README FIRST
README: Remove Failed Disks before the Disk Re-assignment
No "Failed" Disks can exist in the system for the disk assignment to the new controller to properly execute.
Enter: 'partner aggr status -f ' on the partner node that took over. The word (takeover) is in the console prompt. If there
are failed disks, they must be removed or replaced before the disk reassignment process. Continue with README R2.
System is HA and the partner took over: The disk reassignment should be only be executed when the 'giveback' can
also be executed - Confirm with end-user that the 'giveback' can be executed immediately after the disk
reassignment. If the giveback needs to be scheduled, defer the disk reassignment - Continue with next step.
After the initial 'giveback' is completed from the partner node, the workaround requires logging into the " target" (repaired)
node and executing a controller 'takeover'. Then when the takeover is complete, a 'giveback' is executed to finish the
process of updating the disk ownership caches on both nodes. This AP has been updated to include these steps.
Skip this section if the system is running any version of DOT 7.x, 8.0.2P2, 8.0.3, 8.1RC2 or higher, otherwise continue.
README: Process Change in the Disk Re-assignment and Giveback Sections (Bug 490825)
The partner must have taken over the "target" (down) controller. If a takeover did not occur, skip to next page.
If the system configuration is unknown, follow Section III of this AP to assist in determining if controller is HA and if
the partner took over. If the system is not HA or the partner did NOT takeover, skip to next page.
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
I. Appliance/NVRAM Adapter Visual Checks
II. Node Pre-Checks
III. Node State Check and Shutdown Procedure IX. Boot Diagnostics and test the NVRAM Memory
IV. Capture the Current System Configuration X. Capture new System-ID on replacement NVRAM
V. Locate the NVRAM Adapter and the Internal Red LED XI. Disk Reassign
XII. Boot the Operating System - 'cf giveback' if applicable
XIII. Submit logs and Part Return
VII. Replace the NVRAM Adapter
I.
Step
1 Visually verify if you are working on correct model and READ the CAUTION note below.
Fig 1
Fig 2
Fig 3
Click here
for larger view
2 Go to Section II, "Node Pre-Checks" on next page.
SA600 and V-FAS6000 Series: NVRAM Adapter Visual Checks
Action Description
Page 1 of 15
SECTION OUTLINE for the SA600 and V-FAS6000 Series NVRAM Adapter Replacement
This procedure will take 60-90 minutes
Open the System: Remove the Cables, Cable Management
Tray and extract the System Tray
VI.
Close the System: Reinsert the System Tray and reconnect
the cables
VIII.
STOP !!
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
6u
SA600 or V-FAS Model Number
System Serial Number
IOIOI (Console) Port
PS-2 AC
Switch
PS-1 AC
Switch
FC Port Tray ( 0a-0b, 0c-0d, 0e-0f, 0g-0h )
6 Ethernet
Ports
( e0a-e0f )
NVRAM6 Adapter
RLM Port
CAUTION
If the Data in NVRAM red LED is flashing through the faceplate when power is turned off,
uncommitted customer data may be in the NVRAM . Follow this action plan carefully.
Data in NVRAM LED:
Is a Red LED located
behind the Faceplate.
Activity, Status (!), Power LEDs
Activity LED should be OFF!
NVRAM DATA LED:
Located behind the
faceplate.
Fig 4
II.
Step
1
2 Adhere to anti-static precautions. (A paper ESD strap is included inside the RMA box if you don't have your own)
STOP
3 Remove the replacement NVRAM from the anti-static bag and examine the connectors for damage.
III.
Step
To review the J ob Aid on how to connect to console (IOIOI) port and serial emulator options, here >> Console Attach
2
a)
S
T
O
P
3 The target node needs to be halted or " waiting for giveback" for this part replacement. LCD Detail >> LCD Panel
4 Confirm the console response is " LOADER>" or " Waiting for giveback" . If it is " LOADER>" , go to Section IV.
5 If the console response is: " Waiting for giveback..." follow steps 5a-5c.
a) At the "Waiting for giveback " prompt, Press: Ctrl-C
b) At the message: "Do you wish to halt this node rather than wait [y/n]? " Enter: "y"
c) After the system drops to the LOADER> prompt, continue with next section.
