Concrete
1000
800
75
75
40
25
b
h
rt
rb
fck
c
mm
mm
mm
mm
Mpa
KN/m3
Width of slab
Depth of slab
Top cover
Bottom cover
Strength of concrete
Unit weight of reinforced concrete
Reinforcement
Es
fyk
200,000 Mpa
500 Mpa
Modulus of elasticity
Yield strength of reinforcement
EUROCODE 2 PARAMETERS
fctm
Ec
Ecm
3.5 N.mm2
37.0 KN.mm2
35.2 KN.mm2
10.4 KN.mm2
2.56
19.3 Cracked
5.7 Uncracked
Kc
K
0.4
0.65
Kt
K1
K2
0.4
0.8
0.5
K
cs
L
0.5
0.104
4.7E-04
12000 mm
Ec,eff
(, t0)
e
ae
As, min
Cracking
Duration load factor
Bond poperties (Section 7.3.4)
Strain distribution ratio (Section 7.3.4)
Deflection
Coefficient of influence of the duration or repeated loading (Section 7.4.3)
Typical deflection coefficient (See table 6.14, Mosley page 142)
Free srinkage strain (Section 3.1.4)
Span
Mu
shear
s
c
d
K
Zu
As
As,min
As,max
(+)
770.0
14.0
1.15
1.50
695.0
0.040
0.670
2,645
1,268
32,000
DESIGN OF REINFORCEMENT
MAIN ( // X-X M11)
Edge / Over Pilot
(-)
(+)
(-)
242.0
1223.0
1455.0
14.0
14.0
14.0
1.00
1.00
1.00
1.20
1.20
1.20
698.5
693.5
693.5
0.012
0.064
0.076
0.692
0.661
0.654
699
3,701
4,448
1,274
1,265
1,265
32,000
32,000
32,000
(+)
957.0
14.0
1.15
1.50
660.0
0.055
0.626
3,514
1,204
32,000
(-)
360.0
14.0
1.00
1.20
660.0
0.021
0.650
1,107
1,204
32,000
(+)
800.0
14.0
1.00
1.20
660.0
0.046
0.638
2,508
1,204
32,000
(-)
1560.0
14.0
1.00
1.20
660.0
0.090
0.615
5,071
1,204
32,000
As required
2,645
1,274
3,701
3,514
1,204
2,508
5,071
mm
32
300
25
300
35
200
4,448
Provided Reinforcement
35
200
32
300
32
300
2681
ok
1%
1636
ok
28%
4811
ok
30%
4811
ok
8%
32
300
25
300
4317
ok
23%
2681
ok
123%
2681
ok
7%
32
300
32
300
5362
ok
6%
mm
mm
mm
mm
2
mm
2681
424.0
1636
4811
SERVICEABILITY REQUIREMENTS
4811
-486.0
4317
615.0
2681
2681
5362
916.0
xc
Ic
cc
st
221.2
1.5.E+10
6.2
254.6
180.6
1.2.E+10
0.0
0.0
277.6
2.0.E+10
0.0
0.0
277.6
2.0.E+10
-5.8
-168.1
258.4
1.7.E+10
8.3
248.2
214.5
1.4.E+10
0.0
0.0
214.5
1.4.E+10
0.0
0.0
280.1
1.9.E+10
11.5
301.5
mm
mm4
Mpa
Mpa
xu
Iu
405.5
4.4E+10
403.4
4.3E+10
409.7
4.5E+10
409.7
4.5E+10
407.7
4.4E+10
404.9
4.4E+10
404.9
4.4E+10
409.5
4.5E+10
mm
mm4
Direction
Centre Slab
Location
Design bending moment
Size of shear reinforcement (for d calculation)
Safety factor on steel
Safety factor on concrete
Effective depth
Level arm
Area of tension reinforcement required
Minimum area of tension reinforcement
Maximum area of tension reinforcement
Provided reinforcement
S
Asp
Verif
As of calculation
Msls caracteristic
Cracked section
Neutal axis of cracked section
Moment of inertia of cracked section
