Você está na página 1de 10

BC.

COMBINED BENDING AND AXIAL FORCES


The axial force could be tension or compression. When the axial load is in compression, the member is probably called beam-column. Guide lines are given in Ch.4 (P.16.1-3) in the manual. Combined force is more critical than tensile axial force. All members in frame are subjected to "combined forces" For column-beam: 1. load deflection plot is nonlinear 2. additional moment results from " P effect" (second order effect)

M = Primary Moment + P , =

PL3 48EI

Design Approach for Member Under Combined Loading (sec.H) Tow cases: Case A axial force is small Case B axial force is not small P Case A: ( Pu small) u < 0.2 Pn

M ux M uy Pu + + 1.0 a (H1-1b) 2Pn M M b nx b ny Pu 0 .2 Case B: ( Pu not small) Pn


Interaction equation Interaction equation

M uy Pu 8 M ux + + 1.0 a (H1-1a) Pn 9 M M b nx b ny

Pn
Eq.H1 - 1a

Pu
Eq.H1 - 1b

0.2Pn 0.9b M n

b M n

BC. 2
For Axial Tension ( Pu tensile):
= required tensile strength (factored) Pu = nominal tensile strength Pn M u = required flexural strength M n = nominal flexural strength x-x axis of bending For compressive force ( Pu comp.), the same interaction formula is applicable, put the value of M ux and M uy must take into account P

(second order effect) Second Order Effect for Beam-Column (Ch.C P.16.1-17) Code allows either to use exact second order elastic analysis or the approximate one in lieu of. Approximate Method: M u = B1 M nt + B2 M lt M nt = Required flexural strength assuming no lateral translation of the frame (no sway) M lt = Required flexural strength as a result of lateral translation of the frame (sidesway) Cm B1 = 1 .0 In plane of bending for braced (1 Pu Pe1 ) frame slenderness parameter 2 Ag Fy F kl E calculated in the plane of y Pe1 = 2 = Ag , c = 2 bending (not necessarily max r E c (kl r ) kl r ) ( k 1.0 ) Value of Cm a) no transverse loading on member between supports: C m = 0.6 0.4( M 1 M 2 ) M1 M2 M1, M2 Moment at the ends ratio M 1 M 2 is +ive if reverse curvature bending L M1 M2 + M 1 M 2 is -ive if ratio M1 M2 reverse curvature reverse curvature bending M 1 M 2 1 .0 L M1 M2 _
single curvature

b) compression member subjected to transverse loading end restrained C m = 0.85 end unrestrained C m = 1.0 More exact value of C m for (b) C m = 1 + Pu Pe1 See P.16.1-187 Table C-C1.1 for & C m values

BC. 3
1 oh 1 Pu HL 1 or B2 = easer Pu 1 Pe 2 B2 =

= required axial strength of all

column in a story o h = lateral inter-story deflection (sway) H = sum of all horizontal producing o h L = story height

Pe 2 =

Ag

2 c
kl r Fy E
,
calculated of bending unsupported frame ( k < 1 )

c =

c is

as

an

Notice that there are two value of Euler load, Pe1 and Pe 2 . Pe1 calculated as braced frame (no side sway) with k 1 Pe 2 calculated as unbraced frame (side sway) with k > 1

The moment magnification for Mu takes place in two parts: one considering no sidesway for all gravity loads and the second considering sidesway under lateral loads

This Mu will be of two components M nt + M lt no sidesway sidesway (gravity loads) (wind loads) factor are same as before, For tension, = 0.9 or 0.75 , for column, c = 0.85 and for beam b = 0.9 Example Investigate the acceptability of W16x67 used as a beam column in a braced frame as shown. P = 87.5k .DL,262.5k .LL , M = 15k '.DL,45k '.LL , Fy = 50ksi
P M P M

Mx

15'

Braced frame (no sidesway). only M nt exist. M lt = 0 Pu = 1.2 DL + 1.6 LL = 1.2 87.5 + 1.6 262.5 = 525k M nt = 1.2M DL + 1.6M LL = 1.2 15 + 1.6 45 = 90k ' M ux (x-axis bending) = B1 M nt

BC. 4
Value of B1
Cm 1.0 , C m = 0.6 0.4( M 1 M 2 ) (1 Pu Pe1 ) k = 1.0 safe C m = 0.6 0.4(0 90) = 0.6 1.0 15 12 kl kl = about axis of bending = = 25.9 r rx 6.96 B1 =
= 8430k (kl r ) 2 25.9 2 Cm 0 .6 B1 = = = 0.64 < 1.0 (1 Pu Pe1 ) (1 525 8430) Thus, B1 = 1.0 Value of c Pn (column design capacity) Pe1 =

