Você está na página 1de 200

Core and Cavity Design

User's Guide
Version 5 Release 16




1 Page
Core and Cavity Design Version 5 Release 16
Special Notices
CATIA is a registered trademark of Dassault Systmes.
Protected by one or more U.S. Patents number 5,615,321; 5,774,111; 5,821,941; 5,844,566; 6,233,351;
6,292,190; 6,360,357; 6,396,522; 6,459,441; 6,499,040; 6,545,680; 6,573,896; 6,597,382; 6,654,011;
6,654,027; 6,717,597; 6,745,100; 6,762,778; 6,828,974 other patents pending.
DELMIA is a registered trademark of Dassault Systmes.
ENOVIA is a registered trademark of Dassault Systmes.
SMARTEAM is a registered trademark of SmarTeam Corporation Ltd.

Any of the following terms may be used in this publication. These terms are trademarks of:
Java Sun Microsystems Computer Company
OLE, VBScript for Windows, Visual Basic Microsoft Corporation
IMSpost Intelligent Manufacturing Software, Inc.
All other company names and product names mentioned are the property of their respective owners.
Certain portions of this product contain elements subject to copyright owned by the following entities:
Copyright Dassault Systemes
Copyright Dassault Systemes of America
Copyright D-Cubed Ltd., 1997-2000
Copyright ITI 1997-2000
Copyright Cenit 1997-2000
Copyright Mental Images Gmbh & Co KG, Berlin/Germany 1986-2000
Copyright Distrim2 Lda, 2000
Copyright Institut National de Recherche en Informatique et en Automatique (INRIA
Copyright Compaq Computer Corporation
Copyright Boeing Company
Copyright IONA Technologies PLC
Copyright Intelligent Manufacturing Software, Inc., 2000
Copyright SmarTeam Corporation Ltd
Copyright Xerox Engineering Systems
Copyright Bitstream Inc.
Copyright IBM Corp.
Copyright Silicon Graphics Inc.
Copyright Installshield Software Corp., 1990-2000
Copyright Microsoft Corporation
Copyright Spatial Corp.
Copyright LightWork Design Limited 1995-2000
Copyright Mainsoft Corp.
Copyright NCCS 1997-2000
Copyright Weber-Moewius, D-Siegen
Copyright Geometric Software Solutions Company Limited, 2001
Copyright Cogito Inc.
Copyright Tech Soft America
Copyright LMS International 2000, 2001
2 Page
Core and Cavity Design Version 5 Release 16
Raster Imaging Technology copyrighted by Snowbound Software Corporation 1993-2001
CAM-POST Version 2001/14.0 ICAM Technologies Corporation 1984-2001. All rights reserved
The 2D/2.5D Display analysis function, the MSC.Nastran interface and the ANSYS interface are based on LMS
International technologies and have been developed by LMS International
ImpactXoft, IX Functional Modeling, IX Development, IX, IX Design, IXSPeeD, IX Speed Connector, IX Advanced
Rendering, IX Interoperability Package, ImpactXoft Solver are trademarks of ImpactXoft. Copyright 2001-
2002 ImpactXoft. All rights reserved.
This software contains portions of Lattice Technology, Inc. software. Copyright 1997-2004 Lattice
Technology, Inc. All Rights Reserved.
Copyright 2005, Dassault Systmes. All rights reserved.
3 Page
Core and Cavity Design Version 5 Release 16
Core & Cavity Design
Overview
What's New?
Getting Started
Importing the Molded Part
Defining the Main Pulling Direction
Defining a Direction for the Slider
User Tasks
Importing a Model
Defining the Main Pulling Direction
Defining the Main Pulling Direction with No Draft
Pulling Direction for Sliders
Comparing Two Molded Parts
Explode View
Transferring Elements
Splitting a Face
Creating a Parting Surface
Aggregating Surfaces
Smooth Edges
Surface Boundaries
Face Orientation
Bounding Box
Sectioning
About Sectioning
Creating Section Planes
Creating 3D Section Cuts
Manipulating Planes Directly
Positioning Planes On a Geometric Target
Positioning Planes Using the Edit Position and Dimensions Command
More About the Section Viewer
Performing a Surfacic Curvature Analysis
Workbench Description
Menu Bar Description
Tool Bar Description
Import Part
Pulling Direction
Parting Line
Wireframe
Parting Surface
Operations
4 Page
Core and Cavity Design Version 5 Release 16
Advanced Replication Tools
Annotations
Specifications Tree
Reference Information
Import Model Parameters
Pulling Direction Parameters
Slider Lifter Direction Parameters
Transfer an Element Parameters
Compare Models Parameters
Split Mold Area Parameters
Face Orientation Parameters
Bounding Box
Glossary
Index
5 Page
Core and Cavity Design Version 5 Release 16
Overview
Welcome to the Core and Cavity Design User's Guide!
This guide is intended for users who need to become quickly familiar with the product.
This overview provides the following information:
G Core and Cavity Design in a Nutshell
G Before Reading this Guide
G Getting the Most Out of this Guide
G Accessing Sample Documents
G Conventions Used in this Guide
Core and Cavity Design in a Nutshell
Core and Cavity Design is intended for:
G a quick analysis of a molded part (cost feasibility),
G the preparation of the molded part for mold design and mold manufacturing.
Core and Cavity Design defines the core and cavity sides of a part, including any sliders or lifters that may be
required, so as to produce a MoldedPart ready to be used with Mold Tooling Design. It includes functions that
define:
G The pulling directions,
G the parting line
G the parting surface,
G the splitting surface,
along with analysis and fine tuning capacities.
Before Reading this Guide
Prior to reading the Core and Design User's Guide, you are recommended to have a look at the
Infrastructure User's Guide for information on the generic capabilities common to all products.


Getting the Most Out of this Guide
6 Page
Core and Cavity Design Version 5 Release 16
To make the most out of this book, we suggest that a beginning user reads the Getting Started chapter
first of all and the Workbench Description to find his way around the Core and Cavity Design workbench.
The User Tasks section gives a quick description of the operating mode of the various actions, whereas the
Reference Information section lists the parameters used in those actions.

Accessing Sample Documents
To perform the scenarios, sample documents are provided all along this documentation. For more information
about this, refer to Accessing Sample Documents in the Infrastructure User's Guide.

7 Page
Core and Cavity Design Version 5 Release 16
What's New?

8 Page
Core and Cavity Design Version 5 Release 16
Getting Started
This is a short tutorial that will help guide you through the key functionalities in the Core & Cavity
workbench. You will learn how to take a part and define its core, cavity and slider areas.

