Você está na página 1de 69

PRASAR BHARATI

(Broadcasting Corporation of India)


~~G~l~ ~Qlr':'-'~~ll~<-f
Directorate General Doordarshan
<a.'<.",~'i--1~, Chi '-f'<.r~ct-*"l ~,
Doordarshan Bhawan, Copernicus Marg
~ IG~I- ~~ooo~
NewDelhi - 110001
Specification No: DG:DD/TxD/HPT/EV-2012
Dated 17.12.2012
SPECIFICATIONS FOR SUPPLY, TESTING AND COMMISSIONING OF
THREE NOS. OF 10KW (1+1) DVB-T2 UPGRADABLE UHF ANALOG TV
TRANSMITTERS ALONGWITH STATION ITEMS TO BE INSTALLED IN
JAMMU REGION, SRINAGAR REGION &LEH REGION
SPECIFICATIONS FOR SUPPLY, TESTING ANDCOMMISSIONING OF THREE
NOS. OF 10KW(1+1)DVB-T2UPGRADABLE UHF ANALOG TV TRANSMITTERS
ALONGWITH STATION ITEMS TOBEINSTALLED INJAMMU REGION,
SRINAGAR REGION &LEH REGION
TABLE OF CONTENTS
1. INTRODUCTION 4
2. THE SCOPE OF THE TENDER 4
3. ESSENTIAL ELIGIBILITY CRITERIA FOR BIDDER 5
4. GENERAL REQUIREMENTS FOR COMPLETING THE OFFER 6
5. DELIVERY 10
6. GUARANTEE 10
7. MAINTENANCE SUPPORT/SPARES 11
8. LOCAL REPRESENTATIVEIDEALER 12
9. TRAINING AT OEM'S WORKS 12
10. TRAINING AT SITE 13
11. INSPECTION 13
12. TESTING ANDCOMMISSIONING AT SITE 14
13. BOM (UNPRICED) 14
14. LOCAL / REMOTE MONITORING ANDCONTROL FACILITY 15
15. SOFTWARE 16
16. INPUT, MONITORING ANDMEASURING EQUIPMENT RACK 17
17. TRANSMITTER SYSTEM ' 17
18. EXCITER 18
19. POWER AMPLIFIER SySTEM 18
20. LIQUID COOLING SySTEM 19
21. UPGRADEABILITY TODVB-T2TRANSMITTER. 20
22. TECHNICAL SPECIFICATIONS FOR ONE 10KWANALOG TV
TRANSMITTER SYSTEM 24
23. COMPLIANCE STATEMENT 27
ANNEXURE-I 29
B~LLOF MATERIAL FOR (1+1), 10KWUHF BANDIV/V ANALOG TV
TRANSMITTER SYSTEM &STATION ITEMS FOR THREE LOCATIONS INJ &
K 29
DG:DD/TxD/10kW /2012/EV /
Page 1of 68
ANNEXURE II-1 35
SPECIFICATIONS OF 10KWBROADCAST POWER MONITOR 35
ANNEXURE 11-2 36
A. SPECIFICATIONS OF INDOOR COAXIAL FEEDER CU COMPONENTS 36
B. SPECIFICATIONS FOR 15KW MOTORISED R.F. COAXIAL SWITCH 36
ANNEXURE 11-3 37
A. SPECIFICATIONS OF STANDARD19" RACK 37
B. SPECIFICATIONS OF VIDEO EQUALIZING DISTRIBUTION AMPLIFIER ..38
C. SPECIFICATIONS OF AUDIO VIDEO SWITCHER 38
D. SPECIFICATIONS OF AUDIOJACK PANEL-(N/C) 2X24 40
E. SPECIFICATION OF VIDEO JACK PANELS 40
F. AUDIOPATCH CORDS (2FT) 40
G. VIDEO PATCH CORDS (2FT) 40
H. SPECIFICATIONS OF AUDIO STEREO MONITORING AMPLIFIER 8W 40
I. SPECIFICATIONS OF AUDIODISTRIBUTION AMPLIFIER. 42
J. SPECIFICATIONS FOR AUDIOPROCESSOR 42
K. SPECIFICATION OF AMPLISPEAKER 44
L. BROADSPECIFICATION OF LOUDSPEAKER 45
M. SPECIFICATIONS OF VUMETER 45
ANNEXURE 11-4 47
SPECIFICATIONS OF WAVEFORM MONITOR 47
ANNEXURE 11-5 50
SPECIFICA TIONS OF COMPUTER WITH 800VA UPS ANDLASERJET PRINTER
................................................................................................................................................. 50
ANNEXURE 11-6 52
SPECIFICATIONS OF 10KWDUMMY LOAD 52
ANNEXURE 11-7 53
A. SPECIFICATIONS OF COLOUR TEST PATTERN &TONE GENERATOR 53
B. SPECIFICATIONS OF RF ANALYSER 53
C. SPECIFICA TIONS OF AUDIOANALYSER 57
ANNEXURE 11-8 59
A. SPECIFICATIONS OF RF STEP ATTENUATOR (0-100 DB) 59
DG:DD/TxD/10kW/2012/EV/ VW Page20lGB
B. SPECIFICATIONS OF RF FIXED ATTENUATOR 3DB, 6DB, 12DB (NTYPE) 59
ANNEXURE II -9 60
C BAND/KU BAND SATELLITE RECEIVE EQUIPMENT 60
A. SPECIFICATIONS OF PROFESSIONAL IRD FOR C-BAND/KU-BAND: 60
B. SPECIFICATIONS OF CABLES, CONNECTERS 63
C. SPECIFICATIONS FOR THE LNBC IN C BAND 64
D. SPECIFICATIONS FOR KU BAND FEED, CABLE, DISH, AND LNBC 64
ANNEXURE 11-10 67
SPECIFICATION FOR RF POWER METER WITH SENSORS 67
ANNEXURE III 68
INDICATIVE SKETCH FOR 10KW (1+1) TRANSMITTER SYSTEM AT ONE
LOCATI 0N 68
DG:DD/TxD/10kW /2012/EV /
Page 3 of 68
SPECIFICATIONS FOR SUPPLY, TESTING ANDCOMMISSIONING (STC)
OF THREE NOS. OF 10KW(1+1)DVB-T2UPGRADABLE UHF ANALOG TV
TRANSMITTERS ALONGWITH STATION ITEMS TOBE INSTALLED IN
JAMMU REGION, SRINAGAR REGION &LEH REGION.
1. Introduction
a)Doordarshan (DD) intends to installlOkW (1+1) Analog UHF TV Transmitters
whichareDVB-T2upgradable, at threelocations inJ &K. Thelocations arein
JammuRegion, Srinagar Region andLehRegion.
b)These transmitters shall be based on the latest technology and shall have
provisionfor remotemonitoring, remoteoperationandremote Control.
c)The TV transmitters are to be supplied as a complete system including input,
monitoring and measuring equipment, liquid cooling system, UPS, isolation
transformer, AVR, interconnecting cablesetc.
d)'Transmitter System' includes Transmitter alongwith its associated equipment
suchas liquid cooling system, dummy load, RF rigid lines, RF coaxial switch,
Input, monitoring andmeasuring Equipment, UPS, isolationtransformer, AVR,
interconnecting cables etc.
e)A list of items/equipment which is treated essential for completeness of the
system is provided with these specifications in Annexure-I. Any other
item/equipment, which is essential for the completeness of the system, should
also be included inthe offer. It isthe responsibility of the bidder to ensure
that thesystemiscompleteinall respects.
) Channel frequencies for thethree transmitters are givenbelow:
Table 1
S. Station
Frequency band
Operating Channel
No
Freauencv
l. GreenRidge
UHFbandIVN
Ch#22 (478MHz to
( Srinagar Region)
(470MHz to862
486MHz)
MHz)
2. NathaTop
UHF bandIVN
Ch#31 (550MHz to
(Jammu Region)
(470MHz to862
558MHz)
MHz)
3. Himbotingla
UHFbandIVN
Ch#25(502MHz to
( LehRegion)
(470MHz to862
510MHz)
MHz)
2. Thescopeof thetender
The scope of the present tender is to supply the required set of equipment,
acceptance testing &commissioning at sites, training etc. as specified in these
specifications. Theinstallation of all theequipment of theTransmitter Systemat
DG'DD!hD!10kW!2012!EV!~;f ~ Page4of68
sitewill bedonebyDoordarshan. Themainequipment includes thefollowing for
whichBill of Material (BOM) isgiveninAnnexure I:
a. 10kW (1+1) Analog UHF TV Transmitters which are DVB-T2
upgradable.
b. Input and monitoring equipment with pre-wired racks.
3. Essential eligibility criteria for bidder
a) The bidder should be the original equipment manufacturer (OEM) of TV
Transmitter or t4eir authorized representative/dealer.
b) TheOEM of thetransmitter must have anexperience of manufacturing and
supplying UHF Analog TV transmitters of not less than lOkW power output
for at least last 10years as on 31.12.2012. Documentary evidence to support
this must beprovided. TheOEM must provide thedetail of past supply record
inthe format given below inPara 3(c) for last ten years for at least 40no. of
suchTransmitters, alongwith copies of orders for supply of at least 10nos. of
suchTV transmitters.
c) The Transmitter OEM should have at least three years' experience of
upgrading the Analog Transmitter, on 31.12.2012, for DVB-T2 operation by
suitably addingDVB-T2 modulator, softwareetc, to deliver at least 5kWDVB-
T2Power. Documentary evidencemust besubmitted withtheoffer
OR
The OEMs must have at least three years' experience of manufacturing and
supplying of DVB-T2 transmitters, on 31.12.2012, of at least 5kW DVB-T2
power, to broadcasters or broadcast network operators. Details of past supply
record of suchDVB-T2transmitters to various organizations must beprovided
intheformat giveninbelowtosupport this:
Order Transmitter Quantity Nameof the Details* of performance
No. with Type, Model broadcaster with certificates of thecontract.
date, andPower full postal
reference of addresstowhom
transmitter transmitter was
supplied.
(1) (2) (3) (4) (5)
*Copies of actual performance certificates aretobeenclosed bythebidder.
d) In case the bidder is the authorized representative/dealer of the transmitter
OEM, itmust beinthebusiness of salesandsupply of T.V. or radiotransmitter
systems of power not less than 10k W for at least last two years as on
31.12.2012. Documentary evidencetosupport this must beprovided.
e) Thebidder must havehis local office/authorized representative/dealer in
DG:DD/TxD/10kW /2012/EV / Page 5 of 68
Page 6 of 68
India for after sales service and support. The local office/authorized
representative/dealer will be the nodal point for resolving issues related to
testing and commissioning at site and after sales service and support. Any
moduleof transmitter or other equipment requiring repairs will behanded over
to local office/authorized representative/dealer that will arrange repairs
locally or export the defective modules to OEM's factory and re-import after
repairs. However, during Guarantee Period, it would beresponsibility of local
office/authorized representative/dealer tocollect themoduleof transmitter or
other equipment requiring repairs from the site themselves. It is the
responsibility of local office/authorized representative/dealer to arrange the
repair/replacement of faulty items. The cost of transportation, repairs etc.
shall bebornebythebidder duringtheGuaranteeperiod.
f)The OEM of the offered TV Transmitter must have his own local office or its
representatives/dealers in India for after sale service and support. After
salesservicesupport for therepairs/maintenance of transmitter systemafter the
completion of guarantee period, shall alsobeprovided bytherespective OEMs
of the transmitter and other allied equipment either directly or through their
representatives/dealers in India. A certificate as per Annexure III, on their
letterhead, in this regard duly signed by the respective OEMs must be
submitted with the offer.
4. General Requirements for completing the offer
a) The bidder will attach all relevant technical documents in English like
'offered bill of materials with quantity, unit, make and model', Technical
pamphlets, manuals, data sheets, drawings, block diagrams, photographs
etc. of all equipment offered with the transmitter systemthat are essential
to evaluate the offer for technical suitability with reference to DD
specifications. A copy of the Installation manual, Operation and
maintenance manual must beenclosed with technical bid for assessing the
Transmitter system. The transmitter shall be installed by Doordarshan as
per theinstructions givenintheinstallation manual. Theinstallation manual
and the operation &maintenance manual must include at least the details
giveninsub-paras (b) and(c) below:
b) The installation manual must describe the following information:
i. A suggestive floor equipment layout plan drawing with
dimensions in meters for installation of the TV transmitter
systeminatransmitter hall withall alliedequipment.
11. Diagram showing the isometric view of TV Transmitter and
allied equipment with dimensions in meters are to be
provided.
111. All installation drawings with dimensions in respect of all
suppliedequipment aretobeprovided.
IV. All mechanical assembly drawings of the TV transmitter
s~m Wit~dimensions aretobeprovided.
DG'DD/T'D/1DkW/2D12/EV/ ~~ ~
,,---'
v. All the views, i.e. front, rear, top and side (open) of the TV
Transmitters withdimensions aretobeprovided.
VI. Detailed descriptions for installation of cooling system
alongwith the diagrams showing the coolant flow to the
transmitter andtheoutlet to heat exchanger systemshouldbe
provided.
V11. Typical installation drawings with dimensions of heat
exchanger aretobeprovided.
Vlll. Thedetails of unpacking aretobeprovided.
IX. A detailed write up in English regarding installation of TV
Transmitter systemalong with its associated equipment items
shouldbeprovided.
x. The procedure of alignment and adjustment of various
assemblies & sub-assemblies of TV Transmitter such as
Exciter, PA, Control Circuit, output stage etc. should be
described in detail with practical example in the installation
manual.
Xl. All Do's and Don'ts which are essential for safe
installation of theTransmitter Systemshould bedescribed
intheinstallation manual.
X11. An inter-wiring diagram for all equipment installed in the
input &monitoring rack must alsobeprovided inthismanual.
c) Operation and Maintenance Manual must describe in it the following
information:
1. General description of transmitter, transmitter block diagram/
Schematic drawings indicating the details of different blocks,
modules and redundancy incorporated in transmitter and its
subsystems.
11. General description andstructural overview of theTransmitter
racks and Pump Racks indicating the position of different
modules, units, power distribution etc. front andrear, top, side
(open) views of thetransmitters rack withdimensions.
111. Colour Photographs of Transmitter showing thefollowing:
1. Front viewof thetransmitter
2. Rear viewof thetransmitter
3. View of PA with cover opened showing full view of
palletslRF Boards andvariousadjusting pots.
4. Enlarged Open view of PA showing at least two RF
transistors andbiasadjustment pots.
5. Front viewandrear viewofPA.
6. Openviewof SMPS.
7. Openviewof Exciter.
8. Screen shots of various display screens showing
monitorable andmeasurable Parameters of transmitter.
DG:DD/TxD/lOkW/2012/EV /
Page 7 of 68
Page 8 of 68
IV. A detailed description withall relevant circuit diagrams of the
transmitter shouldbeprovidedwithdetails oftest points.
v. The details of all electrical circuits in various stages of the
Transmitter usedalongwiththeir write-ups aretobeprovided
inthis manual.
VI. General description of RF signal flow diagram for complete
RF chain fromexciter to filter output with information about
power level and frequency at input & output of each stage.
Losses and gains invarious stages including power dividers,
combiners, etc. must alsobeshown.
Vll. Description of Transmitter interlocks, protections under
abnormal conditions and schematic drawing indicating
interconnections to different transmitter units, external units
andaccessories likedummy load, changeover switches, reject
loads, cooling pumps etc. which are wired in Transmitter
interlocks.
Vlll. Details andSchematic drawings of liquidcooling systemwith
description.
IX. Details andschematic drawings of remotecontrol &operation
by telemetry systemusing Ethernet/ SNMP/web browser and
broadband connection alongwith screen shots of theinterface
displays. The remotely monitorable and controllable
parameters of thetransmitter shouldbeclearly indicated.
x. General description of Transmitter Control System and
schematic drawing for control signal distribution.
