Optima PT/VS/ST
PERFORMANCES
Flow rate range 1 to 1000 ml/h in normal mode (or up to 1500 ml/h***), 1 ml/h increment 0.1 to 100 ml/h in micro-infusion mode.
0.1 to 100 ml/h in micro-infusion mode, 0.1 ml/h increment.
Flow rate accuracy 5% with the recommended sets.
Volume range 1 to 9999 ml in normal mode (1 ml increment),
0.1 to 999.9 ml in micro-infusion mode (0.1 ml increment).
Infusion time Adjustable from 1 minute to 96 hours, 1 min increment.
Setting Modes Flow rate only, ow rate + volume, volume / time, ow rate + time, ramp-up / ramp-down,
primary / secondary, sequential, bolus, induction / loading dose, micro-infusion.
OCS (Occlusivity Check System)** The OCS test is the only auto-test to check the good working order of the pump in association with its set and thus
preventing all risks of free ow.
KVO rate 3 ml/h, adjustable.
Pressure limit 750 mmHg, adjustable from 100 to 900 mmHg (50 mmHg increment).
Pause function Adjustable from 1 min to 24 h.
History Data log Up to 764 last dated events.
Congurations infusion modes (micro or macro-infusion, ramp-up / ramp-down, sequential, induction, bolus,
primary / secondary), key board lock, KVO, pressure limit, display of drug name, time
and hour setting, language, LCD contrast, alarm sound level, ward name, secrete code, max.
allowable ow rate, air bubble size, recall of last parameters at power ON, display mode,
volume cumulating, end of infusion pre-alarm setting.
RS232 Connection Bi-directional connection.
Nurse call Outlet for alarm report.
SAFETY AND FEATURES ALARMS
Air detection Set at 250 l over the last 15 minutes, adjustable.
Protections against free ow Check of pump + set occlusivity (OCS test** or Drop sensor*)
Checks of line OCS test**, door open, set positioning, set installation, downstream occlusion, upstream occlusion, line disconnection.
Checks of infusion End of infusion warning, end of infusion, empty container, ow error, unconrmed setting, end of pause.
Checks of device OCS test**, door open, mains power disconnection, lowbattery, empty battery, technical fault, auto-test, motor rotation.
Detection of occlusions Downstream and upstream.
DPS (Dynamic Pressure System) Detection of pressure variations in the line (increase, decrease) allowing both a faster occlusion, or a line disconnection.
Anti-bolus System Automatic bolus reduction at occlusion release.
Keyboard lock Protection against change of setting.
TECHNICAL SPECIFICATIONS
Pumping mechanism Second generation linear wave peristaltic system, controlled by an intelligent software ensures a constant and precise owrate.
Dimensions / Weight W=17.5, H=13.5, D=14.5 cm / 2,9 kg.
Power supply 100-240 V ~ / 50-60 Hz.
Battery Features: 6 V 2.7/3 Ah - NiMH, Charging time: 5 hours device OFF, 16 hours device ON.
Battery life 5h30 in average at 125 ml/h.
Drop detector Use in option for an empty bottle detection.
Housing In PC ABS HF, designed to reduce liquid ingress and facilitate the cleaning.
(*) Indicates available features.
Optima PT* using PVC-sets, with drop sensor.
Optima VS** using PVC-sets, with OCS test.
Optima ST*** using SILICONE-sets, with drop sensor.
Due to our policy of continuous product development as well as changes in standards, the features described are subject to change. Please contact us for current situation.
Manufacturer
Fresenius Vial S.A.S
Le Grand Chemin
38590 Brzins
France
Tel: +33 (0)4 76 67 10 10
Fax: +33 (0)4 76 67 11 34
A Company of Fresenius Kabi www.fresenius-kabi.com
Optima PT/VS/ST
VOLUMETRIC INFUSION PUMP
Easy learning,
thanks to explicit
symbols.
Straightforward infusion settings,
with direct calculation
of volume/time.
Clarity of display:
operating and ow LEDs,
visible at 5 m.
OPTIMA
offers
you
more
> The OCS (Occlusion Check System)**
is the patented
(1)
auto-test to check the correct working
order of the pump in association with its tubing set thus
preventing any risk of free ow.
(1)
Patent N EP 103 135 8 A1
> An extensive range of setting modes to
meet all infusion protocols, from the simplest to the
most specic.
> The unit is designed to facilitate
maintenance and limit the risk of
ooding the pump.
Non exhaustive table. These tubing sets are also compatible
with the Orchestra Module MVP PT.
For other sets, please consult us.
Ease of use
> Dynamic pressure monitoring system, DPS,
alerts via audible or light alarms, upon detection
of any variation in pressure due to the onset
of an occlusion, leak, or disconnection.
> The 2nd generation peristaltic system,
controlled by intelligent software, ensures
a constant and precise ow rate.
i
n
f
u
d
r
o
p
i
n
f
u
d
r
o
p

R
P
Y
i
n
t
r
a
d
r
o
p

d
i
a
b
o
l
o
i
n
t
r
a
d
r
o
p

R
V
S
V
S
_
1
0
V
S
_
7
0
O
P
_
V
S
Fast positioning
of the tubing set.
EXTENSIVE CHOICE
OF TUBING SETS
A volumetric
pump,
well suited
to any care unit,
that focuses on
essentials: security
and ease of use
> General wards
> Intensive care
> Neonatal care
> Oncology
> Cardiology
> Post-operative care
> Paediatric care
> Maternity
> Home care
> ...