Outputs + 2 Analog Outputs (4-20mA) Up to 31st Harmonic Analysis Clock and SOE (Event Log) Function TOU (Time- of- Use) Two RS485 Communication Ports One 4-20mA Analog Input One 4-20mA Analog Output 57.7/ 100V (via PT), 5A 57.7/ 100V (via PT), 1A 220/ 380V (direct), 5A 220/ 380V (direct), 1A 120/ 208V (direct), 5A 240/ 415V (direct), 5A 277/ 480V (direct), 5A

Example: Model No. PMAC720-A-H-AO-V1, which indicates the device provides basic function + 4 status input + 4 relay output + harmonic analysis + one analog output, rated input 57.7/ 100V, 5A

13

PMAC727 Multifunction Power Meter


Feature
Suit for LV/ HV voltage system Compact design with all real-time measurement Build-in clock and event logging Phase failure alarm 10 years back-up of integrated energy data Large LCD, high brightness High accuracy, V or I is 0.2%, kWh is class 1 CT and PT programmable Pluggable terminals, easy to install Panel size: 96 x 96mm Password protect Standard: IEC62053-21/ 23, CE

Basic Function
PMAC727 provides one RS485 communication, measures and display real-time parameters: VoltageUa, Ub, Uc, Uab, Ubc, Uca, Voltage unbalance rate UL-L unbal, UL-N unbal CurrentIa, Ib, Ic, In Current unbalance rate I unbal Active power Pa, Pb, Pc, P, power load rate Reactive power Qa, Qb, Qc, Q Power factorPFa, PFb, PFc, PF Frequency--F Active energykWh Reactive energy kvarh 31st harmonic & THD Temperature of switch box/ cable

Basic Data Recording Function


Record data once per hour ( last 24 hours) Record the Avg/ Max./ Min. data of every day (last 31 days) Record energy consumption hourly ( last 24 hours), daily (last 31 days), and monthly (last 12 months) Record phase failure event, max. 30 events Record over-limit event, max. 200 events

Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 1A or 5A Rate voltage: direct 120 ~277Vph-N, (optional) PT secondary 57.7V/ 100V Frequency: 50/ 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec AC 2KV/minute 50M 4kV (peak), 1.2/50uS Power supply Power loss Communication 85~265VAC, 80~300VDC 2VA RS485 serial, support Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Panel: 96 x 96 x 18 mm Cut-out: 89.5 x 89.5 x 65 mm (+0.5mm) IP54 (front panel) and IP20 (case) Approx. 500gr. Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing

Overload

Dimension (L x W x H) IP index

Power frequency withstand voltage Insulation resistance Impulse withstand voltage

Weight Environment

Standard (EMC) Electrostatic discharge immunity test IEC 61000-4-2,Level 4 Radiated immunity test IEC 61000-4-3,Level 3 Electrical fast transient/burst immunity test IEC 61000-4-4,Level 4 Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-5,Level 3 EN 55022,Class B EN 55022,Class B 14

PMAC727 Multifunction Power Meter


Parameter Accuracy Resolution Measuring Range Directly: 300Vph-N, 520Vph-ph Voltage 0.2% 0.01V PT primary: 0~499,999V PT secondary: 57.7Vph-N, 100Vph-ph CT primary: 0~49,999A CT secondary: 1 A or 5A each phase: 0~100 MW/ Mvar -1.000~+1.000 35~ 65 Hz 0~ 99,999,999.9 kWh 0~ 99,999,999.9 kVarh 0~100.0% 0~100.0% 0~100.0% 0~150

Current Power Power factor Frequency Active energy Reactive energy THD Individual harmonic Un-balance Temperature