Xl. A detailed description with all relevant circuit diagrams for
thecontrol circuit of thetransmitter shouldbeprovided.
Xll. General description of exciter system, block schematic
showing details of all sub units. Exciter Front andrear views
indicating all inputs, outputs andinterfaces.
Xlll. Description of upgrading the transmitter system to DVB-T2
withrequired changes inExciter andfilter.
XIV. Thedescription of frequency stability with the help of circuit
diagram.
xv. General description and architecture of Power Amplifier's
block schematic drawings, Front, open and rear VIews
indicating all inputs, outputs andinterfaces.
XVI. Full detailed description withthehelp of circuit diagrams and
circuit analysis of Exciter system, PA, SMPS of PA.
XVll. Description of measurement of various DC voltages, currents
andRF power of power amplifier.
XVlll. Description of reserve power capacity and output power
regulation mechanismandprotection mechanism against high
VSWR, high RF output, high temperature, of the Power
Amplifiers andTransmitter.
DG'DD/TxD/1DkW/2D12/EV/ ~ ~
XIX. Description of VSWR foldback alongwith range of foldback.
The explanation of foldback with the help of circuit diagram
must alsobeprovided.
xx. Description of Protection of SMPS of Power Amplifier
against over current, over voltage and over temperature with
thehelpof circuit diagram.
XXI. Details of Splitter andCombiner system's schematic drawings
used inthetransmitter.
XXll. The operating manual should have description regarding
various interfaces, connectors, connecting cables and
accessories required for the satisfactory function of the TV
Transmitter.
XX111. A complete list of all parts/transistors/ICs VLSI/ Components
used inthetransmitter must beprovided inthis manual.
XXIV. The names and number (type) of LDMOS/MOS devices
based on latest Technology used inthe power amplifier must
beclearly mentioned.
xxv. Technical data sheet of all high power RF devices/RF
components usedinthetransmitter.
XXVI. All details of putting "ON" thetransmitter, with thesequence
of operation of theTransmitter for switching ON.
XXVll. Procedure for changing the frequency of operation of the
transmitters.
XXV111. Procedure for operating the transmitter on low power upto 6
dB belowratedpower.
XXIX. Thedetailedprocedure andpossibilities of By-passing control
circuit withdiagrams.
xxx. The description of manual operation of control system and
cooling system.
XXXI. General description of electrical power distribution and
schematic drawing of power supply system used for the
transmitter system.
XXXll. All Do's and Don'ts which are essential for safe Operation
& Maintenance of the Transmitter should be described in
the Operation & Maintenance manual.
XXXllI. The various test and measuring equipment required and
essential for the routine maintenance and calibration along
with the procedure for taking such measurement should be
provided inthemanual.
XXXIV. Various test fixtures and accessories required for the
maintenance/ repair of the TV Transmitter should be clearly
described inthismanual.
xxxv. The detailed procedure for trouble shooting of the TV
Transmitter preferably up to component level should be
described inthemanual.
DG:DD/TxD/10kW j2012jEV j
Page 9 of 68
XXXVI. The systematic trouble shooting/fault tree and flow diagram
should be provided for diagnosis of the faults with their
remedial measures inthismanual.
XXXVll. The routine maintenance schedule for the transmitter should
alsobedescribed inthemanual.
XXXVlll. Soft copies of the above manuals must also be submitted
alongwith theoffer.
XXXIX. The Transmitter OEM must ensure that all the details
required in (i) to (xxxvii) mentioned above are included in
the literature provided with the technical bid both in hard
as well as soft copy.
5. Delivery
The complete set of the 'transmitter system' with all allied equipment as per
BOM given inAnnexure I isto be delivered ingood condition at each of the
three sites mentioned inTable 1. It will bethe responsibility of the bidder to
ensuresafedelivery of all theequipment at eachof thesethreesites.
6. Guarantee
a) Therespective manufacturers shall guaranteethesatisfactory working of
all the equipment of the Transmitter System, for twenty four months
fromthedateof completion of acceptancetest at siteor for thirty months
fromthedateof receipt of last acceptedconsignment at sitewhichever is
earlier. Any defect/ failureof any component, module, assembly of any
equipment and its non-performance during this period is to be set right
by the bidder/ manufacturer(s) free of cost and the repaired/replaced
item(s) tobedeliveredat thepremises of theconsignee.
b) A Guarantee certificate, as inPara 6(a), fromthe respective OEMs on
their letter heads, for the third party bought equipment/items offered
withthetransmitter system, must alsobeattached withtheoffer.
c) Any Future upgrade of software or Software updates for all the
equipment (such as Transmitter, all input, monitoring, measuring and
allied equipment etc.) within twenty four months of commissioning of
the Transmitter Systemor for thirty months fromthe date of receipt of
last accepted consignment at sitewhichever isearlier shall be available
free of cost to Doordarshan. Backward compatibility of the software
must alsobeensured for that equipment/item.
d) Any module/Assembly/ Sub Assembly of the transmitter systemor the
power supply system failing during the guarantee period shall be
repaired/replaced freeof chargebythebidder at site. Thetransportation
charges if any shall be borne by the bidder. Guarantee period of that
module/Assembly/ Sub Assembly would be extended corresponding to
DG,DD!TxD!10kW!2012!EV! ~ ~ Page10 of 68
-....
theoutageperiod, if therepair/replacement of thefailed itemtakes more
than 30days.
1. DD will intimate the fault to the OEM or its authorised
representative/dealer or local office/authorized representative/
dealer of the bidder, who will deploy the staff at site within 3
days andattendthefault withinaweek.
11. In case it is not possible to repair the defective unit/module at
site, the above mentioned nodal office will provide the
replacement unit/module toensurethecontinuity of theservice.
111. In casethe unit is to besent to the OEM for repairs, it has to be
repaired andfittedback within30days of intimation of fault.
7. Maintenance support/spares
a) The minimum recommended essential spares (like modules of PA, Power
Supply Modules or any other critical spares suggested by the OEM),
required to maintain the continued service of transmitter in a reliable
manner, shall bequoted separately bythesupplier positively.
b) The minimum, recommended essential spares may be based on predicted
rateof failureandrequirement for threeyears.
c) The manufacturer shall also give a certificate attached with the offer to
supply maintenance support and all spares during the lifetime of the TV
Transmitter. The life of the TV transmitter must be certified by the
manufacturer. Thelifeof transmitter shouldbemorethan Tenyears.
d) The bidder must also attach with the offer the certificates to supply all
spares, installed softwares and software updates for providing maintenance
support during the lifetime of all the input, monitoring and all other
auxiliary items/equipment offeredwiththetransmitter system.
e) The lifetime of all other major items such as measuring Equipment, UPS,
AVR etc. must alsobeprovided bytherespective OEMs.
1) The maintenance support of each equipment/items/ allied equipment
supplied is to be ensured by therespective OEMs. Duly signed necessary
certificates inthis regard areto beprovided by the respective OEMs only
ontheir letter heads.
g) In case the bidder quotes the optional items as 'a set', the details of the
components/items offered in the 'set' must be spelt out clearly including
their Model Nos. and quantity, failing which the tender is likely to be
rejected.
h) Thespares shall betreated asoptional items andthecost of spares shall not
betaken intoaccount whiledecidingthelowest bidder.
i) In addition, the bidder shall provide, in the following format, the address
and contact information for after sales service and support of all the
DG:DD/TxD/IOkW /2012/EV /
Page11of 68
equipment including the third party bought out equipment or at least
for IRDs, 4.8 M PDA, Audio-Video Switcher, Audio Analyser, Test Pattern
generator, WPM, VDA, ADA, RF Analyser, Broadcast Power Monitor,
Dummy Load, RF Co-axial switch, UPS, Battery Bank, Isolation
Transformer, AVR that are to be supplied with the transmitter system as
part of input, monitoring, measuring or allied equipment.
Name of OEM After sales & Name, Authorization by
Equipment support office Telephone/ Fax! the OEM for
with model address Email of supply and after
No. concerned sales service and
personnel support of the
equipment
(1) (2) (3) (4) (5)
8. Local Representative/Dealer
a) Documentary evidence about local after sales and support arrangement
as per Para 3(e &f) above for the transmitter system must be provided
with the offer. The address, contact details of local office/representative,
details of technical staff, their qualification and experience etc. must be
provided with the offer.
b) In case any item of transmitter system requires repairs at works/factory,
the same would be handed over to local office /Representative/Dealer of
OEM/bidder in India, who would arrange export of the item to
works/factory and re-import inIndia after repairs.
c) After sales service and maintenance support of the transmitter should be
available in India through the local office/Representative/Dealer even
after the guarantee period is over and throughout the life of the
transmitter as certified by the OEM.
d) Copy of Agreement! MoU signed inthis regard between OEMs and their
local representative/dealer must be submitted with the offer.
9. Training at OEM'sWorks
a) A proposal should be attached with the offer for training on operation &
maintenance, installation and testing of the offered TV transmitter to five
Doordarshan Engineers at Transmitter Manufacturer's works for 5days.
b) The training programme will be structured so as to cover theory of
operation Maintenance, Practical demonstrations of circuits, Maintenance
demonstrations, Fault finding, Circuit Tracing exercises, Part Replacements,
installation and testing of the offered TV Transmitters.
c) Two sets of training lecturers notes, schematic drawing, hand book etc. shall be
supplied to DDG(E) (Transmitter Design), DG: DD also.
d) The offer shall include training fee only (To &Fro air fare, per diem, lodging,
boarding charges etc. for DD Engineers shall be borne be Doordarshan and are
OG,OO/TxO/10kW/2012/EV/ V~ Page12 of 68
'-
not to bequoted.) Thecost of training shall beincluded inthe essential items
ofBOM.
10.Training at Site
a) OEM(s)' representative(s) shall offer one day trammg on operation and
configuration of Transmitter Systemat siteafter siteacceptance test.
b) Two setsof training lecturers notes, schematic drawing, handbook etc. shall be
suppliedtoDDG(E) (Transmitter Design), DG: DDalso.
e) Training fee quoted by the bidder shall include all charges like training fee,
travel, boarding, lodging and local transport charges for deputing the OEM
expert(s). DD shall bear all touring expenses of DD engineers deputed for
training and the same is not to be included by the bidder in their offer. The
training feeif any shall beincluded intheessential items of BOM for deciding
lowest offer.
d) The training shall cover theoretical concepts, demonstration of features,
Software, Configuration of Transmitter units, operational & maintenance
instructions, fault finding, circuit tracing, component/ module replacements,
trouble shooting, preventive maintenance and other relevant topics etc. related
tothe0 &M of thetransmitter.
e) Training material in hard and soft copies is to be provided to each DD
engineer undergoing theabovetraining.
11.Inspection
a) ATP: A copy of ATP (Acceptance Test Procedure) must be submitted by the
bidder with the offer. ATP should describe the standard testing procedures
and the details of test benches for carrying out measurement etc. for the
offered transmitter. The test reports will not be treated as ATP. The OEM
only shall prepare theATP for their product being offered. TheATP shall be
approved by Doordarshan after necessary modifications if required. The
approved ATP shall be sent back only to the successful bidder and is to be
used for inspection of transmitter by two DD Engineers at OEM's works
beforedispatch of theTransmitter.
b) Thebidder has to intimate DD for inspection andtesting of theTransmitter, at
least eight weeks in advance when the equipment are likely to be ready for
inspection. Inspection periodwill bethree days for each transmitter.
c) The bidder shall quote inspection fees only in his offer excluding the
expenditure for DD inspectors on To &fro airfare, per Diem allowances,
lodging, boarding charges etc. which shall be borne by Doordarshan. The
inspection feeif anyshall beincludedintheessential items of BOM.
d) Incase, inspection at OEM's works isnot carried out, the transmitter shall be
accepted on the basis of Factory test report, duly signed and stamped on the
letterhead of the OEM, provided by theOEM of thetransmitter which should
reachthesitealongwith thetransmitter.
e) All other associated equipment, items andaccessories will beaccepted onthe
basis of OEM's Test Certificates (asper DD Specification) duly signed and
DG:DD/TxD/lOkW /2012/EV /
Page 13 of 68
stamped onthe letter head of theOEM, failing which Test Certificates will be
considered incomplete and equipment offered by the firm is liable to be
rejected. All thetest certificates shouldreach thesitealongwith therespective
equipment.
12.Testing and Commissioning at site: SiteAcceptance Test (SAT)
a)Thetransmitter systemshall beinstalledbyDoordarshan asper theinstructions
contained in the manufacturer's installation manual. DD will intimate the
bidder whenthe installation of the transmitter system is completed, giving
them three weeks' time for completing travel formalities etc. The
representative of Transmitter OEM shall visit the site for site acceptance test
andcommissioning. Thetesting andcommissioning shall becompleted within
7days.
b) For this purpose complete SAT Procedure will be prepared by the
OEMlbidder inrespect of transmitter systemandthepower supply systemand
shall be submitted for the approval by DD. The endurance test of each
transmitter shall also be part of SAT. The test procedure shall indicate full
details of test set upand equipment required during theAcceptance Testing at
thesite. All thetest equipment needed for siteacceptance aretobearrangedby
thebidder.
c)TheOEM's representative will examinetransmitter installation for correctness.
Thereafter, the 'First Power ON' at siteof the entire system shall be doneby
the OEM's representative (s). However, if necessary, the OEM may include
appropriatemeasure intheequipment toavoidany 'Power ON' beforeSAT.
d) The expenditure for OEM engineer(s), representative(s) on travel,
lodging, boarding, daily allowances etc. for site acceptance testing shall be
bornebythebidder.
e)The maximum duration of installation of transmitter system at site shall be 9
months fromthedateof receipt of all thematerial ingoodcondition at site.
13.80M (Unpriced)
a) A detailed, complete Bill of material (BOM), exactly inthe same format as in
the price bid, shall be attached with the technical, bid leaving price column
blank.
b) Make, model, quantity andunit of each itemmust bementioned clearly inthe
BOM. Incase of 'set' complete details of all components that formpart
of set should be spelt out clearly i.e. the details of the component/item
offered in the set including their part no. and quantities must be mentioned
clearly.
c) TheBOM isprovided inAnnexure I for 10kWUHF Transmitters with station
itemsfor boththetransmitters.
d) The bidder must quote for all the items of Annexure I. The offer with
incompleteBOM shall berejected.
e) It isthe responsibility of thebidder to ensure the completeness of the offered
system. In case, the bidder fails to offer any item(s) which is found essential
duringinstallation, thesameshall havetobesuppliedfreeof cost.
DG,DD/TxD/lOkW/2Dl2/EV/ V~ Pagel'olG8
f) The bidder must quote all the items listed III 'Essential items' as well as
'Optional items' of the BOM.
14. Local/remote Monitoring and control Facility
a) Each transmitter should have all provisions of local LCD display, keypad, panels
etc. for local operation, monitoring/control.
b)All parameters and working status of modules specified in Para(j) (i to xxi)
given below should be available for local monitoring.
c) Detailed information on the parameters and features available for local
monitoring and Control of the transmitter is to be submitted with the offer.
d)The transmitter shall have Control/operation and monitoring of the parameters
locally as well as at remote-location through web interface.
e)The Control/operation and monitoring Software would run on normal PC with
Windows platform.
f) The transmitter should have a 'WEB' GUI interface using TCP/IP. Necessary
Transmitter functions Control & monitoring shall be provided via the remote
"WEB" GUI interface.
g)Full functional description alongwith diagrams, block schematics, flow charts,
pictures of various screens etc. must beattached with the offer.
h)Both the transmitters should be remotely as well as locally monitorable/operable
individually.
i) Alarms and logging provision should also be available for logging events and
faults for minimum 1000 logs.
j) Remotely and Locally Monitorable parameters: Following parameters of
transmitter are to be made available for monitoring on the PC at the remote
location as well as on local PC. Details about all the individual screens may be
provided with the offer.
