Main features
l Measuring ranges 01 bar to 02000 bar l All standard signals for industry, hydraulics and pneumatics l Media temperature range -40C to 180C l Ambient temperature range -40C to 105C l Shock and vibration-resistant > 1000 g shock, > 20 g vibration l No internal transmitting media (fully welded, dry measuring cell) l Degree of protection from IP65 (special version up to IP69K) l Compact and robust stainless steel design l Precision class 0.5 %

S K L

Applications
l General industrial applications l Automotive engineering l Hydraulics l Pneumatics l Plant engineering and automation

Description
The SKL with cooling fins has been designed for applications with higher temperature requirements. Thanks to its stainless steel diaphragm and semiconductor thin-film technology, this pressure transmitter has excellent properties. The stainless steel diaphragm is fully vacuum-tight, extremely burst-resistant and applicable with all standard media in automotive engineering, hydraulics, pneumatics, etc., as long as they are compatible with stainless steel. Its robust design guarantees high reliability also in rugged conditions. Its modular design offers a variety of signal, thread and connecting options. The SKL series is suited for application in environments exposed to high thermal load.

DPF sensors

www.dpfsensors.com

S K L
Specification
PRESSURE RANGE Measuring range* Overload pressure Burst pressure Measuring range* Overload pressure Burst pressure Measuring range* Overload pressure Burst pressure ELECTRICAL PARAMETER Output signal * and

High Temperature Pressure Transmitter with Cooling Fins

p [bar] p [bar] p [bar] p [bar] p [bar] p [bar] p [bar] p [bar] p [bar]

1,0 6 9 16 40 60 200 400 600 signal

1,6 6 9 20 40 60 250 750 1000

2,0 6 9 25 100 150 400 750 1000

2,5 6 9 40 100 150 600 840 1050 US [VDC]

4,0 10 15 60 200 300 1000 1200 1500

6,0 20 30 100 200 300 1600 2400 3000

10,0 20 30 160 400 600 2000 2400 3000

RL [kWW ] RA [ ] acc. to RA = < (US - 10V) / 0,02 A > 5,0 > 1,0 > 4,7

RA in Ohm

4...20 mA 1...5 VDC

(2-wire, 3-wire)

9...32 12...32 8...32 5 10%

maximum acceptable burden RA

0...10 VDC (3-wire) 0,54,5 VDC ratiometric

Response time * (10-90%) Withstand voltage ACCURACY Accuracy @RT Non-linearity Repeatability Stability/year

t [ms] U [VDC]

<1 350

option 710

% of the range 0,50** BFSL


0,125

% of the range 0,15 % of the range 0,10 % of the range 0,10 ** incl. nonlinearity, hysteresis, repeatability, zero-offset- and final-offset (acc. to IEC 61298-2)

ACCEPTABLE TEMPERATURE RANGES Measuring medium, always Ambience Storage Compensated range* Mean TC offset Mean TC range Total error T [C] T [C] T [C] T [C] -40...160 -40...180 -40...105 -40...105 -20...85 Measuring medium, up to 15 min

Temperature coefficient within the compensated range % of the range 0,15 / 10K % of the range 0,15 / 10K % of the range -40C 2,00% % of the range 105C 2,00% MECHANICAL PARAMETER Parts in contact with the measuring medium* Housing* Shock resistance Vibration resistance Mass CE - conformity IP system of protection * others upon request g g m [g] stainless steel stainless steel 1000 20 ~ 250 acc. to IEC 68-2-32 acc. to IEC 68-2-6 and IEC 68-2-36 (depending on design)

EC Directive 89/336/EWG The IP system of protection as specified in the data sheets generally applies, with their mating plug connected. Relative pressure transmitters usually require a ventilated mating plug and/or cable to aloow for pressure compensation. From a pressure range of 60bar, a ventilated mating plug and/or cable is not necessarily required.

High Temperature Pressure Transmitter with Cooling Fins

S K L

Configuration

-example-

Connectors*
MVS/A DIN EN 175301-803 MVS/C DIN EN 175301-803 male socket M12x1 (S 763) Cable output steel

Pressure Connections*
G A; DIN 3852; Form E GB GB NPT M18x1,5

* Custom-made adjustments acc. to pressure connections and connecting options are possible.

S K L

High Temperature Pressure Transmitter with Cooling Fins

Electrical Connections* (left: 2-wire, right: 3-wire)

MVS/A DIN EN 175301-803

male socket M12x1 (S 763)

MVS/C DIN EN 175301-803

cable output

Legend
power supply consumer

red black white

* Custom-made adjustments acc. to pressure connections and connecting options are possible. Product line
DS4 Electronic Pressure Switch SMC SME SMF SMH SML SMO SMS SMX TPS Pressure Transmitter with CANopen Interface Pressure Transmitter in Miniature Design Pressure Transmitter with Flush Diaphragm High Pressure Transmitter Pressure Transmitter for Industrial Application Pressure Transmitter in Mobile Hydraulics OEM Pressure Transmitter for Hydraulics and Pneumatics Intrinsically Safe Pressure Transmitter for Industrial Application Multi-Function Transmitter for Pressure and Temperature DPSX9I Intrinsically Safe Electronic Pressure Switch for Current DPSX9U Intrinsically Safe Electronic Pressure Switch for Voltage PS1 PSX2 SHP SIS SIL SKE SKL Level Sensor Intrinsically Safe Level Sensor High Precision Pressure Transmitter Low Pressure Transmitter in Short and Compact Design Low Pressure Transmitter for Industrial Application High Temperature Pressure Transmitter with Detached Electronics High Temperature Pressure Transmitter with Cooling Fins

Your contacts sales department: ADZ NAGANO GmbH Lutz Reinhardt Gesellschaft fr Sensortechnik GUEMISA (Electrnica Guerra y Mir Guemisa S.L.) Marion Hotz Bergener Ring 43 D-01458 Ottendorf-Okrilla Sta. Virgilia, 29 - local - 28033 Madrid (Spain) Germany Tlfno.: (034) 91 764 21 00 Fax.: (034) 91 764 21 32 Phone: +49 (0) 35 205 / 59 69-30Email.: Fax:ventas@guemisa.com -59 Web.: www.guemisa.com Email: info@adz.de www.adz.de

Você também pode gostar