6 Go to Section IV, "Capture the Current System Configuration" on next page.
1 Always capture the nodes console output to a text file, ex: NetApp-dispatch-num.txt , even if using the end-user's computer.
SA600 and V-FAS6000 Series: Node Pre-Checks
Action Description
Verify the " Order Reference 8xxxxxxxxx number on the RMA packing slip is the same as the Part Request (PREQ) number
listed in your dispatch notes.
Page2 of 15
This procedure is for a NVRAM6/Cluster interconnect card. If the part # on the RMA packing slip contains " 1926" in it,
the part is a VI-MetroCluster card and this is not the proper action plan. See VI-MetroCluster AP.
WARNING for HA (Active-Active) configurations:
If the failure has caused a controller failover you may have been dispatched on the surviving controller's serial number, not the
failed one. If the LCD panel displays the word " takeover" or " cf takeover" , this node it UP. See Explanation of LCD panel
messages in the link in Step 3.
Action Description
SA600 and V-FAS6000 Series: Node State Check and Shutdown Procedure
Walk up visual observation checks - Identifying the correct node to be serviced, i.e.. the "target" node.
NOTE: A "controller failover" will turn the Status ( ! ), middle LED from GREEN to AMBER on the target and partner nodes.
The " Activity" ( ) LED, left most in figure, on the target node should be OFF. If it is flashing, this node is still up - or you
are looking at the partner node, not the target node. See STOP message.
The (Activity) LED should be off.
No flashing on the target node.
! (Status) LED will turn from
GREEN to AMBER on the target
and partner node if a controller
" failover" has occurred.
Wai t i ng f or gi veback. . . ( Pr ess Ct r l - C t o abor t wai t )
Wai t i ng f or gi veback. . . ( Pr ess Ct r l - C t o abor t wai t )
^C
Thi s node was pr evi ousl y decl ar ed dead.
Pausi ng t o check HA par t ner st at us . . .
par t ner i s oper at i onal and i n t akeover mode.
You must i ni t i at e a gi veback or shut down on t he HA
par t ner i n or der t o br i ng t hi s node onl i ne.
The HA par t ner i s cur r ent l y oper at i onal and i n t akeover mode.
Thi s node cannot cont i nue unl ess you i ni t i at e a gi veback on t he par t ner .
Once t hi s i s done t hi s node wi l l r eboot aut omat i cal l y.
wai t i ng f or gi veback. . .
Do you wi sh t o hal t t hi s node r at her t han wai t [ y/ n] ? y
Hal t i ng. . .
Upt i me: 3m10s
Syst emhal t i ng. . .
LOADER>
Step 5: Hitting Enter
displays this prompt
Step 5a): Enter: CTRL-C
Information on
Partner Status
Step 5b): Enter: " y"
Fig 5
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
IV
Step
1 a)
b) From the LOADER> prompt enter " autoboot" to initiate a prom bootstrap.
c)
d) Enter "5" for "Maintenance mode boot".
e) If asked " Continue with boot?" Answer: "y"
2 Continue with Section IV on next page.
Page 3 of 15
SA600 and V-FAS6000 Series: Capture the Current System Configuration
Action Description
NOTE If the Motherboard fails to boot to the Maintenance menu due to an error, skip to Section V.
Reference the example of console output below and follow these steps. The .. (dots) represent deleted text to highlight
the specific output messages to key on.
When this message appears: " Press CTRL-C for boot menu" , press CTRL-C (^C) to load the " Boot options menu" .
After about 30-40 seconds, the " Maintenance menu" will appear.
LOADER> autoboot
Loadi ng X86_64/ f r eebsd/ i mage1/ ker nel : 0x100000/ 3375736 0x538280/ 3221872
. . . . .