The tutorial should not take you more than 15 minutes to complete.
Importing the Molded Part
Defining the Main Pulling Direction
Defining a Direction for the Slider

9 Page
Core and Cavity Design Version 5 Release 16
Importing the Molded Part
This task shows you how to enter the Core & Cavity Design workbench and how to import a part to use
there.
Ensure that you have a product (and not a part) in the viewer.
1. Start the application with Start > Mechanical Design > Core & Cavity Design.
2. Click the Import model icon and import GettingStarted.CATPart from the samples directory.

3. Press OK.

10 Page
Core and Cavity Design Version 5 Release 16
Defining the Main Pulling Direction
This task teaches you how to define the main pulling direction which, in turn, defines the core and cavity
surfaces.
1. Click the Defines pulling direction icon .
2. Once the dialog box is open, click the part in the viewer.
11 Page
Core and Cavity Design Version 5 Release 16
The surface that you see is green because it corresponds to the cavity surface.
Turn the part over and you will see the core surface in red:
12 Page
Core and Cavity Design Version 5 Release 16
However, as you turn the part round you will notice that there is an area that is neither red
(core) nor green (cavity). This area will require another pulling direction for the slider area that
will be needed to ensure that the part can be correctly unmolded.


3. Press OK. The following elements are created in the specification tree:
G Core.1, i.e. the core area, displayed in red,
G Cavity.1, i.e. the cavity area, displayed in green,
G NoDraft_1deg.1, i.e. an area considered as vertical, giving a draft angle of 1
degree, displayed in pink,
G Other.1, i.e. an area that belongs neither to the core area nor the cavity area,
displayed in blue (walls of the hole in the pink area).
13 Page
Core and Cavity Design Version 5 Release 16
You are now going to define the slider area pulling direction.
14 Page
Core and Cavity Design Version 5 Release 16
Defining a Direction for the Slider Area
This task shows you how to define a pulling direction for a surface that is a slider area or a loose core.
1. Click the Slider Lifter Direction icon .
2. Drag the compass into the middle of the hole in the pink face so as to define the pulling axis for the
slider area like this:
15 Page
Core and Cavity Design Version 5 Release 16
You could also enter the coordinates for the direction in the dialog box like this:


The pink surface has turned yellow. If you zoom in you see the walls of the hole are still blue.
16 Page
Core and Cavity Design Version 5 Release 16
4. In the dialog box, check Locked to lock the pulling direction, check Local Transfer to activate this
functionality, in the first list, select Slider/Lifter as the destination area, in the second list select
Point continuity as the propagation type.
17 Page
Core and Cavity Design Version 5 Release 16
Pick one blue face, this will select the second as well since they are continuous.
They turn yellow since they belong now to the Slider/Lifter area.
18 Page
Core and Cavity Design Version 5 Release 16
4. Press OK. The Slider/Lifter.1 element is created. It contains the Surface.6 created from Surface.4
taken from Other.1 and Surface.5 taken from NoDraft_1deg.1.
19 Page
Core and Cavity Design Version 5 Release 16

20 Page
Core and Cavity Design Version 5 Release 16
User Tasks

They are divided in several steps:


G Importing a Model,


G Defining the pulling directions and mold areas:
H Defining the Main Pulling Direction,
H Defining the Pulling Direction for Sliders.


The following functionalities provide help for the tasks above:
G Exploding the View,
G Transferring Elements,
G Splitting a Face,
G Aggregating Surfaces,
G Creating a Parting Surface.


Quality or visualization tools are also available:
G Comparing Two Molded Parts,
G Smooth Edges,
G Surface Boundaries,
G Face Orientation,
G Sectioning,
G Performing a Surfacic Curvature Analysis.


21 Page
Core and Cavity Design Version 5 Release 16
Importing a Model
This task shows you how to open the workbench and to import a part. You can also use scaling and
affinity functions to take account of shrinkage.
More information about the parameters is available in the Import Model Parameters chapter.
Ensure that you have a product (and not a part) in the viewer.
1. Open the workbench via Start > Mechanical Design > Core & Cavity Design.

2. Click the Import model icon and choose file FilterCover.CATPart from the
samples/SliderDirection directory. Select a local axis system and enter a Scaling ratio of 1.01.
22 Page
Core and Cavity Design Version 5 Release 16

3. Press OK. The solid is imported and created in the screen and in the specification tree.
23 Page
Core and Cavity Design Version 5 Release 16
Defining the Main Pulling Direction
This task shows you how to define the main pulling direction which is used:
G to define the core-cavity separation,
G to position the molded part in the mold.
More information about the parameters is available in the Pulling Direction Parameters chapter.
Core and Cavity and undercut areas are recomputed when you modify the input of the main pulling direction.

You must have completed the chapter on importing a model before starting this one.

1. Click the Defines pulling direction icon . The dialog box is displayed. The compass is snapped automatically onto the current axis
system.

2. Click on the part in the viewer.
The visible part of the part becomes green (Cavity, oriented in the pulling direction, up to 1 degree) and if
you turn it over you will see that the underside is red (Core, oriented away from the pulling direction). Areas
that cannot be associated to either Core or Cavity areas are shown in either pink (for virtually vertical
surfaces, as here) or blue (Other, i.e. undecided cases). You can see that two faces of the hole are in pink.
After having defined the main pulling direction, you will transfer the two other faces of the hole and the
surrounding front face to Other.
24 Page
Core and Cavity Design Version 5 Release 16

3. Check Locked to lock the pulling direction.
4. Check Local Transfer and choose Other in the list.
5. Select the faces as shown.


25 Page
Core and Cavity Design Version 5 Release 16

6. Explode has become available to visually spread apart Core and Cavity areas. Enter 70 mm in the field below to define the spread. In
the exploded view, you can see the Core side in green, the Cavity side in red and the Other side in blue. Note that the Other area has
not moved: Explode takes only the Core side and the Cavity side into account.

7. Press OK. A progress bar indicates the advancement of the computation. Push the button Cancel to stop the computation, if
necessary.

An axis system is created in the specification tree, under the Axis Systems body.

Main Pulling Direction contextual menu
The Main Pulling Direction contextual menu concerns the main pulling direction that is created in the specification tree under Axis Systems as
explained above.

26 Page
Core and Cavity Design Version 5 Release 16
Definition... allows you to define the coordinates and the type of the axis system.
Edit Main Pulling Direction calls up the main pulling direction so that you can edit the parameters.
Update Main Pulling Direction allows you to update the parameters (for instance the scaling
ratio) after modification.
When there are several axis systems, you can make one of them the current one using Set as
current axis system.