1. Forward vision RF power
11. Reflected vision RF power
111. Forward aural RF power
IV. Reflected aural RF power
v. Output Power of each PA
VI. Reflected power of each PA
V11. DC power supply voltages of each PA
Vlll. PA transistor/pallet currents for drivers
IX. PA transistor/pallet currents for intermediate stage
x. PA transistor/pallet currents for final stage.
Xl. PA heat sink temperature
X11. Status of exciter incircuit
Xlll. Exciter output power
XIV. AGC level
xv. Coolant Temperature
XVI. Status of pumps in circuit
DG:DD/TxD/lOkW /2012/EV /
Page 15 of 68
XVll. Status of heat exchanger
XV1l1. Summary fault log
XIX. Fault and interlock indication: exciter fault, High reflectionlVSWR and
indications.
xx. Alarms for PA's VSWR, Temperature, Exciter fault alarm.
XXI. Any other parameter which the Transmitter manufacturer thinks
essential for proper functioning of a remote Controlled/operated
transmitter.
k)Automatic Control unit (ACU):
i. The description of complete switching sequence of transmitters and
associated equipment along with all monitoring and Control features of the
transmitter must beprovided.
11. One automatic changeover unit (ACU) for operating the Transmitters in
(1+1) mode to facilitate automatic switch "ON" of the second Transmitter
unit in case of failure of RF output of the first Transmitter unit, shall be
supplied with each set.
111. When power of operating transmitter goes down by 3 dB, it should be
sensed as a 'failure' to switch to second transmitter automatically and it
should be connected to antenna load. The failed transmitter shall be
connected to dummy load.
IV. There should be provision for display for monitoring of (1+1) Transmitter
inACU.
v. There should be provision for switching ON &OFF and change-over of
transmitters remotely through ACU.
VI. Provision is to be made in the ACU to enable operating personnel to
operate the transmitter locally.
Vll. Arrangement shall be made for bypassing the ACU in case of its failure so
as to enable operating personnel to operate the individual transmitter in
manual mode also.
V1l1. The ACU shall be provided and integrated by the OEM of the Transmitter
only.
1) Compatible P.c.s for local and remote monitoring, laser printers of reputed make
and UPS are also part of the tender. Specifications are given inAnnexure II-5
15. Software
a) One set of Copies of all softwares used in the transmitter system should
beprovided inthe form of CD besides being loaded into the system.
DG,DD!TxD/1DkW/2D12/EV/ ~7 ~ Page16 of 68
b) All software licenses are to be provided to Doordarshan on perpetual
licensebasis without specifYinganytimelimit or without specifYingany
'end of life' of anyof thesoftwares supplied.
16.Input, Monitoring and Measuring Equipment Rack
Theequipment likeIRD, lOx2Audio-Video switcher, Waveform monitor,
Colour Pattern Generator, andmonitoring amplifier etc. should beinstalled
in standard 19" wired rack(s). The TV Receivers need not be installed in
Racks but beprovided withsuitablestands.
17.Transmitter System
TheGeneral features of transmitter systemareasbelow:
a)Thetransmitters should berugged, reliable, andstableinoperation under Indian
tropical conditions. The climate may vary fromvery cold to hot, humid and
dusty. Specifications of the transmitters are given in this document. All
equipment would beusedfor 24x7continuous operations.
b)Transmitter output should be 3W' EIA unflange copper. In case of Aluminium,
suitabletransfer coupler/rings to connect the output with the Copper rigid line
shouldbesupplied toavoidthermocouple effect.
c)Theoutput of either of thetwo 10kWtransmitters will befedthrough single4"
Dia. R.F. Feeder Cable via R.F. Change Over Switch (C/O SW) to the single
10kW UHF, Superturnstile Antenna system and the other transmitter to the
dummy load.
d)There should be provision of interlock between Transmitter and Antenna
load/Dummy Load so that transmitter is switched ON only when either of the
two loads isconnected.
e)Thetransmitter shall have its own VSWR fold back, automatically turning off
the PAs if the VSWR is still beyond a preset threshold after the three strike
mode. TheVSWR foldback rangemust bespecified bytheOEM innumerical
values or graphically.
f) The offered transmitters should have low. level diplexing (Common
Amplification).
g)There shouldbeprovision for settingthelower andupper limits for theForward
andReflected Power.
h)A detailed block schematic diagram for the TV transmitter system with all its
constituent items shouldbeprovidedwiththeoffer.
i) Thepower consumption of theUHF Transmitters including the cooling system
must bespecified bythebidder for bothAnalog andDigital (DVB-T2) modeof
theTransmitter separately.
j) Thequotedtransmitter systemmust conformtothelatest international standards
of safety and EMC or their equivalent standards. The conformation to such
standards/equivalent standards (indicating Standard's name & Number) must
be stated in compliance statement. Documentary evidence to establish the
equivalence of the standards must also be provided with the offer. Para22
(SubParas 1.10, 1.11)may alsobereferred.
DG:DD/TxD/lOkW /2012/EV / Page 17 of 68
k)Environmental Regulation: In compliance of keeping green Environment, the
Transmitter built with hazardous materials &useof Toxic substances will not
be accepted. WEEE/ROHS (Waste Electrical & Electronic
Equipment/Reduction of Hazardous substances) regulations shall be strictly
adheredto.
18. Exciter
a) EachUHF Transmitter shall haveitsownsynthesized exciter capableof
operation in any channel (with offset facility) in the frequency band
"470to 862MHz" for UHF band.
b) The channel conversion within the band should be possible at site
without any changeof component except output Channel filter.
c) The exciter shall be modular in design, 100% solid-state and self-
contained stand-alone unit.
d) Exciter shall haveitsownDC power supply.
e) It shall have facility for correction of linear and non-linear distortions
added intheRF PathusingDigital Signal Processing (DSP).
f) A detailed circuit diagrammust beattached withtheoffer toconfirmthe
availability of DSP intheexciter.
g) Thedetailedpart list of theexciter must alsobeprovided.
h) Themethodology of correction of linear andnon-linear distortions shall
alsobeexplained inthetechnical manual of theexciter.
i) Thereshouldbeprovision for indicationof alarms andwarnings.
j) The exciter must have provision for AGC for optimizing the output
power in different operating conditions and in both analog as well as
Digital mode.
k) Onreduction inoutput power of thetransmitter theoperation of exciter
system should automatically change to MGC (manual gain control)
mode to avoid overdriving of the PAs or the control system should
adjust automatically toavoidoverdriving of PAs.
1) TheExciter shall beequipped with 101100baseT Ethernet interfaceand
shall haveremotecontrol provisionbySNMP or Web interface.
19.Power Amplifier System
a) ThePower Amplifiers shouldbemodular indesign, lowweight, power-
efficient andeasily maintainable.
b) Each PA should have independent built-in SMPS (Switched Mode
Power Supply) based power supply unit. The SMPS should have
adequate margins for satisfactory working under overloading. It should
be able to handle the fluctuations in power supply voltage and
frequency.
c) SMPS of the PA module shall also be protected against overload
conditions, i.e., over temperature, over voltageandover current.
DG'DD/hD/1DkW/2D12/EV! ~~ ~ Page18 of.8
d) TheSMPS may bedesigned soastotakeAC input from3phase4wire
systemdirectly (400 V).
e) All PAs shall be fully broadband for operation in the frequency range
470MHz to 862MHz for UHF Transmitter.
t) All PAs must be inter changeable to beused at any position and to be
used for any channel inthe specified band of operation without change
of anyhardware/software inthetransmitters of samemakeandmodel.
g) All PAs shall have protection against high SWR, over current, over
voltage and over temperature. Visual indication for above protections
shouldbeavailable ineachpower amplifier.
h) LDMOSIMOS devices of reputed manufacturers and based on latest
technology shall beusedinall power amplifiers.
i) Due to aging the bias current of the offered LDMOSIMOS transistors
may drift away from the nominal level. Biasing circuit/ above
LDMOSIMOS should take care of this drift. The Characteristic
Datasheet of the LDMOSIMOS transistors based on latest
technology from the manufacturer must be attached with the offer.
j) LDMOSIMOS devices offered and used inthe final RF stage must not
belessthan 'SOV' type.
k) All PAs shouldbehot pluggable. Transmitter shall becapable toremain
ON AIR withreduced power output without anybreak inserviceevenif
a PAlP As have failed. Power reduction on failure of one PA and
subsequently morethanonePAs istobespecified bytheOEM.
I) TheRF pallets/RF Boards should befieldreplaceable without requiring
major adjustments or alignment.
m) Even intheevent of failureof sometransistors of final stageof thePA,
thePA module shall continuetooperateat reduced power.
n) Each amplifier's path shall have its own variable gain RF corrector
allowing individual adjustment of gain and phase or shall have
provision of automatic gain and phase adjustment.
0) The amplifiers path shall incorporate an automatic control circuit for
automatic compensation for normal temperature verses gain variation of
theamplifiers.
p) Each power amplifiers shall haveitsown circuit breaker to connect and
disconnect it withtheAC power line.
q) Thecooling systemof power amplifiers shall bedesigned such that the
tubes and hoses connected with the pressure valves can be isolated,
drained and removed without any wastage of coolant. A manual valve
shouldalsobeavailablebesides automatic pressure valves.
r) There shall beprovision for monitoring of Reflected power and Output
power toassess thehealthandnormal working of thePA Unit.
20.Liquid Cooling system
a. The transmitter must have closed circuit liquid cooling system. Air
cooled transmitter system is not acceptable. Thecooling systemmust
beprovided bytheOEM of thetransmitter only.
DG:DD/TxD/IOkW /2012/EV /
Page 19 of 68
Page20 of 68
b. The cooling system and heat exchangers must have adequate
redundancy of pumps and fans with automatic changeover to make it
fullyreliable. Manual changeover shouldalsobepossible.
c. Thedetail of type of coolant used must beprovided by the OEM of the
transmitter.
d. Full required quantity of thesparecoolant isalsotobesupplied withthe
systeminadditiontothefilledupquantity for thetransmitter.
e. A proper and professional coolant filling arrangement shall also to be
suppliedwiththecoolingsystem.
f. Particle filter, monitoring of temperature at inlet andoutlet, flowsensors
andpressure sensor shouldbeprovided.
g. One set of all the essential tools required for installation and
maintenance of cooling systemmust besuppliedwitheachtransmitter.
h. Tubes and Hoses onamplifiers etc. shall beof self-locking type sothat
noliquidescapes duringchangeover.
i. Location wise variations of outside temperature are given in Table
3. Heat exchanger and liquidcoolant used must becompliant withthese
temperature variations. There should be special provisions for
satisfactory working of Heat exchangers to transfer theheat at very low
temperature of outside environment. It must be ensured by the bidder
that theHeat Exchanger isprotected fromheavy snowandwind.
j. The total heat transferred by the transmitter (for 10 kW Peak Sync
Analog power of thetransmitter at theoutput of Band pass filter) inthe
liquidandinsidetheroommust bespecifiedbytheOEM.
k. Thecapacity of theheat exchanger alongwith its detailed specifications
anddetails of dimensions must also bespecified by theOEM as per the
datagivenin(j) above.
I. The dual pump system should be such that it should be possible to
replaceoneof thetwopumps whilethetransmitter isinoperation.
m. Full detailed description of the liquid cooling system is to beprovided
with the offer. A typical diagram, showing details of liquid cooling
systemandheat balancing of transmitter systembringing out all special
requirements, shouldbeattachedwiththeoffer.
n. A typical layout showing the maximum permissible distance between
the transmitter and the cooling system (Pump assembly and heat
exchanger assembly) must also be provided with the offer. The
necessary length of thepipes as per the maximum permissible distance
must besupplied.
21. Upgradeability toDVB- T2Transmitter:
a. Theoffered analog transmitter should beupgradable to DTT (DVB-T2)
Transmitter (Digital terrestrial transmitter adopting DVB-T2 standards
with all features as per ETSI document EN302755, v 1.3.1or latest) in
f U t u r e . ~
DG,DD!TxD/1DkW/2012/EV/ ~) ~
b. Full technical details for upgradation of quoted analog transmitter as
DTT (DVB-T2) transmitter along withthe financial requirement for the
upgradation must be furnished with the offer separately without which
tender will beconsidered incomplete&isliableto be rejected.
c. This Upgradation cost will however not be counted for deciding the
lowest bidder. Break updetail of the necessary items must beprovided
intheBOM asoptional items.
d. The broad specifications of upgraded DVB-T2 transmitter are given
below:
'tt rDVB T2T oa .peCI lca Ions0
-
ransml er:
S,N, Parameter Parameter Value Required bv DD
1 AC Power Supply Requirements
1.1 Power Supply 400V 10%, AC three phase 4-
wire+ground, 50Hz +/- 2Hz
1.2 Power Factor >0.9
1.3 Total power supply consumption Tobespecified bythemanufacturer inkW
of Complete TV transmitter at full
power including cooling system.
2 Environmental Requirements
2.1 Ambient Temperature (For parts Pleaserefer Table3.
of the Transmitter and allied
equipment to be installed inside
thetransmitter hall)
2.2 Ambient Temperature (For parts
of the Transmitter and allied
equipment to be installed outside
thetransmitter hall)
2.3 Ambient Temperature (for storage
of Transmitter and allied
equipment)
2.4 MaxAltitude
2.5 RelativeHumidity
2.6 Requirement of air conditioning Any special requirement of air
conditioning of thetransmitter hall should
bespecified clearly bythemanufacturer.
2.7 Acoustic Noise S65dBA (lM away fromfront and 1.5M
upformthefloor, excluding coolingpump
andheat exchanger)
3 Mechanical Specs
3.1 (a)Dimension of transmitter Tobespecified bythebidder
(LxBxH) (inmillimetre)
(b)Dimension of Pumprack
(LxBxH) (inmillimetre)
(c)Dimension of Heat exchanger
Dr dS 'fi t'
DG:DD/TxD/10kW /2012/EV / Page 21 of 68
Page 22 of 68
(LxBxH) (in millimetre) and
details of mounting arrangement if
any
3.2
(a)Weight of transmitter (in kg)
To be specified by the bidder
(b) Weight of Pump rack (in kg)
(c) Weight of Heat exchanger (in
kg)
4
General Requirement
4.1
Cooling System
Liquid Cooling with Heat Exchanger
(Please refer Para 20 for details)
4.2 Safety
EN 60215/ EN 60950 (with latest
amendments) whichever is applicable.
4.3 EMC
EN 301489-14 with latest amendments
5
System Parameters
5.1
Transmitter Power output (after
AVERAGE (COFDM-DVB- T2)
output critical mask filter)
Corresponding Power must be specified by
the OEM for the offered transmitter which
is 10kW Analog Transmitter.
5.2
Output power reduction of
Power reduction intabular form on failure
transmitter
of one PA and subsequently more than one
PAs isto be specified by the OEM inthe
Technical manual.
5.3
Frequency Range
Any assigned channel between 470 MHz
to 862 MHz (UHF Band IVN)
5.4
Bandwidth
8MHz
5.5 TV standard
DVB-T2, compliant to EN 302755,
version 1.3.1 or the latest.
5.6
Carrier frequency stability
Of the order of 1xlO-
t
per year
5.7
Output connector of Transmitter.
3-118" EIA un-flanged (silver plated
copper)
Note 3-118" un-flanged copper rigid line is
to be connected as indoor coaxial line. In,
case Transmitter is having different output
connector or Aluminum output line,
Proper transfer coupler must be supplied
to ensure that firm connection is made to
copper rigid line without causmg
thermocouple effect.