Copyr i ght ( C) 1992- 2010 Net App.
Al l r i ght s r eser ved.
*******************************
* *
* Press Ctrl-C for Boot Menu. *
* *
*******************************
^CBoot Menu will be available.
Pl ease choose one of t he f ol l owi ng:
( 1) Nor mal Boot .
( 2) Boot wi t hout / et c/ r c.
( 3) Change passwor d.
( 4) Cl ean conf i gur at i on and i ni t i al i ze al l di sks.
( 5) Mai nt enance mode boot .
( 6) Updat e f l ash f r ombackup conf i g.
( 7) I nst al l new sof t war e f i r st .
( 8) Reboot node.
Sel ect i on ( 1- 8) ? 5
You have sel ect ed t he mai nt enance boot opt i on:
. . . . .
. . . . .
I n a Hi gh Avai l abi l i t y conf i gur at i on, you MUST ensur e t hat t he par t ner node i s ( and r emai ns) down, or t hat
t akeover i s manual l y di sabl ed on t he par t ner node, because Hi gh Avai l abi l i t y sof t war e i s not st ar t ed or
f ul l y enabl ed i n Mai nt enance mode.
FAI LURE TO DO SO CAN RESULT I N YOUR FI LESYSTEMS BEI NG DESTROYED
NOTE: I t i s okay t o use ' show/ st at us' sub- commands such as ' di sk show or aggr st at us' i n Mai nt enance mode
whi l e t he par t ner i s up
Cont i nue wi t h boot ? yes
. . . . .
. . . . .
. . . . .
*>
Step 1b): Enter " autoboot"
Step 1d): Enter " 5"
Step 1e): If this node has a partner node this
message will be displayed. Answer: "y" .
maintenance mode console prompt
Step 1c): Wait for
this message, then
hit ^C (CTRL-C)
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
IV
Step
3 Next, from the *> prompt enter " disk show -v" to view which SAS and FC Adapter ports are driving disks- See Text Box 3 below.
include switch paths for it's virtual storage. Example of McData and Cisco switch paths here >V-Series Disk Show
4
5 At the >*>prompt enter " halt" (after prom initialization the console will display the LOADER> prompt)
6 Go to Section V, "Locate the NVRAM Adapter and the Internal Red LED" on next page.
Take note of all the "unique" Adapter port numbers displayed. See Text Box STEP 4. In this example: SAS Adapters 5a, 5c and
FC Adapters 0c, 0d are displayed.
Page 4 of 15
SA600 and V-FAS6000 Series: Capture the Current System Configuration (cont.)
Action Description
NOTE
The " disk show -v" sample output below is abbreviated console output. If DOT 8.x, a HOME column is also listed with
OWNER for each disk, which displays the node's systemname (and system-ID). After the controller is replaced it is
necessary to confirm each SAS/FC Adapter port is seeing its storage. If a V-Series (V6000), the 'disk show -v' will
*> disk show -v
Local Syst emI D: 1573753606
DI SK OWNER POOL SERI AL NUMBER HOME
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
5c. 02. 4 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7VRRF f as6040cl 2- ams( 1573753632)
5c. 02. 3 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7WMNQ f as6040cl 2- ams( 1573753632)
5c. 02. 10 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7WF87 f as6040cl 2- ams( 1573753632)
5c. 02. 20 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7WMNE f as6040cl 2- ams( 1573753632)
5c. 02. 19 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7WWR4 f as6040cl 2- ams( 1573753632)
5c. 02. 6 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7W80G f as6040cl 2- ams( 1573753632)
5c. 02. 16 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7WSH9 f as6040cl 2- ams( 1573753632)
5c. 02. 7 f as6040cl 2- ams( 1573753632) Pool 0 9QJ 7W3KA f as6040cl 2- ams( 1573753632)
. . . . .
. . . . .