Display Options
In the case of large models, some faces may not be seen and, as a result, can cause holes to appear in the core or cavity side. This occurs
when the relative size of a face is small with respect to the overall model. You can avoid this problem by changing the Pixel Culling value to
0 in Tools > Options > General > Display so that all the faces in the model are used in the pulling direction computation.

27 Page
Core and Cavity Design Version 5 Release 16
Defining the Main Pulling Direction with No Draft
The No Draft option is used to search faces that are vertical (with respect of the Draft angle) and to send them to a dedicated Geometrical
set. Usually, these faces will need to be drafted before being sent to the Mold Tooling Design application.
More Operating Mode information is available in the Basic Task Defining the Main Pulling Direction.
More information about the parameters is available in the Pulling Direction Parameters chapter.


1. In the Core and Cavity Design workbench, import the GettingStarted.CATPart using the Import model command.
2. Click the Defines pulling direction icon . The dialog box is displayed. The compass is snapped automatically onto the current
axis system. Make sure all the Areas to Extract are checked. Select the part to process. The Areas to Extract are displayed in their
corresponding color.

3. Click OK to validate and exit the dialog box. The vertical face found is sent to a dedicated Geometrical set NoDraft_xxxdeg.1, xxxdeg
being the value of the draft angle.
28 Page
Core and Cavity Design Version 5 Release 16
29 Page
Core and Cavity Design Version 5 Release 16
Defining The Pulling Direction For Slider Areas
This task shows you how to define a secondary pulling direction for surfaces that are neither core nor
cavity, in blue in the molded part.
More information about the parameters is available in the Slider Lifter Direction Parameters chapter.
Before defining a direction for a slider area, you must have defined the main pulling direction.


1. Still in the same CATProduct, click on the Defines slider lifter direction icon .
The dialog box is displayed.
30 Page
Core and Cavity Design Version 5 Release 16

2. You are going to extract the Slider/Lifter area from the blue faces.
Place the compass as shown.
3. Push the Reverse button and pick the large blue face. It turns red (it is seen as a core are).
31 Page
Core and Cavity Design Version 5 Release 16
4. Push the Switch button. The five faces turn yellow (it is seen as a lifter/slider area).


5. Press OK.
A progress bar indicates the advancement of the computation. Push the
button Cancel to stop the computation, if necessary.
32 Page
Core and Cavity Design Version 5 Release 16
An axis system is created in the specification tree, under the Axis Systems
body.
When several axis systems exist, you can make one current using its
contextual menu.
The Slider/Lifter area is now defined.

33 Page
Core and Cavity Design Version 5 Release 16
Comparing Two Molded Parts
This task shows you how to compare two molded parts and identify any geometrical differences there may
be.
Before using the Compare function, you must have a molded part open in the workbench and you must
have already performed a Main Pulling operation on it.
1. Open file FirstMoldedPart.CATPart from the samples directory and perform a Main Pulling Direction
operation on it with the default options.


2. Click the Compare icon .

3. Select NewVersionMoldedPart.CATPart in the samples directory, press the body button so
that it becomes the set of faces button (because the model we are importing is a set of
faces) and click OK.
34 Page
Core and Cavity Design Version 5 Release 16

3.
This opens another dialog box:


4. Click on Apply.
5. Uncheck the first two boxes (because we only want to see the faces that have changed between
the two versions of the model, i.e. those that are specific to the new model).
35 Page
Core and Cavity Design Version 5 Release 16


6. Press OK. Two new items have been added to the tree.
Added surfaces are the new ones that come from the new model and they
will need to be assigned to the Core, Cavity, NoDraft or Other areas.
Removed surfaces are those that have been replaced by the Added
Surfaces in the Core, Cavity, NoDraft or Other areas.
36 Page
Core and Cavity Design Version 5 Release 16

7. Hide the Core, Cavity, NoDraft, Other and Removed surfaces.
Open the Main Pulling Direction dialog box ( ) and select the Added surfaces.


8. The surfaces have been analyzed according to the main pulling direction already used for the first
model. Click OK to transfer them to the appropriate areas (core, cavity, etc.).

9. Select the Removed surfaces in the tree and delete them.
37 Page
Core and Cavity Design Version 5 Release 16
Explode View
This task allows you to explode the view of the core and cavity with the slider. This is useful to check the model for eventual
problematic surfaces.

1. In the Core and Cavity Design workbench, import the GettingStarted.CATPart using the Import model command.
2. Define the main pulling direction using the Defines pulling direction command and the pulling direction for sliders using the
Slider Lifter Direction command. Your model looks like this:


3. Click the Explode View icon . The Explode View dialog box is displayed and the view of the model is exploded.
38 Page
Core and Cavity Design Version 5 Release 16
By default, all existing pulling directions are selected, and the Explode Value is set to 10 mm.
You can select one Pulling direction by picking it in the dialog box:
That is what you get in the Main Pulling Direction.1:
39 Page
Core and Cavity Design Version 5 Release 16
That is what you get in the Slider/Lifter Direction.1:
40 Page
Core and Cavity Design Version 5 Release 16

or several:
41 Page
Core and Cavity Design Version 5 Release 16
You can increase the Explode Value as in the images above.
Use Reset to revert to the default values and initial position.
Exit the action by pushing Cancel.

42 Page
Core and Cavity Design Version 5 Release 16
Transferring Elements
This task teaches you how to transfer elements from one zone to another.
More information about the parameters is available in the Transfer an Element Parameters chapter.
You must have defined at least the main pulling direction on the part.
In the example below, we have extruded the lower edge of the large Slider/Lifter face (in yellow) to build a
surface (Extrude.1).
If, for any reason, you want to move this face to the Cavity area, you will lose the structure of Extrude.1. The
action Transfer an Element moves the face to another area without destroying the structure of any element
built on it.
43 Page
Core and Cavity Design Version 5 Release 16
1. Click the Transfer an element icon and select Cavity as the destination.

2. Pick the yellow face. It is transferred to the cavity area
44 Page
Core and Cavity Design Version 5 Release 16

There is also a contextual menu on each element listed in the dialog box that allows you to transfer elements
to the available destinations, modify or remove them.

45 Page
Core and Cavity Design Version 5 Release 16
3. Press OK.


The action Transfer an element removes the face transferred from the initial body (Slider/Lifter) and creates
one surface in the destination Geometrical set (Cavity). Since a feature (Extrude.1) points to the initial
surface, this initial surface is send to a new Geometrical set CCV_NoShow under the name TrfSurface.6 (the
surface is hidden but the structure of Extrude.1 is preserved). In the image below, we have recovered the
initial surface from the NoShow.
If no features point to the initial surface, the initial surface is deleted.
46 Page
Core and Cavity Design Version 5 Release 16
A progress bar indicates the advancement of the computation.

