Menu Structure Of The Monitoring Module

Appendix 3 Menu Structure Of The Monitoring Module


Main Menu

Status

Maintenance
DC Voltage

FC

DC Current

Start

AC on/off
Rectifiers

Battery

AC Voltage
AC Derated

Load

Temp Derated
Alarm serial No.
Alarm level

Reconnect
Disconnect

Alarm
Mode

Reconnect
Alarm
Control

Rect Trim
Rect Limit

Alarm name

Alarms
Settings

Disconnect

Alarm time

DC ON

Battery
Settings

Alarm Type
Level
Relate Relay
DI No.
Mode
Set DI Name
Audible alarm
Clear Hist Alarm
Block Alarm

--See Figure 2

Alarm serial No.

Rectifier

AC ON

Alarm name

AC OFF

Start time
End time

AC
Settings

Reset

OverVolt
LowVolt

280V
180V

UnderVolt
AC Input

None

Over Volt alarm

DC OFF
Alarm
History

Alarm
Type

BC
Test

DC on/off
Curr Limit

Active
Alarm

Settings

58.5V

None

Low Volt alarm

45.0V

AMB.Temp High Alarm 40


AMB.Temp Low Alarm -5

DC
Settings

45.0V

Under Volt alarm

Load Shunt

2.

Operator level authority is compatible with user level


authority. Administrator level authority is compatible
with operator level authority.

3.

Parameters on the right side are default values set


before delivery.

Rectifier
Settings

Walk-in Time

"Status" information can be queried only. Refer to


Figure 2 for system information.

None

Walk-in Enabled

Note:

8s

Rect Over Volt


Default Volt

53.5V

59V
30A

Curr In Lim
Fan Speed

Half Speed
300s

HVSD Time
Temp Sensor

None
35 C

Start temp 1

Stop temp 1
Start temp 2

30 C

Stop temp 2
No AC fan off

40 C
Yes

45 C

Fan
Settings

1.

None

Shunt Coeff

Address
Text
User level

1
Chinese

Comm Mode

RS232

BaudRate

9600bps

Set Date
System
Settings

Set Time
Operator
level
Administrator
level

Figure 1

Menu structure of the monitoring module (1)

Init PWD

Init Param

System Type

48V/30A/300/NONE

Change Password
Con Alarm voice

Constant

53

Appendix 3

Menu Structure Of The Monitoring Module

Battery Settings

Batt.
Selection

System information
Mode
Batt String
Capacity

Auto
4

AC voltage
DC voltage

300Ah

System
operation
state

Batt Name
Batt Shunt1

Batt Shunt2

LLVD Enable

BLVD Enable
LVD Mode
LLVD Volt
BLVD Volt
LLVD Time

Y
Voltage
44.0V
43.2V
300min

BLVD Time

LVD
Setting

Power
management
mode

600min

Battery
state

AUTO
MANUAL
FC
BC
Temperature compensation
Cyclic Boost
Test
Short test
Scheduled test

Float charge
Boost charge
Current limit
Over current point

56.4V
0.1C10
0.15C10

Automatic Boost
Charge

Normal
Alarm
Battery
manageme
nt mode

Cyclic Boost
To Boost capacity
To Boost current
Constant BC Current

Y
80%
0.06C10
0.01C10

53.5V

Battery1 current
Battery1 remaining capacity
Battery2 current
Battery2 remaining capacity
AC voltage
System Power
Cyc BC After
Bat. Temp
Amb. Temp

Duration of constanct BC 180min


Cyclic Boost Interval
2400h

Note:

Cyclic Boost Time


Boost Limit

1. System information is queried in system


information page.

Battery test volt.

720min
1080min

2.

Battery test time


Test end Cap
Scheduled Test

0.7C10
N

Planned Test1

00:00, Jan.1st

Planned Test2
Batt. Test

45.2V
300min

00:00, April1st
st

Planned Test3

00:00, July1

Planned Test4
ShortTest Enable
Alarm Current
ShortTest Cycle
ShortTest Duration

3. Basic parameters should be reset according to


actual configuration.
4. Parameters on the right side are default values
set before delivery.

00:00, Oct.1st
Y
10A
720h

StableTest Enable
StableTest Current

5min
N
9999A

Temperature1
Temperature2

Ambient Temp
Battery Temp

Center Temp
Temp Comp

25

Over Temp alarm


High Temp alarm

50
50

Low Temp alarm

72mv/

2
2

Temp
Comp

Press ESC at system information page, you can


query the serial number and software version of
the monitoring module.

54

Figure 2 Menu structure of the monitoring module (2)