TMG PC Strands, Wire & Bar

TMG PC Strands
Low Relaxation Strands
TMG 7-wire Low Relaxation Strands is renowned for its high quality and reliability. Our ability to meet numerous international standards like ASTM A416, BS 5896, JIS G3536, AS/NZS 4672.1, EN 10138 etc. has made us the preferred supplier among our competitors. Being an end user ourselves in posttensioning work or stayed-cable projects, we definitely know what it takes to produce good quality strand to meet tomorrows engineering challenges. TMG is also capable of producing galvanized strands, PE coated strands & epoxy-coated strands for various applications.

Technical data for TMG Low Relaxation PC Strands


Technical data of ASTM A 416-2012
Diameter Diameter Tolerance mm +/- 0.40 Cross Section Area mm2 52.00 69.70 92.90 139.00 55.00 74.20 98.70 140.00 150.00 190.00 Weight Minimum Breaking Strength kN 89 120 160 240 102 138 184 261 279 353 Minimum Yield Strength at 1% Extension kN 80.1 108.1 144.1 216.2 92.1 124.1 165.3 234.6 251.4 318.0 Minimum Elongation to Fracture on 600mm Gauge % 3.5 Relaxation after 1000hrs 70% Breaking 80% Breaking Load Load % < 2.5 % < 3.5

Grade

mm 250 9.50 11.10 12.70 15.20 9.53 11.10 12.70 15.20 15.70 17.80

kg/1000m 405 548 730 1090 430 580 780 1100 1200 1500

+0.65

270

3.5

< 2.5

< 3.5

-0.15

Technical data for TMG Low Relaxation PC Strands


Technical data of BS 5896-1980
Diameter Diameter Tolerance Cross Section Area mm 52 71 93 139 55 75 100 150 Weight Tensile Strength Minimum Breaking Strength kN 92 125 164 232 102 139 186 265 Minimum Yield Strength at 1% Extension kN 81 110 144 204 90 122 163 233 3.5 < 1.0 < 2.5 < 4.5 3.5 < 1.0 < 2.5 < 4.5 Minimum Elongation to Fracture on 500mm Gauge % Relaxation after 1000hrs 60% Breaking Load % 70% Breaking Load % 80% Breaking Load %

Type

mm 9.3 Standard 11.0 12.5 15.2 9.6 Super 11.3 12.9 15.7

mm +0.30 -0.15 +0.4 -0.2 +0.30 -0.15 +0.4 -0.2

kg/1000m 408 557 730 1094 432 590 785 1180

MPa 1770 1770 1770 1760 1860 1860 1860 1770

Technical data of JIS G 3536-2008


Type Diameter mm 9.3 10.8 12.4 15.2 9.5 11.1 12.7 15.2 17.8 12.8 28.6 Diameter Tolerance mm +0.40 Cross Section Area mm 51.61 69.68 92.90 138.70 54.84 74.19 98.71 138.70 208.40 312.90 532.40 Weight kg/1000m 405 546 729 1101 432 580 774 1101 1652 2482 4229 Minimum Minimum Breaking Yield Strength strength kN 88.8 120 160 240 102 138 183 261 387 573 949 kN 75.5 102 136 204 86.8 118 156 222 330 495 807 Minimum Elongation to Fracture on 500mm Gauge % 3.5 Relaxation after 1000hrs 60% Breaking Load % < 2.5

SWPR7AL

SWPR7BL

-0.20

3.5

< 2.5

SWPR19L

+0.60 -0.25

3.5

< 2.5

Technical data of AS NZS 4672.1-2007


Diameter Diameter Tolerance mm -0.20 +0.40 Cross Section Area mm 52.00 98.60 143.00 190.00 Weight Nominal Tensile Strength MPa 1850 1870 1830 1850 Minimum Breaking Strength kN 102 184 261 353 Minimum Yield Strength kN 85% of minimum breaking strength Minimum Elongation to Fracture on 500mm Gauge % 3.5 Relaxation after 1000hrs 70% Breaking Load % < 2.5 80% Breaking Load % < 3.5

Type

Ordinary

mm 9.5 12.7 15.2 18.0

kg/1000m 432 774 1122 1492

Reference Photos for TMG Low Relaxation PC Strands

Drawn Wire

Drawing Production Line

Stranding Production 01

Strand Production 02

Strand Production 03

Reeling

Packaging

Warehouse

Reference Photos for TMG Low Relaxation PC Strands

PE Strands 01 PE Strands 02

Break Strength Test

Cross Section Magnification Test

Metallurgy Test

Relaxation Test

TMG Wire
TMG High Tensile Strength Wire (Plain, Spiral & Indented)
TMG high tensile strength wire with plain, spiral or indented surfaces is widely used for many precast concrete products and stayed-cable projects. With the infrastructure boom in east Asia, concrete sleepers for railway tracks, concrete electrical poles, hollow-core floor boards for buildings, concrete pipes for water / sewage transportation etc. is driving up the demand for high tensile strength wires. TMGs ability to produce these wires with international standards like ASTM A881, ASTM A421, BS 5896, JIS G3536, AS1310, EN 10138 etc has made us the number one choice in our clients selection for reliable supplier. TMG is also capable of producing galvanized wire.