0d. 41 f as6040cl 2- ams( 1573753632) Pool 0 J LVT29GC f as6040cl 2- ams( 1573753632)
0d. 43 f as6040cl 2- ams( 1573753632) Pool 0 J LVT7BUC f as6040cl 2- ams( 1573753632)
0d. 33 f as6040cl 2- ams( 1573753632) Pool 0 J LVS4EHC f as6040cl 2- ams( 1573753632)
. . . . .
. . . . .
0c.21 f as6040cl 1- ams( 1573753606) Pool 0 J LVT0KDC fas6040cl1-ams(1573753606)
0c.18 f as6040cl 1- ams( 1573753606) Pool 0 J LVT2HZC fas6040cl1-ams(1573753606)
0c.28 f as6040cl 1- ams( 1573753606) Pool 0 J LVS585C fas6040cl1-ams(1573753606)
. . . .
5a.01.13 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7W3XZ fas6040cl1-ams(1573753606)
5a.01.21 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7WSX8 fas6040cl1-ams(1573753606)
5a.01.16 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7W3YT fas6040cl1-ams(1573753606)
5a.01.12 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7WS0R fas6040cl1-ams(1573753606)
5a.01.14 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7W8GM fas6040cl1-ams(1573753606)
5a.01.18 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7WX7E fas6040cl1-ams(1573753606)
5a.01.22 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7WY15 fas6040cl1-ams(1573753606)
5a.01.11 f as6040cl 1- ams( 1573753606) Pool 0 9QJ 7W8N2 fas6040cl1-ams(1573753606)
. . . . .
. . . . .
*>
*> halt
A typical listing will display many
more disks and FC/SAS adapters
than this partial listing. Step 5: Enter " halt" to exit to the LOADER> prompt
Step 3: The disk show -v command prints out
the System ID of the Local System (1573753606). It also
prints the owner of each disk under the HOME heading
which lists the node's system name. This system name is
(fas6040cl1-am) and owns disks: 0c.21, 0c.18,
0c.28,5a.01.13, 5a.01.21, etc.
NOTE- Partner owned disks are intermixed in the
output. The partner hostname is 'fas6040cl2-ams' and
it's System ID is (1573753632).
Example Only
Step 4: Under the DISK heading, all SAS &
FC Adapters are listed. In this example SAS
adapter 5a and 5c and FC adapter ' 0c and
0d' are seen, but typically there are more.
After the controller is replaced, confirm the
same adapters are listed meaning there is an
active SAS/FC path to the disks.
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
V.
Step
1
STOP
2
An internal view of the NVRAM LED is here >> NVRAM6-LED
3
a)
4
a)
VI.
Step
Note Appliance should have been " halted" and then powered off with power cables removed.
1 Label each cable connector with its port number and then unplug all the cables.
Note If possible keep the cables in the cable clips on the cable tray to keep them in the correct position for reconnection.
2
3 Continue with Section VI on next page.
Page 5 of 15
SA600 and V-FAS6000 Series: Locate the NVRAM Adapter and the Internal Red LED
Action Description
Confirm the console response is " LOADER>" . Next turn off both power supplies (Refer to Fig 2 in Section I.) on the back of the
head unit and disconnect the power cords from the power supplies.
(i) The dispatch should indicate which slot the NVRAM6 is installed; 1 or 2.
(ii ) INVRAM is slot 1: This is a " standard" HA (Active-Active) configuration and will have two cluster interconnect
cables connected to the partner node.
(iii) INVRAM is slot 2: This is a SINGLE Appliance configuration or a Fabric MetroCluster configuration. (If a
MetroCluster, a separate cluster card called a " VI-MetroCluster" would be installed in slot 1 for the cluster
interconnect. The cluster interconnect on the NVRAM6 in slot 2 would not be used.)
Check the NVRAM red LED as seen through the faceplate. If it is not
flashing, skip to Section VI. Refer to Fig to right >>
If the NVRAM card is in PCI slot 1 and the LED is flashing between
the cables, confirm with end-user/NGS the partner took over
successfully. If so, the LED can be safely ignored (Partner node
LCD will toggle "takeover)" and the partner's console prompt after
login, will display the word " (takeover)" .
