Você está na página 1de 3

FCV INTERNAL USE ONLY

MUST NOT BE COPIED

JXFM
PWB Development Section Inventory Date : 06/06/2005 Section Code :

MICROMETER WORK INSTRUCTION BEE

1. Purpose

The micrometer is used to measure the outer dimension of materials, parts, and machined products in 0.01 mm units.

2. Component Names

Anvil

Spindle

Clamp

Measurement scale Thimble

Measurement sides

Sleeve

Ratchet stop Frame

3. Safety Precautions

1) Stand in a comfortable position. 2) Wear gloves as appropriate.

Creation section
STD. No

BEE

JXFM 325/151E
REV DATE 31/12/1998 FCV DATE DESIGN SECTION ENGINEERING CHECK APPR DESIGN BUI KIM KHANH DESCRIPTION CHECK APPR STD DIV FCV Inc. SHEET / 3

FCV STANDARD SHEET

FCV INTERNAL USE ONLY

MUST NOT BE COPIED

JXFM
PWB Engineering Section
4. Inspection Before Work

1) Ensure that no rust and dust is found on the measured surface. 2) Turn the thimble and ratchet stop and make sure that the spindle moves smoothly. 3) Turn the clamp to lock the tool. Turn the ratchet stop and make sure that the ratchet moves. Notes: - If an abnormality is found, do not use the tool. - Do not touch the measurement sides with your bare hand.

5. Measurement Procedure

Note: This section describes the outer dimension micrometer.

1) Select a micrometer according to the measurement target.

Measurement range (mm) 0 to 25 25 to 50 50 to 75 75 to 100

2) Make sure that the micrometer clamp is turned left.

3) Turn the thimble to open the measurement sides wider than the target. Note: Turning the thimble to the left opens the measurement sides and turning it to the right closes the measurement sides.

4) Insert the target between the measurement sides and turn the thimble to the right until the measurement sides come into contact with the target. Then, turn the thimble a half turn to the left .Note: Do not apply any force when the measuring sides are in contact with the target. 5) Turn the ratchet stop right to bring the measurement sides into contact with the target again. Note: Turn the ratchet stopper until the counter stops.

6) Read the counter value 7) Clean the tool: STD. No

Ratchet stop

JXFM325/151E
REV DATE 31/12/1998 FCV DATE DESIGN SECTION BE CHECK APPR DESIGN BUI KIM KHANH DESCRIPTION CHECK APPR CHI ARAI STD DIV FCV Inc. 2 SHEET / 3

FCV STANDARD SHEET

FCV INTERNAL USE ONLY

MUST NOT BE COPIED

JXFM
PWB Engineering Section

Notes: When storing the toll in its case, turn the thimble for the minimum measurement size to plus 2mm and turn the clamp right to lock the tool Clean the measurement sides and spindle particularly. After measurement, replace the tool on the measuring instrument shelf.

6. Reading scales:

1 mm pitch scale 0.01 mm pitch scale 30 35

Note: The above scale is read as: 31 + 0.5 + 0.34 = 31.84

STD. No

JXFM325/151E
REV DATE 31/12/1998 FCV DATE DESIGN SECTION BE CHECK APPR DESIGN BUI KIM KHANH DESCRIPTION CHECK APPR CHI ARAI STD DIV FCV Inc. 3 SHEET / 3

FCV STANDARD SHEET

Você também pode gostar