Você está na página 1de 3

M

O
D
.
E
L
E
.
C
B
L
.
0
1
0
/
4
S
h
.
0
1
/
0
3
This document is Company property. The Company lawfully reserves all rights.
Unit
Agip
Sheet / of Compiled Date
Doc.n
/
COMPANY
Job
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
DATA SHEET FOR SUBMARINE ELECTRICAL CABLE
LOCATION DATA
CABLE CONNECTION
FIRST CABLEHEAD
SECOND CABLEHEAD
Platform - platform
Platform - land
Denomination:
Coordinates:
Sea depth (1) : m
Denomination:
Coordinates:
Sea depth (1) : m
SYSTEM PROJECT DATA
Distance between cableheads :
Note : for enviromental conditions see data sheet
Operating voltage :
Frequency :
Neutral wire :
Max. continuous load :
Overload due to big motor start-up :
Voltage drop : with continuous load
at big motor start-up
Max. fault level :
Max. duration of one phase earthed :
Exposure to overvoltage due to atmospheric impulse :
CABLE LAYING CONDITIONS
Max. radius of bending:
Max. tensible strenght:
Min. seabed burial depth:
NOTES : (1)
m
To earth through resistor
Kv %
% Hz
To earth Insulated
KVA
KVA
%
%
KA
1 hour 8 hours
No Yes
m
N
m
Description Rev. Prep'd Chk'd Appr'd Date
0
Write 0 if a cablehead is on land














































M
O
D
.
E
L
E
.
C
B
L
.
0
1
0
/
4
S
h
.
0
2
/
0
3
This document is Company property. The Company lawfully reserves all rights.
Dept
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job
AREA
COUNTRY
PLANT
Revision
0
INTERNAL NORMALIZATION
DATA SHEET FOR SUBMARINE ELECTRICAL CABLE
CONSTRUCTION DATA
Manufacturer and construction type :
Reference specifications :
N x nominal area of conductors :
Nominal voltage (Uo/U) :
Protective conductor :
Nominal total quantity :
LENGHTS QUANTITY PER
NOMINAL LENGHT
n x m
n x m
n x m
n x m
n x m
mm
Kv
m
Yes No
m
m
m
m
m
CONDUCTOR
SEMICONDUC.
LAYER
INSULATION
SEMICONDUC.
LAYER
METALLIC
SHIELD
Material
Class (2)
N core x diam. n x mm
Diameter (3)
Mass (3)
Material
Thickness mm
Material
Thickness mm
Diameter (3) mm
Mass (3)
mm
Kg/Km
Kg/Km
Material
Thickness mm
Material
Tape thickness mm
mm
FILLERS
Material
Material
BEDDING
Thickness
Mass Kg/Km
mm
ARMOURING
Wire material
No. core x diam. n x mm
Spiral step mm
Min. overlap
Mass Kg/Km
SECOND
ARMOURING
Expected
Spiral direction as the first
Expected
Material
Thickness
OVERALL
SERVING
Yes No
Yes
Yes
No
No
Total overall diameter:
Total cable mass in air:
Total cable mass in water:
mm
Kg/Km
Kg/Km
NOTE : (2) - Class 1 : Solid conductor - (U).
Class 2 : Stranded conductor circular (R) shaped (S).
Class 5 : Flexible conductor (F)
Class 2 : Highly flexible conductor (H) or (FF)
(3) - Only for single core conductors without outer sheathing.





















































M
O
D
.
E
L
E
.
C
B
L
.
0
1
0
/
4
S
h
.
0
3
/
0
3
This document is Company property. The Company lawfully reserves all rights.
Dept
Agip
Sheet / of Compiled Date
Doc. n
/
COMPANY
Job
AREA
COUNTRY
PLANT
Revision
0
DATA SHEET FOR SUBMARINE ELECTRICAL CABLE
CONSTRUCTION DATA
External serving colour (4) :
Cores identification (5) :
Max. operating temperature (5) :
Power frequency test voltage/Impulse withstand voltage (Up)
Coefficient K : for conductors
NOTES : NE - Black, GR -Grey, RO - Red, BI - White, GI - Yellow.
N+n - Black and progressive numbering, N - Black, M - Brown, B - Light blue, G/V - Yellow/Green
Rating current in air at 30 C:
Rating current in J-tube at 30 C:
Rating current in ground at 20 C:
Rating current in sea water at 16 C:
Phase reactance at Hz :
Min. insulating resistance at 20 C:
Min. insulating resistance at 50 C:
Phase capacity :
:
REEL CHARACTERISTICS
With armour :
without armour :
C - Final short circuit temperature C
/ Kv
- for screen or metallic sheaths
A.C. phase-reactance at the max. operating temperature :
A
A
A
A
Ohm/Km
Ohm/Km
mOhm/Km
mOhm/Km
microF/Km
Reel N
Diameter
Width
Drum mass
Gross mass
m
m
Kg
Kg
m
m
MINIMUM RADIUS
OF BENDING
(4)
(5)
INTERNAL NORMALIZATION
A s / mm A s / mm

Você também pode gostar