If a successful takeover did not occur, engage NGS to
determine if it is OK to proceed with the replacement.
If the NVRAM is in PCI slot 2 and the LED is flashing, this node did
not flush the data in the NVRAM. Re-connect the power supplies and
turn "ON" both power supplies.
If the node boots up to the " login" prompt, engage end-user to login and issue a " halt" command to flush the data
in the NVRAM. (Hit <enter> to get the login prompt) If the appliance fails to boot up successfully, engage NGS for
guidance.
SA600 and V-FAS6000 Series: Remove the Cables, Cable Management Tray and extract the System Tray
Action Description
If cable management tray is installed, remove it by gently pushing in the sides of the tray at the arrows and lifting the tray up. Ref
Fig 7a-b.
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
NVRAM (shown in slot
1), arrow shows the
location of LED which
is behind the faceplate.
Cable
Management
Tray
Pinch both sides
" in" to remove.
Fig 7a
Fig 7b
Fig 6
VI.
Step
4
VII.
Step
1 Remove media converters if any, from the NVRAM adapter.
2
3 Pull the NVRAM6 Adapter out of the slot as shown in fig 10 below.
4 Remove the replacement NVRAM adapter from its anti-static bag and examine the edge contact pads for damage.
5 Align the NVRAM adapter with the appropriate expansion slot and firmly push it into the slot.
6 Install the primary and secondary PCI adapter retaining brackets. Ref Fig 10 below.
7 Re-attach the media converters if removed, to the NVRAM adapter.
8 Go to Section VIII, "Reinsert the System Tray and reconnect the cables" on next page.
Page 6 of 15
SA600 and V-FAS6000 Series: Remove the Cables, Cable Management Tray and extract the System Tray (cont.)
Action Description
Loosen the six (blue) thumbscrews that secure the motherboard tray to the chassis as noted below. Open the Motherboard tray by
pulling the cam handle down and pulling on the handle to slide the tray out of the system until the NVRAM Adapter is accessible.
SA600 and V-FAS6000 Series: Replace the NVRAM Adapter
Action Description
Loosen the blue thumbscrew on the primary and secondary PCI retaining brackets and lift the retaining brackets up and off the
chassis frame. Ref Fig 10 below.
STOP !!
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
Blue Thumbscrews need to be
loosened to open up the system tray.
Lower Cam Handle and pull
to extract the tray
6
Fig 9
Fig8
Secondary bracket
PCI card
Fig 10
Loosen both blue thumbscrews to remove brackets
NOTE:
In a STANDARD HA (Active-Active) configuration,
the NVRAM adapter is installed in PCI slot 1.
If this is a SINGLE Appliance or MetroCluster the
NVRAM is installed in PCI slot 2.
Primary bracket
VIII.
Step
1 Reinsert the motherboard tray and raise the cam lever and tighten the 6 thumbscrews. (Reference pictures in Section VI)
2 Re-attach the Cable Management Tray if removed. (Reference pictures in Section VI)
3
IX.
Step
1
2 Reconnect the power cords and turn the power supplies on.
3
4
a. Immediately Press ^C (CTRL-C) to access the "Boot menu".
b. If a 'System ID mismatch' warning message below is displayed, answer : " y" .
c. Next, drop to the "LOADER>" prompt from the Boot Menu by following the linked process > here
d. Continue with Section IX on next page.
Page 7 of 15
SA600 and V-FAS6000 Series: Boot Diagnostics and test the NVRAM Memory
Action Description
Re-attach laptop to the console port and capture the display output even if using the end user's computer.
IMMEDIATELY after the console message " Starting AUTOBOOT press Ctrl-C to abort" is displayed, press Ctrl-C
(^C) key a couple times to abort the autoboot. See Console output example below.
IF you miss the window to abort the autoboot, look for this message: " Press CTRL-C for boot menu" and complete steps
4a-4d, otherwise if at the " LOADER>" prompt, skip to step 5 on next page.
