04.23.01 0502 na
Installation
Construction
Positive Electrode
Pocket plate
Negative Electrode
Pocket plate
Separation
Rod separator
Casing Material
Polystyrene 475 K
Electrolyte
Potassium hydroxide
d = 1.19 kg/l
Terminal Design
Pole Screw
Connectors
Vent Plugs
Charging
Temperature Range
-20o+45oC
(Preferred value 20oC)
Features
VHB Industrial Batteries Ltd. 72 Devon Road, Unit 22, Brampton, Ontario L6T 5B4
Tel: (905) 790-0730 1-888-VHB-BATT Fax: (905) 790-0744 E-mail: vhbbatt@vhbbatteries.com
Technical data
Type
C5
Internal
C0.25
Final voltage
Us/V
designation
TSP 7.5
TSP 10
TSP 14
TSP 20
TSP 30
TSP 40
TSP 55
TSP 65
TSP 80
TSP100
TSP125
TSP150
TSP185
TSP200
TSP235
Capacity (Ah)
C3
C1.5 C1
resistance
Short
circuit
(mm)
W
46
46
46
46
86
86
54
70
70
105
105
108
165
165
165
86
86
86
86
86
86
134
134
134
137
137
165
158
158
158
current
without conn., charged
1.15
1.10
1.05
1.00
0.85
[mOhm/cel]
[A]
7.5
10.0
14.0
20.0
30.0
40.0
55.0
65.0
80.0
100
125
150
185
200
235
7.3
9.8
13.7
19.5
29.3
39.0
53.7
63.3
78.0
97.8
122
147
181
196
230
8.25
11.0
15.3
21.9
32.9
43.8
60.2
71.1
87.6
110
137
164
203
219
257
7.5
10
14
20
30
40
55
65
80
100
125
150
185
200
238
5.08
6.75
9.45
13.5
20.3
27
44
52
64
80
100
120
148
160
188
10.7
8.00
5.71
4.00
2.67
2.00
1.46
1.23
1.00
0.80
0.64
0.53
0.43
0.40
0.34
120
165
230
325
490
650
895
1055
1300
1625
2030
2440
3005
3250
3820
Cell dimensions
(inch)
*
H
L
W
Weight
H
[kg]
[lb]
Cell
Cell
190
260
260
260
260
260
360
360
360
360
360
405
405
405
405
1.81
1.81
1.81
1.81
3.39
3.39
2.13
2.76
2.76
4.13
4.13
4.25
6.50
6.50
6.50
3.39
3.39
3.39
3.39
3.39
3.39
5.28
5.28
5.28
5.39
5.39
6.50
6.22
6.22
6.22
7.48
10.24
10.24
10.24
10.24
10.24
14.17
14.17
14.17
14.17
14.17
15.94
15.94
15.94
15.94
1.10
1.62
1.60
1.90
3.05
3.59
4.15
5.83
6.72
9.00
9.81
14.0
17.6
18.3
19.4
0.20
0.51
0.40
0.34
0.77
0.61
0.92
1.41
1.20
2.54
2.25
3.40
5.70
5.38
4.87
2.4 0.4
3.6 1.1
3.5 0.9
4.2 0.7
6.7 1.7
7.9 1.3
9.1 2.0
12.9 3.1
14.8 2.6
19.8 5.6
21.6 5.0
30.9 7.5
38.8 12.6
40.3 11.9
42.7 10.7
The electrical values shown in the table relate to loadings from a fully charged condition and an ambient temperature of +20C.
Height includes connectors.
20"
30"
1'
3'
5'
10'
15'
20'
30'
1h
1.5h
3h
5h
43.0
57.0
80.0
114
171
228
258
305
376
470
587
705
869
940
1105
41.0
54.0
76.0
108
162
216
236
279
344
430
537
645
795
860
1011
38.0
50.0
70.0
100
150
200
225
266
328
410
512
615
758
820
963
35.0
46.0
64.0
92.0
138
184
220
260
320
400
500
585
721
780
916
28.0
37.0
52.0
74.0
111
148
176
208
256
320
400
480
592
640
752
23.0
31.0
43.0
62.0
93.0
124
154
182
224
280
350
420
518
560
658
18.0
24.0
33.6
48.0
72.0
96.0
132
156
192
240
300
360
444
480
564
16.5
22.0
30.8
44.0
66.0
88.0
121
143
176
220
275
330
407
440
517
15.0
20.3
28.0
40.0
60.0
80.0
110
130
160
200
250
300
370
400
470
11.3
15.0
21.0
30.0
45.0
60.0
82.5
97.5
120
150
187
225
277
300
352
7.20
9.60
13.40
19.20
28.80
38.40
52.80
62.40
76.80
96.0
120
144
177
192
225
5.3
7.1
9.9
14.2
21.3
28.4
39.0
46.1
56.8
71.0
88.8
107
131
142
167
2.44
3.25
4.55
6.50
9.75
13.0
17.9
21.1
26.0
32.6
40.8
48.9
60.4
65.2
76.6
1.50
2.00
2.80
4.00
6.00
8.00
11.0
13.0
16.0
20.0
25.0
30.0
37.0
40.0
47.0
The electrical values shown in the table relate to loadings from a fully charged condition at ambient temperature of +20C.
In the project planning data table connector losses are taken into account.
TSP 30 - TSP 40
TSP 65 - TSP125
TSP150 - TSP235
All dimensions and weights shown are subject to the usual manufacturing tolerances. Electrical values are approximate.
The right is reserved to make alterations with a view to technically improved execution without prior notice.
04.23.01 0502 na