0.2% 0.5% 0.5% 0.01 1.0% 2.0% 1.0% 1.0% 1.0% 1

0.001A 0.1W/ var 0.001 0.01Hz 0.1kWh 0.1kvarh 0.001 0.001 0.001 1

Model PMAC727 Measuring Parameters VoltageUa, Ub, Uc, Uab, Ubc, Uca, UL-L unbal, UL-N unbal CurrentIa, Ib, Ic, In I unbal Active power Pa, Pb, Pc, P Load rate Reactive power Qa, Qb, Qc, Q Power factorPFa, PFb, PFc, PF Frequency Active energy kWh (present & total) Reactive energy kvarh (present & total) Fundamental RMS current Harmonic Ratio for Current (3-31st) Total Harmonic Distortion for Current (THDi) Fundamental RMS voltage Harmonic Ratio for Voltage (3-31st) Total Harmonic Distortion for Voltage (THDu) Record data per hour (last 24 hours) and daily (last 31 days), monthly (last 12 months)

Data Record Function Record Avg./ Max./ Min. data of every day (last 31 days) Over-limit record

15

PMAC727 Multifunction Power Meter

Dimension & Installation


unit: mm

Order Information
PMAC727--
V1 V2 V3 V4 V5 V6 V7 57.7/ 100V (via PT), 5A 57.7/ 100V (via PT), 1A 220/ 380V (direct), 5A 220/ 380V (direct), 1A 120/ 208V (direct), 5A 240/ 415V (direct), 5A 277/ 480V (direct), 5A

Example: Model No. PMAC727-V1, which indicates the device provides all basic function, rated input 57.7/ 100V, 5A

16

PMAC735 Multifunction Power Meter


Feature
Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High accuracy, V or I is 0.2%, kWh is class 1 CT and PT programmable Pluggable terminals, easy to install Panel size: 96 x 96mm Password protect Standard: IEC62053-21/23, CE

Basic Function
PMAC735 provide one RS485 communication, measures and display real-time parameters: VoltageUa, Ub, Uc, Uab, Ubc, Uca, Voltage unbalance rate UL-L unbal, UL-N unbal CurrentIa, Ib, Ic, In Current unbalance rate I unbal Active power Pa, Pb, Pc, P Reactive power Qa, Qb, Qc, Q Apparent powerSa, Sb,Sc, S Power factorPFa, PFb, PFc, PF Frequency--F Active energykWh (4 quadrant) Reactive energy kvarh (4 quadrant) Demand and Max. record for I, P, Q, S Max./ Min. value

Optional Module
4 status input + 4 relay output 8 status input + 2 relay output 8 status input + 2 pulse output Profibus communication module

Status input apply to monitoring various kinds of switch status Relay output apply to monitoring over limit alarm with setpoint system Pulse output apply to exporting pulse signal for active/ reactive energy Profibus supports high speed bus communication up to 1.5M, and Compatible with SIEMENS Profibus communication system.

Optional Function
Up to 31st harmonic analysis, K factor, THD SOE (event log) One 4~20mA analog output

Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 1A or 5A Rate voltage: direct 120 ~277Vph-N, (optional) PT secondary 57.7/ 100V Frequency: 50/ 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec 8 channels, provides 30VDC power if it is dry contact 4 channels, Node capacity: 220VAC/5A, 30VDC/5A 2 channels, 4~20mA, load resistance: 400 2 channels, 48~50VDC for external connection Power frequency withstand voltage Insulation resistance Impulse withstand voltage AC 2KV/minute 50M 4kV (peak), 1.2/50uS

Overload

Power supply Power loss Communication

85~265VAC, 80~300VDC 2VA RS485 serial, support Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Panel: 96 x 96 x 18 mm Cut-out: 89.5 x 89.5 x 65 mm (+0.5mm) IP54 (front panel) and IP20 (case) Approx. 500gr.