47 Page
Core and Cavity Design Version 5 Release 16
Splitting a Face
This task shows you how to split a face, either:
G to facilitate unmolding of the part or
G to allow a face that belongs to two different zones to be divided so that it can be placed in the right
areas (core, cavity, slider/lifter areas).
The output replaces the original face.
Split surfaces can be joined again, with the option "Simplification".
More information about the parameters is available in the Split Mold Area Parameters chapter
1. Still in the same CATProduct, hide all elements in the MoldedPart apart from the PartBody.
Make MoldedPart the Define in Work Object with its contextual menu and insert a new
Geometrical set into it with Insert > Open Body.
2. You are now going to create two lines that will define the edge of the face split. Click the Line icon
. Choose tangent to curve as line type.
For the first line:
48 Page
Core and Cavity Design Version 5 Release 16



choose this curve, this point (element 2), and this support
and press the Reverse Direction button.
Press OK to create the line.
3. Create the second line with the same support but with this point and this curve:
49 Page
Core and Cavity Design Version 5 Release 16


4. Now we are going to join the lines. Click on the Join icon . Make sure that the Check connexity
option is not active and select the two lines that you have just created.
50 Page
Core and Cavity Design Version 5 Release 16
5. Press OK.
6. In the tree, hide the PartBody and show all of the other elements in the MoldedPart.
7. You are now going to split the face with the hole with the join that you just created.
Click on the SplitMoldArea icon .
8. Select the face with the hole as the Element to Cut and the join you just created as the Cutting
Element.
Press Apply.
Select Surface.16 in the dialog box, give Slider/Lifter.1 as the destination and press the Change
Destination button. Repeat this for Surface.17 that you will send to Cavity.1.
51 Page
Core and Cavity Design Version 5 Release 16
9. Press OK.
52 Page
Core and Cavity Design Version 5 Release 16
Creating a Parting Surface
This task shows you how to create a parting surface.

1. In the Core and Cavity Design workbench, import the GettingStarted.CATPart using the Import model command.
2. Define the main pulling direction using the Defines pulling direction command.
3. Send Core.1, Other.1 and NoDraft_1deg.1 to the NoShow.
4. Create a Geometrical set and make it the Define in Work Object.
Click the Sketcher icon and select the xy plane to draw a rectangle around the part.
53 Page
Core and Cavity Design Version 5 Release 16
Exit the sketcher.
We recommend that:
G you create the sketch in a plane perpendicular to the pulling direction,
G you include the directions that will define the extrusion directions.
Note that the size of the sketch is used to control the length of the parting surfaces.
In short, the sketch is essential in the definition of the parting surfaces.
54 Page
Core and Cavity Design Version 5 Release 16

5. Click the Parting surface icon . The dialog box is displayed.
Creating a parting surface creates a surface around a portion of the outer boundary of the reference support, by extrusion.
Select Surface.3 in Cavity.1 as the Reference, i.e. the part around which you want to create parting surfaces. Once the
part is selected, all vertices located on outer boundaries are made available and are displayed as white dots.
Select two vertices to define a portion of the outer boundary as the basis of the parting surface. This portion is highlighted.
Push the Complementary button if you want to use the other portion of the outer boundary.
55 Page
Core and Cavity Design Version 5 Release 16
Now select an edge of the sketch you have created. This edge will define both the extrusion direction and the extrusion
length for the parting surface. The parting surface is computed and displayed. The Profile Definition and the Direction
Definition fields are reset, ready for creating a new parting surface.
The extrusion direction is:
G located in the plane of the sketch,
G normal to the selected edge.
The extrusion length is defined as follows:
G when the parting surface is seen in the direction of the sketch, it seems to reach it completely.
56 Page
Core and Cavity Design Version 5 Release 16

6. Now select vertices and the sketch as shown below. A parting surface is created from the portion of boundary and the
extrusion parameters defined by the sketch edge.


7. In the Extrusion list, select the parting surface you have just created and remove it.
According to your needs, you can use this menu to hide or show a parting surface, or to perform a reframe on it.

8. Now create the following parting surface:
Then the next one. Note that we have picked the sketch edge so as to redefine the extrusion direction.
57 Page
Core and Cavity Design Version 5 Release 16
Now, place the cursor in the Reference field and select Extrude.2 as the Reference as well as these vertices:
Select the sketch as shown:
The following parting surface is created.
58 Page
Core and Cavity Design Version 5 Release 16

9. Click OK to exit the dialog box and create the parting surfaces as extrude features. A join is also created if the Join parting
surface option is checked.

G Merging distance is the distance at which two sections are considered to be in the same place for join
purposes.
G Maximum deviation is used to define the curve smooth.
59 Page
Core and Cavity Design Version 5 Release 16

By Loft
1. Now let's have a look at this portion of the parting surface:
2. Press the loft button.
3. select the two vertices that define the guide:
60 Page
Core and Cavity Design Version 5 Release 16
Then the two sections of the loft:
4. The proposed loft may be twisted due to the incoherent directions of the sections. In that case pick one red arrow to invert
the direction of one section.
61 Page
Core and Cavity Design Version 5 Release 16
5. Click OK to validate the loft and exit the action. The loft is created as a PrtSrf_Multi-sections Surface.x if the Join
parting surface option is not checked. A join is also created if the Join parting surface option is checked.

62 Page
Core and Cavity Design Version 5 Release 16
Aggregating Surfaces
This task shows you how to aggregate surfaces of an Geometrical set to improve performances.
1. Still in the same CATProduct, click the Aggregate icon .
2. The dialog box is displayed.
Select the Geometrical set where you want to aggregate surfaces in the list proposed.
The list of the surfaces contained in this Geometrical set and that are not in the NoShow is
displayed.
63 Page
Core and Cavity Design Version 5 Release 16
If you want to create a join datum, check the option.
Press OK. One surface or one join is created for each connex domain and the initial surfaces are deleted.
Before After
if Create a join datum is not checked

if Create a join datum is checked
or
64 Page
Core and Cavity Design Version 5 Release 16
Smooth Edges
This command provides a shortcut to customize the view type of smooth edges.
It is similar to Customizing the View Mode in Using Rendering Styles in the Infrastructure User's Guide.
65 Page
Core and Cavity Design Version 5 Release 16
Surface Boundaries
This task shows you how to display or hide the boundaries of surfaces.
1. Open file GettingStarted.CATPart in the samples directory.
2. Select the Analyze/Surface Boundaries menu . The dialog box is displayed.
3. This action is a toggle:
G check the Display Surfaces Boundaries option to display the boundaries of all surfaces,
G or uncheck it to hide the boundaries of all surfaces.
4. Click OK to valid your choice, or cancel to exit the action.
G This action is a quick way to activate or de-activate the display of surfaces boundaries. In this
regard, it is equivalent to the Tools > Options > Display > Visualization/Surfaces'Boundaries
option.
G In the Tools > Options > Display > Visualization tab, you can change the boundaries color and
line type.
G Both actions may require that you force the refresh of the graphic screen.
66 Page
Core and Cavity Design Version 5 Release 16
Face Orientation
This task shows you how to check the orientation of faces by colors and reorient them.
More Reference Information is available in the Face Orientation Parameters chapter.
Use this functionality should be used before computing a main pulling direction.
The model with faces to re-orient should be geometrically and topologically correct
1. Open file FirstMoldedPart.CATPart in the samples directory.