Indented Wire Plain Wire

Spiral Wire

Technical data of TMG High Tensile Strength Wire (Plain, Spiral & Indented)
Technical data of Spiral Wire
Diameter Diameter Tolerance mm +/- 0.04 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.06 +/- 0.06 +/- 0.06 +/- 0.06 +/- 0.06 12.57 18.10 19.63 21.65 28.27 30.68 38.48 44.18 50.26 63.62 70.88 78.54 113.10 Cross Section Area Weight Tensile Strength MPa 1470 1570 1670 1770 1860 1470 1570 1670 1770 1470 1570 1670 1470 1570 Yield Strength MPa 1290 1380 1470 1560 1640 1290 1380 1470 1560 1290 1380 1470 1290 1380 3.5 Bending Test Minimum Elongation to Fracture on Minimum Bending 200mm Gauge Number of Times Radius % 3 4 4 4 4 4 4 4 4 4 4 4 4 mm 10 15 15 15 15 20 20 20 20 25 25 25 30 2.5 Relaxation after 1000hrs 70% Breaking Load %

mm 4.00 4.80 5.00 5.25 6.00 6.25 7.00 7.50 8.00 9.00 9.50 10.00 12.00

g/m 98.6 142 154 170 222 241 302 347 394 499 556 616 888

Technical data of TMG High Tensile Strength Wire (Plain, Spiral & Indented)
Technical data of Plane & indented Wire
Diameter mm 4.00 5.00 6.00 7.00 8.00 9.00 10.00 Diameter Tolerance mm +/- 0.04 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 +/- 0.05 Cross Section Area mm 12.57 19.63 28.27 38.48 50.26 63.62 78.54 Weight g/m 98.6 154 222 302 394 499 616 Tensile Strength MPa 1470 1570 1670 1770 1860 1470 1570 1670 1470 1570 Yield Strength MPa 1290 1380 1470 1560 1640 1290 1380 1470 1290 1380 Minimum Bending Test Elongation to Fracture on Minimum Number Bending 200mm Gauge of Times Radius % mm 3 10 4 15 4 15 4 3.5 4 4 4 20 20 25 25 2.5 Relaxation after 1000hrs 70% Breaking Load %

Reference Photos of TMG High Tensile Strength Wire (Plain,Spiral & Indented)

Wire Production 01 Spiral Wire

Wire Production 03 Wire Production 02

Reference Photos of TMG High Tensile Strength Wire (Plain, Spiral & Indented)

Galvanized Wire 02 Galvanized Wire 01

Spiral Wire used in Concrete Railway Sleepers

Concrete Railway Sleepers

Water Pipe Hollow Core Slab

TMG PC Bar
TMG PC Bar
TMG produces PC bar under JIS G3137 standard and it is used mainly for the production of spun piles.

PC Bar

Technical data for TMG PC Bar


Technical data of JIS G 3137-1994
Type Diameter mm SBPDN SBPDL 7.1 9.0 10.7 12.6 Cross Section Area mm 40 64 90 125 Weight g/m 314 502 706 981 Tensile Strength MPa 1080 1230 1420 Yield Strength MPa 930 1080 1275 5.0 2.5 Minimum Elongation to Fracture % Relaxation after 1000hrs 70% Breaking Load % 4.0

PC Bar used in Concrete Spun Piles Production Concrete Spun Pile

TMG Global Pte Ltd

8 Jalan Kukoh #01-33 Singapore 162008 Tel : +65 6315 4615 / +65 9684 8728 Fax : +65 6887 5273 Email : sales@tmgglobals.com Website : www.tmgglobals.com

The information set forth in this website including technical drawing and engineering data is presented for general information and as a reference only. While every effort has been made to insure its accuracy, this information should not be used or relied upon for any specific application without independent professional examination and verification of its accuracy, suitability and applicability. Anyone using this material assumes any and all liability resulting from such use. TMG disclaims any and all express or implied warranties of merchantability fitness for any general or particular purpose or freedom from infringement of any patent, trademark, or copyright in regard to the information or products contained or referred to herein. Nothing herein contained shall be construed as granting a license, express or implied under any patents.