Status input (optional) Relay output (optional) Analog output (optional) Pulse output (optional)

Dimension (L x W x H) IP index Weight

17

PMAC735 Multifunction Power Meter

Standard (EMC) Electrostatic discharge immunity test Radiated immunity test Electrical fast transient/burst immunity test Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-2,Level 4 IEC 61000-4-3,Level 3 IEC 61000-4-4,Level 4 IEC 61000-4-5,Level 3 EN 55022,Class B EN 55022,Class B

Environment Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing

Parameter

Accuracy

Resolution

Measuring Range Directly: 300Vph-N, 520Vph-ph

Voltage

0.2%

0.01V

PT primary: 0~499,999V PT secondary: 57.7Vph-N, 100Vph-ph CT primary: 0~49,999A CT secondary: 1 A or 5A each phase: 0~100 MW/ Mvar -1.000~+1.000 35~ 65 Hz 0~ 99,999,999.9 kWh 0~ 99,999,999.9 kVarh 0~100.0% 0~100.0% 0~100.0%

Current Power Power factor Frequency Active energy Reactive energy THD Individual harmonic Un-balance

0.2% 0.5% 0.5% 0.01 1.0% 2.0% 1.0% 1.0% 1.0%

0.001A 0.1W/ var 0.001 0.01Hz 0.1kWh 0.1kvarh 0.001 0.001 0.001

Model PMAC Feature U-LL, U-LN, 3I, In, 3P, P, 3Q, Q, 3S, S, F, 3PF, PF, kWh, kvarh, Demand& maximum recording, Unbalance rate, Build-in clock, Max./min. recording, RS485 communication 4 status input + 4 relay output 8 status input + 2 relay output 8 status input + 2 pulse output Profibus communication Harmonic analysis, K factor SOE One 4-20mA analog output Remark: = standard, =optional

735N

735A

735B

735E

735P

18

PMAC735 Multifunction Power Meter


Dimension & Installation
unit: mm

PMAC735

Auxiliary Module

Order Information
PMAC735---- ------
N A B E P H T AO V1 V2 V3 V4 V5 V6 V7 Basic Module Basic Module + 4 Status Inputs (Dry Contact) + 4 Relay Outputs Basic Module + 8 Status Inputs (Dry Contact) + 2 Relay Outputs Basic Module + 8 Status Inputs (Dry Contact) + 2 Pulse Outputs Basic Module + Profibus Module Up to 31st Harmonic Analysis, THD, K Factor SOE (Event Log) Function One 4-20mA Analog Output 57.7/ 100V (via PT), 5A 57.7/ 100V (via PT), 1A 220/ 380V (direct), 5A 220/ 380V (direct), 1A 120/ 208V (direct), 5A 240/ 415V (direct), 5A 277/ 480V (direct), 5A

Example: Model No. PMAC735-A-H-V1, which indicates the device provides basic function + 4 status input + 4 relay output + harmonic analysis, rated input 57.7/ 100V, 5A

19

PMAC760 Intelligent Power Quality Analyzer


Feature
Suit for LV/ HV voltage system True-RMS measuring parameters Power quality analysis, over limit alarm Integrated measure, analyze, control and protect function Use DSP chip to process voltage and current signal Graphical data, easy and clearly for reading Large and color LCD, high brightness 10 years back-up of integrated energy data High accuracy, V or I is 0.2%, kWh is class 1 Panel size: 126.7 x 126.7mm Password protect Standard: IEC62053-21/ 23, CE

Basic Function
Voltage Current Power Power factor Real time metering Energy Max./ Min. value Demand Phase angle Frequency Voltage fluctuate Voltage deviation Power quality analysis Frequency deviation Unbalance Harmonic Setpoint alarm DI/ DO RS485 SOE and Clock Over/ under limit alarm 4 status input + 4 relay output Modbus-RTU protocol Event log and real time clock U_unbl, I_unbl THDu, THDi, TOHDu, TOHDi, TEHDu, TEHDi 2nd-31st harmonic (display), 32nd -63rd harmonic (COM) F Ua, Ub, Uc, Uab, Ubc, Uca, UL-L avg, UL-N avg Ia, Ib, Ic, In, Iavg Pa, Pb, Pc, P, Qa, Qb, Qc, Q, Sa, Sb,Sc, S PFa, PFb, PFc, PF kWh and kvarh (4 quadrant), kVAh Max._U, Max._I, Max._P, Max._Q Min._U, Min._I, Min._P, Min._Q Dmd_I, Dmd_P, Dmd_Q ,Dmd_S