5.8
RF output impedance
50 ohms with VSWR <1.3
5.9
Harmonic level (for all harmonics)
60 dB below carrier level or better
5.10
Spurious emission
60 dB below carrier level or better
~~
.
DG:DD/TxD/10kW /2012/EV /
5.11 Modulation
Coded orthogonal frequency division
multiplex (COFDM) having all modes of
modulation and parameter options as per
EN 302755, version 1.3.1 or the latest.
5.12 Inter modulation products (before
::S-35dB (with pre correction) at 4.2MHz
filter)
W.r.t. Centre Frequency.
5.13 Crest Factor/P APR
13dB Max
5.14
Insertion loss of DVB- T2 critical
0.4 dB or less inBand IV and Band V.
mask filter at Centre Frequency.
5.15
MER at the input of critical mask
~33 dB
filter with 6kW DVB-T2 power at
the output of critical mask filter.
5.16 Switch on Time
<5second
5.17 Shoulder Level (before filter)
<- 35 dB
5.18 Shoulder Level (after critical
According to offered DVB-T2 critical
filter)
mask filter as per ITU/ETSI Standards.
Necessary graph to support must be
provided.
6
Monitorin~ and control facility (Please refer to Para 14)
6.1 System Monitoring
The monitoring system shall have bright
LCD/TFT graphical display. Control
circuits should
be
microprocessor/microcontro ller
based.
Mimic diagram IS to be provided for
diagnostic and trouble shooting of
transmitter system.
6.2 Remote operation, control &
The transmitter shall have the necessary
monitoring of transmitter
interfaces for connecting it to a personal
parameters.
computer. SNMP interface and web
browser should be available. All
parameters
should be
monitorable/controllable on the personal
computer. A suitable Personal Computer
with pre-loaded software(s) for monitoring
and control facility mentioned in Para 14
must be provided for the same alongwith
the transmitter. In addition, the same
software in CD must also be provided with
each transmitter as backup.
7 Efficiency of Transmitter at full
To be specified by the OEM.
power (in %) including cooling
system
DG:DD/TxD/lOkW /2012/EV /
Page 23 of 68
22. Technical Specifications for one 10 kW Analog TV
Transmitter System
DG:DD/TxD/lOkW /2012/EV /
Page24 of 68
Value
The detail is given inTable 3.
PAL : 625 lines, ITUR - G
To be specified by the suppliers III
meters.
The be specified by the suppliers III
Kgs.
::;4kVA
400 V 10%, 50Hz 2%
three phase 4-wire / 230V single
phase
& ower factor >0.9.
::;45kVA
EN 60215/ EN 60950or equivalent
(withlatest amendments) whichever is
a licable.
EN 301489-14 or equivalent with
latest amendments
10kW
Aural Power: FA,= -13dB,
FA
2
= -20dB and -10dB for Mono,
Parameter
General Parameters
A.C. input Power Supply
(a)AC power consumption of
TV transmitter systemat black
level
(b) AC power consumption of
coolin s stem
Ambient Temperature (at the
specified altitude)
For Parts of transmitters to be
installed insidetheContainer.
(a) For Parts of transmitters
tobeinstalledoutside.
(b) For stora e/trans ort.
RelativeHumidit
Max Altitude
TV Standard
(a)Dimension of transmitter
(Lx Bx H)
(b) Dimension of Pump rack
(L xB xH)
(c) Dimension of Heat
exchan er L xB xH
(a)Weight of transmitter
(b) Weight of Pump rack
c Wei ht of Heat exchan er
Safety
EMC
R.F. Parameters
1.Output power of each
Transmitter
(Visual syncpeak)
At theoutput of bandpassfilter
2.Aural Power
S.No.
1.
1 . 1
1.3
1 . 2
1 . 4
1.5
1.6
1 . 7
1.10
1.8
1.11
2 .
. 1
w.r.t. Visual Carrier Power
~. 2 Frequency Range of
Any assigned channel of 8MHz
Transmitter
between 470MHz to 862 MHz (Band
IV 1 V with facility of frequency
offset by 2/3 of line frequency
.3 Carrier frequency stability
Of the order of lxlO-=Tper year
2 . 4 RF output impedance
50 ohms with VSWR <1.3
.5 Harmonic level
60 dB below carrier level
2.6
Spurious emission
60dB belowcarrier level andnot
exceeding 12mW
2.7
Output Peak Power Stability
Within 2%.
(Black to white transition)
Blanking Level Stability
Within 2.5%.
~.8 Incidental carrIer phase Within 4
modulation
~.9 (IMD) Inter modulation
- 53 dB or better
distortion for common
amplification
2.10 Type of Amplification
Common Amplification
2.11 Modulation
Video: Negative AM (C3F) with
Colour PAL-G, Audio: FM (F3E)
.
Video Parameters
3.1 Video input Level
Sync O.3V 6dB, video 0.7V
. 2 Video input impedance
75 ohms unbalance (BNC)
.3 Video input return loss
>34 dB (Upto 5MHz)
. 4 Video Frequencv response
As per Table 2
13.5 Random AM Noise (100kHz to
5MHz) RMS Value:
Unweighted continuous
-52 dB (RMS) or better
Weighted continuous
-60 dB (RMS) or better
Periodic NoiselHum
-46 dB (p-p) or better
3.6 Waveform response:
2T pulse
within 2.0% K-rating
Line Tilt
within 2.0% (1%K rating)
Field tilt Filed T
within 2% (1%K-rating)
13.7 Non Linear Distortion at
4.43 MHz:
Differential gain
Within 5% (at APL 50%)
Differential phase
Within 5 (at APL 50%)
3.8 Baseline distortion of 20T Less than 3%
pulse
3.9
Group delay without receiver
better than 50 nS
precorrection and sound trap
off (0to 4.8 MHz)
DG:DD/TxD/10kW /2012/EV 1
Page 25 of 68
Audio Parameters
~. 1 Audio Input Level
-4dBm to +1OdBmfor 50kHz
deviation
4 . 2 Audio Input & Impedance
2Nos. & 600 Ohms balanced
~. 3 Audio Input Return Loss
30dB (between 30Hz to 15kHz)
~. 4 Audio Frequency Deviation 50KHz nominal
(For 100% Mod.)
4 . 5 Audio Modulation Capability Upto 75kHz deviation
4 . 6 Audio Carrier displacement at 50Hz (Max)
50 kHz deviation
~. 7 AF Bandwidth
With pre-emphasis 30Hz to 15KHz
Without pre-emphasis
30Hz to 20KHz
~. 8 Audio Pre-emphasis
50 microsecond
4 . 9 Amplitude Vs Freq. Response
0.5 dB between 30Hz to 15KHz
for audio (with 50%
modulation)
4 . 1 0 Harmonic distortion (audio)
::;0.5% within 30 Hz to 15KHz for
100% modulation 1.e. 50KHz
deviation.
4 . 1 1 FM Noise (Unweighetd) Better than -60dB with respect
to100% modulation
(Weighted)
-66dB or less
4 . 1 2 AM Noise (without -45dB or better
modulation)
4 . 1 3 Synchronous AM Noise (with -40 dB or better
100% modulation)
Table2
R fh A r d VI f mpltu e s requency esponse0 t evIsiontransmitter:
Freq. relative to carrier in Limits (dB) Limits (dB)
MHz maximum Minimum
-4.43 -30
-
-4.43 to -1.25 -20 -
-1.25 to -0.75 +0.5
-
-0.75 +0.5 -4.0
-0.5 +0.5 -1.5
oto 1.5 +0.5 -0.5
+1.5
Reference -
+3.0 +0.5 -0.5
+4.43 +0.5 -0.5
+5.0 +0.5 -2.5
+5.5 -26
-
DG:DD/TxD/IOkW 12012/EV I
Page 26 of 68
S. Site/
Temperature
Ambient
HAMSL Storage
No. Region
rangeout side
temperature
/transport
rangefor
temperature
operation&
Relative
humidity:
(1) (2)
(3)
(4)
(5)
(6)
1. Jammu -lOoC
to
0 Cto +45 C 3000M
-lOoC to
Region
+45C 95% non
+50C
condensing
2. Srinagar
-20C to
0 Cto +45 C 2500M
-20C to
Region
+45C 95% non
+50C
condensing
3. Leh
-45C to 0 Cto +45 C 4500M
-45C to
Region
+45C 95%non
+50C
condensing
Table3
a) Environmental Conditions for transmitter and all associated equipment (unless
otherwise mentioned in this specifications elsewhere, In that case relevant
clauseof specification will beapplicable).
b) Rain: Upto 10cm/hr
23.Compliance Statement:
a) All thevolumes of theentireTechnical bids must bepagenumbered sothat
information required in(h) belowcanbefurnished bythebidder.
b) The compliance statement for all the paras, sub-paras listed in these
specifications, terms and conditions and all annexures is a mandatory and
anessential requirement.
c) A ParabyPara, compliance statement should beattached withthetechnical
offer. The compliance for specifications of each item/equipment offered
with the system must be provided by the respective OEMs only with all
supporting documents and data sheets for evaluating the full merit of the
offeredtransmitter system.
d) Thecompliance statements must beprovided by respective OEMs only on
their letter heads duly signed by the OEMs clearly indicating name &
designation of thesignatories.
e) Thecompliance statement shouldbecountersigned bythebidder.
f) Any offer without proper compliance statement shall be rejected without
making anyreferencetothebidder.
g) All the required technical literature/data sheets and other supporting
documents to verifY the parametric values shown in the compliance
statement must beattached withoffer toevaluate thefull merit of theoffer.
This isamandatory requirement.
DG:DD/TxD/IOkW /2012/EV /
Page 27 of 68
h) The OEM/bidder must provide the page number reference, in column (4) of
the table given in Para (j) below, of the Technical bid clearly indicating the
volume number also if any, for each supporting document to verify the
parametric values shown in the compliance statement. This is a mandatory
requirement.
i) Mere signing of DD Specs sheets shall not be treated as compliance
statement.
j) The compliance statement must be given in the following format only.
Para DD spec Quoted items The page no. of the Compliance Remarks
No. of value & value and details, offer/Technical bid, OR
DO Details as per the data where the Deviation
Spec. sheet of offered information!
system. supporting document
is available.
(1) (2) (3) (4) (5) (6)
DG:DD/TxD/lOkW /2012/EV /
Page 28 of 68
ANNEXURE-I
BILL OF MATERIAL FOR (1+1), 10KW UHF Band IVIVAnalog TV
TRANSMITTER SYSTEM &STATION ITEMS FOR THREE LOCATIONS IN J &K
BILL OF MATERIAL FOR (1+1), 10KW UHF Band IVN Analog TV TRANSMITTER SYSTEM &
STAnON ITEMS
MAKE/
Qty
~ty Qty
Jammu Srinagar Leh
S.NO.
DESCRIPTION
MODEL
Ree:ion Ree:ion Ree:ion
ESSENTIAL ITEMS (FROM S.No. 1to 17) (To beconsidered for determining the
lowest Tender)
1.
10kW, UHF, BAND IVN, Analog
ISet ISet 1Set
Transmitter (common amplification
complete complete complete
type) in(1+1) mode, upgradable to
in all inall inall
DVB-T2 Transmitter, as per DD
respect respect respect
specifications with all required items
including, and not limited tothe list
given below.
(A) Each of the two 10kW UHF TV
Transmitter of (1+1) mode consisting
of:
(a) Exciter with inbuilt power supply
(b) Power amplifiers with inbuilt power
supply
(c) Liquid pump assembly with
redundancy including all pipes and
accessones
I
(d) Heat exchanger unit with redundancy
of fans to work for temperature range as
mentioned in Table 3of DD Specs.
(e) Transmitter control unit with
necessary software and Display.
(t)Output Band Pass Filter.
(g) Transmitter output with 3W' EIA
unflanged
(h) Any other item(s) for completion of
system.
(B) Common items for 2transmitters
of(I+I) mode:
(a) Auto Control Unit with necessary
software and display.
(b) Installation, Maintenance &
Operational Manuals &test data
(c) Extender module( s) for PA and
Exciter.
(d) Essential tools for installation and
DG:DD/TxD/10kW /2012/EV /
Page29 of 68
maintenance of cooling system
alongwith spare coolant and coolant
filling arrangement.
(e) Any other item(s)
2. OUTPUT COAXIAL EQUIPMENT
2.1
DUMMY LOAD Forced air cooled, 10
1No 1No 1No
kW RMS power, UHF Band IVNAs
IperDD Specs Annexure 11-6
2.2
Broadcast Power Monitor, UHF Band
1Set 1Set 1Set
IVN,with suitable line section and
elements As per DD Specs Annexure II-
I
3.
INDOOR COAXIAL FEEDER COPPER COMPONENTS ONLY (AS PER
THE ACTUAL INSTALLATION REQUIREMENT IN THE EQUIPMENT
CONTAINER) as per DD Specifications given inAnnexure 11-2
3.1
3 W' EIA Straight Transmission Line
8nos. 8nos. 8nos.
Sections (VSWR<1.05) Sections of
length 5Meters. (Copper only)
3.2
3W' EIA 90 DEG ELBOW (Copper
30 nos. 30 nos. 30 nos.
only) (VSWR<1.05)
3.3
Straight Coupling 3 W' EIA (Copper
60 nos. 60 nos. 60 nos.
only) (with inner and outer conductor
and two nos of hose clamps for each
Straight coupling) (VSWR<1.05)
3.4 Fixed Hanger Assy 3W' EIA
20 nos. 20 nos. 20 nos.
3.5
3 lis" EIA Flange to Non flange adopter
4nos. 4nos. 4nos.
(Copper only) (VSWR<1.05)
3.6
R.F. Coaxial Switch with mounting
arrangement as per Specifications in
2Nos. 2Nos. 2Nos.
Annexure 11-2-B
4.
INPUT &MONITORING EQUIPMENT (Asper DD Specs Annexure NoII-
3) CONSISTING OF :
4.1
19" STANDARD RACK WIRED
2Nos
~Nos 2Nos
WITH ACB PANEL(Input Rack and
Monitoring)
4.2
VIDEO EQUALISING DA comprising of:
(a)
Video equalizing amplifier with clamp
~Nos 2Nos 2Nos
(b)
Mounting frame, looping inputs with and
I2No 2No 2No
extender card.
(c)
Redundant power supply
2No ?No
2No
4 . 3
lOX2Audio, Video married switcher with redundant power supply and
extender card consistine; of:
,OOfT,O/lOkW/2D12/EV/ \~
.
Page30 of 68
DG
4.3.1 10X2 Audio, Video married switcher
ISet ISet ISet
with redundant power supply, local
Programmable Push Button and extender
card
4.3.2 Mounting tray for external power supply INo INo INo
4.4 AUDIO JACK PANEL-(N/C)
INo INo INo
4.5 AUDIO PATCH CORD (2ft) lONos 10Nos lONos
4.6 VIDEO JACK PANEL-(N/C) 2X24 ISet ISet ISet
WITH 5NOS (2ft) PATCH CORD
4.7 8W Audio stereo Monitoring Amplifier ISet ISet ISet
with compatible loud speaker as per DD
Specifications
4.8 Audio Distribution Amplifier housed in 2 Sets ~Sets ~Sets
asuitable frame with redundant power
supply & extender card
(a) Stereo analog audio distribution
amplifier (4 stereo balanced outputs)
(b) Audio DA mounting frame, including
plug in audio connectors, one power
supply and power cord.