2. Click the Face Orientation icon , select all the faces and change the Reference Direction to 0,1,0 (as in the
picture below).

3. Click on Apply. The dialog box tells you that there are 113 faces in the model and that 73 of them need to be
reoriented.
67 Page
Core and Cavity Design Version 5 Release 16
4. Press the icon to see the list of surfaces that need to be inverted and to modify the selection (if required).
Press Close to return to the Surface Orientation dialog box.
68 Page
Core and Cavity Design Version 5 Release 16
5. Press OK to invert the surfaces that need to be and to close the dialog box.
69 Page
Core and Cavity Design Version 5 Release 16
Bounding Box
This task explains how to create a bounding box around a molded part.
You must have a molded part in the workbench.
1. Open FilterCover.CATPart in the samples/import directory.

2. Click on the Bounding Box icon .

3. Select the part. A dialog box is displayed that contains the minimum and maximum values that are required in X, Y and Z to create a box
that would surround the part. The default box is displayed in bold dark lines.
You can modify the X,Y,Z values if you choose.
70 Page
Core and Cavity Design Version 5 Release 16
4. You can also change the axis system used to define the rough stock by clicking on Select an axis and then choosing either:
G an axis in one of the other axis systems,
G a plane,
G or a planar surface.
5. Press OK to create the bounding box.
71 Page
Core and Cavity Design Version 5 Release 16
Sectioning
Through Sectioning, you can quickly estimate the thickness of the molded part, and thus the fabrication costs.
About Sectioning
Creating Section Planes: Click the icon.
Creating 3D Section Cuts: Create a section plane then click the icon.

Manipulating Section Planes Directly: Create a section plane, drag plane edges to re-dimension, drag
plane to move it along the normal vector, press and hold left and middle mouse buttons down to move
plane in U, V plane or local axis system or drag plane axis to rotate plane.

Positioning Planes with respect to a Geometrical Target: Create a section plane, click the icon then
point to the target of interest.

Positioning Planes Using the Edit Position and Dimensions Command: Create a section plane, click the
icon and enter parameters defining the plane position in the dialog box.

Using the Section Viewer: Create a section plane then click the icon.


72 Page
Core and Cavity Design Version 5 Release 16
About Sectioning
Using cutting planes, you can create sections, section slices, section boxes as well as 3D section cuts of your products
automatically.

G Section Plane
G Manipulating the Plane
G Section Results
G 3D Section Cut
G P1 and P2 Capabilities
H Creating Groups of products
G Customization Recommendations
Creating section slices and section boxes are DMU-P2 functionalities.

Section Plane
The section plane is created parallel to absolute coordinates Y, Z. The center of the plane is located at the center of the
bounding sphere around the products in the selection you defined.

G Line segments represent the intersection of the plane with all surfaces and volumes in the selection. By default, line segments
are the same color as the products sectioned.
73 Page
Core and Cavity Design Version 5 Release 16
G Points represent the intersection of the plane with any wireframe elements in the selection, and are visible in both the document
window and the Section viewer.
Notes:
G Any surfaces or wireframe elements in the same plane as the section plane are not visible.
G If no selection is made before entering the command, the plane sections all products.
A plane has limits and its own local axis system. The letters U, V and W represent the axes. The W-axis is the normal vector of the
plane.
You can customize settings to locate the center and orient the normal vector of the plane as well as de-activate the default setting
74 Page
Core and Cavity Design Version 5 Release 16
taking wireframe elements into account.
This is done using the Tools > Options..., Digital Mockup > DMU Space Analysis command (DMU Sectioning tab).
Manipulating the Plane
Sectioning is dynamic (moving the plane gives immediate results). You can manipulate the cutting plane in a variety of ways:
G Directly
G Position it with respect to a geometrical target, by selecting points and/or lines
G Change its current position, move and rotate it using the Edit Position and Dimensions command.
Section Results
Results differ depending on the sag value used.
Using default value (0.2mm): Using a higher value:
Sag: corresponds to the fixed sag value for calculating tessellation on objects (3D fixed accuracy) set in the Performance tab of
Tools > Options > General > Display.
By default, this value is set to 0.2 mm.
In Visualization mode, you can dynamically change the sag value for selected objects using the Tools -> Modify SAG command.
3D Section Cut
3D section cuts cut away the material from the cutting plane to expose the cavity within the product, beyond the slice or
outside the box.
P1 and P2 Capabilities
In DMU-P1, you cannot select products to be sectioned: the plane sections all products.
Creating Groups of Products
In DMU-P2, prior to creating your section plane, you can create a group containing the product(s) of interest using the Group
icon in the DMU Space Analysis toolbar or Insert > Group... in the menu bar.
Groups created are identified in the specification tree and can be selected from there for sectioning. Only one group per selection
75 Page
Core and Cavity Design Version 5 Release 16
can be defined
Customization Recommendations
For gain performances purposes, when dealing with CATProducts containing a large amount of sections, it is strongly
recommended to apply the following procedure before opening your CATProduct documents:
1. Select Tools > Options > Digital Mockup > DMU Navigator tab.
2. In Update settings category clear Update on product structure modifications and scenes activation o option.
3. Click Ok when done.
Note that clearing the Update on product structure modifications and scenes activation option makes the
three options available in Behavior tab of Sectioning dialog box ineffective (the sections will not be updated) as long
as you product is opened in session.
For more information refer to:
H Managing the Update of Section Results
H Customizing section.
76 Page
Core and Cavity Design Version 5 Release 16
Creating Section Planes
This task shows how to create section planes and orient the normal vector of the plane.
G About Section Planes
G Creating Section Planes (Step-by-step scenario)
G Result Windows
G Sectioning Definition Dialog Box
G P2 functionalities
Insert the following cgr files: ATOMIZER.cgr, BODY1.cgr, BODY2.cgr, LOCK.cgr, NOZZLE1.cgr,
NOZZLE2.cgr, REGULATION_COMMAND.cgr, REGULATOR.cgr, TRIGGER.cgr and VALVE.cgr.
They are to be found in the online documentation filetree in the common functionalities sample folder
cfysm/samples.
About Section Planes
The plane is created parallel to absolute coordinates Y, Z. The center of the plane is located at the
center of the bounding sphere around the products in the selection you defined.
G Line segments represent the intersection of the plane with all surfaces and volumes in the selection. By
default, line segments are the same color as the products sectioned.
G Points represent the intersection of the plane with any wireframe elements in the selection.
A section plane has limits and its own local axis system. U, V and W represent the axes. The W-axis is the
normal vector of the plane. The contour of the plane is red.
You can dynamically re-dimension and reposition the section plane. For more information, see Manipulating
Section Planes Directly.
Using the Tools > Options... command (DMU Sectioning tab under Digital Mockup > DMU Space
Analysis, you can change the following default settings:

