Você está na página 1de 2

DN(mm)

10, 15, 20
25, 32
40, 50
65, 80
100,125
150
200
250
300
350

A
60
80
115
122
170
180
235
290
335
355

B
180
197
232
239
287
297
352
407
452
467

C
115
150
220
233
330
350
460
570
660
690

D
200
200
200
200
250
300
350
400
500
550

E
76
96
102
102
132
172
207
242
292
292

FLOW METER SIZE


DN 10 : 3/8
DN 15 :
DN 20 :
DN 25 : 1
DN 32 : 1
DN 40 : 1
DN 50 : 2
DN 65 : 2
LINER
LM01
LM02
LM03
LM04
LM05
LM06

Dimensions are with ANSI 150 Flanges, with terminal box.


(for other flange rating consult factory)
Dimension 'D' is without earthing rings.
Standard flanges ANSI 150 up to DN 150
Bs10, Table F : DN 200 & onwards.

DN
DN
DN
DN
DN
DN
DN
DN

80
100
125
150
200
250
300
350

:
:
:
:
:
:
:
:

....a name that spells trust


AN ISO 9001: 2000 COMPANY

3
4
5
6
8
10
12
14

MATERIAL
: PTFE
: Neoprene
: Soft Rubber
: Hard Rubber
: PFA
: Any Other

ELECTRODE MATERIAL
EM01 : Stainless Steel 316
EM02 : Stainless Steel 316L
EM03 : Hastelloy C
EM04 : Tantalum
EM05 : Titanium
EM06 : Any Other

110
57
B

FLANGE/END CONNECTION STANDARDS


FS 01 : DIN PN 40
FS 02 : DIN PN 16
FS 03 : DIN PN 10
FS 04 : ANSI 300
FS 05 : ANSI 150
FS 06 : BS 10, Table F
FS 07 : BS 10, Table D
FS 08 : SMS union coupling
FS 09 : Tri-clamp
FS 10 : Any Other

A
E
D

CMYK

manas

ORDERING INFORMATION

Meter Dimensions (mm)

75

FLANGE/END CONNECTION MATERIAL


FM01 : Carbon Steel
FM02 : Stainless Steel 304
FM03 : Stainless Steel 316
FM04 : Stainless Steel 316L

FLOW TRANSMITTER
FT 01 : Integral
FT 02 : Remote
POWER SUPPLY
01
: 110 V AC 10%, 50 Hz
02
: 230 V AC 10%, 50 Hz
03
: 24 V DC 10%

DN 25

LM 01

EM 01

FS 05

FM 01

BM 01

FT 01

02

Crownsp @ vsnl.com feb 2009-1000

BODY MATERIAL
BM01 : Mild Steel
BM02 : SS 304
BM03 : SS 316
BM04 : SS 316 L

Sample Order Code

Due to continuous development specifications are subject to change without prior notice.

manas microsystems pvt. ltd.


REGD. OFFICE : ROW HOUSE NO. 5, PARVATI PARK, DATTAWADI, PUNE 411 030
WORKS : EL 54 ELECTRONIC ZONE, M.I.D.C. BHOSARI, PUNE 411 026. (INDIA)
TEL. : 020-27127044,27127047, 27127858 FAX : 020-27127045
E-MAIL : mktg@manasmicro.com WEBSITE : www.manasmicro.com

BSI

TM

Most Trusted Product with CE Certification

QM 008

Catalog No : Fc - FBE- 05

ELECTROMAGNETIC FLOW-METER (FULL BORE)

ELECTROMAGNETIC FLOW METER SROAT -1000

PRINCIPAL ADVANTAGES :

INTRODUCTION :

1. Use of pulsed DC magnetisation & auto zero technique offers


excellent long term zero stability.

The Manas Make electromagnetic flow meter called as SROAT-1000


virtually approaches the ideal flow meter suitable for wide range of
liquid flow measurements even with very low conductivities. The meter
offers no resistance to flow hence the pressure drop is almost
negligible. The measurement being based on Faraday's law of
electromagnetic induction, is independent of visocity, density, pressure
& temperature of flowing medium. The measurement is not affected by
solid impurities as long as the min. conductivity of 5s/cm is
available. It is a true volumetric flow measurement.We offer various
materials of construction for meter lining & electrodes to cover majority
of corrosive liquids.

2. Measurement is independent of velocity profile across the


diameter of the pipe-line.

The technique called as Pulsed DC is used which offers very high


zero stability & accuracy of measurement. The standard current output
of 4-20 mA DC is provided which is linearly proportional to volumetric
flow rate.

SPECIFICATIONS
METERING TUBE : SROAT 1000

2.

3. Measurement results are independent of density, viscosity,


pressure, temperature , solid - impurities & conductivity
variations [above 5 s / cm].

3.

4. No additional pressure drop across the meter which relieves the


process designer while sizing his pumping requirements.
Simple to install as no special precautions of straight pipe
lengths required.

6. Protection class offered IP 65.


7. Reasonably higher ratio of Return on Investment to Investment.

6.
7.