Optional Function
Ethernet USB Ethernet communication port, 10M, UDP/ TCP Server/ TCP Client USB 2.0 communication port

20

PMAC760 Intelligent Power Quality Analyzer


LCD display graphical data
Voltage wave SOE event log Harmonic Phase vector

Multi-communication

Technical Specification
Metering Input True RMS, 1 sec refresh time Rate current: 1A or 5A Rate voltage: direct 120 ~277Vph-N, (optional) PT secondary 57.7/ 100V Frequency: 50/ 60Hz 120% of rated, continuously Instantaneous current: 10 times/ sec Instantaneous voltage: 2 times/ sec 4 channels Dry contact (internal 30VDC power supply) 4 channels, Node capacity: 250VAC/5A, 30VDC/5A Power frequency withstand voltage Insulation resistance Impulse withstand voltage AC 2KV/minute 50M 4kV (peak), 1.2/50uS

Overload

Power supply Power loss Dimension (L x W x H) IP index Weight Environment

85~265VAC, 80~300VDC 10VA Panel: 126.7 x 112.7 x 13 mm Cut-out: 119 x 105 x 91 mm (+0.5mm) IP54 (front panel) and IP20 (case) Approx. 760gr.

Status input

Relay output

Standard (EMC) Electrostatic discharge immunity test Radiated immunity test Electrical fast transient/burst immunity test Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-2,Level 4 IEC 61000-4-3,Level 3 IEC 61000-4-4,Level 4 IEC 61000-4-5,Level 3 EN 55022,Class B EN 55022,Class B

Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing

21

PMAC760 Intelligent Power Quality Analyzer


Parameter Accuracy Resolution Measuring Range Directly: 300Vph-N, 520Vph-ph Voltage 0.2% 0.01V PT primary: 0~999,999V PT secondary: 57.7Vph-N, 100Vph-ph CT primary: 0~49,999A CT secondary: 1 A or 5A each phase: 0~100 MW/ Mvar -1.000~+1.000 45~ 65 Hz 0~ 99,999,999.9 kWh 0~ 99,999,999.9 kVarh 0~100.0% 0~100.0% 0~100.0%

Current Power Power factor Frequency Active energy Reactive energy THD Individual harmonic Un-balance

0.2% 0.5% 0.5% 0.01 1.0% 2.0% 1.0% 1.0% 1.0%

0.001A 0.1W/ var 0.001 0.01Hz 0.1kWh 0.1kvarh 0.001 0.001 0.001

Dimension & Installation


Unit: mm

COM
SHLD

SHLD

Order Information
PMAC760----

N U V1 V2 V3 V4 V5 V6 V7

Ethernet port USB port 57.7/ 100V (via PT), 5A 57.7/ 100V (via PT), 1A 220/ 380V (direct), 5A 220/ 380V (direct), 1A 120/ 208V (direct), 5A 240/ 415V (direct), 5A 277/ 480V (direct), 5A

Example: Model No. PMAC760-N-V3, which indicates the device provides basic function + Ethernet communication port, rated input 220/ 380V, 5A

22

PMAC901 Single Phase Din-rail Energy Meter PMAC903 Three Phase Din-rail Energy Meter

Feature
Suit for 220V AC low voltage system 6 +1 digits LCD display (999999.9 kWh) kWh accuracy class 0.5S LED indicates pulse, reverse energy 3 keys for programming CT programmable, pulse output 35mm DIN rail installing, standard DIN ED5002 High temperature resistant materials Spring type buckle, easy to install Standard: IEC62053-21/ 22/23, CE, KEMA

