Você está na página 1de 47

DESAIN PERHITUNGAN GUIDE WAY BEAM APMS BANDARA

SOEKARNO - HATTA


PT. ADHI KARYA (PERSERO) tbk
Jl. Raya Pasar Minggu KM.18
Jakarta Selatan 12950 Indonesia
Phone: +62 21 797 5312; Fax: 797 5311










PROYEK : APMS BANDARA INTERNASIONAL SOEKARNO-
HATTA
PEMILIK :

LOKASI : BANDARA INTERNASIONAL SOEKARNO - HATTA

NO. DOKUMEN : 02

NO. PEKERJAAN :










REV.NO DATE DESCRIPTION PREPD CHKD APPD







0 13/05/2014 Issued for Information


PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 2 of 47

LEMBAR KONTROL

NO. REV TANGGAL DESKRIPSI
0 13/05/2014 Issued for Information































PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 3 of 47

Daftar Isi

1.1 Analisa dan Desain Guide Way Beam ..4
1.2 Material.. ...4
1.3 Span Girder ...6
1.4 Continious Girder24
1.5 Daerah Pengangkuran 37
1.6 Desain Tulangan Tarik dan Tekan ..40










































PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 4 of 47



1.0 Analisa dan Desain Guide Way Beam
1.1 Material

c
2.4
ton
m
3
: = unit weight of concrete
f'
c
50MPa : = f'
c
50MPa = 28-day strength
f'
ci
0.9f'
c
: = f'
ci
45MPa = i ni ti al strength at transfer
(assumed)
E
c
4700 f'
c
MPa : = E
c
33234.019MPa = Gi rder final elastic modul us
f
y
400MPa : =
E
ci
4700 f'
ci
MPa : = E
ci
31528.558MPa = Gi rder el asti c modul us at transfer
Allowable Stress in Girder : (SNI 2847 2002)
fci 0.6 f'
ci
: = fci 27 MPa =
fti 0.25 f'
ci
MPa : = fti 1.68MPa = (regi on other then support)
ftip 0.5 f'
ci
MPa : = ftip 3.35MPa = (support regi on)
fc 0.6 f'
c
: = fc 30 MPa = (due to prestress + total l oad)
ft 0.5 f'
c
MPa : = ft 3.54MPa = (tension stress l i mit)
fci_se rv 0.45 f'
ci
: = fci_se rv 20.25 MPa = without ea rthqua ke ( )
fc_serv 0.45 f'
c
: = fc_serv 22.5 MPa = without ea rthqua ke ( )



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 5 of 47

2.2) Prestressing Tendon (Low Relaxation)
f
pu
1860MPa : =
f
py
0.9f
pu
: = f
py
1674MPa =
f
pj
0.75f
pu
: = f
pj
1395MPa =
f
pi
0.92f
pj
: = f
pi
1283.4MPa =
fpeff_simple 0.88f
pi
: = fpeff_simple 1129.392MPa = (total l osses j -e= 20% )
E
ps
195000MPa : =
Strand_diameter 12.7mm : = pr EN 10138-3 (C range/Freyssinet)
Aps1 98.7mm
2
: = Strand area

3) Cross Section of Girder
Reduction factor for bendi ng : |
b
0.8 : =
L 19m : = beam length
x 0m 0.66666666667 m , L .. : =
a1 x ( ) 1.8m : =
a
sp
a1 0 ( ) : = a
sp
1.8m = at support
a
mid
a1 15 ( ) : = a
mid
1.8m = at middl e
b 800mm : =

A x ( ) b a1 x ( ) : = Gross area of section
A
sp
A 0 ( ) : = A
sp
1.44m
2
=
A
mid
A 10 ( ) : = A
mid
1.44m
2
=
neutral axis to beam top
y
t
x ( )
a1 x ( )
2
: =
y
sp
y
t
0 ( ) : = y
sp
900mm = neutral axis at support
y
mid
y
t
10 ( ) : = y
mid
900mm = neutral axis at mi ddl e
y
b
x ( ) a1 x ( ) y
t
x ( ) : = neutral axis to beam bottom
I x ( )
1
12
b a1 x ( )
3
: = Moment of i nerti a



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 6 of 47

A x ( )
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
...
m
2
=
A x ( )
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
1.44
...
m
2
= y
t
x ( )
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
...
m
= y
b
x ( )
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
...
m
= I x ( )
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
0.39
...
m
4
=
S
t
x ( )
I x ( )
y
t
x ( )
: = S
tmid
S
t
10 ( ) : =
Secti onModulus (top)
S
b
x ( )
I x ( )
y
b
x ( )
: = S
bm id
S
b
10 ( ) : = Secti on Modul us (bottom)
r x ( )
I x ( )
A x ( )
: = Radius of gi ration
kb x ( )
r x ( )
2
y
t
x ( )
: = Lower boundary of kern area
kt x ( )
r x ( )
2
y
b
x ( )
: = Upper boundary of kern area




1.2 Span Girder
4) Calculation of Internal Force
L
Dead Load
w
be am
a1 0 ( ) b
c
: = w
be am
3.46
ton
m
= Beam wei ght per uni t l ength
M
DL
x ( ) w
be am
L
2
x w
be am
x ( )
2
2
: = M
DL
L
2
|

\
|
|
.
155.95ton m =
M
uDL
x ( ) 1.4 M
DL
x ( ) : =
MDLma x M
DL
L
2
|

\
|
|
.
: = MDLma x 155.95ton m = maxi mum service moment
MuDLm ax M
uDL
L
2
|

\
|
|
.
: = MuDLm ax 218.33ton m = maxi mum ul timate moment



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 7 of 47

5) Estimate number of Required Strands
Final stress i n bottom (no prestress)
(The moment at mi d-point)
fa
MDLma x
S
bm id
: = fa 3.54MPa =
Requi red stress from prestress f_re qd fa ft : = f_re qd 0 MPa =
Estimated based on stress condi tion in bottom fi ber ft 3.54MPa =
Peff 1 ton : = e
mid
700mm : =
Given
Peff
A
mid

Peffe
mid

S
bm id

MDLma x
S
bm id
+ ft =
Pf1 Find Peff ( ) : = Pf1 0.2ton =
Estimated based on ulti mate strength of the secti on
fpe ff_simple 1129.39MPa = total l osses 20%
h H
16
: = h 1.8m =
| Aps 0.95 fpu 0.9h MuDL
ma x
> |
b
0.8 =
Aps_sim ple
MuDLm ax
|
b
0.9 y
mid
e
mid
+
( )

0.9f
pu

: = Aps_sim ple 1110mm


2
=
Pf2 Aps_sim plefpe ff_simple : =
Pf2 127.87ton =
Effecti ve prestressing force
Pf ma x Pf1 Pf2 ( ) ( ) : = Pf 127.87ton =
Aps_sim ple
Pf
fpe ff_simple
: =
Aps_sim ple 1110mm
2
=

5) Estimate number of Required Strands
Final stress i n bottom (no prestress)
(The moment at mi d-point)
fa
MDLma x
S
bm id
: = fa 3.54MPa =
Requi red stress from prestress f_re qd fa ft : = f_re qd 0 MPa =
Estimated based on stress condi tion in bottom fi ber ft 3.54MPa =
Peff 1 ton : = e
mid
700mm : =
Given
Peff
A
mid

Peffe
mid

S
bm id

MDLma x
S
bm id
+ ft =
Pf1 Find Peff ( ) : = Pf1 0.2ton =
Estimated based on ulti mate strength of the secti on
fpe ff_simple 1129.39MPa = total l osses 20%
h H
16
: = h 1.8m =
| Aps 0.95 fpu 0.9h MuDL
ma x
> |
b
0.8 =
Aps_sim ple
MuDLm ax
|
b
0.9 y
mid
e
mid
+
( )

0.9f
pu

: = Aps_sim ple 1110mm


2
=
Pf2 Aps_sim plefpe ff_simple : =
Pf2 127.87ton =
Effecti ve prestressing force
Pf ma x Pf1 Pf2 ( ) ( ) : = Pf 127.87ton =
Aps_sim ple
Pf
fpe ff_simple
: =
Aps_sim ple 1110mm
2
=



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 8 of 47

Determi ne the number of strands used
n
strand_simple
Aps_sim ple
Aps1
|

\
|
|
.
: = n
strand_simple
11.25 =
Number of Strands n
strand_simple
14 : = 2 x 7 strand D12.7
Total area of stress Aps_sim ple n
strand_simple
Aps1 : = Aps_sim ple 1381.8mm
2
=
Prestressi ng Forces Pi f
pi
Aps_sim ple : = Pi 180.837ton =
Jacki ng Forces Pj f
pj
Aps_sim ple : = Pj 196.562ton =
Loss factor R 1 0.2 : = R 0.8 =
(l osses = 20%)







PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 9 of 47




0 5 10 15 20
0
500
1 10
3

1.5 10
3

Strand
x_1
0 5 10 15 20
0
200
400
600
800
Strand Pattern
Distance
E
c
c
e
n
t
r
i
c
i
t
y



0 5 10 15 20
0
500
1 10
3

1.5 10
3

Strand
x_1
0 5 10 15 20
0
200
400
600
800
Strand Pattern
Distance
E
c
c
e
n
t
r
i
c
i
t
y