G Location of the center of the plane
77 Page
Core and Cavity Design Version 5 Release 16
G Orientation of the normal vector of the plane
G Sectioning of wireframe elements.

Creating Section Planes
Before you begin

When dealing with CATProducts containing a large amount of sections, for gain performances purposes,
read carefully the Customization recommendations (follow the described procedure).
1. Select Insert -> Sectioning from the menu bar, or click the Sectioning icon in the DMU
Space Analysis toolbar to generate a section plane.
The section plane is automatically created. If no selection is made before entering the command, the
plane sections all products. If products are selected, the plane sections selected products.
78 Page
Core and Cavity Design Version 5 Release 16
P1 Functionality
In DMU-P1, you cannot select products to be sectioned: the plane sections all products.
2. Click the Selection box to activate it.
3. Click products of interest to make your selection, for example the TRIGGER and BODY1.Products
selected are highlighted in the specification tree and geometry area.
Note: Simply continue clicking to select as many products as you want. Products will be
placed in the active selection. To de-select products, reselect them in the specification tree or
in the geometry area.
The plane now sections only selected products
You can change the current position of the section plane with respect to the absolute axis system of
79 Page
Core and Cavity Design Version 5 Release 16
the document:
4. Click the Positioning tab in the Sectioning Definition dialog box.
5. Select X, Y or Z radio buttons to position the normal vector (W-axis) of the plane along the selected
absolute system axis. Select Z for example. The plane is positioned perpendicular to the Z-axis.
6. Double-click the normal vector of the plane (W-axis) or click the Invert Normal icon to invert it.
80 Page
Core and Cavity Design Version 5 Release 16
7. Click OK when done. The section plane definition and results are kept as a specification tree feature.
8. Click Close
By default, the plane is hidden when exiting the command. Use the Tools > Options, Digital
Mockup > DMU Space Analysis command (DMU Sectioning tab) to change this setting.
H To show the plane, select Hide/Show the plane representation in the contextual menu.
Note: In this case, you cannot edit the plane.
H To edit the plane again, double-click the specification tree feature.
81 Page
Core and Cavity Design Version 5 Release 16

Results Window
A Section viewer is automatically tiled vertically alongside the document window. It displays a front
view of the generated section and is by default, locked in a 2D view.
Notice that the section view is a filled view. This is the default option. The fill capability generates surfaces
for display and measurement purposes (area, center of gravity, etc.).

Sectioning Definition Dialog Box

82 Page
Core and Cavity Design Version 5 Release 16
The Sectioning Definition dialog box appears.
This dialog box contains a wide variety of tools letting you position, move and rotate the section plane as
well as create slices, boxes and section cuts. For more information, see Positioning Planes with respect to a
Geometrical Target, Positioning Planes Using the Edit Position Command, Creating Section Slices, Creating
Section Boxes and Creating 3D Section Cuts.


P2 Functionalities
In DMU-P2, you can create as many independent section planes as you like.
Creating section slices and section boxes are DMU-P2 functionalities.
83 Page
Core and Cavity Design Version 5 Release 16
Creating 3D Section Cuts
3D section cuts cut away the material from the plane, beyond the slice or outside the box to expose the cavity within the product.

This task explains how to create 3D section cuts:

G Creating 3D Section Cuts (Step-by-Step Scenario)
G 3D Section Cut Display
G P2 Functionality
G 3D Section Cut in DMU Review
Insert the following cgr files: ATOMIZER.cgr, BODY1.cgr, BODY2.cgr, LOCK.cgr, NOZZLE1.cgr, NOZZLE2.cgr,
REGULATION_COMMAND.cgr, REGULATOR.cgr, TRIGGER.cgr and VALVE.cgr.
They are to be found in the online documentation filetree in the common functionalities sample folder cfysm/samples.

Creating 3D Section Cuts
1. Select Insert > Sectioning from the menu bar, or click Sectioning in the DMU Space Analysis toolbar and create a
section plane. The Sectioning Definition dialog box appears.
84 Page
Core and Cavity Design Version 5 Release 16
2. In the Definition tab, click Volume Cut to obtain a section cut:
The material in the negative direction along the normal vector of the plane (W-axis) is cut away exposing the cavity within the
product.
Note: In some cases, the normal vector of the plane is inverted to give you the best view of the cut.
3. Double-click the normal vector of the plane to invert it, or click Invert Normal in the Positioning tab of the
Sectioning Definition dialog box.

4. Re-click the icon to restore the material cut away.
5. Click OK when done.
3D Section Cut Display
The 3D section cut display is different when the sectioning tool is a plane. To obtain the same display as for slices and boxes
(see illustrations below) and make measures on the generated wireframe cut:
G Select the Allow measures on a section created with a simple plane option in the DMU Sectioning tab (Tools > Options,
Digitial Mockup > DMU Space Analysis)
85 Page
Core and Cavity Design Version 5 Release 16
G Then, create your section cut based on a plane.