Stress in compresed concrete <0.6 fck
Stress in the tension steel <0.8 fyk
Unracked section
Neutal axis of uncracked section
Moment of inertia of uncracked section
mm
m
2
mm
2
mm
2
mm
2
Cha
Servic
0.00
0.00
0.00
723.6
Direction
Centre
Location
As provided
Msls quasi-permanent
(+)
2681
59.0
(-)
1636
263.0
0.00
0.00
0.00
712.2
SERVICEABILITY REQUIREMENTS
MAIN
Edge
(+)
4811
31.0
-4.22
-4.43
-17.43
712.2
cracking occurs
5.66
19.90
715.7
(-)
4811
118.0
(+)
4317
167.0
0.00
0.00
0.00
721.0
0.00
0.00
0.00
721.0
cracking occurs
8.40
29.18
712.4
Mpa
Mpa
Mpa
2
mm
(-)
5362
257.0
mm2
KN-m
SECONDARY
Centre
Edge
(-)
2681
257.0
(+)
2681
40.0
Quasi-permanent (1Gk+0.3Qk)
Fundamental (1.35Gk + 1.5Qk)
Design shear
Effective depth
Reinforcement Ratio
Shear Coefficient
Shear reristance without reinforcement
Design value of shear force
xc
180.6
277.6
277.6
258.4
214.5
214.5
280.1
mm
1.5E+10
0.9
35.4
0.0139
0.00011
32.0
694
0.07
1.0E+10
4.6
251.8
0.0079
0.00076
25.0
839
0.63
2.3E+10
0.4
10.7
0.0276
0.00003
35.0
518
0.02
2.3E+10
1.4
40.8
0.0276
0.00012
35.0
518
0.06
1.9E+10
2.3
67.4
0.0239
0.00020
29.0
633
0.13
1.4E+10
4.1
162.9
0.0137
0.00049
32.0
818
0.40
1.4E+10
0.6
25.4
0.0137
0.00008
32.0
818
0.06
2.2E+10
3.2
84.6
0.0309
0.00025
32.0
597
0.15
mm4
Mpa
Mpa
M cr
I
Il
1/rus
1/rcs
1/r
T
a
391.1
0.00
1.29E-07
3.74E-07
1.29E-07
1.60E-07
7.57E-07
1.60E-07
2.89E-07
4.3
384.7
0.00
5.82E-07
2.43E-06
5.82E-07
1.00E-07
7.36E-07
1.00E-07
6.83E-07
10.2
404.0
0.00
6.64E-08
1.29E-07
6.64E-08
2.75E-07
7.82E-07
2.75E-07
3.41E-07
5.1
404.0
0.00
2.53E-07
4.91E-07
2.53E-07
2.75E-07
7.82E-07
2.75E-07
5.28E-07
7.9
396.0
0.00
3.63E-07
8.39E-07
3.63E-07
2.23E-07
8.19E-07
2.23E-07
5.86E-07
8.8
387.8
0.00
5.66E-07
1.83E-06
5.66E-07
1.42E-07
7.99E-07
1.42E-07
7.08E-07
10.6
387.8
0.00
8.82E-08
2.85E-07
8.82E-08
1.42E-07
7.99E-07
1.42E-07
2.30E-07
3.4
401.2
0.00
5.54E-07
1.11E-06
5.54E-07
2.72E-07
8.29E-07
2.72E-07
8.26E-07
12.4
SHEAR RESISTANCE
Vu
d
k
VRd,c
1438
711
0.4%
1.53
323
reinforcement needed
Ved
1438
Vrd max teta22
2987
Vrd max teta45
teta calcul
As/s
As/s min
As/s required
Calculation method (1 or 2)
spacing
Type reinforcement (links "l" or stirrups "s")
Max spacing of shear reinforcement
221.2
Ic
cc
st
p,eff
sm-cm
eq
Sr,max
Wk
s
min phi s
PUNCHING RESISTANCE
Vu
dx
dy
d
x
y
r
k
a
b
u
VRd,c
Vrd max
Vrd
4300
22
2095
1012
2095
1
300
S
20.0
1762
713
713
713
0.32%
0.32%
0.3%
1.53
500
500
10960
3353
9583
3353
no reinforcement required
KN
mm
KN
KN
KN
KN
mm2/m
mm2/m
mm2/m
mm
mm
kN
mm
mm
mm
mm
mm
mm
kN
KN
KN
mm
mm
mm
KN-m
mm
mm
mm
mm
mm
mm
mm
mm