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 10 of 47

6) Prestress Losses
The total l oses shal l be the sum of elastis shortening (ES) + shrinkage (SR) + Creep (CR) + Rel axati on (R2)
6a) Elastic Shortening
If post-tensi on i s used for prestressi ng system, then el asti c shortening is not considered. It' s consi dered i f
gradually stressing cable is needed.
Assumed that for calcul ation el asti c shorteni ng post-tension system, eccentricity cable i s regarded as a group.
Not separatel y cal culated for each cabl e.
number of cable, n
ca ble
2 : = 1 cabl e = 10 strands Aps_sim ple 1381.8mm
2
=
P
j ac king
75% f
pu
Aps_sim ple : = P
j ac king
196.56ton =
f
j ac king
P
j ac king
Aps_sim ple
: = f
j ac king
1395MPa =
concrete stress at prestress l evel
f
cgp
Pi
A
mid

Pi e
mid
2

I 15 ( )

MDLma xe
mid

I 15 ( )
+
|

\
|
|
|
.
E
ps
E
c
: = f
cgp
4.18 MPa = comp ( )
f
cgp
f
cgp
: =
Cable - 1 :
f
p1
n
ca ble
1 ( ) f
cgp
: = f
p1
4.18MPa =
Cable - 2 :
f
p2
n
ca ble
2 ( ) f
cgp
: = f
p2
0 MPa =


Average losses due to gradually stressing cable :
f
p_ave rage
1
n
ca ble
i
i 1 ( ) f
cgp

(

=
n
ca ble
: = f
p_ave rage
2.09MPa =
Loss stress for el asti c shorteni ng, Afp
ES_post
f
p_ave rage
: = Afp
ES_post
2.09MPa =
Initial stress after elastic shortening , fpi
1
f
j ac king
Afp
ES_post
: = fpi
1
1392.91MPa =
% Ini ti al losses after elastic shortening :
Afp
ES_post
f
j ac king
0.15% =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 11 of 47

Initial stress after elastic shortening , fpi
1
f
jacking
Afp
ES_post
: = fpi
1
1392.91MPa =
% Initi al l osses after el asti c shortening :
Afp
ES_post
f
jacking
0.15% =
So, l oss after el asti c shorteni ng i s; Afp
ES_post
2.09MPa =
because of gradual ly prestressi ng i s needed and post tensi on Afp
ES
Afp
ES_post
: =
Initial stress after elastic shortening ; fpi
1
f
jacking
Afp
ES
: = fpi
1
1392.91MPa =
% Initi al stresses after el asti c shortening :
fpi
1
f
jacking
99.85% =


6.1.2. Friction
Fricti on Coeffi ci ent, 0.25 : = (for grouting tendon in metal sheating, 7 wire strand)
Wobbl e Coeffi ci ent, k 0.0032m
1
: = (for grouting tendon in metal sheating, 7 wire strand)
Strand
0 0 ,
900 = strand positi on at support
Strand
15 0 ,
1598.25 = strand positi on at mid poi nt
y Strand
15 0 ,
Strand
0 0 ,

|
\
|
.
mm : = y 698.25mm = L 19m =
o
8 y
L
: = o 0.29 =
fpi after el asti c shorteni ng and fri ction lossess
fpi
2
fpi
1
e
o k
L
2
+
|

\
|
|
.

: = fpi
2
1255.45MPa =
Jacki ng from both side so that L'
= L/2
Afpi
friction
fpi
1
fpi
2
: = Afpi
friction
137.46MPa =
% Ini ti al stresses after fri cti on :
fpi
2
f
j ac king
90% = AT OTHER SUPPORT / ANCHORAGE /
not the end of tendon / x = L





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 12 of 47

6.1.2. Friction
Fricti on Coeffi ci ent, 0.25 : = (for grouting tendon in metal sheating, 7 wire strand)
Wobbl e Coeffi ci ent, k 0.0032m
1
: = (for grouting tendon in metal sheating, 7 wire strand)
Strand
0 0 ,
900 = strand positi on at support
Strand
15 0 ,
1598.25 = strand positi on at mid poi nt
y Strand
15 0 ,
Strand
0 0 ,

|
\
|
.
mm : = y 698.25mm = L 19m =
o
8 y
L
: = o 0.29 =
fpi after el asti c shorteni ng and fri ction lossess
fpi
2
fpi
1
e
o k
L
2
+
|

\
|
|
.

: = fpi
2
1255.45MPa =
Jacki ng from both side so that L'
= L/2
Afpi
friction
fpi
1
fpi
2
: = Afpi
friction
137.46MPa =
% Ini ti al stresses after fri cti on :
fpi
2
f
j ac king
90% = AT OTHER SUPPORT / ANCHORAGE /
not the end of tendon / x = L


fpi_m id fpi
1
Afpi
friction
: = fpi_m id 1255.45MPa =
P
mid
fpi_m idAps_sim ple : = P
mid
176.9ton = Gaya pada tendon di tengah bentang
setelah pengaruh friksi
6.1.3. Anchorage Set
Delta
set
6mm : =
P
average
P
j ac king
P
mid
+
2
: = P
average
186.73ton =
The expected elongation due to the stressi ng operation:
Jacki ng from one si de
de lta
P
average
L
Aps_sim pleE
ps

: = de lta 129.12mm =
The expected anchorage set due to the stressing operati on:
assumed that the ful l of span tendon, the fri cti on l oss per meter i s:
p
P
j ac king
P
mid

L
: = p 1.03
ton
m
=
The l ength of tendon affected by anchorage set is gi ven:
L
set
Delta
set
Aps_sim ple E
ps

p
: = L
set
12.62m = > 15m
A
P
2 p L
set
: = A
P
26.12ton =
Hence after anchori ng, the force at the end of the tendon side of jacking is:
P
i
f
pi
Aps_sim ple : = P
i
180.84ton =
Pi
anchorage
P
i
A
P
: = Pi
anchorage
154.71ton =


Initial stress after anchorage set ; fpi
anchorage
Pi
anchorage
Aps_sim ple
: = fpi
anchorage
1098MPa =
% Ini ti al stresses after anchorage :
fpi
anchorage
f
j ac king
78.71% = Afp
anchorage
A
P
Aps_sim ple
: =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 13 of 47

check : %fpi
f
j ac king
Afp
ES
Afp
anchorage

f
pu
: = %fpi 64.92% = < 74%fpu OK
losses due to friction at midspan tendon (x = 10m) is
A
P_mid
0kN L
set
L
2
s if
2 p L
set
L
2

\
|
|
.

(
(

othe rwise
: = A
P_mid
6.46ton =
fp
anchorage _mid
A
P_mid
Aps_simple
: = fp
anchorage _mid
45.85MPa =
losses due to friction at support tendon (x = 0m) is
Jacki ng dari satu arah:
Af
PA
Delta
set
L
E
ps
: = Af
PA
61.58MPa =
APA Af
PA
Aps_simple : = APA 8.68ton =
6.2. Long Term
6.2.1. Relaxation Loss
s2 "Post tension" : = s1 "Low relaxation" : =
Losses j acking - transfer : fpi 0.70.92 f
pu
: = fpi 1197.84MPa = Check
Mi dspan
t
1
1 : = t
2
18 : = t dimension is hour


Afp
relaxation
fpi
log t
2
( )
log t
1
( )

10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Pre-tension" = . if


fpi
log t
2
( )
10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Post-tension" = . if


fpi
log t
2
( )
log t
1
( )

45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Low relaxation tendon" = s2 "Pre-tension" = . if


fpi
log t
2
( )
45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

othe rwise
: =
Afp
relaxation
Afp
relaxation
Afp
relaxation
0MPa > if
0MPa ( ) othe rwise
: = Afp
relaxation
5.53MPa =
Afp
relaxation_transfer
Afp
relaxation
: =
fp
transfe r
fpi Afp
relaxation_transfer
: = fp
transfe r
1192.31MPa =
Losses transfer - 30 days :
t
3
t
2
: = t
4
720 : = t dimension is hour fpi fp
transfe r
: =
Afp
relaxation
fpi
log t
4
( )
log t
3
( )

10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Pre-tension" = . if


fpi
log t
4
( )
10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Post-tension" = . if


fpi
log t
4
( )
log t
3
( )

45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Low relaxation tendon" = s2 "Pre-tension" = . if


fpi
log t
4
( )
45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

othe rwise
: =





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 14 of 47

Afp
relaxation
fpi
log t
2
( )
log t
1
( )

10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Pre-tension" = . if


fpi
log t
2
( )
10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Post-tension" = . if


fpi
log t
2
( )
log t
1
( )

45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Low relaxation tendon" = s2 "Pre-tension" = . if


fpi
log t
2
( )
45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

othe rwise
: =
Afp
relaxation
Afp
relaxation
Afp
relaxation
0MPa > if
0MPa ( ) othe rwise
: = Afp
relaxation
5.53MPa =
Afp
relaxation_transfer
Afp
relaxation
: =
fp
transfe r
fpi Afp
relaxation_transfer
: = fp
transfe r
1192.31MPa =
Losses transfer - 30 days :
t
3
t
2
: = t
4
720 : = t dimension is hour fpi fp
transfe r
: =
Afp
relaxation
fpi
log t
4
( )
log t
3
( )

10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Pre-tension" = . if


fpi
log t
4
( )
10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Post-tension" = . if


fpi
log t
4
( )
log t
3
( )

45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Low relaxation tendon" = s2 "Pre-tension" = . if


fpi
log t
4
( )
45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

othe rwise
: =



Afp
relaxation
Afp
relaxation
Afp
relaxation
0MPa > if
0MPa ( ) othe rwise
: =
Afp
relaxation30day s
Afp
relaxation
: =
fp
30day s
fpi Afp
relaxation30day s
: = fp
30day s
1180.02MPa = < 0.8 f
pu
1488MPa =
Losses transfer - 2 years :
fpi fp
30day s
: =
t
5
t
4
: = t
6
24365 2 : = t dimension is hour
Afp
relaxation
fpi
log t
6
( )
log t
5
( )

10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Pre-tension" = . if


fpi
log t
6
( )
10
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Stress relieved tendon" = s2 "Post-tension" = . if


fpi
log t
6
( )
log t
5
( )

45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

s1 "Low relaxation tendon" = s2 "Pre-tension" = . if


fpi
log t
6
( )
45
|

\
|
|
.

fpi
f
py
0.55
|

\
|
|
.