Basic Function
Measure and display kWh value One RS485 communication Support Modbus-RTU Other real time data via RS485: V, I, P, Q, S, PF, F

Optional Function
Multi-tariff Reactive energy measuring Demand analysis

Technical Specification
Rated current Rated voltage Input consumption Overload Pulse output Pulse output value 10(40)A, 10(60)A, 20(100)A or 5A/ CT AC 220Vph-N, 50Hz (optional 120V, 60Hz) 2VA 115% of rated 1 or 2 channels PMAC901:1000imp/kWh PMAC903: 400imp/ kWh (40A or 60A) 200imp/ kWh (100A) 3600imp/ kWh (5A/ CT) Environment Impulse duration Power supply Communication 80 ms Self supply, 220VAC, 50-60Hz RS485 serial, Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Operating temperature: -20~ +55 Storage temperature: -20~ +55 Humidity: 5%~95% non-condensing Connection mode PMAC901: 1-phase 2-wire PMAC903: 3-phase 4-wire

Standard (EMC) Electrostatic discharge immunity test Radiated immunity test Electrical fast transient/burst immunity test IEC 61000-4-2,Level 4 IEC 61000-4-3,Level 3 IEC 61000-4-4,Level 4 Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions IEC 61000-4-5,Level 4 EN 55022,Class B EN 55022,Class B

Accuracy Parameter PMAC901 Voltage Communication data Current Active power Reactive power Apparent power Power factor Frequency Display data Active energy Reactive energy 0.2% 0.2% 0.5% No 0.5% No No Class 0.5S No PMAC903 0.2% 0.2% 0.5% 1.0% 0.5% 0.5% 0.01 Class 0.5S Class 2 0.01V 0.001A 0.1W 0.1Var 0.1VA 0.001 0.01Hz 0.1kWh 0.1kVarh 198V~242V (L-N) 0.5~4995A 0~1MW 0~1Mvar 0~1MvA -1.000~+1.000 45Hz~65Hz 0~999999.9 kWh 0~999999.9 kvarh 23 Resolution Measuring Range

PMAC901 Single Phase Din-rail Energy Meter PMAC903 Three Phase Din-rail Energy Meter

Dimension
PMAC901
75.0mm 65.0mm 50.0mm

PMAC903
125.5mm 65.0mm 50.0mm

35.7mm

45.0mm

94.0mm

35.7mm

Order Information
PMAC901---- ---- PMAC903---- ----
C 1 0.5S 40 60 100 5 F Q D One RS485 communication Active energy accuracy: Class 1 Active energy accuracy: Class 0.5S Rated current: 10 (40)A Rated current: 10 (60)A Rated current: 20 (100)A Rated current: 5A / CT (when In>100A, connect via CT) TOU (Multi-tariff) Reactive energy measuring (only available for PMAC903) Demand analysis (only available for PMAC903)

Note: PMAC901, 903 default rated voltage 220V, frequency 50Hz. Other customized input such as120V or 60Hz is available, please mention the requirement before place order. Example 1: Model No. PMAC901-C-1-40-F, which indicates the device provides basic function, rated current is 40A (direct), accuracy class 1, and measure multi-tariff Example 2: Model No. PMAC903-C-1-5-Q, which indicates the device provides basic function, rated current is 5A/ CT, accuracy class 1, and measure reactive energy

94.0mm

45.0mm

PMAC903

24

PMAC905 Multifunction Energy Meter


Feature
Suit for LV/ HV voltage system CT and PT programmable kWh accuracy class 0.5S Password protect Panel size: 96 x 96mm Pluggable terminals, easy to install Large high-contrast LCD Two pulse output Standard: IEC62053-22/ 23, CE, KEMA

Basic Function
PMAC905 measure and display real-time parameters: VoltageUa, Ub, Uc, Uab, Ubc, Uca, CurrentIa, Ib, Ic, In Active power Pa, Pb, Pc, P Reactive power Qa, Qb, Qc, Q Apparent powerSa, Sb,Sc, S Power factorPFa, PFb, PFc, PF Frequency--F EnergykWh, kvarh (4 quadrant)

