tise gained over the past 25 years of experience in hundreds of polymer activation
applications across a wide spectrum of industrial and municipal environments.
The VortiBlend Series fills the need for a reliable, low maintenance, economical,
high performance liquid polymer activation system that is simple to operate. Our
approach to the commercial aspects (Money Back Guarantee) makes it easy for
our clients to invest in this technology without risk.
The Tertiary mixing stage optimizes the hydration process and associ-
ated Charge Site Exposure with tapered cyclonic energy agitation prior
to discharge from the unit.
Operational Sequence
The VortiBlend operation is simple. First , the user enters the desired polymer concentration via a touch pad controller
and selects manual or automatic operation. Primary dilution water flow is controlled by a solenoid valve which allows
water to enter the unit.
Primary dilution water flow rate data is measured continuously to assure that adequate flow is present and fed back to
the system PDC-1 control unit. Using calculations derived from the calibration stage, the unit automatically adjusts the
polymer pump output to achieve the desired concentration.
Under conditions of high or low concentration, a loss of water flow or polymer feed (optional) the system automatically
shuts down and notifies with an alarm. Each feed cycle is followed by an adjustable, multi-stage flush cycle to eliminate
any plugging . The system can be operated remote via a 4-40mA or simple on/off signal.
A secondary dilution module can be added for applications requiring post dilution.
1450 W. Fullerton Avenue ♦ Addison, Illinois 60101 ♦ Phone: 630.543.1911 ♦ Fax : 630.543.2089 ♦ www.chemflow.com
VortiBlend System Features & General Specifications
• Reliable The PDC-1 paces the polymer metering pump based operator pro-
grammed data or based on a 4-20mA input signal.
• The NEMA 4X control box provides protection from dust, rain, and hose directed water.
Is this sufficient? (some applications require hazardous or special approvals)
• Is the location for the equipment level and of sufficient space (6X6 feet) to allow for
safe and easy access to the system for maintenance? (allow additional space for tanks)
• Can the system be located in a well lit area protected from direct sunlight where the
ambient temperature is between 40 and 110 º F?
• Can the feeder be located within 10 feet (horizontal) of the chemical supply, no lower
than 10 feet below the polymer tank to ensure flooded suction without creating
excessive pump inlet pressure, or no higher than 3 feet above the tank so that the
pump has no more than 3 feet of suction lift?
• Has a suitable route for the solution discharge line been surveyed and measured?
• If the solution is being directly fed to the process is the injection point pressure at least
30 PSI less than the water supply pressure?
• Have the suction and discharge lines been suitably sized for viscous fluids?
• Is the water supply meet the systems dilution flow rate at minimum pressure of 30 PSI
and at least 30 PSI higher than the polymer injection point at a temperature between
50-80º F?
• If the water has excessive particulates has a basket strainer been installed? (y-strainer
on system will quickly load if particulate is too high)
We have designed and manufactured liquid polymer blending equipment for over thirty years and
thousands of installations. Our equipment is sold under the Chem-Flow brand as well as private
labeled for a large number of chemical suppliers and OEMs.
Chem-Flow has the financial strength and application expertise to meet or exceed any require-
ments relating to the experience or stability of a equipment manufacturer or system integrator.
Our team routinely engages in the field start up and training of plant personnel and typically
achieves the highest ratings given by attendees regarding the type and level of the training and
support.
Chem-Flow has supplied polymer feeders to some of the most prestigious customers in a variety
of industries for process critical application of polymer activation.
Our purpose is to exceed our client’s pre-defined requirements or assist our them to identify the
proper equipment and controls required to maximize their investment in treatment chemicals.
Our 47 years of application experience and understanding of the latest technologies allows us to
provide a high level of customer support before, during and after the delivery of our systems.