(
(

othe rwise
: =
Afp
relaxation
Afp
relaxation
Afp
relaxation
0MPa > if
0MPa ( ) othe rwise
: =
Afp
relaxation_2ye ars
Afp
relaxation
: =
fp
2y ea rs
fpi Afp
relaxation_2ye ars
: = fp
2y ea rs
1162.79MPa =
fpi 0.7f
pu
: = fpi 1302MPa =
% Ini ti al stresses after rel axati on :
fp
2y ea rs
fpi
89.31% =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 15 of 47

6.2.2. Creep Loss
ul timate Creep coeff
t
CR
30 7 : = k
CR
2.35
t
CR
0.6
10 t
CR
0.6
+
|

\
|
|
|
|
.
: = Cu 2.35 : =
t dimension is day
k
CR
2 s2 "Pre-tension" = k
CR
2 < . if
1.6 s2 "Post-tension" = k
CR
1.6 < . if
k
CR
othe rwise
: = k
CR
0.93 =
fpi fpi fp
anchorage _mid

( )
L
set
L
2
> if
fpi othe rwise
: = fp
anchorage _mid
45.85MPa =
fpi 1256.15MPa = Pi Aps_simplefpi : = Pi 177ton =
f
cp
Pi
A
mid

Pi e
mid

S
bmid

MDLma x
S
bmid
+
|

\
|
|
.
E
ps
E
c
: = f
cp
2.8 MPa =
Af
CR
k
CR
f
cp
: =
Afp
CR
Af
CR
Af
CR
0MPa > if
0MPa ( ) othe rwise
: = Afp
CR
2.61MPa =
Total Loss of creep,

Afp
CR
fpi
0.21% =
% Ini ti al stresses after creep : 1
Afp
CR
fpi
99.79% =


6.2.3. Shrinkage Loss
s3 "moist curing" : =
t
SH
30 7 : = t dimension is day
strai n ul timate, c
su
80010
6

|
\
|
.
s3 "moist curing" = if
73010
6

|
\
|
.
othe rwise
: =
Afp
SH
c
su
t
SH
35 t
SH
+
|

\
|
|
.
E
ps
: = Afp
SH
61.86MPa =
% Ini ti al stresses after shri nkage : 1
Afp
SH
fpi
95.08% = Total Loss of Shri nkage,
Afp
SH
fpi
4.92% =






PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 16 of 47

RESUME :
Total loss due to immediate loss :
f
j ac king
1395MPa = fpi 0.70.92 f
pu
: = fpi 1197.84MPa =
Afp
ES
2.09MPa =
Afpi
friction
137.46MPa =
Afp
anchorage
185.4MPa =
Afp
relaxation_transfer
5.53MPa =
Total Initial Losses : Afi Afp
relaxation_transfer
Afp
ES
+ Afp
anchorage
+ Afpi
friction
+ : =
Afi 330.48MPa =
after first relaxation fpi f
j ac king
Afi : = fpi 1064.52MPa =
Pi 177ton = 1
Pi
P
j ac king
9.95% =
fpi
f
pu
57.23% = < 70% OK !


Total loss due to time dependent :
Afp
relaxation_2ye ars
17.24MPa =
Afp
CR
2.61MPa =
Afpi
friction
fpi
0.13 =
Afp
SH
61.86MPa =
fpi 1064.52MPa =
Total Final Losses :
Afe Afp
relaxation_2ye ars
Afp
CR
+ Afp
SH
+ : = Afe 81.71MPa = Afe
f
pi
0.06 =
fpe fpi Afe : = fpe 982.81MPa =


Total i ni tial stress i n the strands wi th initi al l osses Pi Aps_simple fpi : = Pi 150ton =
Total fi nal stress i n the strands wi th fi nal losses Peff Aps_simple fpe : = Peff 138.48ton =
Afp Afi Afe + : = Afp 412.19MPa =
R 1
Afp
f
jacking
: = R 70.45% =
ns 0 30 .. : =
1 R 0.3 =





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 17 of 47

Design Variables
Number of strands 14 D12.4 n
strand_simple
14 =
Strand area at any secti on Aps_sim ple n
strand_simple
Aps1 : = Aps_sim ple 1381.8mm
2
=
Ini ti al Strand force Fi
ns
Aps_sim plefpi : = fpi 1064.52MPa =
Final Strand force Ff
ns
Aps_sim plefpe : =
Stress at Initial Conditions
Thi s incl udes the beam wei ght and the prestress force onl y.
mp 14 : =
Ini ti al stress i n top top_i
mp
2.2 MPa =
Ini ti al stress i n bottom
bot_i
ns
Fi
ns
Ax
ns

Fi
ns
ec c1
ns
mm
Sb
ns

MDL
ns
Sb
ns
+ : = bot_i
mp
0.16MPa =
Pass fai l conditi on check_i
ns 0 ,
x_1
ns
: =
check_i
ns 3 ,
"top fail" top_i
ns
0 > top_i
ns
fti > . if
"top fail" top_i
ns
0 < top_i
ns
fci < . if
"top OK" othe rwise
othe rwise
: =
check_i
ns 6 ,
"bot fail" bot_i
ns
0 < bot_i
ns
fci < . if
"bot fail" bot_i
ns
0 > bot_i
ns
fti > . if
"bot OK" othe rwise
othe rwise
: =
check_i
ns 1 ,
top_i
ns
MPa
: = check_i
ns 4 ,
bot_i
ns
MPa
: =
check_i
ns 2 ,
fti
MPa
top_i
ns
0MPa > if
fci
MPa
othe rwise
: = check_i
ns 5 ,
fti
MPa
top_i
ns
0MPa < if
fci
MPa
othe rwise
: =
top_i
ns
Fi
ns
Ax
ns

Fi
ns
ec c1
ns
mm
St
ns
+
MDL
ns
St
ns
: =



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 18 of 47

0 5 10 15 20
30
20
10
0
10
Initial Stress
top_stre ss
ns
fti
bot_stre ss
ns
fci
x_1
ns

Positive moment envelope at Service
Assume : MSDL
ns
0% MDL
ns
: =
Final stress top SI_pt
ns
Ff
ns
Ax
ns

Ff
ns
ec c1
ns
mm
St
ns
+
MDL
ns
St
ns

MSDL
ns
ton m
St
ns
: =
Final stress i n bottom SI_pb
ns
Ff
ns
Ax
ns

Ff
ns
ec c1
ns
mm
Sb
ns

MDL
ns
Sb
ns
+
MSDL
ns
ton m
Sb
ns
+ : =
Pass fai l conditi on
check_1
ns 0 ,
x_1
ns
: =
check_1
ns 3 ,
"top fail see SIII" SI_pt
ns
0 > |
\
|
.
SI_pt
ns
ft > . if
"top fail" SI_pt
ns
0 < SI_pt
ns
fc_serv < . if
"top OK" othe rwise
othe rwise
: =
check_1
ns 6 ,
"bot fail see SIII" SI_pb
ns
0 < |
\
|
.
SI_pt
ns
fc_serv < . if
"bot fail" SI_pb
ns
0 > SI_pb
ns
ft > . if
"bot OK" othe rwise
othe rwise
: =
check_1
ns 1 ,
SI_pt
ns
MPa
: = check_1
ns 4 ,
SI_pb
ns
MPa
: =
ft
ft
MPa
: = fc
fc_serv
MPa
: =
check_1
ns 2 ,
ft SI_pt
ns
0 > if
fc othe rwise
: = check_1
ns 5 ,
ft SI_pb
ns
0 > if
fc othe rwise
: =



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 19 of 47

0 5 10 15 20
30
20
10
0
10
Final Stress
top_stress
ns
ft
bot_stress
ns
fc
x_1
ns




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 20 of 47

Flexural Strength - LRFD 5.7.3.1.1 stress in prestressing tendons
Non-prestressing bars :
fy 400MPa : = d' 50 13 + ( )mm : = d
b
25mm : = d
ns
H
ns
d' 0.5d
b
: = d
mp
1.72m =
dp
ns
Strand
ns
mm : = dp
mp
1.59m =
|
1
0.85 f'
c
30MPa s if
0.65 f'
c
55MPa > if
0.85
0.05
7MPa
f'
c
30MPa ( )