Optional Function
Statistics of multi-tariff energy: 8 periods of time, 4 different tariff Record historical energy value: (kWh & kvarh) data of last 31 days/ 12 months One RS485 communication (Modbus)

Technical Specification
Connection mode Rated current Rated voltage Frequency CT earth connection (secondary) Power consumption Overload 3-phase 3-wire, 3-phase 4-wire 1A or 5A direct 120 ~277Vph-N, (optional) PT secondary 57.7/ 100V 50/ 60Hz yes 3VA 120% of rated Pulse output Pulse output value Impulse duration (width) Power supply Communication 2 channels 1000~9900 imp/kWh programmable 50ms 85 to 265VAC or 100 to 300VDC RS485 serial, Modbus-RTU Baud rate: 4800 or 9600bps Address: 1~247 Operating temperature: -20~ +60 Storage temperature: -30~ +70 Humidity: 5%~95% non-condensing

Environment

Standard (EMC) Electrostatic discharge immunity test Radiated immunity test Electrical fast transient/burst immunity test Parameter Accuracy IEC 61000-4-2,Level 4 IEC 61000-4-3,Level 3 IEC 61000-4-4,Level 4 Resolution Surge immunity test (1, 2/50s8/20s) Conducted emissions Radiated emissions Measuring Range Directly: 300Vph-N, 520Vph-ph Voltage 0.2% 0.01V PT primary: 0~499,999V PT secondary: 57.7Vph-N, 100Vph-ph CT primary: 0~49,999A CT secondary: 1 A or 5A 0~100 MW/ MVar/ MVA -1.000~+1.000 35Hz~65Hz 0~999999.9 kWh 0~999999.9 kvarh 25 IEC 61000-4-5,Level 4 EN 55022,Class B EN 55022,Class B

Current Power Power factor Frequency Active energy Reactive energy

0.2% 0.5% 0.5% 0.01 Class 0.5S Class 2

0.001A 0.1W/ Var/ VA 0.001 0.01Hz 0.1kWh 0.1kVarh

PMAC905 Multifunction Energy Meter


Dimension & Installation
Unit: mm

96mm

9.0

46.7

18.3
90mm

90mm

96mm

Order Information
PMAC905---- ----
F D C V1 V2 V3 V4 V5 V6 V7 Statistics of multi-tariff energy Record historical energy value One RS485 communication 57.7/ 100V (via PT), 5A 57.7/ 100V (via PT), 1A 220/ 380V (direct), 5A 220/ 380V (direct), 1A 120/ 208V (direct), 5A 240/ 415V (direct), 5A 277/ 480V (direct), 5A

Note: Other customized input such as 110V or 1A is available, please mention the requirement before place order. Example: Model No. PMAC905-F-D-V3 , which indicates the device provides basic function, auxiliary statistics and record function. Rated input is 220V/380V, 5A.

56.5 89.5

26

PMAC915 Three Phase Multi-tariff kWh Meter


Feature
LCD display With the DSP technology and the real-time high speed calculation, it guarantees the measuring accuracy in the case of big load wave and harmonic waves. 2MB large data storage, can be extended to 4MB Keep high accuracy from 1% In to 600% In Three phase power source supply, but even there is only one phase work, the meter will keep running. Read the meter at power failure, can still read the meter by the button or with infrared function