(c) Power supply for the above frame, 85-
270 volts
4.9 Audio Processor using DSP INo INo INo
4.10 AMPLISPEAKER
INo INo INo
5 MEASURING&MONITORING EQUIPMENT
5.1 Colour Test Pattern and Tone Generator INo INo INo
As per DD Specs Annexure No 11-8-1
5.2 WA VEFORM MONITOR As per DD 2Nos 2Nos 2Nos
Specs Annexure No 11-4
5.3 2:29" LCD TV Receiver with VHF/UHF
I4Sets 4Sets 4Sets
PAL-G Tuner, AV input facility, Vagi
antenna and twin RF cable for off Air
RF Monitoring (Only Reputed Brand
like
Sony/Panasonic/Hitachi/Samsung/LG/
JVC isto be quoted)
5.4 VU Meter Assy, with Power Supply
INo INo INo
Unit etc complete As per DDSpecs
Annexure No 11-3-M
5.5 R.F. Analyser As per DD Specs
1Set 1Set 1Set
Annexure No 11-7-B
6 MISC ITEMS FOR MONITORING &MAINTENANCE
.(i) RF POWER METER WITH POWER
INo INo INo
SENSOR (milliwattmeter) As per DD
DG:DD/TxD/10kW /2012/EV /
Page31of 68
Specs Annexure No 11-10
(ii) STEP ATTENUATOR (0-110dB) As 1No 1No 1No
per DD Specs Annexure No 11-8
(iii) ATTENUATOR 3dB (N type) As per 1No 1No 1No
DD Specs Annexure No 11-8
(iv) ATTENUATOR 6dB (N type) As per 1No 1No 1No
DD Specs Annexure No 11-8
(v) ATTENUATOR 12dB (N type) As per 1No 1No 1No
DD Specs Annexure No 11-8
(vi) REDUCER 3 1/8" unflanged to N 1No 1No 1No
Female As per DD Specs Annexure No
11-2
(vii) REDUCER 3 1/8" unflanged to 15/8" 1No 1No 1No
Female As per DD Specs Annexure No
11-2
8 Computer with 800V A UPS and Printer- 1Set 1Set 1Set
Laserjet as per DD Specifications given
inAnnexure 11-5
9 1. TECHNICAL MANUALS of all Total Total Total
equipments provided as per BOM. 5Sets 5Sets 5Sets
a. One sets of all manuals per order
forDGDD.
b. Two sets of all manuals for Zonal
Office per order.
c. Two sets of all manuals for the
station.
2 . Video DVD showing complete Total 3 Total 3
alignments, measurements, Sets Sets Total 3
replacement of LDMOS etc. Sets
a. One set for the station.
b. One set for the Zonal Office.
c. One set for the Dte.
10 ANY OTHER ITEMS FOR 1Set 1Set 1Set
COMPLETING THE SYSTEM
11 C and Ku Band Satellite Receive Equipment As per DD Specs Annexure No 11-
9
11.1 4.8 M C-Band solid type PDA system 2Sets 2Sets 2 Sets
with de-icing kit 100% full surface complete complete complete
including dual port motorized feed
and necessary mounting accessories.
11.2 C-Band LNBC units with de-icing kit 4Sets 4Sets 4Sets
DG,DD/T,D/lOkW/2D12/EV/ ~ if Page32 of 68
11.3
Low Loss Feed Cable from LNBC to
~Nos. x 2Nos. x 2Nos.x75
IRD
75m
75m meach
each
each
11.4
Professional IRD unit for C band and Ku
~Nos kNos 4Nos
reception (3Nos. for each)
11.5
2.4 Mtr Ku-Band dish antenna with Feed
ISet ISet lSet
and necessary mounting accessories
(with slanting shed for snow/rain
protection)
11.6
Ku-Band LNBC units
')Nos
2Nos 2Nos
11.7
Low Loss Feed Cable
"5Mtr 25Mtr 25Mtr
12
Installation, testing and commissioningof:
12.1
1+1 Transmitter System with cooling
1Job 1Job 1Job
system and remote/local monitoring and
control system
12.2
Input, Monitoring and measuring
1Job 1Job 1Job
equipment with wired racks
12.6
Satellite receives equipment for C Band
1Job 1Job 1Job
(PDAs, feeds, LNBCs, IRDs, Cables)
including foundation of 6.2 M PDAs.
12.7
Satellite receive equipment for Ku Band
1Job 1Job 1Job
(PDAs, feeds, LNBCs, IRDs, Cables)
including mounting of
2.4 M PDAs.
13(a)
Inspection of Transmitter at OEM's
1Lot
Works and Factory Acceptance Test by
2DD Engineers
14
Training for 5DD Engineers at
1Lot
Transmitter OEM's Works
15
AnyOther itemstocompletethe
1Job 1Job 1Job
turnkey job asper specifications(if
any, breakup detail maybe2iven)
OPTIONAL ITEMS (Not tobeconsideredfor Ranking)
1
Hardware and Software for making the
1Set 1set 1set
Transmitter operational as DVB- T2
Transmitter.
Incasethebidder quotes theoptional
itemsas"aset", thedetails of the
components/items offeredinthe"set"
must bespeIt out clearly.
DG:DD/TxD/10kW /2012/EV /
Page 33 of 68
2 Maintenance Spares for
1Set 1Set 1Set
1. PA
complete complete complete
2. PA Power Supply
3. Exciter
4 . Any other critical Spares as
recommended by the Transmitter
OEM
5. Jigs for PA and Exciter
Note: Please refer to Para 7.
In case the bidder quotes the optional
items as "a set", the details of the
components/items offered in the "set"
must be spelt out clearly.
DG:DD/TxD/10kW /2012/EV /
Page 34 of 68
Annexure 11-1
Specifications of 10kW Broadcast Power Monitor (THROUGH LINE
POWER METER):
1.Introduction:
1.1Broadcast Power Monitor, UHF Band IVN, with 3 Ifs"EIA unflanged line section
and suitable elements for measurement of Maximum Forward power of 10 kW and
reflected power of 1.0kW, VSWR, Return Loss etc.
1.2 Ethernet & RS 232 enabled- Remote monitoring, control & instant alarm alert
with 50 feet of cable to connect RS 232 and serial port between monitoring unit and
line section, and serialinterface cable.
1.3Data logging capabilities - System trends and anomalies before failure.
1.4Integral RF Test Port facility.
1.5Frequency/Channel field configurable.
mca ,peci IcaIons:
S.No. Description
Technical Specification
a. Accuracy
5% of reading
b. Connector
3Ifs"EIA UnFlange
c. Frequency Range
470 to 862 MHz
d. VSWR
<1.10: 1
e. Impedance(N ominal)
50 Ohm Nominal
f. Alarms
No/Low Forward power,
High forward power, VSWR
g. AC Power
Single Phase, 230 volts
10%, 50Hz 2%
h.
Temperature of Storage
As Per Table 3
1.
Temperature of Operation
j. Humidity
k. Max Altitude
1. Display
Broadcast power monitor
should display on screen
Forward Power, Reflected
power, VSWR, Return Loss
(as mentioned in 1.1above)
m.
Coupler Directivity
28 dB minimum
n. Dimensions:
To be specified by the OEM
(Length x Width x Depth)
mmm
o. Weight
To be specified by the OEM
inkg
2. Tech' IS 'fi f
DG:DD/TxD/lOkW /2012/EV /
Page 35 of 68
Annexure 11-2
A. Specifications of Indoor Coaxial Feeder CuComponents:
1. Introduction:
1.1All theindoor co~xial feeder components must beof highquality copper, usedfor
broadcasting systemfor agoodtransmission performance.
1.2TheVSWR of all coaxial feeder components must belessthan 1.05.
1.3Thereshouldbeafirmgripbetween various coaxial feeder components.
1.4All thecomponents shouldbecapableof handlingthepower supplied at theoutput
of thetransmitter.
1.5Spacersmust beusedat asuitablelengthbetween inner andouter conductor.
B.Specifications for 15kWMotorised R.F.Coaxial Switch:
1. General:
1.1The l5kW(Avg.) Motorised RF Coaxial Switchshall take input fromtwo Nos. of
10k WUHF TV Transmitters operating in (1+1) mode. The Output of either of the
two transmitters should be connected to Antenna through RF feeder cable and the
output of other Transmitter shouldbeconnectedtotheDummy load.
1.2The equipment should be rugged, reliable and stable in operation under Indian
tropical condition. Theclimatemay varyfromverycoldtohot, humid&dusty.
1.3It shouldbecapable of fast switching between Transmission lines. TheMinimum
Cyclesof operationwithout failuremust alsobespecifiedbytheOEM.
1.4It shouldbecontrollable through ACU of thetransmitter systemboth locally and
inremotemode.
1.5In addition, manual operation must also be possible. It should have minimum
movingparts.
1.6Incaseof failureof switch, provision for bypassing it andconnecting theoutput of
either of the transmitters to the antenna should be there with minimum service
breakdown.
2. Technical Specifications:
2.1Frequency of operation: UHF BandIVNDC to 860MHz.
2.2Impedance: 50n
Power Rating: 15kW(Average)
InsertionLoss: O.ldB Max.
VSWR: <1.05.
2.3OperatingTemperature: Asper Table3
2.4Isolation: Better than70dB
2.5Motor Power Supply: 230V 10%AC Mains, 50Hz 2%
2.6Weight: Tobespecified bytheOEM.
2.7RF Connector: EIA withadaptor tomatewithunflanged Transmission Line.
DG:DD!TxD/lOkW/2D12/EV/ ~ & Page36 of 68
2.8 Switching Time: 3sec(nominal)
2.9 Interlock: Provision in ACU /Control System of Tx that RF is OFF before RF
Switch operates.
2.10 The Switch should have provision with manual over-ride, mechanical position
indicator and auxiliary read-out circuit
2.11 Mounting arrangement: To be mounted on Top of Transmitter.
Annexure 11-3
Specifications of Input, Monitoring equipment and Racks:
A. Specifications of Standard 19" Rack:
i) The input and monitoring rack should be suitable for:
Feeding video and stereo/mono audio programmes to TV transmitters &
ii) Metering/monitoring of different programme input sources as well as signal
at intermediate points inthe audio/video chain.
Detailed specifications of rack and individual equipment are given below.
1.0 GENERAL DETAILS:
1.1 Complete equipment wiring and other details are to be worked out by the bidder.
The details of equipment to be installed inthis rack isto beprovided by the bidder.
1.2 All audio/video lines from the Jacks &Equipment are to be connected to a
terminal block to be located near the bottom of the rack for external feeding of cables
by the bidder. All the equipment are to be properly earthed with the existing
equipment earthing system inthe transmitter hall.
1.3 RFI/EMI filter should be provided at mains input of the rack as per relevant
provisions of FCC rules and regulations, or equivalent standards for effective rejection
of the interference from the high power transmitters operating in the premises. These
racks will be used in High Power Transmitter halls i.e., the rack with full complement
of equipment has to operate in a high RF field. As such all the specifications of the
individual equipment as well as the full chain, areto remain valid inhigh RF fields.
2.0 EQUIPMENT RACK:
The standard 19" rack will have various equipment. The frame of the rack should be
of high quality extruded aluminium or high grade steel material as per relevant
material codes. The aluminium profiles should be either anodized or powder coated
and the steel parts should be enamelled to give pleasing and aesthetic look and
superior and long lasting paint finish. The rack is to be of sturdy design. The width
should be suitable for mounting of standard 19" equipment. Doors should be provided
on the rear side and should have louvers and exhaust fan to facilitate proper
ventilation. The overall size of rack should be2000 (H) x 545 (W) x 600 (D) mm.
2.1 Input/Output Isolation 90 dB
2.2 Input/Input Isolation 90 dB
DG:DD/TxD/IOkW /2012/EV /
Page 37 of 68
B. Specifications of VideoEqualizing Distribution Amplifier:
1. The system should be high-performance, having high reliability of professional
quality, analog video equalizing distribution amplifier.
2. It should have high quality mounting frame for mounting it instandard 19" rack.
3. It should be capable of amplifying composite and component analog PAL signals,
with or without sync and subcarrier signal.
4. The amplifier must have adjustable gain inthe range 3dB.
5. The amplifier should have at least 8outputs and one differential input.
6. It should have redundant power supply.
7. Technical Parameters:
Sr. No.
1.
2.
3.
4.
S .
6.
7.
8.
9.
10.
13.
Parameters
230VAC10%, SOHz 2%.
SOC to 4 SoC
1V p- nominal
7S0
DC
>6S
>4SdB
>40dB
O.OSdB(DC to 10MHz)
O.OSdB(DC to SMHz)
>70dB
C. Specifications of AudioVideoSwitcher
1. The Video Audio switchers should consist of a video switching module &
audio switching module with a Control logic board for audio to follow video
operation with basic configuration of 10 inputs and 2 outputs (10x2) with
integrated redundant power supply.
2. Buttons per cross point Control lines should be available to permit Control
from front panel through illuminating momentary push button.
3. Switching should be selectable between instantaneous (non-vertical intervals)
or as vertical interval reference.
4. The audio, video and power supply connection should be on the back side of
the unit. The switcher should have following technical specifications.
S. Description Specification
No.
1. Standard PAL colour standard
2 . 0 Video inouts
2.1 No. Of inputs 10Nos. with loop through facility
2.2 Input signal 1V p-p nominal (CCVS)
level
DG,DDfT,D!lDkW!2D12!EV! ~ ~ Page 38 of 68
2.3 Input
High impedance for loop through inputs, terminable into
impedance
75 Ohms through termination plug.
2.4 Return loss
Better than 40dB upto 5MHz, across 75 Ohms
3 . 0 Video outputs
3.1 No. of outputs a) 2 (Two) buffered output
b) 2 (Two) for monitor bus
3.2 Output signal 1Y p-p nominal (CCYS)
level
3.3 Output 75 Ohms Unbalanced
impedance
3.4 Isolation Better than 35 dB
between
buffered output
4 . 0 Video Performance
4.1 Gain
Unity, 1.0dB adjustable(internally)
4.2 Frequency O.ldB from DC to 5MHz
response 0.5 dB from 5MHz to 8MHz
4.3 Differential Better than 0.3%
Gain
4.4 Differential Better than 0.3
Phase
4.5 Line frequency 0.5%
tilt
4.6 Field frequency 0.5%
tilt
4.7 Signal to noise Better than 75
dB (weighted) at rated input & output
ratio levels
4.8 Cross talk
Better than 60 dB referenced to 1Y p-p at 5MHz
4.9 Connectors BNC (for inputs & outputs)
5 . 0 Audio inputs
5.1 No. of inputs 10nos. balanced
5.2 Inputs signal
+8dBm nominal, +20 dBm maximum at 600 Ohms
level
5.3 Input 600 ohms, Balanced
impedance
5.4 Input connector XLRfemale
6 . 0 Audio outputs
6.1 No. of outputs
2 (Two) for program & 2(Two) for monitor bus
6.2 Output signal +8 dBm nominal
level
6.3 Output
600 Ohms balanced
impedance
6.4 Output XLRmaie
connectors
DG:DD/TxD/IOkW /2012/EV /
Page 39 of 68
7.0 Audio Performance
7.1 Gain
Unity, 1.5dBadjustable
7.2 Frequency
0.1dB (20Hz to20KHz)
response
7.3 Crosstalk
Better than 70dB (20Hz to 15KHz)
7.4 Signal to noise
90dB referenced to+8dBm
ratio
7.5 Harmonic
Better than0.1%(20Hz to20KHz at +20dBm)
distortion
9.0 General
9.1 Power supply
Operational on both 24 Vdc and 230 Vac +/- 10%, 50
Hz2%
9.2 Operating Asper Table3
temperature
9.3 Storage
temperature
9.4 Relative
humidity
9.5 Dimensions
Height tobespecifiedinRU for 19" rack
9.6 Control
PushbuttonControl onfront panel
D. Specifications of Audio Jack Panel-(NJC) 2x24
Thejack strips must be of high quality with positive contact and of twin type for
stereo/mono signals. All thecontacts shouldbesilver plated.
