PAS - Power Analysis Software Copyright (C) 2000-2012, Satec Ltd. Revision History PAS V1.

4 Build 8 ==== - The new USB device driver and library compatible with 32-bit and 64-bi t versions of Windows XP/Vista/7/8 are used (see "Installation notes" for upgrade guidelines). Build 7 ==== - Added support for the SA300N Bay Controller setup, control and monitor ing. - Added support for the EM133-R residential meter. - Added support for the PM180. Build 6 ==== - Added support for the SA300N. - Added support for the EM133. - Added support for IEC 60870-5-101/104. Build 5 ==== - Added - Added - Added - Added - Added lisher. Build 4 ==== - Added GPRS client setup for non-PPP devices. - Added GPRS status and communication counters under Device Control/Communications. - Added licensing for the IEC 61850 server. - Added blocking relays. - Added support for the PM130 PLUS data logging option. - Added support for the EM920. Build 3 ==== - Installation utility gives full folder access permissions to Users gro up to allow standard users changing databases on Windows XP with SP3 and Windo ws Vista. - Database permissions for Users group are restored after compacting dat abases on Windows XP with SP3 and Windows Vista. - Added SNTP client setup.

Transformer correction setup. Transformer/loss compensation setup. TCP notification client for the SA300. blocking direct control ports for the SA300. IEC 61850 setups: Report Deadbands, GOOSE Subscriber, GOOSE Pub

- Added TCP notification client setup. - Added GOST 13109-97 support for the SA300 and EM720. Build 2 ==== - Added GOST 13109-97 support for the PM175. - Added selectable EN 5160 transient overvoltage detection method option . Build 1 ==== - Added multilanguage support (English, Spanish, Russian) - Added support for the EM720. PAS V1.3 Build 11 ======= - Added the fault locator. - Added support for the FOR2007. - Addded support for the PM130 PLUS. Build 10 ======= - Added EN 50160 compliance statistics files upload. - Added EN 50160 compliance statistics reports. - Added IEEE 1159 statistics reports. - Added support for 3 x 16DI modules in the waveform recorder and file u pload. - Added ETC2002 support. - Added an RMS view for fast analog inputs. - Added V4 and I4 harmonic spectrum. - The harmonics table in a harmonic spectrum view displays harmonics bot h in percent and in engineering units. - Reading a data log online can be stopped and resumed at any time while the retrieved data is still visible on the screen. - When uploading a data log, either manually or via the scheduler, only the records logged before the upload has started will be retrieved. - Added the recently used file list that can hold up to 16 last entries. Build 9a ======= Fix: - A site database path could be corrupted when adding a site to the Uplo ad Scheduler list. Build 9 ======= - Added - Added - Added - Added - Added Build 8

showing the waveforms from different sites in a single graph. exporting waveforms and data logs in PQDIF format. support for EGD protocol. support for DNP BC scaling. support for flicker.

======= - Added automatic exporting waveforms in COMTRADE format. Build 7a ======= Fixes: - Uploading/downloading setups from/to a device could cause a program fa ult at the local settings setup. - The data grid in the RMS plot might not be updated when the marker lin e was moving. Build 7 ======= - The SOE log reports from different sites belonging to the same group i n a sites tree can be viewed in a group view in one window - Added support for the EM610 and BFM136 meters. - Added support for the PM172 (new platform) meters. Fixes: - When uploading waveforms using SATEC ASCII protocol, the frequency rea ding could be zeroed. - When uploading files from dial-up sites, PAS closed and restored a con nection after retrieving data from each meter even if the meters are connected to the same modem. - When downloading the memory setup to the PM172E with F/W 4.87 or later , unallocated files could not be recorded. Build 6 ======= Fixes: - Reading databases from network drives could cause errors if the user did not have write access rights. - Saving archived databases with names containing spaces could cause er rors. Build 5 ======= - Added Auto Archive option. - Added DI labels to the Fault Log reports. - Allowed different protocol selection for devices connected through a m odem with the same or different phone numbers. - Allowed remote changing the communication protocol in the PM172 and PM 296 meters. Fixes: - Disabled sorting in the Min/Max log report. - Disabled reading the firmware build register in old meters caused comm unication errors. Build 4 ======= - Amps scale setting in the DNP and Modbus can be programmed at 0.1 amp resolution and is expressed in secondary amps with overload included.