2 E Ag

2 29000 19.7

1.0 15 12 kl kl = 73.2 = = r r y 2.46 kl From table, for = 73.2 , c Fcr = 28.70ksi (P.16.1-145) r c Pn = c Fcr Ag = 28.70 19.7 = 565k
Max Value of b M nx (design moment capacity) Unbraced length, Lb = 15' ; take C b = 1.0 from charts, find the capacity for W16x67, with Lb = 15' , b M nx = 430k ' ; Pu 525 = = 0.929 > 0.2 c Pn 565 Use equation H1-1a M uy Pu 8 M ux + + 1.0 (no y-axis bending in this problem) Pn 9 b M nx b M ny M nx = B1 M nt = 1.0 90 = 90.0k ' Interaction equation checking: 252 8 90 + = 0.929 + 0.186 = 1.115 > 1.0 262 9 430 Thus, section W16x67 is not acceptable. Example #2 Determine service load w (40% DL, 60%LL) that can be applied to the member shown below. Ends are simply supported. Lateral support only at ends. A-36 steel. Strong axis bending. P = 20k .DL,40k .LL Factored P = 1.2 20 + 1.6 40 w = 88k P P Let wu = factored ultimate load

20' W12x96

M ux = B1 M nt

BC. 5
wu l 2 wu 20 2 M nt = = = 50 wu k ' 8 8 Cm B1 = ; C m = 1.0 (simplified value with lateral loads) (1 Pu Pe1 ) Pe1 =
1.0 (1 88 4147) Column strength c Pn B1 = kl (kl )x = (kl ) y ; max kl = r r y = 1.0 20 12 = 78 3.09

2 E Ag
(kl r ) 2

(1.0 20 12 5.44)2

2 29000 19.7

= 4147k

c Fcr = 22.22ksi c Pn = c Fcr Ag = 22.22 28.2 = 626.6k Beam strength b M nx


Lb = laterally unsupported length = 15' ; b M nx with C b = 1.0 is 376k ' Interaction equation Pu 88 = = 0.140 < 0.2 c Pn 626.6
M ux Pu M 88 + + ux 1.0 1 .0 2Pn b M nx 2 626.6 376 Or 0.07 + 0.00266M ux 1.0

But

M ux = 349.6k ' M nx = B1 M nt
M nt = M nx 349.6 = = 342k ' B1 1.022 = 50wu = 342 wu = 6.84k / ft

M nt Now wu = 1.2 (0.4 w) + 1.6 (0.6w) = 1.44w (given 40%DL, 60%LL) w Thus, the allowable service load w = u = 4.75k / ft 1.44 Of this total w, DL = 1.9k / ft , LL = 2.85k / ft
DL = 1.9k / ft Total = 4.75k / ft LL = 2.85k / ft

20'

BC. 6
Example #3 Investigate if W14x145 (A-36) can be used as a column in a floor of a single-pay building, considering of lines of column. A single-order elastic analysis was carried out to obtain the results as shown. The combined load shown is DL+LL+WL. The bending is about the major axis and assumes the frame is braced in the weak-axis.
322 26 15 209 104

Remember: For approx. moment magnification method, analysis must be done in two steps: 1. no sidesway with DL+LL loads and 2. sidesway with WL or EQ

13'

13 P

450

i) Column capacity: c Pn k y = 1.0 (Braced)

k x must be calculated using G A and G B for a frame. Assume k x = 1.57 in this example [Remember, k x and k y must be calculated for an actual frame.
considering each axis of bending separately for the frame i.e. from G A , G B and nomograph.]
1.57 13 12 kl = 38.7 = 6.33 r x

1.0 13 12 kl = 39.2 controls = 3.98 r y From table, c Fcr = 28.2ksi c Pn = c Fcr Ag = 28.2 42.7 = 1204k
ii) Beam capacity: b M nx LP = 16.6' < Lb = 13.0' , section compact Thus, M nx = M px

b M nx = b M px = 702k ' from manual

BC. 7
iii) Moment magnification factor B1 & B2 Value B1 (as braced) kl 1.0 13 12 kl about the axis of bending = = 24.6 6.33 r r x C m = 0.6 0.4( M 1 M 2 ) = 0.6 0.4(13 26) = 0.4
(kl r ) 2 Pu = 322 + 15 = 337k B1 = Pe1 =

2 E Ag

2 29000 42.7

(24.6)2

= 20,200k

Cm 04 = <1 (1 Pu Pe1 ) (1 337 20,200) Thus, B1 = 1.0 Value B2 (with sidesway) Pu = 2 322 = 644k

Net vertical load from sidesway = 0

kl kl about the axis of bending = 38.7 (calculated before) r r x 2 E Ag 2 29000 42.7 Pe 2 = = = 8160k (for each axis) (kl r ) 2 (38.7 )2 1 1 = 1.04 B2 = = 644 Pu 1 1 2 8160 P
e2

Thus, M ux = B1 M nt + B2 M lt = 1.0 26.0 + 1.04 450 = 496k ' iv) Check Equation Pu 377 = = 0.28 > 0.2 c Pn 1204
Pu 8 M ux 8 496 = 0.91 < 1.0 OK + = 0.28 + 8 702 Pn 9 b M nx