E. Specification of Video Jack Panels: Thejack strips of 20points each must
beof highquality. All thecontacts shouldbesilver plated.
F. Audio Patch Cords (2ft)
10nos. of stereo patch cords aretobeprovided for patching purposes. Their lengthis
tobe2ft. andshould beof high quality, durableaudio cableandjacks and should be
matchedwithAFjack panel.
G. Video Patch Cords (2 ft)
10nos. of video patch cords areto beprovided for patching purposes. Their lengthis
tobe2ft. andshould beof highquality, durablevideo cableandjacks and should be
matchedwithvideojack panel.
H. Specifications of Audio Stereo Monitoring Amplifier 8 W
1.0 TECHNICAL SPECIFICATIONS:
Theamplifier shouldessentially havethefollowing features:
DG'DD/TxD/1DkW/2D12/EV/ ~7 ~ Page 40 of 68
1.1 Protection against current over-loads:
The amplifier output should get muted in case of overload and revert to normal
functioning once overload ceases to exist.
1.2 Protection against thermal overload:
Temperature of power pack and heat sinks of both channels should be monitored and
the amplifier should get muted with a visual indication whenever temperature exceeds
permissible limits. In case of excessive temperature of heat sinks, the amplifier should
be protected.
1.3 Monitoring amplifier output should be continuously monitored for DC
components or very low frequency components which might endanger speakers if
present for longer durations. Amplifier output should get blocked in such an
eventuality.
1.4 The amplifier should have protection against open circuit, full short circuit,
ultrasonic frequencies and high RF fields.
1.5 It should be switchable to stereo and dual mono operating modes.
1.6 Necessary function switches such as volume/gain control, low and high filters
should be available on front panel. These controls should be rugged and reliable.
S.No. TECHNICAL SPECIFICATION
PARAMETER
1 . 1 INPUT
1 . 2 No. of input (stereo) 1set (2 mono)
(XLR female connectors)
1 . 3 Input level -10 dBu to +10 dBu for rated output.
1 . 4
Input impedance >10k ohms (balanced)
1 . 5 CMRR (20 Hz-20 kHz) >60dB
2 Power Output
8 W rms (40 W peak music power) per
channel at 8 ohms nominal impedance at
suitable terminals.
2 . 1 Frequency Response 0.5 dB
With reference to 1 kHz over
the entire range of 20 Hz to 20
kHz.
2 . 2 Total Harmonic Distortion at 1 <0.5% at rated output
kHz.
2 . 3 Signal- to-noise- ratio 85 dB or better.
With input shorted and at
rated output (unweighted rms)
at .dBu input (22 Hz-22 kHz)
2 . 4 Damping factor >75 into 8ohms at <1kHz
DG:DD/TxD/10kW /2012/EV /
Page 41 of 68
Parameters
230VAClO%, 50Hz2%.
As er Table3
28dBu (Maximum)
660
25dBu (Minimum)
>85dB
>85dB isolation
>70dB
0.05dB (20Hz to 20KHz)
-90to 30dB in0.5dB ste s
>90dB
2 . 5 Power supply
Theamplifier shall work on230V 10%,
50Hz 2%singlephaseAC supply.
2 . 6 Level difference between the Equal to or lessthan 0.5dB
channels
2 . 7 Phase difference between the
< 10 inthe frequency range 20 Hz to 20
channels
kHz
2 . 8 Inter-channel X-Talk at 15 >75 dB at nominal level
kHz
2 . 9
Accessories: All necessary accessories like power cord and mating
connectors shall besupplied along withtheunits. Thestandard accessories
should be clearly mentioned inthe quotation. Also, optional accessories if
considered useful/recommended by theOEM should bequoted separately.
3. MECHANICAL:
Theamplifier should be 19" rack mounting type for mounting in standard 19"
rack.
I. Specifications of Audio Distribution Amplifier with Suitable Frame and
Redundant Power Supply and Extender Card
1. Thesystemshould be high-performance high reliability, Analog audio distribution
amplifier.
2. It shouldbeof professional quality.
3. It shouldhaveflat frequency response, acontrolled roll-off andvery lowdistortion.
4. The Isolation between the modules must be better than 90dB for audio frequency
band.
5. Theamplifier should beconfigured to 8outputs designated to one input.
6. It shouldhavebalanced input andoutput.
7. Technical Parameters:
S. No. "Descri tion
1. Power su ly
2. 0 eratin Tern erature
3. In ut level
4. out ut 1medance
5. Out ut level
6. CMRR
7. Crosstalk
8. Out ut Isolation
9. Fre uency Res
10. GainRan e
. 11. SINratio
J . Specifications for Audio Processor
1. Introduction:
DG:DD/TxD/lOkW /2012/EV /
Page42 of 68
a. It should be a high quality stereo/dual mono audio processor for Analog
television audio, but should have digital signal processing only.
b. The equipment should be rugged, reliable and stable in operation under
Indian tropical condition. The climate may vary from very cold to hot,
humid &dusty.
c. It should provide sound with good loudness control at its output as well as
preserve the frequency balance of original sound while controlling
subjective loudness.
d. It has to process audio available in the transmitter from a professional IRD
(Satellite receiver) or aT.v. studio.
e. LCD/LED type meters on front panel for adjustment of parameters as well
as for displaying required parameters for monitoring.
f. It should be a standalone unit with built in tone generator for standard audio
test tones upto 15kHz.
g. As the audio processor will be installed in very high R.F. field environment
of 10kW UHF T.V. Transmitters, it should have proper R.F. Shielding.
h. It must have Stereo Enhancement, Equalization, and AGC with look-ahead
peak limiting.
1. It must have Stereo Enhancement, Equalization, and Multi-Band processing
(at least 5Band, including AGC) without look-ahead peak limiting.
J . The bypass test facility ofthe unit must be available.
k. The detailed technical specifications are provided below:
2. Technical Specifications of Audio Processor:
(a) Analog Audio Input
1. Configuration: Stereo/Dual-Mono.
11. Impedance: >10k nload impedance, electronically balanced.
111. Nominal Input Level: Software adjustable from -4.0 to +13.0 dBu (VU).
IV. Maximum Input Level: +27 dBu.
v. Connectors: Two XLR-type, female, EMI-suppressed. Pin 1 chassis ground,
Pins 2 (+) and 3 electronically balanced symmetrical.
VI. Processing: Digital Signal Processing (DSP).
V11. Filtering: RFI filtered.
(b) Analog Audio Output
1. Configuration: Stereo, Flat or pre-emphasized at SOilS.
DG:DD/TxD/10kW /2012/EV / Page 43 of 68
11. Load Impedance: 600n,balanced or unbalanced.
111. Output Level (100% peak modulation): Adjustable from-6 dBu to +24 dBu
peak, into600ohm, software adjustable.
IV. Signal to Noise Ratio: ~ 90 dB unweighted (Bypass mode de-emphasised, 20
Hz-IS kHz bandwidth, referenced to 100%modulation).
v. L/R Crosstalk::S -70dB, 20Hz-IS kHz.
VI. Distortion::S 0.01% THD (Bypass mode, de-emphasised) 20 Hz-IS kHz
bandwidth.
V11. Connectors: Two XLR -type, male, EMI-suppressed. Pin 1chassis ground,
Pins 2(+) and 3electronically balanced, floating andsymmetrical.
V111. Filtering: RFI filtered.
3. General Parameters
1. Input Voltage: Singlephase, 230Volt 10%,50 Hz 2%.
11. Input Power Connector: IEC, EMI-suppressed. Detachable 3-wire power
cordsupplied.
111. Grounding: Circuit ground should be independent of chassis ground, and can
beisolated or connected.
IV. Safety Standards: As per latest international standards.
v. Operating Temperature: As per Table3
VI. Humidity: As per Table3
V11. Mounting: 19" Rack mounting, height must bespecified by bidder inRU.
Vlll. RFI / EMI: According to latest International standards.
IX. Weight: Must bespecified by bidder inKg.
K. Specification of Amplispeaker
Page 44 of 68
The system should be high grade transducer of professional audio monitoring
quality.
DG:DD/TxD/l0kW /2012/EV /
2 Unit must haveanON/OFF switchwithLED indication and alevel control.
3 Transducer components likeWoofer andTweeter must bemagnetically shielded.
4 Technical Specifications:
Sr. No. Description
Parameters
1. Power Supply
230VAC10%, 50Hz 2%.
2. Amplifier power without LF-45W, HF-45W
clipping
3. SINratio
>90dB
4. Gain control range
6dB
5. Volume control range >70dB
6. CMRR
>65dB
7. Protection
Over current, Over heat, RFI,
Switch On/Off transients.
L. Broad Specification of Loudspeaker
General:
1. This specification pertains to professional high quality, studio monitoring
stereo loudspeaker systemfor continuous useinBroadcast Transmitter.
2. The loudspeakers shall be high fidelity three way speaker system based on
state-of-the-art technology.
3. The enclosure of the speaker shall be of rugged structure and of alterative
design.
4. Theloudspeakers must beobtained directly fromthemanufacturer.
5. Thepower handling capacity of each of the matched loudspeaker shall be 125
watts, continuous pink noise.
6. Nominal impedance shall be8ohms.
7. The speaker system shall have frequency response within 2 dB between 45
Hz to20kHz withrespect to 1kHz.
M.Specifications of VUMeter
1. General:
1. It should beastandalone unit, simpleto operateand 19" rack mount.
2. It must beaprofessional level monitoring inbroadcast systems.
3. Theunit should haveat least two Analog input (XLR type).
4. Theinput rangemust beat least lOdB.
5. Unit should havethefacility of internal speakers.
ec RIca IpeCI lca IOns:
S.No. Description
Parametric value
2 . 1 Input Impedance
600ohm.
2 . 2 MaximumInput level
20dBu.
2. T h' I S 'ft f
DG:DD/TxD/l0kW /2012/EV /
Page45 of 68
2 . 3 Frequency of operation 20Hz to 20KHz.
2 . 4 Accuracy 1dB.
2 . 5 Distortion <0.1%.
2 . 6 SIN Ratio 2:80dB.
DG:DD/TxD/lOkW /2012/EV / Page 46 of 68
Annexure 11-4
Specifications of Waveform Monitor
1.
1.1
1.2
1.3
2.
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.8
2.9
2.10
2.11
SCOPE:
Doordarshan Requires 2Input Analog andDigital waveformmonitors for itsTV
Transmitters. These waveform monitors will be as per the technical
specifications of Doordarshan. The waveform monitors should be rugged,
reliable and stable inoperation.
TheWaveformmonitors should bequoted with product's detailed specifications
datasheet pamphlets &operation Manual. It will be the responsibility of the
bidder to ensure that the equipment is complete in all respects. All connectors
and cable etc required for taking measurements should be supplied with the
equipment.
The set of waveform monitors should be 19" rack mountable.
ESSENTIAL FEATURES:
The firm should offer a high precision, single unit having digital signal
processing capable of highly accurate measurement and high quality Colour
LCD based broadcast Analog andDigital waveformmonitor.
The waveform monitor should have two selectable inputs to receive two
numbers of Analog and two numbers of Standard Definition serial digital
signals.
Theoffered product should beabletoprovide real timeLCD display suitablefor
Livemonitoring.
Theoffered waveformmonitor should havethe facility to display the waveform
inOverlay andParade modeinRGB andYPbPf'
TheWaveformMonitor shouldbeableto monitor Gamut inRGB andYP~r'
It shall provide facilities for monitoring of single H pulse and dual H pulseand
monitoring ofVITS signals.
The waveform monitor offered should have the picture display function of the
video signal ontheLCD.
The WaveformMonitor should capable to display four measurements at atime,
in almost any combination such as waveform display, vector display, picture
display and status display.
The Waveform Monitor should offer remote access and control with astandard
Web-browser.
The offered waveform monitor should facilitate Eye pattern view of the
incoming selected digital video signal with Timing cursors with necessary
filters.
It should bepossible to monitor theserial transmission error of the serial digital
signal andanalyze for thecorrect format andstatus by means ofEDH codes.
It should be possible to measure the level of the serial digital signal and
displayed asequivalent lengthof coaxial cable.
DG:DD/TxD/10kW /2012/EV /
Page 47 of 68
\
',--
2.12
Theoffered product should havethefeature of Vector/Lightening display of the
colour difference signals. The vector should display user-selectable graticules,
colour targets (75%and 100%) andcolour axis.
2.13
The Waveform Monitor should have safe area graticules on the picture display
to quickly verify correct placement of graphics, Titles or logos.
2.14
TheWaveformMonitor should beableto storeat least 30presets.
2.15
TheWaveformMonitor shouldrecord error logs upto 8000events.
2.16
The Waveform Monitor should have USB Connector at the front to store the
presets.
2.17
It should have 10/100Base-T Ethernet connection andoffer remote access
2.18 It should have
SNMP
interface to allow easy integration with network
management software.
2.19
For Analog Video, the Waveform monitor must have BNC (female) input
connectors. It should also have the facility loop through of video signal to
monitor it onthevideo monitors.
2.19
All accessories like 19" rack mount kit, cabinet etc, should bequoted separately
inthis offer.
2.20 Only
internationally
reputed make and model meeting the following
specification should be quoted.
The firm should enclose the user list of the
broadcasters to whomthis product has been supplied.
3.
TECHNICAL SPECIFICATIONS:
3.1
AnaloeueCompositeInput:
3.1.1 Input
2, PAL
3.1.2 Input Type
75.Q BNC, Passive loop-through
3.1.3 Input Dynamic Range
6dB
3.1.4 Return Loss
35dB (Power Oft)
>40dB (Power On)
3.1.5 Cross Talk
>60dB to 6MHz
3.1.6
MaximumOperating
- 1.8V to+2.2V, DC +peak AC
Amplitude
3.1.7
Vertical Measurement
1%, All gainsettings
Accuracy
3.1.8 Gain
Inthemultiples of 1, 2, 5& 10
3.1.9 Frequency Response
Flat to 5.75MHz, 1%
3.1.10
SweepTimeAccuracy
0.5%
3.1.11 SweepLinearity
0.2%of timedisplayed onscreen
3.2
Serial Dieital Input:
3.2.1 Input
2, SMPTE259M, 625/50
3.2.2 Input Type
75.QBNC
3.2.3 Input level
800mVp-p 10%
3.2.4 ReturnLoss
>15dB from1MHz to 270MHz
3.2.5
Receiver Equalization
Upto250mof type 8281cable.
Range
-
'- ) (
r
"
DG:DD/TxD/lOkW /2012/EV /
~ Page 48 of 68
3 . 2 . 6
WaveformVertical Characteristics
3 . 2 . 6 . 1
Frequency Response
Luminance Channel (Y): 0.5%, 50KHz to 5.75
MHz
Chrominance Channel: 0.5%, 50KHz to2.50
MHz
3 . 2 . 6 . 2
Vertical Measurement
At IX: 0.5%; at 5X: 0.2%of 700mV full scale
Accuracy
mode.