SA600 and V-FAS6000 Series: Reinsert the System Tray and reconnect the cables
Action Description
Cables: Fully insert each cable that was removed to its proper port until it clicks in. Test by pulling on them. Especially the
FC and SAS ports!
Phoeni x Tr ust edCor e( t m) Ser ver
Copyr i ght 1985- 2006 Phoeni x Technol ogi es Lt d.
. . . . . . .
. . . . . . .
Por t i ons Copyr i ght ( C) 2002- 2008 Net App
CPU Type: I nt el ( R) Xeon( R) CPU L5410 @2. 33GHz
Starting AUTOBOOT press Ctrl-C to abort...
Loadi ng x86_64/ f r eebsd/ i mage1/ ker nel : . . . . 0x100000/ 3386728 0x53b000/ 3222096
0x84da50/ 1190096
Aut oboot of PRI MARY i mage abor t ed by user .
LOADER->
STEP 3: Press " CTRL-C"
" ." = Deleted lines to save space
. . . . . . .
. . . . . . .
*******************************
* *
* Pr ess Ct r l - C f or Boot Menu. *
* *
*******************************
^C
Boot Menu wi l l be avai l abl e.
Rest or i ng / var f r om/ cf car d/ x86/ f r eebsd/ var f s. t gz
WARNI NG: Syst emi d mi smat ch. Thi s usual l y occur s when r epl aci ng CF or NVRAM car ds!
Over r i de syst emi d? {y| n} [ n] y
STEP 4b: Enter: " y"
STEP 4a:
Press " CTRL-C"
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
IX.
Step
5 Test the NVRAM with the diagnostics by entering " boot_diags" at the " LOADER>" prompt.
6 In the main Diagnostic Menu enter " nvram" to select the NVRAM diagnostic.
7 If asked " OK to run NVRAM diagnostic (yes/no)?" Answer: " yes"
8 Continue with Section IX on the next page
SA600 and V-FAS6000 Series: Boot Diagnostics and test the NVRAM Memory (cont.)
Action Description
Page 8 of 15
LOADER> boot_diags
Loadi ng x86_64/ di ag/ di ag. kr n: . . . 0x200000/ 12606928 0xe05dd0/ 4664936 0x1278c38/ 8 Ent r y at
0x00202018
St ar t i ng pr ogr amat 0x00202018
Copyr i ght ( c) 1992- 2009 Net App.
i ni t mca f or BSP
Di agnost i c Moni t or
ver si on: 5. 4. 7
bui l t : Fr i Aug 27 16: 06: 30 PDT 2010
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
al l Run al l syst emdi agnost i cs
mb FAS6040 mot her boar d di agnost i c
mem Mai n memor y di agnost i c
nvr am NVRAM di agnost i c
agent agent & r l mdi agnost i c
cf - car d Compact Fl ash cont r ol l er di agnost i c
sas SAS cont r ol l er di agnost i c
st r ess Syst emwi de st r ess di agnost i c
Commands:
Conf i g ( pr i nt a l i st of conf i gur ed PCI devi ces)
Def aul t ( r est or e al l opt i ons t o def aul t set t i ngs)
Exi t ( exi t di agnost i cs)
Hel p ( pr i nt t hi s commands l i st )
Opt i ons ( pr i nt cur r ent opt i on set t i ngs)
Ver si on ( pr i nt t he di agnost i c ver si on)
Run <di ag . . . di ag> ( r un sel ect ed di agnost i cs)
Opt i ons:
Count <number > ( l oop sel ect ed di agnost i c( s) ( number ) of passes)
Loop <yes| no> ( l oop sel ect ed di agnost i c( s) )
St at us <yes| no> ( pr i nt st at us messages)
St op <yes| no> ( st op- on- er r or / keep r unni ng)
Xt nd <yes| no> ( ext ended t est s / r egul ar t est s)
Mchk <aut o| of f | on| hal t > ( machi ne check cont r ol )
Cpu <0| 1> ( def aul t cpu)
Seed <number > ( r andomseed ( 0: use machi ne gener at ed number ) )
Ent er Di ag, Command or Opt i on: nvram
WARNI NG! Do not r un t he NVRAM di agnost i c i mmedi at el y af t er a
syst emcr ash or i f t her e i s a possi bi l i t y t hat l og
dat a i s st or ed. Run onl y on new boar ds, or af t er a
nor mal syst emshut down, or i f t her e i s no chance of
pr eser vi ng cust omer dat a.