Fixes: - Graph lines color and style settings sometimes might not be saved. Build 3 ======= - Added an Auto Dial option for Dial-Up Network Connections to the ETC20 02. - Added volts and amps scale settings in the DNP and Modbus options setu p for the SA300 with SW versions 10.3.10 and later. - The ODBC data source database is now stored in the PAS installation fo lder instead of the Windows temporary folder that caused security problems for users with restricted access rights on Windows NT/2000/XP. Build 2 ======= - The device address in DNP3 is allowed to be set from 0 to 65532 if the device supports big addresses. Fixes: - DNP Events Setup could be unavailable in Off-line mode if the setup wa s not previously accessed On-line. - Corrected zooming and printing very long (over 1024 cycles) waveforms. - Restored saving data log tables in an ASCII .snl file format. Build 1 ======= - Revised the user interface, toolbars and icons. - Added customized fonts in tables. - The table grids are automatically expanded to the window size and the print page width. - Added the Modbus flash download utility for the FPD280. - Added user definable names for data logs. - Line to neutral voltage waveforms can be converted to line to line vol tages. - Improved PAS performance for viewing very large (over 1 Gigabytes) wav eform tables. - The Voltage disturbance trigger limit for the PM295/296/172EH is now s tored to the site database in percent rather than in volt units, regardless of the user preference. The user can view the trigger limit in his preferred un its, either in percent or in volts. PAS will try to automatically convert and store limits in a new format when the setpoint setup is open. Anyway to avoid errors, the Event/Alarm setpoints stored to the database should be checked for t he Voltage disturbance trigger limits before downloading to the device. - All communication ports are closed after the upload scheduler complete s its periodic scan to allow other user applications to access the ports.

PAS V1.2.5 Build 26 ======== - Voltage waveforms for the 3DIR2 wiring configuration recorded to the w aveform log file #1, are shown now for line to line voltages and not for line to neutral voltages as it was before. - Improved uploading and decoding overlayed waveforms. Build 25 ======== - Analog Inputs AI1-AI16 and Digital Inputs DI1:16 are allowed to be sel ected for the SA300 fault and PQ data log files (starting with firmware releas e 10.3.7). - Analog Inputs AI1-AI16 and Digital Inputs DI1:16 are added to the hist orical data log and real-time data monitor trends. - User defined labels are added to digital channels' names in the Wavefo rm screen. - User defined labels are added to analog input and digital input channe l names in the data trend screen. - Automatic adjusting of a zero offset is allowed for waveforms uploaded from the PM295. - Corrected print and copy layouts for waveform screens. - The device firmware version and serial number are displayed in the sit e properties if the device is available on-line. - The Power Quality and Fault recorders can only be enabled/disabled fro m the corresponding setup menu. The device control dialog will only show the p resent recorder mode. - The DNP setup for the SA300 is allowed to be done in Modbus (with Firm ware V10.3.8 and later). - Added communication setup and password checking for the SA300 through DNP3 (with Firmware V10.3.8 and later). Build 24 ======== - Added FPD280 TOC curves for new types of the simulated protection rela ys. - Added a frequency plot window to the waveform graph views. - The Basic Setup dialog for the SA300 is split into two tabs: Basic Set up and Advanced Setup. - The waveform graphic windows can show up to 1024 waveform cycles in th e visible area without scrolling.

