Você está na página 1de 5

Measurement Technology HMS 990 USB

Brochure







Reinforcement for Star Diagnosis compact
4


HMS 990 USB Measurement Technology is the ideal enhancement for the diagnosis capabilities
of Star Diagnosis compact
4
. The combination of these two powerful devices allows service
technicians to thoroughly check a vehicle in every detail. HMS 990 USB Measurement
Technology can be used immediately on Star Diagnosis compact
4
without any additional
hardware installation. One great advantage is the direct link between the diagnosis applications
Xentry Diagnostics (from model series 204) and DAS and the Measurement Technology
software. If required, the universal oscilloscope can be called up directly from the diagnosis test
procedure. Here, the measurement channel parameters are preset and a pass image is
displayed.


Extensive measuring options The electrical system

Service technicians can carry out a wide range of measurements on the vehicles electrical
system. Various voltages, ignition and dwell angles all the essential values can checked. The
equipment can even be used to check whether all the alternator values are OK. The multimeter
provides the opportunity to accurately check the basic electrical parameters such as voltage,
current, resistance, frequency, temperature, and pressure. With this range of capabilities, the
service technician always has a grip on that most sensitive vehicle component the electrical
system.


Thorough examination

The ignition rating must always be adjusted perfectly for the engine to give its best performance.
HMS 990 USB Measurement Technology offers the service technician many means for checking
the ignition ratings and to indicate variances. Service technicians can thus take the results of
measurements as their basis for assessing whether the data displayed is OK, or whether it has to
be corrected.









Are things running smoothly ? -- Analysis
of individual cylinders

Is the engine running as it should ? HMS 990 USB
Measurement Technology makes it possible to check
the duration of combustion by analyzing individual
cylinders. Compression and rotational speed are also
always in check. The service technician is
immediately notified of deviations from the specified
values.

Signal measurements with oscilloscopes
Service technicians use the universal oscilloscope and the 12-channel oscilloscope to measure
various signals such as those from the crankshaft position sensor or the camshaft Hall sensor.
Recording can extend over several minutes. The service technician can store the measurements
taken with the recorder function and retrieve them at a later point. HMS 990 USB Measurement
Technology also offers numerous possibilities for the evalulation of the values measured.

Product Information
Applications

This equipment has been exclusively
designed for the Star Diagnosis
compact
4
. It cannot be connected
to the Star Diagnosis basic
2
.

Multimeter function
Universal, 12-channel and
ignition oscilloscope
Engine test
Sensor input

Components
The portable HMS 990 USB Measurement Technology is supplied as a stand-along device. The
housing is protected by a sturdy rubber jacket. The device is operated via a USB 2.0 interface.
Power supply unit with country-specific connector cable
Battery cable set
Measurement Technology cable set
HMS 990 USB activation CD
HMS 990 USB user guide
Connections

Voltage, resistance, diode and
frequency measurements
Ground
Current measurements; direct 1
amp; electronically fused. Fuse
is automatically activated after
a failure
Connections for both universal
and 12-channel oscilloscopes
Sensor interface for general
engine test functions
Contract term
Contract term and support services are always bound
to those of the associated Star Diagnosis compact
4

system

Languages
The HMS 990 USB interface is available in all Star
Diagnosis system languages.

Permanent help and support
The Star Diagnosis User Help Desk gives advice on
the software and hardware
Competent advice in the following languages: German,
English, French, Spanish, Italian and Japanese




Mercedes-Benz Canada May 2010


Daimler AG
GSP/OI
D-70546 Stuttgart
Measurement Technology HMS 990 USB
Software Release 5.0.0
Page 1 of 3

New functionalities in the Measurement Technology
Software-Release 5.0.0


Overview
To meet the current requirements on vehicle diagnosis, additional functionalities have been added to the software for the HMS
990 USB measurement technology. These innovations enable the service personnel to an easier assessment of complex signals
and the technical hotline is given better possibilities to support and solve problems.
All the new functionalities will be explained to the user during the guided test. No special training is therefore necessary.
The software release 5.0.0 is available in the markets since Star Diagnosis Update 11/09.


New functionalities:
Signal measurement .......................................................................................................................................................................1
Storage of series of measurements................................................................................................................................................1
Storage of images...........................................................................................................................................................................2
Current clamps measuring range ...................................................................................................................................................2
Measurement of the start of delivery .............................................................................................................................................3


Signal measurement
With the new software release, amplitudes and
times can be measured directly including
automatic conversion to frequency. In addition,
all signals can be analyzed with a freely
selectable reference base (100%, 360, 720).















Storage of series of measurements
This functionality enables the service personnel
to save, archive and reload complete series of
measurements. This means that in the event of
an error, the technical hotline can assess the
situation more easily and provide better
support.
Delta measurement
channel A Y2 Y1
channel B Y2 Y1
active cursor
Measuring range
Signal measurement


Daimler AG
GSP/OI
D-70546 Stuttgart
Measurement Technology HMS 990 USB
Software Release 5.0.0
Page 2 of 3


Storage of images
Individual images can now be stored directly as
a bmp or gif image file.




















Current clamps measuring range
New measuring ranges (10 mV/A, KR 015,
100mV/A) have been included for current
clamps.


Display settings
window size
start maximized
enlargeable
adjust size
Control key F4
output target
standard printer
File parameters
Target Directory
basic file name running number
Measuring range
Measurement signal
voltage
current
resistance
frequency
temperature
pressure
diode test


Daimler AG
GSP/OI
D-70546 Stuttgart
Measurement Technology HMS 990 USB
Software Release 5.0.0
Page 3 of 3


Measurement of the start of delivery
The measurement of the start of delivery
according to the governor impulse method can
now be applied in full thanks to a new method
using the existing adapter.

Você também pode gostar