3 . 2 . 6 . 3 Gain
Xl, X5andXI0
3 . 3
Serial Di2ital Output
3 . 3 . 1 Signal format
270Mbps
3 . 3 . 2 Output level
800mVp-p 10%across 75n load
3 . 3 . 3 Return loss
15dB, 1- 270MHz
3 . 4
Eye Pattern Display (For Eye Pattern confi2uration)
3 . 4 . 1 Type
Equivalent Timesampler
3 . 4 . 2 Bandwidth
Supported format SMPTE 259M, 270Mbps
3 . 4 . 3 J itter Filter:
10Hz, 1KHz, 10KHz & 100KHz
3 . 4 . 4
Amplitude Accuracy
800mV 5%for 800mV input
3 . 5
Component Vector Mode
3 . 5 . 1 Vertical Bandwidth
800KHz
3 . 5 . 2
Vertical GainAccuracy
0.5%
3 . 5 . 3 Horizontal Gain
0.5%
Accuracy
3 . 5 . 4 Vector Display
Ps isdisplayed onHorizontal axis andP
R
is
displayed onVertical axis
3 . 6
External Reference
3 . 6 . 1 Synchronization
Both, Internal andexternal synchronization facility
3 . 6 . 2 Input Type
Black burst, BNC, 75n
3 . 6 . 3 DC Input Impedance
20kn
3 . 6 . 4 Return Loss
>30dB
3 . 7 Display
3 . 7 . 1 Screen Type:
Color LCD
3 . 7 . 2 Resolution:
1024X 768
3 . 7 . 3 Size:
13cmx 10cm
3 . 7 . 4 Screen:
1- screen and4- screen display
3 . 8
Power supply &operatin2 temperature
3 . 8 . 1 Input
230V, 50Hz
3 ' . 8 . 2
Operating Temperature
Pleaserefer Table3.
DG:DD/TxD/l0kW /2012/EV /
Page 49 of 68
Annexure 11-5
Specifications of Computer with 800 VAUPSand Laserjet Printer:
1.0 Scope: Doordarshan (DD) intends to procure Computer system based on latest
technology. The computers should be rugged, reliable, and stable in operation under
very coldto hot, humid and dusty environmental conditions. Detailed specifications of
theComputers aregiven inthis document. TheComputers will besupplied alongwith
Uninterrupted Power Supply (UPS) and Laser printer. The computer manufacturer /
bidder must havehis local office/ representative inIndia.
f t C fi lIe . ompu er on u!ura Ion
S.No. Description
Specification
a. CPU Intel Corei5
b. Chipset
Intel OEM Motherboard
c. Bus Architecture
Integrated Graphics, 2PCI, 1PCI Express x 1and
1PCI Express x 16
d. Memory
2GB DDR3 RAM with4GB Expandability
e. Hard Disk Drive 500GB 7200rpmSerial ATA HDD
f. Monitor
17" LED Digital Colour Monitor
g. Keyboard 104keys
h. Mouse Optical
1. Bays
4 Nos. (2 Nos. 5.25 inches for Optical Media
Drives and 2 Nos. 3.5 inches for Hard Disk
Drives)
J . Ports
6 USB Ports (with at least 2 in front), 1 Serial
audio ports for microphone and headphone in
front
k. Cabinet Mini tower
1. DVD ROM Drive 16X or better DVD ROM Drive
m. Networking
10/10011000 on board integrated Network Port
facility with remote booting facility remote system
installation, remotewakeup
n. Modem Dial up56.6kbps.
o. Operating System Windows Seven professional preloaded with
Media and Documentation and Certificate of
Authenticity
p .
OS Certifications
WinLogo Sevenprofessional OS Certification
q. Power
Screen Blanking, Hard Disk and System Idle
Management
Mode in Power On, Set up Password, Power
supply SMPS Surgeprotected
r. Preloaded
Norton, McAfee, or equivalent Antivirus (Latest
Software
Version) with 365days License and open office
DG:DD/TxD/IOkW /2012/EV /
Page 50 of 68
\, '2.. Laser Printer
S.No. Description
a Output Type
b Resolution
c Pageper Minute(PPM)
d Paper size
e Interface
f Necessary cables &Utility Softwareto besupplied.
Specification
Black andWhite
600x 600dpi
16
A4
USB 2.0
\.3. 800VA offlineUPS
S.No. Descri tion
a Ca acity
b Out ut waveform
c Voltage onMains
d Fre uenc (In ut)
e Backu time
f Frequency(on
Batte )
Transfer Time
h Over Load Indication
Charger
J
Short circuit
rotection
k Protection
Battery
DG:DD/TxD/IOkW /2012/EV /
S ecification
800 VA
Ste eda roximation to aSinewave
165-270VAC
47- 53Hz
30minutes
50Hzl%
<20milli seconds
100% for 60 seconds, Indications Via LED &
Audible alarmwith 3times restart
Constant Power, 2 step charging Input voltage
range 100- 270V
Multiple short circuit protection provided
Overload, short circuit, low battery Over charge,
Main slow& Hi hin ut volta e
Sealed Maintenance free Cold Start, No-load
Auto-Shutdown
Page 51 of 68
Annexure 11-6
Specifications of 10 kW dummy load
1. Introduction: One number 10 kW air cooled Dummy Load of 50 Ohm, is required
for 10kW Transmitters.
1.1 Low maintenance and high reliability.
1.2 Fully shielded against the production of extraneous radiation.
1.3 Manual! Automatic fan modes.
2. Technical Specifications:
S. Description Technical Specification
No.
2 . 1 Power Rating 10k W continuous RMS power
2 . 2 Connector 3W' EIA UnFlange
2 . 3 Frequency Range 470 to 862 MHz
2 . 4 VSWR ~1.10:1
2 . 5 Impedance(Nominal) 50 Ohm Nominal
2 . 6 Type of Cooling Forced Air cooled
2 . 7 AC Power Single Phase, 230 volts 10%,
50Hz2%
2 . 8 Temperature of Storage As per Table 3
2 . 9 Temperature of Operation
2 . 1 0 Humidity
2 . 1 1 Dimensions: (Length x Width To be provided by the OEM.
x Depth) in mm.
2 . 1 2 Weight (in kg) To be provided by the OEM.
DG:DD/TxD/l0kW /2012/EV / Page52 of 68
Annexure 11-7
SPECIFICATIONS OF MEASURING EQUIPMENT:
A. Specifications of Colour test pattern & Tone generator
ec mca r>arame ers:
S.No. Description
Parametric values
4 . 1 Power supply
230VAC10%, 50 Hz 2%
4 . 2 Output Connector - video/audio
BNC/XLR
4 . 3 Operating Temperature As per Table 3
4 . 4 Output Impedance - video/audio
750/120
4 . 5 Video Output Return loss
>30dB
4 . 6 Video Test signals
75% & 100% colour bar,
linearity, flat field, Multiburst,
sweep (upto 5 MHz), pulse &bar,
CCIR Line 17, 18, 330, 331,
video sweep for 250kHz to 5
MHz etc.
4 . 7 Audio Level
-48dBU to +12dBU (Resolution
IdB)
4 . 8 Audio Frequency
oto 20 kHz
1. Doordarshan requires broadcast quality colour test pattern, sync signal generator
and tone generator with test signals for analog TV transmitters.
2. It should work for PAL/625 line system.
3. The unit should have SNMP remote control facility to integrate automated service.
4 T h . I t
B. Specifications of RFAnalyser:
1. The RF Antenna Analyzer should be a precision portable instrument,
suitable for making direct measurement and analysis on transmission lines
of a "T.V. Transmitting antenna system" installed at a T.V. tower, in
proximity of high radiation. It should be capable to perform coverage
mapping, Spectrum Analysis, Field Strength measurement RF power
monitoring and provide GPS co-ordinates information. It should be a stand-
alone integrated unit, rugged in construction, light weight, battery operated,
portable and suitable to be used in tropical environment in open to air space
on T.V. tower platforms.
2. Features and Measurements required:
1. VSWR and Return Loss
DG:DD/TxD/l0kW /2012/EV /
Page 53 of 68
11. CableLoss
111. Gain, Loss or isolation of antenna and devices such as filters,
attenuators, amplifiers, etc.
IV. Distance-to-Fault (DTF) using frequency domain reflectometry, with
facility of comparison of electrical length of two cables.
v. Field Strength Measurements
VI. RF power measurement
V11. SpectrumAnalysis
V11l. GPS co-ordinate
ix. Phase Measurement
3. Technical Specifications:
3.1Antenna Testing:
i. SweepFrequency Range: VHF Band III andUHF Band IVNRange
11. Freq. Resolution: :s 100KHz for the full frequency range so that the
level corresponding to eachTV channel canbemeasured.
111. Display Points: selectable from 150 to 2000 points (selectable) for
accurate measurement of Distance toFault.
3.2Measurement Range:
1. VSWR: 1.00to 6.00 (Resolution 0.01) or better
11. Return Loss: 0.00to 50.00dB (Resolution O.OldB)or better
111. CableLoss: 0.00to20.00dB (Resolution O.OldB)or better
IV. Distance to Fault Parameters: Horizontal Range: 0to 1500meters or
better
v. This instrument should have the facility to display 'Smith Chart' for
transmission lines.
VI. The fault detection in atransmission line/cable with air and foamas
dielectric should be possible for minimum 600 meters over full
frequency range.
V11. Dynamic Range:80dB or better
V11l. Directivity(corrected for vector errors): 42dB or better
IX. Test port available onanalyser: N-type, 50ohms
x. R.F. immunity: Theanalyser shouldbeimmune to strong R.F. fieldat
least upto +15dBmor better
Xl. The built-in signal source should allow measurement of loss, gain or
isolation of devices such as filters, cables, attenuators, amplifiers and
antennas.
XII. Maximuminput level: +20dBm, 50V dc or better
X11l. Phase measurement: Instrument should be able to make 1port phase
measurement anddisplay SI Iparameter onthe instrument display.
3.3Field Strength Measurement:
i. The unit should have built-in Field Strength measurement capability
for television signals and shall be supplied with all the required
DG:DD/TxD/lOkW /2012/EV /
Page54 of 68
accessories such as standard calibrated omni-directional dipole/log
periodic antenna to cover both VHF and UHF frequency band,
suitable tripod, pole, test port cable etc. Certificate of calibration for
the Antenna should be supplied along with the goods. Correction
factor data should also beprovided.
11. Frequency range: VHF Band IIIandUHF Band IVN Range
111. Frequency resolution: better than 10Hz
IV. High stability oscillator: frequency stability 1ppmor better
v. Level resolution: O.1dB
VI. EMF voltage measurement: should be possible to measure the EMF
Voltage from -5dBIlV to +120dBIlV or better
Vll. Field Strength Measurement: should bepossible to measure the field
strength from -5dBIlV/mto+120dBIlV/mor better.
Vlli. Detection systems: Max Peak, RMS Average/Average value.
IX. Detection ScaleUnits: dBIlV/m, dBm/m.
x. Antenna type: Half wave standard dipole or logPeriodic or any other
suitable standard antenna with tripod pole to have 10M height of
receiving antenna and connecting cable of minimum 12mshould be
offered.
Xl. Received Signal strength mapping: Instrument should be able to
performcoverage mapping using software supplied with theunit.
XlI. It should be possible to make field/Signal strength measurement in
the field stamped with GPS Coordinates and overlaid over the map
captured in the unit fromGoogle Map using software supplied with
the unit. It should bepossible to savethe mapped results andtransfer
to PC or Laptop usingUSB driveor LAN.
3.4 Spectrum Analysis and Power Measurement:
3.4.1 Frequency:
1. Frequency Range: 100KHz to 3.5GHz
11. Frequency Tuning Resolution: 1Hz
111. Frequency Reference: Aging:S 1ppmor better.
Accuracy:S 2ppmor better.
IV. Frequency Span: 10Hzto4GHz in 1-2-5steps plus zero spanmode.
v. Resolution Bandwidth: 10Hzto 3MHz in 1-3steps, Accuracy 5%
VI. Video Bandwidth: 1Hzt03MHz in 1-3steps, Accuracy 5%
Vll. Selectivity(3dB): 10Hz(min)
Vlll. Level Resolution: O.ldB
IX. SSB PhaseNoise at 1GHz: better than :S-lOOdBcat 10KHz offset
x. Spurious Response: :S-90dBmfor frequencies 2: 10MHz.
Xl. Sweep time (full span): should be adjustable by the instrument
automatically according to the RBW value selected and optimized
according tothe signal applied for measurement.
DG:DD/TxD/10kW /2012/EV /
Page 55 of 68
3.4.2 Amplitude
1. Measurement Range: -150dBmto +25dBm
11. Protection against maximuminput level: The instrument should have
internal protection against the maximum input level upto
+35dBm(peak, continuous); 50V dc.
111. Average Noise Level: S-150dBm ( Frequency: >10MHz; RBW
:10Hz, OdBattenuation.)
IV. Total Level Accuracy: 1.25dB, 1dB(typical) (over full frequency
range)
v. Display Scale units: dBm, dBV, dBmV, dBIlV, IlV, mY, nW, Il
W
,
mW andW.
VI. Display Range: 1to 1OdB/division,in 1dB steps, 1Odivisiondisplay.
V11. Detection System: RMS average, Positive Peak, Negative Peak,
SampleMode, Quasi Peak
Vll1. Input Attenuator Range: 0to+50dB.
IX. Channel Power Measurement: -120dBm to +25dBm at the coupled
ports of thetransmitter.
3.5 GPS Receiver
The instrument should have built-in GPS receiver to provide the Longitude,
Latitude in six figure co-ordinates and Altitude in meters. It should be
possible to save the GPS information with trace in the internal memory.
SuitableGPS antennawithmin 5mcableshould beoffered.
4 General Features and Specifications
1. Weight: Tobespecified by theOEM.
11. Temperature Range (for operation): As per table 3.
111. Relative humidity (for operation) As per Table 3.
IV. AMSL: As per Table3.
v. Power Supply: Operable on 230V 10%AC, 50Hz mains and 12
Volt dc/ chargeable battery, with back up of at least 3 hours, should
alsohave facility of charging fromvehicle battery.
VI. Display: The analyser should have coloured LCD/TFT screen to
display themeasured traces.
Vll. The instrument should have multi-marker (min: 6) displayed on the
screen to see the return loss and VSWR at different frequencies
simultaneously.
DG:DD/TxD/IOkW /2012/EV /
Page 56 of 68
Vlll. Thesegment limit lines featureshould beavailable for pass-fail tests.
IX. The instrument should have the spectral emission mask filter feature
to confirmthetransmissions within theapproved limits.
x. Instrument should have limit line feature to create mask filter for
confirming measurements within threshold limits. If the applied
signal exceeds the threshold limits, provision should be there to
automatically save the event into the internal memory of the unit. It
should bepossible to recall the saved results frommemory to analyse
the events of violation of threshold limits.
Xl. Instrument should be supplied with USB and LAN interface and the
required software for easy transfer of saved data into PC/Laptop and
VIce-versa.
5 Plotter/printer:
a) Theanalyser should haveRJ 45interface for printing onDeskjet/laser
printers and connecting withPCs.
b) Internal memory and Storage capacity: Minimum 2000 traces and
2000 sets of instrument configurations.
6 Accessories and Options:
a) All accessories/options required for measurement of VSWR, cable
loss, return loss and Distance to Fault of T.V. transmitting antenna
and RF feeder cables, spectrum analysis, GPS and field strength
measurement arerequired tobequotedwith theanalyser.
b) Standard accessories to be supplied with the unit should be clearly
specified intheoffer.
c) Carrying case shall be offered for easy handling inthe field and safer
transportation andshall formpart of theoffer.
C. Specifications of Audio Analyser:
1. SCOPE:
The Audio Analyzer should be a precision instrument, suitable for making
direct Audio measurements of a 'T.V. Transmitter system'. It should be capable to
monitor all theAudio parameters of anAnalog TV Transmitter system.
2. Features and Measurements required:
2.1 Analog Audio measurement functions: Instrument must have the facility to
measurethefollowing Analog audio parameters of anAnalog TV Transmitter:
(i),Level
(ii) Crosstalk
(iii) Frequency
DG:DD/TxD/l0kW /2012/EV / Page 57 of 68
(iv) Total Harmonic distortion
(v) Noise
(vi) Drift
(vii) Inter modulation Distortion
(viii) Narrow band selective level
(ix) Spectral FFT analysis
3.0 Technical Specifications:-
SL. No.