Fixes: - PAS could crash if the spectrum window was opened from another graphic window in a full screen size. - The Delta cursor could point to wrong coordinates in the graphic windo ws with the vertical scroll bar. Build 23 ======== - Added support for the FPD280. - Added support for COM ports above COM9. Build 22 ======== - Added the delta operator for SA300 setpoints. The trigger generates an event when the tested value and the last reported value differ by a programmab le deadband. - The Protocol setup data can be downloaded to the device along with oth er setups by a single command. Fixes: - The DNP Options setup could require a number of retries to be entirely recorded to the device. - In DNP mode, the Data Monitor window could show incorrect readings for digital inputs and relays. - In DNP mode, the Data Monitor window could use incorrect scaling for a nalog values with the SA300. Build 21 ======== - Added the broken delta wiring configuration. - A phone icon is shown on the status bar while the modem connection is open. Fixes: - All events in the SOE Log window were displayed in the colors preset f or the first event label. Build 20 ======== - Added harmonic limits in the Spectrum Chart and Spectrum Table windows . - Added a programmable transmission delay in the protocol setup dialog t o increase the interval between consequent requests for slow communication devices. Fixes: - PAS could report "Device doesn't respond" for devices other than the S A300, if the number of retries in the protocol setup was more than 1. - Opening waveform tables created by PAS V1.2.5 Build 02 could cause cra sh

of PAS. Build 19 ======== - Added support for the SA300 Expanded Memory Module. Build 18 ======== - Added Harmonic Monitor window for the C191HM. - Added selective uploading waveforms for PQ, Fault, SOE and setpoint ev ents. Fixes: - For the PM295, the error message "Data is not available in this instru ment" was reported when restoring or uploading the data logs #9 to #16. Build 17 ======== - Added event color selection for the Sequence-of-Events reports. - Allowed copying of separate panes in graph windows. Fixes: - Fixed printing problems in graph windows. Build 16 ======== - Added cross-links to all event reports that directly link events to th e related waveforms and event data. - The vertical scales in trend windows are set the same for similar data quantities. - Added reference trigger thresholds in volts and amps to the Fault Reco rder setup dialog. - Added spectrum charts for extended range (150A) currents. - Allowed simultaneous connections to Modbus/TCP and DNP3.0/TCP servers. Fixes: - Fixed data retrieving problems with PM100 and PM200 series meters. Build 15 ======== - Retrieving logs on-line is started automatically when the log window i s open while the On-line icon is checked. - Added links to the PQ Log window that directly link the power quality events to the corresponding waveforms. Fixes: - Sometimes, the waveform window could not correctly show the secondary volts for channel V1. Build 14 ======== - Added the Delta time and magnitude measurements between two waveform p oints.

- Added the Auto Run (automatic polling) option to the RT Data Monitor a nd RT Waveform Monitor. Build 12 ======== - Added a selectable Time Range for data trends. - The TOU Calendar setup for the SA300 is now compatible with the setup for other devices. Fixes: - Reading TOU Calendars from the SA300 returned two first calendars from ten. - The Spectrum Graph and Spectrum Table windows did not show correct dat a if none of Waveform windows is open. Build 11 ======== Fixes: - When reading the SEO log stored to a file, PAS could clear the lower 8 bits of the millisecond part in the timestamp, so that millisecond readings were 0, 256, 512 or 768. - The timestamp in RT Data Monitor and Min/Max Log Monitor records did n ot account for daylight savings time if the "Automatically adjust clock for daylight saving changes" box in Date/Time Properties->Time Zone settings is checked. Build 10 ======== - Local controls used in the monitor and log windows are moved onto loca l window toolbars - Added Device Diagnostics tab to the Device Control dialog. Build 9 ======= - Added option to the waveform windows allowing to show time axes in absolute or relative time. - Added point labels and descriptions for SOE log. Fixes: - Communications settings were not available if the PC did not have a modem installed. - Setup data in the site databases were depended on the locale settings on a PC. Build 8 ======= - Added a data trend window to the RT Data Monitor. Fixes: - When communicating to multiple meters via Scheduler through a modem, PAS could not properly dial phone numbers for the following sites if the meters were connected to different modems.