Function
Energy measurement: measure kWh or kvarh (reverse/ forward) of 4 quadrants in different tariffs Max. demand measurement: measure Max. demand kWh or kvarh (reverse/ forward) of 4 quadrants in different tariffs Real-time measurement: measure voltage, current, active power, reactive power, power factor, frequency, 2nd -31st harmonic (U and I) Multi-tariff: settable 10 tariffs, 14 time zones, 12 sets of time period list, 14 time periods, 13 holidays, holiday and weekend can be preset in different time periods. No-voltage record: record no-voltage of each phase and total no-voltage time of four months, record no-voltage occurs time, end time and the energy in the time of no-voltage of the last 10 times. Event log: record last 10 demand resetting, program, no phase, over-voltage, no voltage, unti-phase, overload, current unbalance, calibrate time, power off and power on. Load monitor: set voice-optical alarm or relay output when load is beyond a certain value Harmonic monitor: monitor the 2nd 16th harmonic (U and I), when the value is beyond the setting point, the meter alarm and record the event. Energy freeze: freeze the energy by broadcast, also can freeze the energy at hour Load curve: select different data groups with different or same time terminal (1 to 1440 mins optional) to record the data scrolling with time remark. Storage space is not less than 2MKb. Communication port: RS485 and infrared Relay output: two routes programmable relay output Pulse output and LED indicator: two pulse output for active and reactive energy.

Technical Specification
Model Accuracy PMAC915 Active energy Reactive energy Display Rated voltage LCD PT connect: Direct connect Rated (Max.) current CT connect Direct connect Power loss Voltage circuit Current circuit Operating temperature Storage -20C to +60C -40C to +70C 357.7/100V 3220/380V 31(2)A, 35(6)A 310(40)A, 320(80)A, 330(100)A <2W/ 10VA (external power 0.5VA) <1VA Class 0.5s Class 2

27

PMAC915 Three Phase Multi-tariff kWh Meter


Relative humidity Voltage range Reference frequency Start current MTBF Service life Clock error Dimension Net weight Standard 85% 0.7Un ~1.3Un 50Hz 5% 0.001 In 5104 h 15 Years 0.5s /d (23C) 290mm x 170mm x85mm Approx. 1.8 kg IEC62052-11/21 IEC62053-21/22/23 IEC62056-21/ 42/ 53/ 61/ 62

Dimension & Installation


Unit: mm

28

PMAC921 Single Phase Multi-tariff kWh Meter


Feature
LCD display Measure active energy, no need to calibrate for a long working time LSI design, less spare part, low power consumption, simple structure. Keep a good linear error within the range 1%Ib~Imax. Use quality component with long service life, reliable accuracy, cannot be affected by the frequency, temperature, voltage, harmonic.

Function
Measure reverse and forward energy, and reverse energy is measured as forward energy Timely single phase power consumption measurement with 3 tariffs and 12 time periods Automatically read and store the energy, it can store 12 months data Real time Clock RS485 communication port realize remote meter concentrative reading. Infrared communication port to realize point to point communication. Waking up the meter by pressing the key and meter reading function during power off.

Technical Specification
Model Accuracy Display Rated voltage Rated (Max.) current Power loss Voltage circuit Current circuit Operating temperature Storage PMAC921 Active energy: Class 1.0 LCD 220~240V 2.5(10)A, 5(20)A, 5(30)A, 10(40)A, 20(80)A <1W/ 6VA Net weight <1VA Standard -25C to +55C -40C to +70C IEC62052-11/21 IEC62053-21/22/23 IEC62056-21 Approx. 700g Relative humidity Voltage range Reference frequency Start current Clock error Dimension 85% 0.7Un ~1.3Un 50Hz/ 60Hz 0.004Ib 0.5s /d (23C) 182mm x 129mm x 49mm

Dimension & Installation


Unit: mm

29

Zhuhai Pilot Technology Co., Ltd.


Add: No. 15, Keji 6 Road, Chuangxin Haian, Tangjia Hi-tech Zone, Zhuhai, Guangdong, China Post Code: 519085 Tel: +86 756 3629687/ 3629673 Fax: +86 756 3629600/ 3629700 Email: overseamarket@pmac.com.cn http://www.pmac.com.cn

Your representative

PILOT reserves the right to modify features without prior notice in view of continued improvement

Você também pode gostar