Você está na página 1de 13

Creation of Pipe support MTO from PDMS by using SupportMTO program.

1.0

PURPOSE The intent of this document is to guide new user to be familiar with the SUPPORT MTO PROGRAM.

2.0

INTRODUCTION TO SUPPORT MTO PROGRAM Support MTO Program is a set of Visual Basic Application code, which is compiled in MS-Excel application. The code is self-executable and does not require any special application other than MS-Excel. The MTO File generated is independent of this program and can be opened in Excel without installing this program.

3.0 3.1 3.2 3.3

INSTALLATION To install this program you need MS-Excel (2000) or higher version. If you have any old version of Support MTO Program then you need to delete the old folder before upgrading to Version-1.1. To install the program on your machine follow these steps: a) b) c) d) e) f) Create folder SupportMTO in D:\ Drive. Copy all program files into D:\SupportMTO. Launch MS-Excel. Set Excel Security Level (Tools->Macro->Security) to Medium or Low. Open File InstallationSupportMTO.xls. Click on Button Install Support MTO.

ALSTOM Power TurboSystems

USER MANUAL FOR SUPPORT MTO PROGRAM

Release

Date

Lang.

Sheet

Ver-1.1

08.05.2008

EN

3/ 31

3.4

After successful installation, you get a new menu added to your MS-Excel as below: -

3.5

This menu will remain in Excel till you uninstall Support MTO Program.

4.0 4.1. 4.2.

PROJECT SET-UP Do Project Set-Up at the start of each new project. This activity is required to be done for each project as the Technocode file changes from project to project. Before doing Project-Set-Up, you need technocode dictionary file. Split technocode dictionary file into two different worksheets of one excel file. The first worksheet is named as TechnoCode and second worksheet name as SecondarySteel. You have the flexibility to give some other names also but it is recommended to give this name only for ease in remembering. Keep technocodes of Lisega component in worksheet TechnoCode and technocodes of secondary steels in worksheet SecondarySteel. In case you do not want to use any technocode then delete the relevant rows from this technocode file. The strike-through format in technocode dictionary is not sufficient and ignored by Support MTO Program. Activating following sub menu does project Set-Up.

4.3.

ALSTOM Power TurboSystems

USER MANUAL FOR SUPPORT MTO PROGRAM

Release

Date

Lang.

Sheet

Ver-1.1

08.05.2008

EN

4/ 31

specification of the structural component should be as per techno code dictionary. If the PDMS model contains any structure whose specification & size is not availabe in technocode dictionary, then Support MTO Program can not convert these components into a meaningful techno code. Note that units of quantity in MTO file are dependend on technocode. If technocodes are not correct in MTO file, then qty calculation may be in-correct.

9.5

Normally the following units are used in MTO file as per work procedure WP010 A. Refer the work procedure for more details. A. B. C. D. E. F. G. H. Structural component , metre (m). Plates metre (m). Sheet sq. metre (m2). Lisega Components, Nos. Displacements, mm. Operating Load, kN. Preset Load, kN. Length, m.

9.6

Note that BOX are converted to technocode of plate or sheet based on xlength, ylength and zlength attribute of PDMS. Initially Support MTO Program searches for plate technocode from the tecnocode dictionary for each BOX item. But if the program can not find the plate technocode then it converts item into technocode of sheet. This is done as plates are preferred over sheets.

10.0

MAKING PDMS REPORT FOR SUPPORT MTO

10.1 A PDMS Report template (File name: SUPPORT_MTO_ALL) is supplied along with Support MTO Program as a part of the program. This template may optionally be copied to the PDMS report template folder. Alternatively, it can be run directly from installation directory (D:\SupportMTO) of Support MTO Program. 10.2 To make PDMS support MTO report the following steps are necessary. 10.3 Modify report template as below through Utility menu of PDMS.

ALSTOM Power TurboSystems

USER MANUAL FOR SUPPORT MTO PROGRAM

Release

Date

Lang.

Sheet

Ver-1.1

08.05.2008

EN

14/ 31

10.4 Select PDMS ATTA Report template file SUPPORT_MTO_ALL as shown below. Click OK to proceed.

ALSTOM Power TurboSystems

USER MANUAL FOR SUPPORT MTO PROGRAM

Release

Date

Lang.

Sheet

Ver-1.1

08.05.2008

EN

15/ 31

10.5 Provide inputs as indicated below: -

A. B.

Enter output filename. Default file name is D:\SUPPORTMTOALL.TXT. Enter Site Name(s) and/or Zone(s) etc as required.