When the Sectioning Tool is a Slice: When the Sectioning Tool is a Box:
P2 Functionality
In DMU-P2, you can turn up to six independent section planes into clipping planes using the Volume Cut command to focus on
the part of the product that interests you most.
86 Page
Core and Cavity Design Version 5 Release 16
3D Section Cuts in DMU Review
Section cuts created during DMU Reviews are not persistent and are only valid for the duration of the review. If you exit the
DMU Review, the section cut is lost.
For more information about DMU Review, refer to DMU Navigator User's Guide

87 Page
Core and Cavity Design Version 5 Release 16
Manipulating Planes Directly



You can re-dimension, move and rotate section planes, or the master plane in the case of section slices and boxes, directly. As you
move the cursor over the plane, the plane edge or the local axis system, its appearance changes and arrows appear to help you.
G Re-dimensioning:
G Moving along the normal vector
of the plane:
G Rotating:
G Moving in the x,y plane of the
local axis system:
Sectioning results are updated in the Section viewer as you manipulate the plane.
To change this setting and have results updated when you release the mouse button only, de-activate the appropriate setting in the
DMU Sectioning tab (Tools ->Options..., Digital Mockup ->DMU Space Analysis).
This task illustrates how to manipulate section planes directly.
Insert the following cgr files: ATOMIZER.cgr, BODY1.cgr, BODY2.cgr, LOCK.cgr, NOZZLE1.cgr, NOZZLE2.cgr,
REGULATION_COMMAND.cgr, REGULATOR.cgr, TRIGGER.cgr and VALVE.cgr.
They are to be found in the online documentation filetree in the common functionalities sample folder cfysm/samples.
88 Page
Core and Cavity Design Version 5 Release 16
1. Select Insert > Sectioning from the menu bar, or click Sectioning in the DMU Space Analysis toolbar and create a
section plane.
A Section viewer showing the generated section is automatically tiled vertically alongside the document window. The
generated section is automatically updated to reflect any changes made to the section plane.You can re-dimension the section
plane:
2. Click and drag plane edges to re-dimension plane:
Note: A dynamic plane dimension is indicated as you drag the plane edge.
You can view and edit plane dimensions in the Edit Position and Dimensions command. The plane height corresponds to its
dimension along the local U-axis and the width to its dimension along the local V-axis.You can move the section plane along
the normal vector of the plane:
3. Move the cursor over the plane, click and drag to move the plane to the desired location.You can move the section plane in
the U,V plane of the local axis system:
4. Press and hold down the left mouse button, then the middle mouse button and drag (still holding both buttons down) to move
the plane to the desired location. You can rotate the section plane around its axes:
5. Move the cursor over the desired plane axis system axis, click and drag to rotate the plane around the selected axis.
89 Page
Core and Cavity Design Version 5 Release 16
6. (Optional) Click Reset Position in the Positioning tab of the Sectioning Definition dialog box to restore the center of
the plane to its original position.
7. Click OK in the Sectioning Definition dialog box when done.
Note: You cannot re-dimension, move or rotate the plane via the contextual menu command Hide/Show the plane
representation.

90 Page
Core and Cavity Design Version 5 Release 16
Positioning Planes On a Geometric Target
You can position section planes, section slices and section boxes with respect to a geometrical target (a face, edge, reference plane or cylinder axis). In the case of section
slices and boxes, it is the master plane that controls how the slice or box will be positioned.

This task illustrates how to position a section plane with respect to a geometrical target.
Insert the following cgr files: ATOMIZER.cgr, BODY1.cgr, BODY2.cgr, LOCK.cgr, NOZZLE1.cgr, NOZZLE2.cgr, REGULATION_COMMAND.cgr, REGULATOR.cgr, TRIGGER.cgr
and VALVE.cgr.
They are to be found in the online documentation file tree in the common functionalities sample folder cfysm/samples.

1. Select Insert > Sectioning from the menu bar, or click Sectioning in the DMU Space Analysis toolbar and create a section plane. The Sectioning
Definition dialog box appears.
A Section viewer showing the generated section is automatically tiled vertically alongside the document window.
The generated section is automatically updated to reflect any changes made to the section plane.
2. Click the Positioning tab in the Sectioning Definition dialog box.
3. Click Geometrical Target to position the plane with respect to a geometrical target.
4. Point to the target of interest:
91 Page
Core and Cavity Design Version 5 Release 16
A rectangle and vector representing the plane and the normal vector of the plane appear in the geometry area to assist you position the section plane. It moves as
you move the cursor.
5. When satisfied, click to position the section plane on the target.
Notes:
H To position planes orthogonal to edges, simply click the desired edge.
H A smart mode recognizes cylinders and snaps the plane directly to the cylinder axis. This lets you, for example, make a section cut normal to a hole
centerline. To de-activate this mode, use the Ctrl key.
92 Page
Core and Cavity Design Version 5 Release 16
H Selecting the Automatically reframe option in the DMU Sectioning tab (Tools -> Options -> Digital Mockup -> DMU Space Analysis), reframes the
Section viewer and locates the point at the center of the target at the center of the Section viewer.
Zooming in lets youpinpointthe selected point.
This is particularly useful when using snap capabilities in a complex DMU session containing a large number of objects.
6. (Optional) Click Reset Position to restore the center of the plane to its original position.
7. Click OK in the Sectioning Definition dialog box when done.
P2 Functionality
In DMU-P2, you can move the plane along a curve, edge or surface:
1. Point to the target of interest
2. Press and hold down the Ctrl key
3. Still holding down the Ctrl key, move the cursor along the target. The plane is positioned tangent to the small target plane
4. As you move the cursor, the plane moves along the curve or edge.
93 Page
Core and Cavity Design Version 5 Release 16
Positioning Planes Using the Edit Position and Dimensions
Command
In addition to manipulating the plane directly in the geometry area, you can position the section plane more precisely using the Edit
Position and Dimensions command. You can move the plane to a new location as well as rotate the plane. You can also re-dimension
the section plane.
In the case of section slices and boxes, it is the master plane that controls how the slice or box will be positioned.

This task illustrates how to position and re-dimension the section plane using the Edit Position and Dimensions command.
Insert the following cgr files: ATOMIZER.cgr, BODY1.cgr, BODY2.cgr, LOCK.cgr, NOZZLE1.cgr, NOZZLE2.cgr,
REGULATION_COMMAND.cgr, REGULATOR.cgr, TRIGGER.cgr and VALVE.cgr.
They are to be found in the online documentation filetree in the common functionalities sample folder cfysm/samples.
1. Select Insert > Sectioning from the menu bar, or click Sectioning in the DMU Space Analysis toolbar and create a
section plane.
A Section viewer showing the generated section is automatically tiled vertically alongside the document window. The
generated section is automatically updated to reflect any changes made to the section plane.
The Sectioning Definition dialog box is also displayed.
2. Click the Positioning tab in the Sectioning Definition dialog box.
3. Click the Edit Position and Dimensions to enter parameters defining the position of the plane.
The Edit Position and Dimensions dialog box appears.
94 Page
Core and Cavity Design Version 5 Release 16