(
(

30MPa f'
c
< 55MPa s if
: =
|
1
0.71 =
f'
c
50MPa =
As1 0.25t d
b
2
: =
nt 10 : = Ast
ns
nt As1 : = tension ( )
nc 8 : = Asc
ns
nc As1 : = negl eted
comp.bars i n
calcul ation
t
ns
Ast
ns
b d
ns

: = t
mp
0.00356 =
c
ns
Asc
ns
b d'
: = c
mp
0.08 =
et
ns
t
ns
fy
f'
c
: = et
mp
0.03 =
ec
ns
c
ns
fy
f'
c
: = ec
mp
0.62 =


Prestressing tendons :
b 0.8m =
p 0.28 : = Low Rel axati on strand
Aps_sim ple 1381.8mm
2
=
p
ns
Aps_sim ple
b dp
ns

: =
f
pu
1860MPa = f'
c
50MPa =
fps
ns
f
pu
1
p
|
1
p
ns
f
pu
f'
c

d
ns
dp
ns
et
ns
ec
ns

( )
+

(
(
(

(
(
(

: =
Width of concrete stress is determined below :
Tps
ns
fps
ns
Aps_sim ple Ast
ns
f
y
+ : =
To ensure that the bar will be yield, so code restricts :
ep
ns
p
ns
fps
ns
f'
c
: =
check_yield
ns
"yield" ep
ns
d
ns
dp
ns
et
ns
ec
ns

( )
+ 0.36|
1
s if
"not yield" othe rwise
: =
Depth of compressive stress block :
a
ns
Aps_sim plefps
ns
Ast
ns
fy +
0.85f'
c
|
1
b
: =
Aps_sim ple 1381.8mm
2
=
Flexural Strength : | 0.8 : =
|Mn
ns
| Aps_sim plefps
ns
dp
ns
a
ns
2

\
|
|
.
Ast
ns
fy d
ns
a
ns
2

\
|
|
.
+

(
(

: =
Check pass or fail condi ti on check_m
ns
"OK" |Mn
ns
MuDL
ns
> if
"FAIL" othe rwise
: =
Prepare for output di spl ay
disp_m
ns 0 ,
x_1
ns
: = disp_m
ns 3 ,
check_yield
ns
: = disp_m
ns 6 ,
check_m
ns
: =
disp_m
ns 1 ,
Aps_sim ple
mm
2
: =
disp_m
ns 4 ,
MuDL
ns
ton m
: =
disp_m
ns 2 ,
dp
ns
mm
: = disp_m
ns 5 ,
|Mn
ns
ton m
: =





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 21 of 47

Prestressing tendons :
b 0.8m =
p 0.28 : = Low Rel axati on strand
Aps_sim ple 1381.8mm
2
=
p
ns
Aps_sim ple
b dp
ns

: =
f
pu
1860MPa = f'
c
50MPa =
fps
ns
f
pu
1
p
|
1
p
ns
f
pu
f'
c

d
ns
dp
ns
et
ns
ec
ns

( )
+

(
(
(

(
(
(

: =
Width of concrete stress is determined below :
Tps
ns
fps
ns
Aps_sim ple Ast
ns
f
y
+ : =
To ensure that the bar will be yield, so code restricts :
ep
ns
p
ns
fps
ns
f'
c
: =
check_yield
ns
"yield" ep
ns
d
ns
dp
ns
et
ns
ec
ns

( )
+ 0.36|
1
s if
"not yield" othe rwise
: =
Depth of compressive stress block :
a
ns
Aps_sim plefps
ns
Ast
ns
fy +
0.85f'
c
|
1
b
: =
Aps_sim ple 1381.8mm
2
=
Flexural Strength : | 0.8 : =
|Mn
ns
| Aps_sim plefps
ns
dp
ns
a
ns
2

\
|
|
.
Ast
ns
fy d
ns
a
ns
2

\
|
|
.
+

(
(

: =
Check pass or fail condi ti on check_m
ns
"OK" |Mn
ns
MuDL
ns
> if
"FAIL" othe rwise
: =
Prepare for output di spl ay
disp_m
ns 0 ,
x_1
ns
: = disp_m
ns 3 ,
check_yield
ns
: = disp_m
ns 6 ,
check_m
ns
: =
disp_m
ns 1 ,
Aps_sim ple
mm
2
: =
disp_m
ns 4 ,
MuDL
ns
ton m
: =
disp_m
ns 2 ,
dp
ns
mm
: = disp_m
ns 5 ,
|Mn
ns
ton m
: =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 22 of 47

Ultimate Moment Capacity Output
column 0 = span point
column 1 = Aps
column 2 = dp
column 3 = yield or not
column 4 = Applied moment
column 5 = Capacity |Mn
column 6 = pass or f ail

disp_m
0 1 2 3 4 5 6
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
0 1381.8 900 "yield" 0 491.15 "OK"
0.63 1381.8 985.86 "yield" 29.58 510.95 "OK"
1.27 1381.8 1066.1 "yield" 56.85 529.16 "OK"
1.9 1381.8 1140.73 "yield" 82.25 545.91 "OK"
2.53 1381.8 1209.74 "yield" 105.38 561.27 "OK"
3.17 1381.8 1273.14 "yield" 126.24 575.29 "OK"
3.8 1381.8 1330.92 "yield" 145.15 588.01 "OK"
4.43 1381.8 1383.09 "yield" 161.83 599.44 "OK"
5.07 1381.8 1429.64 "yield" 176.27 609.61 "OK"
5.7 1381.8 1470.57 "yield" 188.7 618.53 "OK"
6.33 1381.8 1505.89 "yield" 198.92 626.21 "OK"
6.97 1381.8 1535.59 "yield" 206.94 632.65 "OK"
7.6 1381.8 1559.68 "yield" 212.89 637.88 "OK"
8.23 1381.8 1578.15 "yield" 216.65 641.88 "OK"
8.87 1381.8 1591.01 "yield" 218.26 644.66 "OK"
9.5 1381.8 1598.25 "yield" 217.73 646.23 "OK"
10.13 1381.8 1591.01 "yield" 215.04 644.66 "OK"
10.77 1381.8 1578.15 "yield" 210.23 641.88 "OK"
11.4 1381.8 1559.68 "yield" 203.21 637.88 "OK"
12.03 1381.8 1535.59 "yield" 194.07 632.65 "OK"
12.67 1381.8 1505.89 "yield" 182.85 626.21 "OK"
13.3 1381.8 1470.57 "yield" 169.34 618.53 "OK"
13.93 1381.8 1429.64 "yield" 153.75 609.61 "OK"
14.57 1381.8 1383.09 "yield" 136.11 599.44 "OK"
15.2 1381.8 1330.92 "yield" 116.12 588.01 "OK"
15.83 1381.8 1273.14 "yield" 94.07 575.29 "OK"
16.47 1381.8 1209.74 "yield" 70.01 561.27 "OK"
17.1 1381.8 1140.73 "yield" 43.55 545.91 "OK"
17.73 1381.8 1066.1 "yield" 15.04 529.16 "OK"
18.37 1381.8 985.86 "yield"
-13
-1.33 10 510.95 "OK"
19 1381.8 900 "yield" 43.55 491.15 "OK"
=
CHECK CRACK AT SERVICE LOADS






PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 23 of 47

disp_m
0 1 2 3 4 5 6
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
0 1381.8 900 "yield" 0 491.15 "OK"
0.63 1381.8 985.86 "yield" 29.58 510.95 "OK"
1.27 1381.8 1066.1 "yield" 56.85 529.16 "OK"
1.9 1381.8 1140.73 "yield" 82.25 545.91 "OK"
2.53 1381.8 1209.74 "yield" 105.38 561.27 "OK"
3.17 1381.8 1273.14 "yield" 126.24 575.29 "OK"
3.8 1381.8 1330.92 "yield" 145.15 588.01 "OK"
4.43 1381.8 1383.09 "yield" 161.83 599.44 "OK"
5.07 1381.8 1429.64 "yield" 176.27 609.61 "OK"
5.7 1381.8 1470.57 "yield" 188.7 618.53 "OK"
6.33 1381.8 1505.89 "yield" 198.92 626.21 "OK"
6.97 1381.8 1535.59 "yield" 206.94 632.65 "OK"
7.6 1381.8 1559.68 "yield" 212.89 637.88 "OK"
8.23 1381.8 1578.15 "yield" 216.65 641.88 "OK"
8.87 1381.8 1591.01 "yield" 218.26 644.66 "OK"
9.5 1381.8 1598.25 "yield" 217.73 646.23 "OK"
10.13 1381.8 1591.01 "yield" 215.04 644.66 "OK"
10.77 1381.8 1578.15 "yield" 210.23 641.88 "OK"
11.4 1381.8 1559.68 "yield" 203.21 637.88 "OK"
12.03 1381.8 1535.59 "yield" 194.07 632.65 "OK"
12.67 1381.8 1505.89 "yield" 182.85 626.21 "OK"
13.3 1381.8 1470.57 "yield" 169.34 618.53 "OK"
13.93 1381.8 1429.64 "yield" 153.75 609.61 "OK"
14.57 1381.8 1383.09 "yield" 136.11 599.44 "OK"
15.2 1381.8 1330.92 "yield" 116.12 588.01 "OK"
15.83 1381.8 1273.14 "yield" 94.07 575.29 "OK"
16.47 1381.8 1209.74 "yield" 70.01 561.27 "OK"
17.1 1381.8 1140.73 "yield" 43.55 545.91 "OK"
17.73 1381.8 1066.1 "yield" 15.04 529.16 "OK"
18.37 1381.8 985.86 "yield"
-13
-1.3310 510.95 "OK"
19 1381.8 900 "yield" 43.55 491.15 "OK"
=
CHECK CRACK AT SERVICE LOADS
Modulus of rupture of concrete fr 0.7
f'
c
MPa
MPa : = fr 4.95MPa =
Peff 138.48ton =
Calculate the cracking moment, Mcr
Mc r
ns
fr Sb
ns
Peff ec c1
ns
mm
rx
ns
( )
2
kbx
ns
+