OK t o r un NVRAM di agnost i c ( yes/ no) ? yes
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
STEP 6: Enter " nvram" to select the
NVRAM diagnostic
STEP 5: Enter " boot_diags"
The model maybe any FAS6000
or V6000 series or a SA600
STEP 7: Enter " yes"
IX.
Step
9 In the NVRAM Diagnostic menu, enter " 1" to select the Comprehensive NVRAM test.
10
move the battery, click >> here
11 Exit the NVRAM test menu by entering " 99" at the menu prompt.
12 Continue with Section IX on the next page
STOP
If the "NVRAM env" test FAILS, the battery is likely too discharged to operate properly without a period of recharging.
Engage NGS and ask if they want the battery moved from the original card to the replacement. For instructions to
Page 9 of 15
SA600 and V-FAS6000 Series: Boot Diagnostics and test the NVRAM Memory (cont.)
Action Description
Confirm these four comprehensive tests show PASSED:1) " *** Comprehensive NVRAM Memory test" ,
2) " *** Comprehensive NVRAM IB test" , 3) " *** Comprehensive NVRAM env test" , and 4) " *** Comprehensive NVRAM
test" . If not all show as 'PASSED' call NGS and report the failure.
NVRAM Di agnost i c
- - - - - - - - - - - - - - - -
NVRAM car ds pr esent :
Sl ot 1: NVRAM6 512 MB ( 0x0000003100000000 t o 0x000000311e000000)
Fi r mwar e 11, Ser i al 634871, Rev G1, Par t 111- 00138
Bat t er y on, Char ger of f , I B Li nk( s) copper / copper
1: Compr ehensi ve NVRAM t est 73: Di spl ay NVRAM st at us
2: NVRAM memor y menu 74: Di spl ay NVRAM conf i g space
3: NVRAM I B menu 76: Upgr ade NVRAM f i r mwar e [ Xt nd]
5: NVRAM envi r onment al menu 77: Cl ear NVRAM pr oper t i es [ MFG onl y]
6: NVRAM EEPROM t est
7: NVRAM FLASH t est 90: NVRAM car d sel ect i on
8: NVRAM i 2c t est 91: Enabl e/ di sabl e l oopi ng
92: St op/ cont i nue on er r or
70: Set NVRAM pr oper t i es [ MFG onl y] 93: Ext ended/ nor mal t est mode
71: Di spl ay NVRAM pr oper t i es 99: Exi t
72: Di spl ay NVRAM EEPROM
Sel ect t est or f eat ur e by number [ 0] : 1
Test i ng NVRAM car d i n sl ot 1
. . . . .
. . . . .
****** Comprehensive NVRAM memory test .......... PASSED
I nt er nal l oopback RDMAWt est . . . . . . . . . . . . . . . . PASSED
I nt er nal l oopback RDMAR t est . . . . . . . . . . . . . . . . PASSED
I nt er nal l oopback SEND t est . . . . . . . . . . . . . . . . . PASSED
****** Comprehensive NVRAM IB test .............. PASSED
. . . . .
. . . . .