10.6 Click Apply to create support MTO file (A). Support MTO Program uses this file.

ALSTOM Power TurboSystems

USER MANUAL FOR SUPPORT MTO PROGRAM

Release

Date

Lang.

Sheet

Ver-1.1

08.05.2008

EN

16/ 31

Creation of KKS line list from PDMS by using LHinterface program.

1.0A

PURPOSE The intent of this document is to guide new user to be familiar with the LH INTERFACE PROGRAM.

2.0A

INTRODUCTION TO LH INTERFACE LH Interface Program is a set of Visual Basic Application code that is compiled in MS-Excel application. The code is self-executable and does not require any special application other than MS-Excel. The LH or PSL generated is independent of this program and can be opened in Excel without installing this program.

3.0A 3.1A 3.2A 3.3A

INSTALLATION To install this program you need MS-Excel (2000) or higher version. If you have any old version of LH Interface Program then you need to delete the old folder before upgrading to Version-2.4. To install the program on your machine follow these steps: a) b) c) d) e) f) Create folder LHINTERFACE in D:\ Drive. Copy all program files into D:\LHINTERFACE. Launch MS-Excel. Set Excel Security Level (Tools->Macro->Security) to Medium or Low. Open File InstallLHInterface.xls. Click on Button Install LH Interface Program.

3.4A

After successful installation, you get a new menu added to your MS-Excel as below:-

ALSTOM Power TurboSystems

USER MANUAL FOR LH INTERFACE PROGRAM

Release

Date

Lang.

Sheet

Ver-2.4

03.05.2008

EN

3/ 43

3.5A

This menu will remain in Excel till you uninstall LH INTERFACE PROGRAM.

4.0 4.1.

LH FROM ROHR2 Support list in AP-Belfort format is named as LH. A new LH can be made from submenu LH from Rohr-2.

ALSTOM Power TurboSystems

USER MANUAL FOR LH INTERFACE PROGRAM

Release

Date

Lang.

Sheet

Ver-2.4

03.05.2008

EN

4/ 43

9.0A 9.1A.

LH/PSL FROM PDMS REPORT A new LH or PSL can be made from sub-menu LH/PSL FROM PDMS REPORT

Select PSL (AP-Baden)

9.2A.

Provide the following information to go-ahead. A. Enter PDMS report file name with the help of Browse.. command button. PDMS report generator generates this file. Refer Clause no. 10.0A PDMS ATTALIST REPORT for more detail.

A B D F G E H C

B.

Select Design Batch. Default is ALL .

ALSTOM Power TurboSystems

USER MANUAL FOR LH INTERFACE PROGRAM

Release

Date

Lang.

Sheet

Ver-2.4

03.05.2008

EN

13/ 43

C.

This check box is optional and is made for updating piping batch information as per line list. On clicking this check box LH Interface will present a dialog box called Read Line List. Refer Clause no. 6.0 READING LINE LIST BY LH INTERFACE to provide input to this dialog box. This information is filled in automatically as per selected file ( A ). Enter LH Document no. Enter Project Name. Enter Support Rev No.. Select Format either LH or PSL.

D. E. F. G. H. 9.3A. 10.0A 10.1A

Click on Create. PDMS ATTA LIST REPORT A PDMS Report template (File name : ATTALIST24) is supplied along with LH INTERFACE as a part of the program. This template may optionally be copied to the PDMS report template folder. Alternatively, it can be run directly from installation directory (D:\LHInterface) of LH INTERFACE. Note that Attribute Attype should be HANG in PDMS. Note that Attribute :POWBATCH should be entered properly in PDMS. To make PDMS ATTA LIST Report the following steps are necessary. Modify Report template as below through Utility menu of PDMS.

10.2A 10.3A 10.4A 10.5A

ALSTOM Power TurboSystems

USER MANUAL FOR LH INTERFACE PROGRAM

Release

Date

Lang.

Sheet

Ver-2.4

03.05.2008

EN

14/ 43

10.6A

Select PDMS ATTA Report template file ATTALIST24 as follow. Click OK to proceed.

ALSTOM Power TurboSystems

USER MANUAL FOR LH INTERFACE PROGRAM

Release

Date

Lang.

Sheet

Ver-2.4

03.05.2008

EN

15/ 43

10.7A

Provide inputs as indicated below:-

A. B. 10.8A

Enter output filename. Default file name is D:\ATTALIST24.TXT. Enter Site Name(s) and/or Pipe(s) etc as required.

Click Apply to create support list file (A).

ALSTOM Power TurboSystems

USER MANUAL FOR LH INTERFACE PROGRAM

Release

Date

Lang.

Sheet

Ver-2.4

03.05.2008

EN

16/ 43

Você também pode gostar