(
(
(

+ : =
ratio1
ns
|Mn
ns
Mc r
ns
: = ratio2
ns
MuDL
ns
|Mn
ns
: =
check_crac k
ns
"OK" ratio1
ns
1.2 > ratio2
ns
0.5 < v if
"FAIL" othe rwise
: =
disp_crac k
ns 0 ,
x_1
ns
: = disp_crac k
ns 1 ,
MuDL
ns
ton m
: = disp_crac k
ns 2 ,
|Mn
ns
ton m
: =
disp_crac k
ns 3 ,
ratio1
ns
: = disp_crac k
ns 4 ,
ratio2
ns
: = disp_crac k
ns 5 ,
check_crac k
ns
: =


column 0 = span point
column 1 = MuDL
column 2 = |Mn
column 3 = ratio |Mn/Mcr
column 4 = ratio MuDL/|Mn
column 5 =pass or fai l
disp_crac k
0 1 2 3 4 5
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
0 0 491.15 1.43 0 "OK"
0.63 29.58 510.95 1.44 0.06 "OK"
1.27 56.85 529.16 1.44 0.11 "OK"
1.9 82.25 545.91 1.45 0.15 "OK"
2.53 105.38 561.27 1.45 0.19 "OK"
3.17 126.24 575.29 1.46 0.22 "OK"
3.8 145.15 588.01 1.46 0.25 "OK"
4.43 161.83 599.44 1.46 0.27 "OK"
5.07 176.27 609.61 1.46 0.29 "OK"
5.7 188.7 618.53 1.46 0.31 "OK"
6.33 198.92 626.21 1.47 0.32 "OK"
6.97 206.94 632.65 1.47 0.33 "OK"
7.6 212.89 637.88 1.47 0.33 "OK"
8.23 216.65 641.88 1.47 0.34 "OK"
8.87 218.26 644.66 1.47 0.34 "OK"
9.5 217.73 646.23 1.47 0.34 "OK"
10.13 215.04 644.66 1.47 0.33 "OK"
10.77 210.23 641.88 1.47 0.33 "OK"
11.4 203.21 637.88 1.47 0.32 "OK"
12.03 194.07 632.65 1.47 0.31 "OK"
12.67 182.85 626.21 1.47 0.29 "OK"
13.3 169.34 618.53 1.46 0.27 "OK"
13.93 153.75 609.61 1.46 0.25 "OK"
14.57 136.11 599.44 1.46 0.23 "OK"
15.2 116.12 588.01 1.46 0.2 "OK"
15.83 94.07 575.29 1.46 0.16 "OK"
16.47 70.01 561.27 1.45 0.12 "OK"
17.1 43.55 545.91 1.45 0.08 "OK"
17.73 15.04 529.16 1.44 0.03 "OK"
18.37 0 510.95 1.44 0 "OK"
19 43.55 491.15 1.43 0.09 "OK"
=



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 24 of 47

column 0 = span point
column 1 = MuDL
column 2 = |Mn
column 3 = ratio |Mn/Mcr
column 4 = ratio MuDL/|Mn
column 5 =pass or fai l
disp_crac k
0 1 2 3 4 5
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
0 0 491.15 1.43 0 "OK"
0.63 29.58 510.95 1.44 0.06 "OK"
1.27 56.85 529.16 1.44 0.11 "OK"
1.9 82.25 545.91 1.45 0.15 "OK"
2.53 105.38 561.27 1.45 0.19 "OK"
3.17 126.24 575.29 1.46 0.22 "OK"
3.8 145.15 588.01 1.46 0.25 "OK"
4.43 161.83 599.44 1.46 0.27 "OK"
5.07 176.27 609.61 1.46 0.29 "OK"
5.7 188.7 618.53 1.46 0.31 "OK"
6.33 198.92 626.21 1.47 0.32 "OK"
6.97 206.94 632.65 1.47 0.33 "OK"
7.6 212.89 637.88 1.47 0.33 "OK"
8.23 216.65 641.88 1.47 0.34 "OK"
8.87 218.26 644.66 1.47 0.34 "OK"
9.5 217.73 646.23 1.47 0.34 "OK"
10.13 215.04 644.66 1.47 0.33 "OK"
10.77 210.23 641.88 1.47 0.33 "OK"
11.4 203.21 637.88 1.47 0.32 "OK"
12.03 194.07 632.65 1.47 0.31 "OK"
12.67 182.85 626.21 1.47 0.29 "OK"
13.3 169.34 618.53 1.46 0.27 "OK"
13.93 153.75 609.61 1.46 0.25 "OK"
14.57 136.11 599.44 1.46 0.23 "OK"
15.2 116.12 588.01 1.46 0.2 "OK"
15.83 94.07 575.29 1.46 0.16 "OK"
16.47 70.01 561.27 1.45 0.12 "OK"
17.1 43.55 545.91 1.45 0.08 "OK"
17.73 15.04 529.16 1.44 0.03 "OK"
18.37 0 510.95 1.44 0 "OK"
19 43.55 491.15 1.43 0.09 "OK"
=

Check Deflections
11.1. Calculate initial deflection
Chamber due to initial prestress only
Imid Ix
15
: =
Api
5 Pi e
mid
L
2

48E
ci
Imid
: = Api 3.15 mm = (upward)
Self weight deflection
Abs
5
384
w
be am
( )
L
4

E
ci
Imid
: = Abs 4.68mm = (downward)
Long term deflect ion by PCI Multipliers
A1 1.85Abs 1.8Api + : = A1 2.98mm = (downward)
Allowable deflection
L
2500
7.6mm = OK !
So, the total of longterm deflection :
A2 2.45Api 2.7 Abs + : = A2 4.91mm = (downward)
So, total deflection
Atot A2 A1 : = Atot 1.93mm = (downward )
L
2500
7.6mm = OK !
Allowable deflection



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 25 of 47

Check Deflections
11.1. Calculate initial deflection
Chamber due to initial prestress only
Imid Ix
15
: =
Api
5 Pi e
mid
L
2

48E
ci
Imid
: = Api 3.15 mm = (upward)
Self weight deflection
Abs
5
384
w
be am
( )
L
4

E
ci
Imid
: = Abs 4.68mm = (downward)
Long term deflect ion by PCI Multipliers
A1 1.85Abs 1.8Api + : = A1 2.98mm = (downward)
Allowable deflection
L
2500
7.6mm = OK !
So, the total of longterm deflection :
A2 2.45Api 2.7 Abs + : = A2 4.91mm = (downward)
So, total deflection
Atot A2 A1 : = Atot 1.93mm = (downward )
L
2500
7.6mm = OK !
Allowable deflection




1.3 Continous Girder

Allowable Stress in Girder : (SNI 2847 2002)
fci2 0.6 f'
ci
: = fci2 27 MPa =
fti2 0.25 f'
ci
MPa : = fti2 1.68MPa = (regi on other then support)
ftip2 0.5 f'
ci
MPa : = ftip2 3.35MPa = (support regi on)
fc2 0.6 f'
c
: = fc2 30 MPa = (due to prestress + total l oad)
ft2 0.5 f'
c
MPa : = ft2 3.54MPa = (tension stress l i mit)

Internal Force
Distance
m
MuLL MLL Tegangan Tegangan phi*Mn MuDL/ton.m MDL/ton.m
phi*Mn-
MuDL
Moment
+
Moment
+
Serat
Atas
Serat
Bawah

0 246.3 113.6 -0.95 -0.95 491.15 0.00 0.00 491.15
3.333 295.85 136.0442 -2.05 0.14 595.09 133.5387432 95.384817 461.55
6.667 343.538 145.533 -2.50 0.59 633.89 213.8384439 152.74175 420.05
10 389.2 142 -2.65 0.74 646.61 240.56 171.83 406.05
13.333 309.746 102.9724 -2.50 0.59 633.89 213.8865299 152.77609 420.00
16.667 261.432 88.2343 -2.06 0.15 595.09 133.6349946 95.453568 461.45
20 244.5 97.9 -0.95 -0.95 491.15 0.00 0.00 491.15

MuLLmax
sp
246.3ton m : = MLLmax
sp
113.6ton m : = bot_stress
15
0.74 =
MuLLmax
mid
389.2ton m : = MLLmax
mid
142ton m : =