Thus, W14x145 is OK

BC. 8
Design of Beam-Column If no design aid is available, design is done by "trial-and-error" process. AISC manual provides tables that can be used to quickly design a beamcolumn. (P.6-11) The suggested method is based on using values b, m and n as explained below. 1 Not: ( kip 1 ) b= Proper value of "b" must be used c Pn kl 8 . considering largest value of ( kip ft 1 ) m= r 9b M nx Value of "m" is based on Lb 8 1 ( kip ft ) n= 9b M ny
if Pu 0 .2 Pn Pu < 0 .2 Pn

formula H1-1b controls

bPu + mM ux + nM uy 1.0
if

formula H1-1a controls

1 9 bPu + (mM ux + nM uy ) 1.0 2 8 (Tables 6-12 onwards provides values of b, m and n) Median values for a W-family. Specific values for a given section are given in the following pages.
Example #1 Select a W-shape from W14 family for the following design data: Fy = 50ksi , Pu = 400k , M ux = 350k ' and M uy = 80k ' Median values for W14 with (kl ) y = 14.0' and lb = 14.0' are

(kl )x = (kl ) y

= 14.0' ; unbraced length lb = 14.0'

b = 0.573 10 3 , m = 0.826 10 3 and n = 1.64 10 3 (do median first) Pu P 400 = u = = 0.229 > 0.2 Pn 1 b 1 0.573 10 3 bPu + mM ux + nM uy =
0.573 10 3 400 + 0.826 10 3 350 + 1.64 10 3 80 = 0.65 1.0 Try W14x132 ( b = 0.702 10 3 , m = 1.02 10 3 and n = 2.12 10 3 ) Pu P 400 = u = = 0.28 > 0.2 Pn 1 b 1 0.702 10 3 bPu + mM ux + nM uy = 0.281 + 0.207 + 0.170 = 0.66 1.0 too low
Try W14x99 ( b = 0.939 10 3 , m = 1.38 10 3 and n = 2.88 10 3 ) Pu P 400 = u = = 0.28 > 0.2 Pn 1 b 1 0.702 10 3 bPu + mM ux + nM uy = 0.376 + 0.438 + 0.230 = 0951 1.0 (close to 1.0) Use W14x99

BC. 9
Not: the value of the equation can be found on a calculator quickly to select the best section from a chosen family Example #2 Repeat the same problem for best section For W12, median values are much higher, won't be economical. For W10, section won't exist For W24 ( b = 0.687 10 3 , m = 0.596 10 3 and n = 2.61 10 3 ) To beat W14x99, weight must be less than 99lb / ft W24x99 won't work! Similar scanning can be performed. Best section is W14x99. Example #3 From a first-order elastic analysis, the following service load force are calculated for a column in floor of framed building: DL : Pu = 150k ; M x = 20k ' , M y = 10k '
LL : Pu = 180k ; M x = 35k ' , M y = 15k '

WL : Pu = 5k ; M x = 150k ' , M y = nil

Design the column, assuming that ( DL + LL + WL ) will govern. Fy = 50ksi , l = 16.0' k x = 1.4 and k y = 1.0 ; given C m = 0.50 and B2 = 1.2 Combination DL + LL + WL 1.2 DL + 0.5 LL + 1.3WL Pu = 1.2 150 + 0.5 180 + 1.3 5 = 276.5k M ntx = 1.2 20 + 0.5 35 = 41.5k ' M nty = 1.2 10 + 0.5 15 = 19.5k '

M ntx = 1.3 150 = 195k ' M nly = 0


Needed M ux and M uy :

M ux = B1 M ntx + B2 M ltx M ux = B1 41.5 + 1.2 195 = 41.5 B1 + 234k ' As C m = 0.50 , B1 cannot be more than 1.0 . Take for initial selection B1 = 1.0 , say. Thus, M ux = 41.5 + 234 = 275.5k ' M uy = B1 M nty 1.0 19.5 19.5k ' (assuming B1 = 1.0 about y-axis)
Thus, the design values are: Pu = 276.5k ; M ux = 275.5k ' , M uy = 19.5k ' Ratio (kl )x (kl ) y = 1.4 ; l = unbraced length = 16.0' First consider W14 family Median values (Assuming (kl ) y controls)
Pu < 0 .2 Pn

(kl )x

= 1.4 16 = 22.4' and (kl ) y = 1.0 16 = 16.0' ;

( b = 0.596 10 3 , m = 0.836 10 3 , n = 1.64 10 3 for (kl ) y = 16.0' )

Appears

BC. 10
Interaction equation value 1 9 bPu + (mM ux + nM uy ) = 0.082 + 0.295 = 0.377 1.0 2 8 P If u > 0.2 , value 0.427 Pn By observation/search, try W14x90( b = 1.08 10 3 , m = 1.54 10 3 and n = 3.25 10 3 ) value = 0.786 , for W14x82, value > 1.0 select W14x90 compare with W12 family W14x90 is better. Now, find exact value of (B1 ) x and (B1 ) y and see if the values are 1.0 . If more than 1.0 , correct M ux and M uy by multiplying with B1 .