NVRAM env subsyst emt est . . . . . . . . . . . . . . . . . . . . PASSED
NVRAM bat t er y t est . . . . . . . . . . . . . . . . . . . . . . . . . . PASSED
NVRAM char ger t est . . . . . . . . . . . . . . . . . . . . . . . . . . PASSED
****** Comprehensive NVRAM env test ............. PASSED
****** Comprehensive NVRAM test ................. PASSED
1: Compr ehensi ve NVRAM t est 73: Di spl ay NVRAM st at us
2: NVRAM memor y menu 74: Di spl ay NVRAM conf i g space
3: NVRAM I B menu 76: Upgr ade NVRAM f i r mwar e [ Xt nd]
5: NVRAM envi r onment al menu 77: Cl ear NVRAM pr oper t i es [ MFG onl y]
6: NVRAM EEPROM t est
7: NVRAM FLASH t est 90: NVRAM car d sel ect i on
8: NVRAM i 2c t est 91: Enabl e/ di sabl e l oopi ng
92: St op/ cont i nue on er r or
70: Set NVRAM pr oper t i es [ MFG onl y] 93: Ext ended/ nor mal t est mode
71: Di spl ay NVRAM pr oper t i es 99: Exi t
72: Di spl ay NVRAM EEPROM
Sel ect t est or f eat ur e by number [ 1] : 99
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
STEP 10: Confirm these
four comprehensive tests
ALL PASSED.
STEP 11: Enter " 11" to
exit the NVRAM test menu
STEP 9: Enter " 1" for
Comprehensive NVRAM Test
IX.
Step
13
X.
Step
1
2 a) From the LOADER> prompt enter " autoboot" to initiate a prom bootstrap.
b)
c) If a 'System ID mismatch' warning message is displayed due to the new Controller Module , answer : " y" .
d) Enter '5' for "Maintenance mode boot".
e) If asked " Continue with boot?" Answer: "y" to exit to the maintenance mode >*> prompt.
NOTE
Under NO CIRCUMSTANCES bypass the system halt on a NVRAM battery voltage issue.
3 Continue with Section X on next page.
Page 10 of 15
SA600 and V-FAS6000 Series: Capture new System-ID on replacement NVRAM
Action Description
The console prompt should be the LOADER> prompt if Diags were exited properly.
When this message appears: " Press CTRL-C for boot menu" , press CTRL-C (^C) to load the " Special boot options
menu" . After about 30-40 seconds, the " Maintenance menu" will appear.
If the System fails to boot to the Maintenance menu, confirm the NVRAM6 Adapter is properly seated. Engage NGS for
assistance.
STOP
If the system reports the battery voltage is too low or a critical failure, do NOT proceed - Do NOT bypass the system stop. Engage
NGS for assistance.
SA600 and V-FAS6000 Series: Boot Diagnostics and test the NVRAM Memory (cont.)
Action Description
Then enter " exit" to exit the diagnostics.
. . . . . . .
. . . . . . .
*******************************
* *
* Pr ess Ct r l - C f or Boot Menu. *
* *
*******************************
^C
Boot Menu wi l l be avai l abl e.
Rest or i ng / var f r om/ cf car d/ x86/ f r eebsd/ var f s. t gz
WARNI NG: Syst emi d mi smat ch. Thi s usual l y occur s when r epl aci ng CF or NVRAM car ds!
Over r i de syst emi d? {y| n} [ n] y
Pl ease choose one of t he f ol l owi ng:
( 1) Nor mal Boot .
( 2) Boot wi t hout / et c/ r c.
( 3) Change passwor d.
( 4) Cl ean conf i gur at i on and i ni t i al i ze al l di sks.
( 5) Mai nt enance mode boot .
( 6) Updat e f l ash f r ombackup conf i g.
( 7) I nst al l new sof t war e f i r st .
( 8) Reboot node.
Sel ect i on ( 1- 8) ? 5
.....
.....
.....
Cont i nue wi t h boot ? yes
STEP 2c): Enter: " y"
STEP 2b):
Press " CTRL-C"
STEP 2d): Enter " 5"
STEP 2e): If this node has a partner node this
message will be displayed. Answer: "y" .
NVRAM Adapter Replacement for the SA600 and V-FAS6000 Series
For NetApp Authorized Service Engineers
Ent er Di ag, Command or Opt i on: exit