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 26 of 47

II. a) Estimate number of Required Strands
f
pe ff2
0.75f
pi
: = f
pe ff2
962.55MPa = Total l oss = l ong term l osses +1.5 x fri cti on l osses
j acki ng from both si de >> L = 50 m
IN MIDSPAN
Estimated based on stress condi tion in bottom fi ber
bottom fiber stress : bot_stre ss
15
MPa 0.74MPa = tension ( )
Peff3 1 ton : = e2
mid
350mm : =
Given
Peff3
A
mid

Peff3e2
mid

S
bm id

MLLmax
mid
S
bm id
+ ft bot_stre ss
15

|
\
|
.
MPa =
Pf3 Find Peff3 ( ) : = Pf3 28.8ton =
Estimated based on ulti mate strength of the secti on
h a
mid
: = h 1.8m =
| Aps 0.95 fpu 0.9h MuLLma x
mid
> |
b
0.8 =
Aps
MuLLma x
mid
|
b
0.9h ( ) 0.95f
pu

: = Aps 1667mm
2
=
Pf4 Aps f
pe ff2
: =
Pf4 163.6ton =
Effecti ve prestressing force
Pf_cont1 ma x Pf3 Pf4 ( ) ( ) : =
Pf_cont1 163.59ton =
Aps_cont1
Pf_cont1
f
pe ff2
: =
Aps_cont1 1667mm
2
=
Determi ne the number of strands used
n
strand_cont1
Aps_cont1
Aps1
|

\
|
|
.
: = n
strand_cont1
16.89 =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 27 of 47

IN SUPPORT
Estimated based on stress condi tion in top fi ber
top fiber stress : top_stre ss
0
MPa 0.95 MPa = compre ssion ( )
A
sp
A 0 ( ) : = A
sp
1.44m
2
= MLLmax
sp
113.6ton m =
Sb
sp
Sb
0
: = Sb
sp
433L =
Peff5 1 ton : = e2
sp
700mm : =
Given
Peff5
A
sp

Peff5e2
sp

Sb
sp

MLLmax
sp
Sb
sp
+ ft top_stre ss
0

|
\
|
.
MPa = a
mid
1.8m =
Pf5 Find Peff5 ( ) : = Pf5 84.6 ton =
Estimated based on ulti mate strength of the secti on
h a
mid
: = h 1.8m =
| Aps 0.95 fpu 0.9h MuLLma x
sp
> |
b
0.8 =
Aps
MuLLma x
sp
|
b
0.9h ( ) 0.95f
pu

: = Aps 1055mm
2
=
Pf6 Aps f
pe ff2
: =
Pf6 103.5ton =
Effecti ve prestressing force
Pf_cont2 ma x Pf5 Pf6 ( ) ( ) : =
Pf_cont2 103.53ton =
Aps_cont2
Pf_cont2
f
pe ff2
: = Aps_cont2 1055mm
2
=
Determi ne the number of strands used
n
strand_cont2
Aps_cont2
Aps1
|

\
|
|
.
: = n
strand_cont2
10.69 =
Number of Strands
n
strand_cont
ma x n
strand_cont1
n
strand_cont2
,
( )
: = n
strand_cont
16.89 =
Use n
strand_cont
20 : =
2 x 10 D5"
Total area of stress Aps_cont n
strand_cont
Aps1 : = Aps_cont 1974mm
2
=
Ini ti al Stress f
pi
0.65f
pu
: = f
pi
1209MPa =
Prestressi ng Forces Pi2 f
pi
Aps_cont : = Pi2 243.362ton =
Jacki ng Forces Pj 2 f
pj
Aps_cont : = Pj 2 280.802ton =



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 28 of 47




6) Prestress Losses
Losses for 8 strands


PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 29 of 47

Design Variables
nc 0 1 , 6 .. : =
Strand area at any secti on Aps_cont 1974mm
2
=
Ini ti al Strand force Fi2
nc
Aps_contfpi : = fpi 1074.46MPa =
Final Strand force Ff2
nc
f
pe ff2
Aps_cont : =
fti fti2 : = fti 1.68MPa =
fci fci2 : = fci 27000000 Pa =
Stress at Initial Conditions (w/o LL)
top2_i
nc
top_stre ss2
nc
MPa
Fi2
nc
A2
nc

Fi2
nc
ec c2
nc
mm
St2
nc
+ : =
Ini ti al stress i n top
Ini ti al stress i n bottom bot2_i
nc
bot_stre ss2
nc
MPa
Fi2
nc
A2
nc

Fi2
nc
ec c2
nc
mm
Sb2
nc
: =
Pass fai l conditi on check2_i
nc 0 ,
xc
nc
: =
check2_i
nc 3 ,
"top fail" top2_i
nc
0 > top2_i
nc
fti > . if
"top fail" top2_i
nc
0 < top2_i
nc
fci < . if
"top OK" othe rwise
othe rwise
: =
check2_i
nc 6 ,
"bot fail" bot2_i
nc
0 < bot2_i
nc
fci < . if
"bot fail" bot2_i
nc
0 > bot2_i
nc
fti > . if
"bot OK" othe rwise
othe rwise
: =
check2_i
nc 1 ,
top2_i
nc
MPa
: = check2_i
nc 4 ,
bot2_i
nc
MPa
: =
check2_i
nc 2 ,
fti
MPa
top2_i
nc
0MPa > if
fci
MPa
othe rwise
: = check2_i
nc 5 ,
fti
MPa
bot2_i
nc
0MPa > if
fci
MPa
othe rwise
: =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 30 of 47

column 0 = span point
column 1 = top stress
column 2 = top allowable
column 3 = top check
column 4 = bottom stress
column 5 = bottom allowable
column 6 = bottom check
check2_i
0 1 2 3 4 5 6
0
1
2
3
4
5
6
0 -5.86 -27 "top OK" 1.01 1.68 "bot OK"
3.33 -4.09 -27 "top OK" -0.76 -27 "bot OK"
6.67 -2.83 -27 "top OK" -2.03 -27 "bot OK"
10 -2.4 -27 "top OK" -2.45 -27 "bot OK"
13.33 -2.83 -27 "top OK" -2.03 -27 "bot OK"
16.67 -4.1 -27 "top OK" -0.75 -27 "bot OK"
20 -5.86 -27 "top OK" 1.01 1.68 "bot OK"
=


fti
fti2
MPa
: = fci
fci2
MPa
: = top2_stress
nc
check2_i
nc 1 ,
: = bot2_stress
nc
check2_i
nc 4 ,
: =
0 5 10 15 20
30
20
10
0
10
Initial Stress
top2_stress
nc
fti
bot2_stress
nc
fci
xc
nc
Positive moment envelope at Service
ft
ft2
MPa
: = fc
fc2
MPa
: =
Final stress top SI2_pt
nc
top_stre ss2
nc
MPa
Ff2
nc
A2
nc

Ff2
nc
ec c2
nc
mm
St2
nc
+
MLL2
nc
ton m
St2
nc
: =
Final stress i n bottom SI2_pb
nc
bot_stre ss2
nc
MPa
Ff2
nc
A2
nc

Ff2
nc
ec c2
nc
mm
Sb2
nc

MLL2
nc
ton m
Sb2
nc
+ : =





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 31 of 47

Positive moment envelope at Service
ft
ft2
MPa
: = fc
fc2
MPa
: =
Final stress top SI2_pt
nc
top_stre ss2
nc
MPa
Ff2
nc
A2
nc

Ff2
nc
ec c2
nc
mm
St2
nc
+
MLL2
nc
ton m
St2
nc
: =
Final stress i n bottom SI2_pb
nc
bot_stre ss2
nc
MPa
Ff2
nc
A2
nc

Ff2
nc
ec c2
nc
mm
Sb2
nc

MLL2
nc
ton m
Sb2
nc
+ : =
Pass fai l conditi on
check2_f
nc 0 ,
xc
nc
: =
check2_f
nc 3 ,
"top fail see SIII" SI2_pt
nc
0MPa > |
\
|
.
SI2_pt
nc
ft MPa > . if
"top fail" SI2_pt
nc
0MPa < SI2_pt
nc
fc MPa < . if
"top OK" othe rwise
othe rwise
: =
check2_f
nc 6 ,
"bot fail see SIII" SI2_pb
nc
0MPa < |
\
|
.
SI2_pt
nc
fc MPa < . if
"bot fail" SI2_pb
nc
0 > SI2_pb
nc
ft MPa > . if
"bot OK" othe rwise
othe rwise
: =
check2_f
nc 1 ,
SI2_pt
nc
MPa
: = check2_f
nc 4 ,
SI2_pb
nc
MPa
: =
check2_f
nc 2 ,
ft SI2_pt
nc
0MPa > if
fc othe rwise
: = check2_f
nc 5 ,
ft SI2_pb
nc
0MPa > if
fc othe rwise
: =


column 0 = span point
column 1 = top stress
column 2 = top allowable
column 3 = top c hec k
column 4 = bottom stre ss
column 5 = bottom allowable
column 6 = bottom che ck
check2_f
0 1 2 3 4 5 6
0
1
2
3
4
5
6
0 -7.93 -30 "top OK" 3.38 3.54 "bot OK"
3.33 -6.97 -30 "top OK" 2.42 3.54 "bot OK"
6.67 -6.1 -30 "top OK" 1.55 3.54 "bot OK"
10 -5.65 -30 "top OK" 1.1 3.54 "bot OK"
13.33 -5.13 -30 "top OK" 0.58 3.54 "bot OK"
16.67 -5.89 -30 "top OK" 1.34 3.54 "bot OK"
20 -7.58 -30 "top OK" 3.03 3.54 "bot OK"
=
top_stre ss2
nc
check2_f
nc 1 ,
: = bot_stre ss2
nc
check2_f
nc 4 ,
: =
0 5 10 15 20
30
20
10
0
10
Final Stress
top_stre ss2
nc
ft
bot_stre ss2
nc
fc
xc
nc






PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 32 of 47

column 0 = span point
column 1 = top stress
column 2 = top allowable
column 3 = top c hec k
column 4 = bottom stre ss
column 5 = bottom allowable
column 6 = bottom che ck
check2_f
0 1 2 3 4 5 6
0
1
2
3
4
5
6
0 -7.93 -30 "top OK" 3.38 3.54 "bot OK"
3.33 -6.97 -30 "top OK" 2.42 3.54 "bot OK"
6.67 -6.1 -30 "top OK" 1.55 3.54 "bot OK"
10 -5.65 -30 "top OK" 1.1 3.54 "bot OK"
13.33 -5.13 -30 "top OK" 0.58 3.54 "bot OK"
16.67 -5.89 -30 "top OK" 1.34 3.54 "bot OK"
20 -7.58 -30 "top OK" 3.03 3.54 "bot OK"
=
top_stre ss2
nc
check2_f
nc 1 ,
: = bot_stre ss2
nc
check2_f
nc 4 ,
: =
0 5 10 15 20
30
20
10
0
10
Final Stress
top_stre ss2
nc
ft
bot_stre ss2
nc
fc
xc
nc


Flexural Strength - LRFD 5.7.3.1.1 stress in prestressing tendons
|
1
0.85 f'
c
30MPa s if
0.65 f'
c
55MPa > if
0.85
0.05
7MPa
f'
c
30MPa ( )

(
(

30MPa f'
c
< 55MPa s if
: = f'
c
50MPa =
|
1
0.71 =
Non-prestressing bars :
fy 400MPa : = d' 5cm : =
d
b
25mm : = As1 0.25t d
b
2
: =
nbar2
t
18 : = Ast2
nc
nbar2
t
As1 : = tension ( )
nbar2
c
10 : = Asc2
nc
nbar2
c
As1 : = negl eted comp.bars in
calcul ation
d2
nc
H_c ont
nc
m 88mm : =
dp_cont
nc
Strand_c ont
nc
mm : =
t2
nc
Ast2
nc
b d2
nc

: =
c2
nc
Asc2
nc
b d'
: = c
2mp
0.08 =
et2
nc
t2
nc
fy
f'
c
: =
ec2
nc
c2
nc
fy
f'
c
: =
Prestressing tendons :
p 0.28 : = Low Rel axati on strand
Aps_cont 1974mm
2
= b 0.8m =
p2
nc
Aps_cont
b dp_cont
nc

: =
f
pu
1860MPa = f'
c
50MPa =
fps2
nc
f
pu
1
p
|
1
p2
nc
f
pu
f'
c

d2
nc
dp_cont
nc
et2
nc
ec2
nc

( )
+

(
(
(

(
(
(

: =



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 33 of 47

Flexural Strength - LRFD 5.7.3.1.1 stress in prestressing tendons
|
1
0.85 f'
c
30MPa s if
0.65 f'
c
55MPa > if
0.85
0.05
7MPa
f'
c
30MPa ( )

(
(

30MPa f'
c
< 55MPa s if
: = f'
c
50MPa =
|
1
0.71 =
Non-prestressing bars :
fy 400MPa : = d' 5cm : =
d
b
25mm : = As1 0.25t d
b
2
: =
nbar2
t
18 : = Ast2
nc
nbar2
t
As1 : = tension ( )
nbar2
c
10 : = Asc2
nc
nbar2
c
As1 : = negl eted comp.bars in
calcul ation
d2
nc
H_c ont
nc
m 88mm : =
dp_cont
nc
Strand_c ont
nc
mm : =
t2
nc
Ast2
nc
b d2
nc

: =
c2
nc
Asc2
nc
b d'
: = c
2mp
0.08 =
et2
nc
t2
nc
fy
f'
c
: =
ec2
nc
c2
nc
fy
f'
c
: =
Prestressing tendons :
p 0.28 : = Low Rel axati on strand
Aps_cont 1974mm
2
= b 0.8m =
p2
nc
Aps_cont
b dp_cont
nc

: =
f
pu
1860MPa = f'
c
50MPa =
fps2
nc
f
pu
1
p
|
1
p2
nc
f
pu
f'
c

d2
nc
dp_cont
nc
et2
nc
ec2
nc

( )
+

(
(
(

(
(
(

: =

Width of concrete stress is determined below:
Tps2
nc
fps2
nc
Aps_cont Ast2
nc
f
y
+ : =
To ensure that the bar will be yield, so code restricts :
ep2
nc
p2
nc
fps2
nc
f'
c
: =
check_yield2
nc
"yield" ep2
nc
d2
nc
dp_cont
nc
et2
nc
ec2
nc

( )
+ 0.36|
1
s if
"not yield" othe rwise
: =



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 34 of 47

Depth of compressive stress block :
a2
nc
Aps_contfps2
nc
Ast2
nc
fy +
0.85f'
c
|
1
b
: =
Flexural Strength : | 0.8 : =
|Mn2
nc
| Aps fps2
nc
dp_cont
nc
a2
nc
2

\
|
|
.
Ast2
nc
fy d2
nc
a2
nc
2

\
|
|
.
+

(
(

: =
Check pass or fail condi ti on check_m2
nc
"OK" |Mn2
nc
MuLL2
nc
ton m > if
"FAIL" othe rwise
: =
Prepare for output di spl ay
disp_f
nc 0 ,
xc
nc
: = disp_f
nc 3 ,
check_yield2
nc
: = disp_f
nc 6 ,
check_m2
nc
: =
disp_f
nc 1 ,
Aps_cont
mm
2
: = disp_f
nc 4 ,
MLL2
nc
: =
disp_f
nc 2 ,
dp_cont
nc
mm
: = disp_f
nc 5 ,
|Mn2
nc
ton m
: =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 35 of 47





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 36 of 47

Pass fai l conditi on
check3_f
nc 0 ,
xc
nc
: =
check3_f
nc 3 ,
"top fail see SIII" SI_nt
nc
0MPa > |
\
|
.
SI_nt
nc
ft MPa > . if
"top fail" SI_nt
nc
0MPa < SI_nt
nc
fc MPa < . if
"top OK" othe rwise
othe rwise
: =
check3_f
nc 6 ,
"bot fail see SIII" SI_nb
nc
0MPa < |
\
|
.
SI_nt
nc
fc MPa < . if
"bot fail" SI_nb
nc
0 > SI_nb
nc
ft MPa > . if
"bot OK" othe rwise
othe rwise
: =
check3_f
nc 1 ,
SI_nt
nc
MPa
: = check3_f
nc 4 ,
SI_nb
nc
MPa
: =
check3_f
nc 2 ,
ft SI_nt
nc
0MPa > if
fc othe rwise
: = check3_f
nc 5 ,
ft SI_nb
nc
0MPa > if
fc othe rwise
: =
column 0 = span point
column 1 = top stress
column 2 = top allowable
column 3 = top c hec k
column 4 = bottom stre ss
column 5 = bottom allowable
column 6 = bottom che ck
check3_f
0 1 2 3 4 5 6
0
1
2
3
4
5
6
0 -7.94 -30 "top OK" 0.75 3.54 "bot OK"
3.33 -6.6 -30 "top OK" -0.58 -30 "bot OK"
6.67 -5.38 -30 "top OK" -1.81 -30 "bot OK"
10 -4.59 -30 "top OK" -2.6 -30 "bot OK"
13.33 -4.12 -30 "top OK" -3.06 -30 "bot OK"
16.67 -5.3 -30 "top OK" -1.89 -30 "bot OK"
20 -7.77 -30 "top OK" 0.59 3.54 "bot OK"
=




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 37 of 47

top_stre ss3
nc
check3_f
nc 1 ,
: = bot_stre ss3
nc
check3_f
nc 4 ,
: =
0 5 10 15 20
30
20
10
0
10
Final Stress
top_stre ss3
nc
ft
bot_stre ss3
nc
fc
xc
nc

Check Deflections TENDON II
Pi2 2386566N =
11.1. Calculate initial deflection
Chamber due to initial prestress only
Imid Ix
15
: =
Api2
5 Pi2 e2
mid
L
2

48E
ci
Imid
: = Api2 2.83 mm = (upward)
ME
w
ca ble
0.1
ton
m
: =
Abs2
5
384
w
ca ble
L
4

E
ci
Imid
: =
Abs2 0.17mm = (downward)
Live Load deflection
ALL
5
48
MLLmax
mid
L
2

E
ci
Imid
: = ALL 4.72mm = (downward)
Long term deflect ion by PCI Multipliers
A1c ont 1.85 Abs ( ) 1.8 Api Api2 + ( ) + : = A1c ont 0.81 mm = (upward)
Allowable deflection
L
2500
8 mm = OK !
So, the total of longterm deflection :
A2c ont 2.45 Api Api2 + ( ) 2.7 Abs ( ) + 3 Abs2 + ALL + : = A2c ont 5.16mm = (downward)
A2c ont' 2.45 Api Api2 + ( ) 2.7 Abs ( ) + 3 Abs2 + : = A2c ont' 0.44mm = (downward)
So, total deflection
Atot A2c ont A1c ont : = Atot 5.97mm =
(downward)
Allowable deflection
L
2500
8 mm = OK !







PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 38 of 47

Check Deflections TENDON II
Pi2 2386566N =
11.1. Calculate initial deflection
Chamber due to initial prestress only
Imid Ix
15
: =
Api2
5 Pi2 e2
mid
L
2

48E
ci
Imid
: = Api2 2.83 mm = (upward)
ME
w
ca ble
0.1
ton
m
: =
Abs2
5
384
w
ca ble
L
4

E
ci
Imid
: =
Abs2 0.17mm = (downward)
Live Load deflection
ALL
5
48
MLLmax
mid
L
2

E
ci
Imid
: = ALL 4.72mm = (downward)
Long term deflect ion by PCI Multipliers
A1c ont 1.85 Abs ( ) 1.8 Api Api2 + ( ) + : = A1c ont 0.81 mm = (upward)
Allowable deflection
L
2500
8 mm = OK !
So, the total of longterm deflection :
A2c ont 2.45 Api Api2 + ( ) 2.7 Abs ( ) + 3 Abs2 + ALL + : = A2c ont 5.16mm = (downward)
A2c ont' 2.45 Api Api2 + ( ) 2.7 Abs ( ) + 3 Abs2 + : = A2c ont' 0.44mm = (downward)
So, total deflection
Atot A2c ont A1c ont : = Atot 5.97mm =
(downward)
Allowable deflection
L
2500
8 mm = OK !


1.4 Daerah Pengangkuran

XIV. DESIGN ANCHORAGE ZONE
SIMPLE BEAM
Pl ate of anchorage TIDAKUSAH ( )
The number of plate nt 2 : =
Widt h of plate a' ' 215mm : =
Diameter hole Dlub 86mm : =
Net area of plate Aanet a' '
2
0.25t Dlub
2
: = Aanet 40416.195mm
2
=
Out er side b 800mm : =
sp_angkur 1400 600 ( )mm : = sp_angkur 0.8m = > a' ' 215mm = OK!
sa sp_angkur b sp_angkur > if
b othe rwise
: = sa 800mm =
Out er area A2 sa b : = A2 640000mm
2
=
Inner area A1 a' ' a' ' : = A1 46225mm
2
=
Reinforcement of Gl obal Anchorage Zones
| 0.85 : = LF 1.2 : =




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 39 of 47

The number of tendon in 1 plate Np1
n
strand_simple
2
: = Np1 7 =
Pp1 Np1 Aps1 0.75 f
pu
LF : = Pp1 117.94ton =
End Bearing St ress fci fci MPa : = fci 27MPa =
EBS
Pp1
Aanet
: =

A2
A1
: = i f > 2, take 2 3.72 =
2 2 > if
othe rwise
: = 2 =
EBS 28.62MPa = < | 0.7 fci 32.13MPa = OK
< | 2.25 fci 51.64MPa =
check1 "OK" EBS | 0.7 fci s EBS | 2.25 fci s . if
"FAIL" othe rwise
: = check1 "OK" =
Psu/2
Psu/2
Psu/2
T burst
dburst
D
B
A
C
e

=

3
0
0

m
m
a = 300 mm
Psu/2
150
450
366.67 mm
661.11 mm




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 40 of 47

at Mi d Span
P
su1
LF n
strand_simple
Aps1 0.75 f
pu
: =
P
su1
235.87ton =
P
su2
0.96n
strand_simple
Aps1 f
pu
: =
P
su2
251.6ton =
P
su.mid
min P
su1
P
su2
,
( )
: =
P
su.mid
235.87ton =
a' 215mm : = h' 1800mm : =
e' 300mm : =
d
burst
0.5 h' 2 e' ( ) : = d
burst
600mm =
T
burst.mid
0.25P
su.mid
1
a'
h'

\
|
|
.
: = T
burst.mid
51.93ton =
P
CD
T
burst.mid
: = P
CD
51.93ton =
P
EF
P
su.mid
2
200 165 ( )
400
: = P
EF
10.32ton =

Transversal Reinforcement
The burst ing zone reinforcement|S 0.85 : =
fy 400MPa : =
As
mid
T
burst.mid
|S fy
: = As
mid
1497.678mm
2
=
Used closed ties reinforcement with diameterdt 13mm : =
Atr1 0.25t dt
2
: = Atr1 132.732mm
2
=
N1
mid
ce il
As
mid
2 Atr1
|

\
|
|
.
: = N1
mid
6 = used 6D13
spasi tulangan daerah angkur, s
h
N1
mid
1
: = s 360mm =
j adi untuk brusting zone, rei nforcement butuh 6 D13-360mm
The spalling zone force reinforcement is provided t o resist tensile force 0.02P
su.mid
4.72ton =
use reinforcement diameter dt 13mm : =
Atr2 0.25t dt
2
: = Atr2 132.73mm
2
=
N2
mid
ce il
0.02P
su.mid

Atr20.5 fy
|

\
|
|
.
: = N2
mid
2 = used 2D13
spasi tulangan daerah angkur
(verti kal ),
s1
b
N2
mid
1
: = s1 800mm =
j adi untuk spal li ng zone, reinforcement butuh 2 D13-800mm
spasi tulangan daerah angkur
(horizontal ),
s2
h
N2
mid
1
: = s2 1800mm =
j adi untuk spal li ng zone, reinforcement butuh 2 D13-1800mm





PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 41 of 47

Transversal Reinforcement
The burst ing zone reinforcement|S 0.85 : =
fy 400MPa : =
As
mid
T
burst.mid
|S fy
: = As
mid
1497.678mm
2
=
Used closed ties reinforcement with diameterdt 13mm : =
Atr1 0.25t dt
2
: = Atr1 132.732mm
2
=
N1
mid
ce il
As
mid
2 Atr1
|

\
|
|
.
: = N1
mid
6 = used 6D13
spasi tulangan daerah angkur, s
h
N1
mid
1
: = s 360mm =
j adi untuk brusting zone, rei nforcement butuh 6 D13-360mm
The spalling zone force reinforcement is provided t o resist tensile force 0.02P
su.mid
4.72ton =
use reinforcement diameter dt 13mm : =
Atr2 0.25t dt
2
: = Atr2 132.73mm
2
=
N2
mid
ce il
0.02P
su.mid

Atr20.5 fy
|

\
|
|
.
: = N2
mid
2 = used 2D13
spasi tulangan daerah angkur
(verti kal ),
s1
b
N2
mid
1
: = s1 800mm =
j adi untuk spal li ng zone, reinforcement butuh 2 D13-800mm
spasi tulangan daerah angkur
(horizontal ),
s2
h
N2
mid
1
: = s2 1800mm =
j adi untuk spal li ng zone, reinforcement butuh 2 D13-1800mm


1.6 Desain Tulangan Tarik dan Tekan

b 800mm :=
p
0.28 := low relaxation tendon
h 1800mm := e
sp
700mm := D 25mm :=
f'
c
50MPa := e
mid
350mm := 0.8 :=
f
y
400MPa := e
spext
250mm := n
strand
20 :=
sbeton 50mm :=
f
pu
1860MPa :=
strand
0.5in :=
y
cgc
h
2
900 mm = :=
1
0.85 0.008
f'
c
MPa
30
( )
0.69 = :=
A
strand
98.7mm
2
:=
A
s
0.25 D
2
490.874 mm
2
= :=
A
ps
n
strand
A
strand
1974 mm
2
= :=


AT SUPPORT
ns
bot
10 :=
ns
top
8 :=
MuLL
pos_sp
2423kN m :=
MuLL
neg_sp
5875kN m :=
'



PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 42 of 47






PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 43 of 47




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 44 of 47




PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 45 of 47



ns
bot
10 :=
ns
top
8 :=
MuLL
pos_supext
3855 kN m :=
MuLL
neg_supext
1119kN m :=
e
spext
0.25m =




AT SUPPORT EXTERIOR


PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 46 of 47






PERHITUNGAN GUIDE WAY BEAM APMS BANDARA
SOEKARNO - HATTA

NO. PEKERJAAN : _________
NO. DOKUMEN : 02
TANGGAL
13 Mei 2014
REVISI
0


PT. ADHI KARYA (PERSERO) tbk Hal. 47 of 47





Berdasarkan perhitungan dan analisa yang telah dilakukan di atas maka kebutuhan strand dan tulangan dapat
ditabelkan seperti tabel di bawah ;

Strand Tul. Tekan Tul. Tarik Sengkang
Span Tendon Cont. Tendon
2 x 7 Strand
D12.7 mm
2 x 10 Strand
D12.7 mm
8 D 25 10 D 25 D13-100 & D13-
150

Untuk detail penulangan dapat dilihat pada gambar detail penulangan Guide Way Beam.