Layher Allround - Description and Technical Specification.doc 23/05/2008, Bb.
Layher ALLROUND
Description and Technical Specification
Description system scaffold, modular, ring system rosettes (rings) with 4 big and 4 small holes distance of rosettes: 500mm up to 8 connections in one plane automatic right-angles or flexible angle selection wedge connection approved connection with verified load bearing capacities bolt-free connection technology durable protection against corrosion by hot-dip galvanisation also in cavities and on edges thickness of zinc layer: 60-80m maintenance-free versatile applications as birdcage scaffold, tower scaffold, faade scaffold, service scaffold, falsework, supporting scaffold, suspended scaffold, stair tower or mobile scaffold
Technical specifications (excerpt) tubes for verticals (standards) and horizontal elements (ledgers) have the following properties: Standard DIN EN 10 219-1:2006-07 Outside Diameter [mm] 48.3 Wall Thickness [mm] 3.2 Yield Stress [N/mm 2 ] 320 all components are permanently marked among others with Layher, month and year of production
Design load bearing capacities (K 2000+) of the wedge head connection (permissible loads are obtained by dividing the given values by F =1,5) Bending moment [kNcm]
M y,R,d
101 kNcm Normal force [kN]
N R,d
31,0 kN Vertical shear force [kN]
V Z,R,d
26,4 kN Diagonal force [kN]
N V,R,d
Tension: +17,9 kN
Compression*: -16,6 kN N V,R,d -5,3 kN
*depending on the length of the diagonal brace
page 2 of 3 Layher Allround - Description and Technical Specification.doc 23/05/2008, Bb.
Permissible vertical load for a standard 2,0m lift: up to 45 kN 1,5m lift: up to 60 kN 1,0m lift: up to 70 kN
Permissible vertical load for an adjustable base plate: up to 61 kN (Base plates with a permissible vertical load up to 172,6 kN are available.)
Permissible tensile force for a standard (steel version) with a bolted spigot: 55,9 kN
Maximum bay length: 4,144m Layher nominal bay width - effective deck width Layher nominal bay width [mm] 732 1088 1400 1572 2072 2572 3072 Number of steel decks 2x 0,32m 3x 0,32m 4x 0,32m 4x 0,32m + 1x 0,19m 6x 0,32m 7x 0,32m + 1x 0,19m 9x 0,32m Effective deck width [mm] 640 960 1280 1472 1920 2432 2880
Load classes according to EN 12811-1: Service loads on working areas
Guardrail height (for O-system): 99cm Toeboard height: 15cm Weight of standard components: less than 19kg per item (Exception: Steel deck 0,32 x 3,07m and access decks with integrated ladder) Access by ladder, total width: 350mm (aluminium version), 340mm (steel version), step width: 300mm, rung spacing: 280mm Access by aluminium platform stair, total width: 637mm, step width: 555mm, step spacing: 200mm, permissible live load: evenly distributed load of 2,0 kN/m 2 ; maximum load on an area of 0,2m x 0,2m: 1,5kN single load Permissible load for a Layher double coupler: 9,1 kN
page 3 of 3 Layher Allround - Description and Technical Specification.doc 23/05/2008, Bb.
European standards
EN 12810-1 Facade scaffolds made of prefabricated components. Product specifications
EN 12810-2 Facade scaffolds made of prefabricated components. Particular methods of structural design
EN 12811-1 Temporary works equipment. Scaffolds. Performance requirements and general design
EN 12811-2 Temporary works equipment. Information on materials
EN 12811-3 Temporary works equipment. Load testing
EN 12812 Falsework. Performance requirements and general design
EN 10219-1 Cold formed welded structural hollow sections of non-alloy and fine grain steels. Technical delivery requirements
EN 10219-2 Cold formed welded structural hollow sections of non-alloy and fine grain steels. Tolerances, dimensions and sectional properties
EN 10025-2 Hot rolled products of structural steels. Technical delivery conditions for non-alloy structural steels
EN 10204 Metallic materials. Types of inspection documents
EN ISO 1461 Hot dip galvanized coatings on fabricated iron and steel articles. Specifications and test methods
EN 74-1 Couplers, spigot pins and baseplates for use in falsework and scaffolds. Couplers for tubes. Requirements and test procedures
EN 755-1 Aluminium and aluminium alloys. Extruded rod/bar, tube and profiles. Technical conditions for inspection and delivery
EN 755-2 Aluminium and aluminium alloys. Extruded rod/bar, tube and profiles. Mechanical properties