Make sure that the dimmer is disconnected from the mains supply, and is not connected to any other equipment Only PAT test if qualified to do so, PAT testing can be hazardous if performed without due care. Read the PAT tester instruction manual for further information on PAT testing. FD dimmers and FD dimmer systems are CLASS I appliances.
FD rack decoders No special instructions apply Insulation should be greater than 19 M Ohm testing at 20 degrees Celsius and 30% relative humidity.
Flash Test
Flash Testing can result in permanent damage to the dimmer. Generally flash testing is not needed for this type of equipment. If however a flash test is needed please contact Avolites for further instructions.
Test Data
Tests performed at Avolites with INSTROTECH PAT 1900xi Test Voltage Current Accuracy of reading
100 mA
10%
Insulation test
1 mA
5%
0-19,9A
10%
3mA a.c
5%