Parameters
Values
1 . 0
General Data
1 . 1
Operating Temperature Range
As per Table 3
1 . 2 Humidity
As per Table 3
1 . 3 Power Supply
230V 10%
2 . 0
AudioInputs/Outputs
2.1 Connectors
BNC, two channels simultaneously operating.
2.2
Frequency Range
10Hz to 80 kHz.
2.3
Frequency response from 20
0.05dB
Hz to 20 KHz. (Referenced to
1KHz)
2.4
Common Mode Rejection at 1
2: 75 dB
KHz
2.5
Harmonic Distortion
20 Hz to 20 kHz
Fundamental Range
2.6
Maximum Input Voltage
33 Volt RMS
DG:DD/TxD/IOkW /2012/EV /
Page58 of 68
3 . Connectors
4 . 1medance
5 . VSWR
6 . Accuracy
7 . Insertion Loss
8 . RF In ut Power
9 . Construction
10. Tern erature
Annexure 11-8
MISC ITEMS FOR MONITORING AND MAINTENANCE:
A.Specifications of RFStep Attenuator (0- 100dB)
S.No. Parameters Values
1. Frequency Range DC-IGHz
2 . dB Value
0-100 dB in 1dB/1OdBsteps
(Fine/Coarse steps)
3 . Connectors BNC
4 . Impedance
50Ohms
5 . VSWR
1.2:1 (DC-500MHz)
1.4:1 (500MHz-IGHz)
6 . Acc.uracy 0.2dB (DC-500MHz)
0.3dB (500MHz-IGHz)
7 . Insertion Loss
0.5dB upto 1GHz
8 . RF input Power
Avg 2Watt
Peak
1000W
9 . Temperature As per Table 3
B.Specifications of RFFixed Attenuator 3dB, 6dB, 12dB (Ntype)
S. No. Values
1. DC-IGHz
2. 3dB, 6dB, 12dB
(each oneinde endentl )
N e
50Ohms
1.2:1 (DC-500MHz)
1.4:1 500MHz-IGHz)
0.2dB (DC-500MHz)
0.3dB (500MHz-IGHz)
0.5dB u to 1GHz
1Watt
Rug edunibody
As er Table3
DG:DD/TxD/10kW /2012/EV /
Page 59 of 68
Annexure 11-9
CBandjKu Band satellite receive equipment
A. Specifications of Professional IRDfor C-BandjKu-Band:
1.1. General:
1.1.1. The IRD should have a front panel display and one should be able to enter or
edit all the parameters for aperfect reception of the signals.
1.1.2. There should be provision for observing the BER (Pre &Post correction) for
DVB-S and CINor PER (for DVB-S2) of the signal and signal level in the front
panel.
1.1.3. IRD should be able to descramble BISS mode I and BISS-E signals.
1.1.4. IRD should have at least 10 memory setups to store channels.
1.1.5. IRD should have CI slot so that by inserting the CAM module signals can be
descrambled.
1.1.6. There should be a 60 unlock input to synchronise the IRD with external
reference video signal.
1.2. RF Parameters:
S. Parameter
Specification
No.
a. Input Frequency Range
950 - 1750 MHz
b. No. ofInputs
I No.
c. Tuning Step Size
125 KHz, maximum
d. Satellite Frequency Band
C- &Ku-Band, selectable
e. Input Impedance
75 Ohms
f. Input Connector
F-Type female
g . Input Power Range
-30 to -65 dBm per carrier
h. Image Rejection >30 dB
I. Input Return Loss
7 dB, minimum
j.
Noise Figure
20 dB, maximum
k. AFC Tuning Range
5 MHz
I. De-Modulation Method
DVB-S QPSK, DVB-S2 8PSK demodulation
m Variable Symbol Rates
1.0to 44.5 M symbol/See ( DVB-S)
1.5to 30 M symbols/see, minimum (DVB-S2)
n. Convolution Inner FEC
R=~, 2/3, %,5/6, 7/8( DVB-S option) QPSK
Rates selectable
R=2/5, ~, 3/5, 2/3, %, 4/5,5/6,8/9,9/10
(DVB-S2)
o. IF Filter Bandwidth
Automatic Selection (dependent on Symbol
Rate)
Note: ASI to SDI decompression should take place directly, i.e., not through
Analog to Digital Converter. ~ ./
DG,DDfT,D/lOkW/2D12/EV/ ~7~/'" Pag.60 olGB
1.3Audio and Video Decompression Parameters:
S. Parameter
Specification
No.
Video Resolution (all
720x 576, 704x 576, 544x 576, 480x
resolutions shall be
576, 352x 576(other standard resolutions
capable of I, P &B frame
should beselectable)
decoding)
Video Decompression MP@ML
Type
Television Standard
PAL-B
Audio Decompression
MPEG-I Layer-II audio (Stereo/
Type
Musicam, i.e. Single Mono, Dual Mono,
Stereo, andJ oint Stereo)
16.1AC-3 Pass through
1.4Transport Stream O/P:
MPEG-2 DVB-ASI onBNC
1.5Video Output Specifications:
1.5.1 Analog Video Output Specifications
S. Parameter Specification
No.
(a) Connector Type BNC (75Ohms)
(b) Quantity
1No. of analog composite PAL-B CCIR
Standard
I Level 1.6
V
p-p+/- 5%
1.5.2 Digital Video Output Specifications
S. Parameter
Specification
No.
(a) Connector Type
BNC (75Ohms)
(b) Quantity
1No. of DIGITAL output
compliant to ITU-R BT.656
Standard
I Level
800mV p-p for SDI
(d) Serial Interface
SMPTE 272-1994, 270 Mb/s (10
bit)
1.5.3 Video Performance Specifications
DG:DD/TxD/10kW /2012/EV /
Page 61 of 68
S. Parameter Specification
No.
(a) Frequency Response Within 2 dB down at 5MHz
(b) Chroma-Luma Delay 30 ns, maximum
I Field Time Distortion <2%
(d) Line Time Distortion <1%
(e) Short Time distortion <2%
(f) Differential Gain <4%
(g) Differential Phase <2
(h) Signal to Noise Ratio >55 dB (luminance weighted)
1.5.4 VBI Signal Reinsertion Specifications:
S. Parameter Specification
No.
VBI Formats WST
Supported VITC
Range of VBI lines Field I lines 7to 22 (PAL) and
corresponding lines ofField 2
Synchronisation with Within I frame
Video
Preservation of line VBI data shall be reinserted on the
numbering original line number
1.6 Audio Output
1.6.1 Analog Audio
1.6.1.1 Each analog audio output shall be presented as a stereo pair.
1.6.1.2 In the event of "Mono" transmissions, the same input channel will be output to both
left and right connectors.
1.6.1.3 In other modes ("Stereo", "J oint Stereo" and "Dual Mono"), the two input channels
will be output as left and right.
1.6.1.4 Means shall be provided to combine the left and right channels on the IRD output to
produce a mono output from stereo transmissions to accommodate those sites not
equipped for stereo transmission.
1.6.2 Analog Audio Output Specifications
S. Parameter Specification
No.
(a) Output Impedance 6000 (balanced)
(b) Number of Outputs 4, configurable as Stereo, J oint
Stereo, Single mono, Dual mono.
I Connector Type XLR Male Socket or with suitable
XLR Adopter (i.e., no terminal
block)
Page62 of 68
S. Parameter Specification
No.
(a) Output level 2-7 Volts nominal
(b) Output Format AES/EBU
I Load Impedance 110 Ohms
(d) Connector Type
XLR Male Socket or with suitable
XLR Adopter (i.e., no terminal
block)
(e) Number of Outputs 2, Stereo Channels
1.6.4 Audio Performance Specifications at 256Kbps and sampling rate of 48KHz
S. Parameter Specification
No.
(a) Peak Output Level
+18dBm into 6000 balanced
(b) Clipping Level S/W Selectable to be provided or
any preset value between +18dBu
to+25dBu.
I Sampling Rates 48 KHz
(d) Frequency Response
40 Hz to 20 kHz 2 dB
(e) THD <0.3 %at 1kHz
(t) Dynamic range 80 dB (ITU-R1Arm weighting)
(g) Crosstalk at 1kHz 60 dB, full scale (20 Hz to 20 kHz)
(h) Signal to noise ratio 55 dB (min) at 0 dBm
1.6.5 LNB Power Supply &Control
S.No. Parameter Soecification
(a) LNB Voltage
+13V (Vertical)/18 V (Horz)
polarizations switching or 19V fixed.
(b) Power Consumption 400 mA. (Max.)
I Over Current protection Fold back current limiting.
(d) LNB Power Supply & Control Receive Polarization Control by
electrical Command Via LNB-IF
feeder (High & Low band switching
Pulse for Ku Band operation).
1.6.6 Size- Mount: 19" rack mountable.
B. Specifications of Cables, connecters
2.1 An interconnecting low loss cable of length of 75 meters is required with each IRD with
suitable F male connector at each end.
2.2 The cable should be quoted in denomination of 50m &25m, which can be used
independently (i.e. as 50m or 25m) or collectively i.e. as a 75m length using a coupler
(I-Connector) in between the 50m &25m cables between outdoor and indoor units.
2.3 The total insertion Loss for cable should not exceed 15dB at 1450 MHz.
DG:DD/TxD/10kW /20l2/EV /
Page 63 of 68
C. Specifications for the LNBCinCband
2.4 Technical Specifications:
S.No.
Parameter
Specification
(a)
Input frequency range
3.4GHz to4.2GHz
(b)
Local Oscillator frequency
5.150GHz
(c)
L.O. Stability
10 PPM
L.O. Phase noise
Better than 65dBclHz @ I kHz
Better than 80dBclHz @ 10kHz (min)
Better than 90dBclHz (ciJ 100kHz (min)
(d)
Output frequency
950MHz to 1450MHz
(e)
Conversion gain
55dB (min.)
(f)
Gain response
Better thanIdB/40 MHz
(g)
Output level at
IdB
6dBm
compression point
(h)
Output Connector
F type female
(i)
Input VSWR/Output VSWR
Better than 2.5: I
U ) Noise Temperature
Better than 30deg K
(k)
Power supply requirement
Shouldwork between +15V to +24V
(I) Input flange
CPR 229
(m)
Lightening/Surge protection
Should beprovided
2.5 LNBC should be environmentally sealed against weather conditions and extremes of
temperature (as mentioned inTable 3). LNBC should also be 100%water proof.
D. Specifications for KuBand Feed, Cable, Dish, and LNBC
1. Specifications for Cables &Connectors
a. An interconnecting low loss cable of length of 75 meters the cable should be
quoted in denomination of 50m & 25m, which can be used independently (i.e.
as 50m or 25m) or collectively i.e. as a 75m length using a coupler (1-
Connector) in between the 50m &25m cables between outdoor and indoor
units with F male connector at both ends.
b. The total insertion Loss for cable should not exceed 15dB at 1450 MHz.
2. Specifications for Parabolic Dish Antenna, solid type, 2.4 M (dia) and
Feed
DG:DD/TxD/10kW /2012/EV /
Page 64 of 68
S. No. Parameter
Specification
1. Antenna type
Offset / PrimeFocus
2. Frequency
10.95GHz to 12.75GHz
3. Size
2.4mdiameter
4. 3dB beamwidth
Better than 1
0
5. Antenna Noise
At 30El: 31K (min)
Temperature
6. Gain at 12.7 Min 470.25dBi
GHz
7. Drive system Manual
steerability
8. Azimuth
0 to 360continuous with fine
adjustments
9. Elevation
10degto 85deg
10 Polarization
Linear orthogonal
11 Mount option
Ground mounting assembly tobe
provided.
Mount should bepowder coated/
hot dipgalvanized.
12 Reflector
Glass fiber reinforced polyester
Material
13 Wind loading 80 Km/h operational, 200 Km/h
survival
14 Feed VSWR
better than 1.3: 1
15 Ports
2 port, for receiving both linear and
Orthogonal polarization signals
16 Polarization
30dB ( min ) onaxis
discrimination
17 Polarization
-5degreeto 95degree
Adjustment
3. Specification for theDigital LNBC inKu band
S. No. Parameter
Specification
a) Input frequency
10.7 GHz to 12.2 GHz (See note given
range
below)
b) Local Oscillator
LO freq of LNBC should be capable to
frequency
provide output frequency in L Band
between 950to 2150 MHz.
DG:DD/TxD/10kW /2012/EV /
Page 65 of 68
c) L.a. Stability
25KHz or better
L.a. Phasenoise
Better than 75dBc/Hz @ 1kHz
d)
Conversion gain
55dB (min)
e) Output level at 5 dBm (min)
IdB compressIOn
point
f)
Output Connector
F typefemale
g) Input
Better than 2.3: I
VSWR/Output
VSWR
h) Noise Figure I dB (Max)
i) Power supply
Should work between + 15V to +24V
requirement
with current consumption of about 300
mA (max)
j) Input flange
WR 75
k)
LNBC should be environmentally sealed against weather
conditions and extremes of temperature (as mentioned
in
Table 3) LNBC shouldalso be 100%water proof.
NOTE: Bidder may offer 2LNBCs or 3LNBCs in oneset (1No. for
eachband) tocover entire frequency ranf!e.
DG:DD/TxD/lOkW /2012/EV /
Page 66 of 68
Annexure 11-10
Specification for RFPower Meter with Sensors
SCOPE:
The RF power meter is required for measurement of RF power of modulated
signal. It should beasensor based power measurement device having agood dynamic
range. The equipment should be rugged in construction, light weight and easy to
operate. The equipment must be supplied with the accessories like power cord, fuses
andmanuals.
Technical Specifications:
Temperature As perTable3
S.No.
1.
2.
3.
3.
4.
5.
6.
7.
Temperature
Values
Avera e ower
-67dBmto+44dBm
s er second
The RF Power meter must be supplied with the power sensors to measure the
power intheabovespecified range.
DG:DD/TxD/10kW /2012/EV /
Page 67 of 68
Annexure III
Indicative Sketch for 10kW (1+1) Transmitter Systemat onelocation
~
' lullinl
: ~ ~)-{)lVfA-2
, fem,1lD
,
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~
: Setal Input Equipment : : :
(~/',~: --- :: :
'J -,:) IVfA-t Ll}-O ___' : 10kWU HFTVTx1 :
. I '- . ~ ""\ r~' :
VIlA and . . . , . r- - \ . - - I I
Do: AIlA: 1F~5W
111
k}{}IN' ::,: _~////:t~~.:,:
-(.)~)-- ~.....
...... from .... . \ ()! VDAand I
' qus IIlD5 -(H) ~ J" AIlA -0-(' ' : '
-0-0, 1OkWU HFTVTx2,
, Video tEstqus:~ :). '
: -t,~'"" ,I : , .. '
! ': ~
; .1. . L... . .' _ ~
, IFfromTx ---I ~ 1 1V ~ ToVideoPilll:h~
ill.Part
___ ~ ToAuclioPilll:hhnel
,
, - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ . - - - - - - - - - - - - - - - - , - - - - - - - - - - - - - - -
Fran
/luJ o/
Vi d e o
Pab:h
Panel
{HJ I WfM
.. UD~t2
-{)-(l- lIoi!;)fwlnput-
0u1put
MlIniIDffIIilI
N : L ADiDpol md
_ it- g eqoipa.mt 3R: to
be winld.in 19'" Rac:k.. 1V
Ra:c:ivas 3R: DOt to be
iasbD.c:d.in Rac:k..
2.AcbWIDctailc:d Sigut
Flow Diagma. of the system
offaallllll5t beindodc:d .in
theTc:dmial bid.
DG:DD/TxD/l0kW /2012/EV / Page 68 of 68