: DN 10 to DN 350
for higher sizes consult factory
Media Pressure
: Upto DN 80- PN 40
From DN 100 to DN 200 - PN 16
DN 250 to DN 350 - PN 10
Media Temperature
: PFA Liner : 0 - 200C max.
PTFE Liner : 0 - 150C max.
Rubber Liner : 0 - 90C max.
Ambient Temperature Range : 0 - 50c
Materials : Pipe
: SS 304 [non-magnetic ]
Electrode
: SS 316 / SS316L/Hastelloy C / Ta /Ti.
Liner
: PTFE / Neoprene /Soft Rubber /
Hard Rubber/PFA.
Flanges
: Carbon Steel / SS 316 / SS 316 L /
SS 304.
Body Material : Carbon Steel, P. U.painted./ SS 304/ SS 316
Flange Standard
: ANSI / DIN /BS / SMS / Triclamp
Power Supply to field coils : Pulsed DC

In this case the conductor is flowing media. The equation is as below.


B.v.d.

APPLICATIONS :

1. Mounting

This meter is more suitable with those fluids which present


difficulties in handling. Fluids such as effluents, slurries, pulps,
brines & other highly corrossive liquids, acids & bases, fermenterwash, molasses etc.

2. Min. Media Conductivity


3. Signal Output
Additional option

Following industries can find lot of application of this flow


measurement technique.

Induced voltage [ proportional to velocity ]


Magnetic flux density.
Mean velocity of the media
Distance between the sensing electrodes

6. Flow Velocity Range


7. Accuracy

8. Ref. Conditions
9.
10.
11.
12.
13.
14.
15.
16.

: Integral mounted [standard]


Remote Mounted [on request]
: 5 s /cm [for lower conductivities
consult factory]
: 4-20 mA dc isolated in max. 600 ohms
: Pulsed Output With adjustable count
rate from 1 count / Hr to 105 Counts/ Hr.
[Open collector with 100 mA/24 V dc
capacity]

FLOW RATE TABLE :

For a given size of flow tube & compatible amplifier the flux density 'B' is
constant, the distance between the electrodes is constant. Hence, the
induced voltage is proportional to the velocity of the flowing media.
Thus, the unit can be calibrated in terms of volumetric flow rate by
knowing the cross-sectional area of the Tube.

l
l
l
l
l
l
l
l
l

Effluent Treatment Plants


Sewage Treatment Plants.
Water Supply Schemes.
Steel & Aluminium.
Sugar Industries & Distilleries.
Pulp & Paper.
Chemical / Pharmaceutical.
Petrochemicals / Fertilizers.
Food & Drugs.

DN
10
15
20
25
32
40
50
65

M3/Hr.
0.282
0.636
1.130
1.767
2.895
4.523
7.068
11.945

LPM
4.712
10.602
18.849
29.452
48.254
75.398
117.809
199.098

M3/Hr.
18.095
28.274
44.178
63.617
113.097
176.714
254.469
346.356

LPM
301.592
471.238
736.310
1060.287
1884.955
2945.243
4241.150
5772.608
DN 350
DN 300
DN 250
DN 200

DN 150
DN 125
DN 100
DN 80
DN 65
DN 50

DN 40
DN 32

DN 25

1.5

DN
80
100
125
150
200
250
300
350
DN 20
DN 15

10 m/s
9
8
7
6
5

2.0

17. Ingress Protection

LPS
0.078
0.176
0.314
0.490
0.804
1.256
1.963
3.318

Flow Nomograph

2.5

Repeatability
Ambient Temperature
Temperature Drift
Humidity
Material of Housing
Power Supply
Damping
Cable Entries

: Selectable by DIP switch.


a) 25Hz
B) 12.5 Hz
c) 6.25 Hz
d) 3.125 Hz
: a) 3 digit LCD calibrated in % or
in engineering units for flow rate
indication
b) 8 digit LCD non resettable type
for totalised quantity.
: 0.1 m/s to 10 m/s
: 0.5% of reading [at ref. conditions]
between 100% to 10% of calibrated
range
0.75% of reading for flow rate
between 10% to 5%
[refer accuracy graph ]
: Power supply nominal.
Temperature 27c 2c
: 0.2% of reading
: 0 50c
: 0.015% per c max.
: 90 % R. H. max. non condensing
: Al. Die cast.
: 230 V ac/ 110 V ac, 50 Hz/24 V dc.
: Adjustable from 5 to 30 Secs.
: 4 no. For Remote Amplifier
2 no. For Integral Amplifier
PG11/ NPT / BSP / [Female]
: IP-65

Flow rate at v = 1m/s

DN 10

ERROR DIAGRAM

1.0

Flow velocity in m/s

% ERROR OF ACTUAL FLOW

5. Local Display

TRANSMITTER SROAT 1000 A

The method of flow measurement is based on Faraday's law of


electromagnetic induction. When a conductor moves within a magnetic
field, voltage is induced in it which is proportional to the velocity of
conductor.

CMYK

4.
5.

5. Compatible with virtually all corrosive / non-corrosive liquids.

PRINCIPLE OF OPERATION :

E =
where,
E =
B =
v =
d =

4. Coil Excitation Frequency

1. Meter Size

0.5
0
- 0.5
- 1.0
- 1.5

1
0.9
0.8
0.7
0.6
0.5
0.4

- 2.0

0.3

- 2.5

0.2

90

100

Flow rate in m /h

80

m /h

FLOW AS PERCENTAGE OF RANGE

70

10000

60

1000

50

100

40

10

30

20

0.1

10

0.01

LPS
5.026
7.853
12.271
17.671
31.415
49.087
70.685
96.210

Você também pode gostar