Você está na página 1de 5

1

300 kW electric power station components: commercial offer


The current document contains description and pricing of components for an electric power
station, including a steam turbine with a generator and 300 kW electrical output and a high-
pressure steam boiler.
Our services, according to the predetermined price, also include designing and planning
works, as well as installation and adjustment. Yet they do not include shipment which will be billed
later, for it requires more detailed calculations.
We pay your attention that the current offer includes only the necessary components and
services in order to give you a better price.
Steam Turbine Specification
-0.3-1.3/ 0.12 steam turbine (ST) is a one-cylinder unit with a bilateral pressure stage.
Figure 1
ST is enabled with a nozzle steam distribution. Input steam is delivered to the steam chamber
located in the upper part of the cylinder and contains a stop valve and control valves from where
steam moves to the bilateral stage.
2
The anchor point of ST is attached to the body of its front bearing.
The turbine is provided with both terminal and diaphragm labyrinth steam packings. The
steam-air mass is pumped off from end compartments to the steam condenser. The second packing
chamber (next to the machine room) is filled with consolidated steam at 1.2 kgf/ cm pressure.
ST rotates the GSV-280-S-4 electric generator with the nominal power of 320kW (a similar
model is displayed at Figure 2).
Figure 2
ST is supplied by the electric control system. The changing of control valves inputting fresh
steam is performed by servomotors on electric drives.
ST oil system is fed by T 22 oil (GOST 32-34) used for oiling bearings at 0.15 Mpa (1.5
kgf/ cm) pressure. Using TP-22 (GOST 9972-74) or similar oils is acceptable.
ST is supplied by an oil pump, which is all at once a start and standby oil pump. At nominal
rotation speed oil is delivered to oiling system by the pump located on the rotor shaft. At ST start oil
delivering is performed by a detached electrical pump unit. Oil streams to the system by passing the
reduction valve.
ST control system assures the automatic start of the standby oil pump and emergency ST
shutdown at lowering the oil pressure level in the system.
Scheme of Components
Figure 3
3
Steam Boiler (prospective) by Biysk Boiler Factory:
Figure 4
Extra control and automation features
ST can be also supplied with a complex control and safety system that will allow to run and
control most of the units automatically. Those features are considered to be extra and are priced
separately.
ST control and safety system guarantees:
24/ 7 control of all parameters and functions;
registration of crucial parameters;
technological, precautionary and emergency alarm;
manual remote and automatic control, including system blocking, starting standby capacities
and stabilizing a number of parameters;
automatic ST protection
remote control of key parameters via Internet
4
Technical characteristics and comparison of steam turbines
The current chapter depicts the technical parameters of -0.3-1.3/ 0.12 turbine.
In the table below you can also see the advantages of -0.3-1.3/ 0.12 as compared with a turbine
with higher parameters.
Table 1
As comparing the characteristics of the two steam turbines, we have come to the following
conclusions:
1. Increasing the pressure of fresh steam at turbine input demands a significant increase of
stages number, and thus results in significant increase of total installation price.
2. Increasing the temperature of fresh steam at turbine input requires significantly more
expensive materials.
3. Above all, -0.3-1.3/ 0.12 gains its 55% efficiency, so its no need to elaborate a more
complex and expensive solution to reach the maximum of productivity.
At this point, we recommend -0.3-1.3/ 0.12 as the most reasonable solution considering both price
and efficiency.
PARAMETERS VALUES
Turbine Type -0.3-1.3/ 0.12 -0.3-3.9/ 0.12
Parameters of input steam at stopvalve:
nominal pressure, kgf/ cm2 (abs)
nominal temperature,
0

nominal consumption, tons/ hour


13
225
5.2
39
450
3.7
Parameters of output steam:
nominal pressure, kgf/ cm2 (abs) 1.2 1.2
Rotor speed:
turbine rotor, r/ min
generator rotor, r/ min
7500
1500
7500
1500
Number of stages 1 bilateral 1 control +5 pressure stages
Turbine setting efficiency, % 63 58
Generator efficiency, % 92.5 92.5
Installation efficiency, % 55 55
Electrical power at generator terminal, kW 300 300
5
Components Price
Table 2
# Position Manufacturer Quantity Approximate
Price (prospective)
MACHINE ROOM
1. Steam turbine-0.3-1.3/ 0.12 ZAO "Energoteh" 1 252733
BOILER ROOM
2. Steam boiler OAO "BiKZ" 1 66 860
3. Feed pump OAO "Kataisky Zavod" 1 3 779
FUEL FEED AND STORAGE
4. Drag-type conveyor OAO "VOMZ" 1 3 198
5. Screw conveyor OAO"VOMZ" 2 2 326
6. Middle storage bunker package 1 2 907
7. Boiler bunkers package 2 1744
WORKS
8. Complete designand planning works 35174
9. Installation, starting-up and adjustment 6 395
TOTAL 375 116
Please note, that prices above are for a one-of-a-kind order. All the subsequent devices are
sold at 7-12% discount.
Waiting for mutually advantageous
and fruitful cooperation.
Sincerely yours,
Denn Y. Sviridov
Standard Service
Marketing Director

Você também pode gostar