4. Enter values in Origin X, Y or Z boxes to position the center of the plane with respect to the absolute system coordinates
entered.
By default, the center of the plane coincides with the center of the bounding sphere around the products in the current
selection.
Notes:
H Using the Tools > Options... command (DMU Sectioning tab under Digital Mockup > DMU Space Analysis), you
can customize settings for both the normal vector and the origin of the plane
H Units are current units set using Tools > Options.
5. Enter the translation step directly in the Translation spin box or use spin box arrows to scroll to a new value, then click -Tu,
+Tu, -Tv, +Tv, -Tw, +Tw, to move the plane along the selected axis by the defined step.
Note: Units are current units set using Tools > Options (Units tab under General > Parameters and Measure).
6. Change the translation step to 25mm and click +Tw for example. The plane is translated 25 mm in the positive direction along
the local W-axis.
95 Page
Core and Cavity Design Version 5 Release 16
You can rotate the section plane. Rotations are made with respect to the local plane axis system
You can move the section plane to a new location. Translations are made with respect to the local plane axis system.
7. Enter the rotation step directly in the Rotation spin box or use spin box arrows to scroll to a new value, then click -Ru, +Ru, -
Rv, +Rv, -Rw, +Rw, to rotate the plane around the selected axis by the defined step.
With a rotation step of 45 degrees, click +Rv for example to rotate the plane by the specified amount in the positive direction
around the local V-axis.
You can edit plane dimensions. The plane height corresponds to its dimension along the local U-axis and the width to its
dimension along the local V-axis. You can also edit slice or box thickness.
8. Enter new width, height and/or thickness values in the Dimensions box to re-dimension the plane. The plane is re-sized
accordingly.
9. Click Close in the Edit Position and Dimensions dialog box when satisfied.
96 Page
Core and Cavity Design Version 5 Release 16
10. Click OK in the Sectioning Definition dialog box when done.


G Click Undo and Redo in the Edit Position and Dimensions dialog box to cancel the last action or recover the last action undone
respectively.
G Click Reset Position in the Positioning tab of the Sectioning Definition dialog box to restore the section plane to its
original position.
G You can also view and edit plane dimensions in the Properties dialog box (Edit > Properties or via the contextual menu).
This command is not available when using the sectioning command.

97 Page
Core and Cavity Design Version 5 Release 16
More About the Section Viewer
This task illustrates how to make the most of section viewer capabilities:

G Accessing the Section viewer capabilities
G Step-by-Step Scenario
H Section Viewer
H Orienting the section
H Working with the 2D grid
H Working with a 3D view
G Detecting collisions (P2)
Accessing the Section viewer capabilities
Most of the commands described in this task are to be found in the Result tab of the Sectioning Definition dialog box or in
the Section viewer contextual menu.

Step-by-Step Scenario
98 Page
Core and Cavity Design Version 5 Release 16
Insert the following cgr files: ATOMIZER.cgr, BODY1.cgr, BODY2.cgr, LOCK.cgr, NOZZLE1.cgr, NOZZLE2.cgr,
REGULATION_COMMAND.cgr, REGULATOR.cgr, TRIGGER.cgr and VALVE.cgr.
They are to be found in the online documentation filetree in the common functionalities sample folder cfysm/samples.
Before you begin
When dealing with CATProducts containing a large amount of sections, for gain performances purposes, read carefully the
Customization recommendations (follow the described procedure).
1. Select Insert > Sectioning from the menu bar, or click Sectioning in the DMU Space Analysis toolbar and create
the desired section plane, slice or box and corresponding section.
Section Viewer
The Section viewer is automatically tiled vertically alongside the document window. It displays a front view of the section, and
is by default, locked in a 2D view. Points representing the intersection of the section plane with any wire frame elements are also
visible in the Section viewer.
Notice that the section view is a filled view. This is the default option. The fill capability generates surfaces for display and
measurement purposes (area, center of gravity, etc.). To obtain a correct filled view, the section plane must completely envelop the
product.
Note: The filled view is not available when the plane sections surfaces.
To obtain an unfilled view, de-activate the Section Fill icon in the Result tab of the Sectioning Definition dialog box.

99 Page
Core and Cavity Design Version 5 Release 16

G In the Section viewer, the appearance of the cursor changes to attract your attention to the existence of the contextual menu.
G You can change the default settings for this window using Tools ->Options... command (DMU Sectioning tab under Digital
Mockup ->DMU Space Analysis).
Orienting the Section
2. Orient the generated section.Flip and Rotate commands are to be found in the contextual menu. Right-click in the Section
viewer and:
H Select Flip Vertical or Flip Horizontal to flip the section vertically or horizontally 180 degrees.
H Select Rotate Right or Rotate Left to rotate the section right or left 90 degrees.

Orienting the section using Flip and Rotate commands is not persistent. If you exit the section viewer, any flip and
rotate settings are lost.
Working with the 2D Grid
3. Click the Result tab in the Sectioning Definition dialog box, then select the Grid icon under Options to display a 2D
grid.
By default, grid dimensions are those of the generated section. Moving the section plane re-sizes the grid to results. To
size the grid to the section plane, clear the Automatic grid re-sizing check box in the DMU Sectioning tab (Tools >
Options..., Digital Mockup > DMU Space Analysis).
100 Page
Core and Cavity Design Version 5 Release 16
You can edit the grid step, style and mode using the Edit Grid command.
4. Select the Edit Grid icon to adjust grid parameters: The Edit Grid dialog box appears: In the above example, the grid
mode is absolute and the style is set to lines.
101 Page
Core and Cavity Design Version 5 Release 16
In the absolute mode, grid coordinates are set with respect to the absolute axis system of the document.
The grid step is set to the default value of 100. The arrows let you scroll through a discrete set of logarithmically calculated
values. You can also enter a grid step manually.
Units are current units set using Tools > Options (Units tab under General > Parameters and Measure).
5. Scroll through grid width and height and set the grid step to 10 x 10.
6. Click the Relative mode option button: In the relative mode, the center of the grid is placed on the center of section plane.
7. Click the Crosses style.
Grid parameters are persistent: any changes to default parameters are kept and applied next time you open the viewer or re-
edit the section.
8. Click Automatic filtering check box to adjust the level of detail of grid display when you zoom in and out.
9. Right-click the grid then select Coordinates to display the coordinates at selected intersections of grid lines. The Clean All
command removes displayed grid coordinates.
102 Page
Core and Cavity Design Version 5 Release 16
Notes:
H You can customize both grid and Section viewer settings using the Tools > Options... command (DMU Sectioning
tab under Digital Mockup > DMU Space Analysis).
H Alternatively, select Analyze > Graphic Messages > Coordinate to display the coordinates of points, and/or
Name to identify products as your cursor moves over them.
H Clicking turns the temporary markers into 3D annotations.
10. Click OK in the Edit Grid dialog box when done.
Working with a 3D View
By default, the Section viewer is locked in a 2D view. De-activating the 2D view lets you:
G Work in a 3D view and gives you access to 3D viewing tools
G Set the same viewpoint in the Section viewer as in the document window.
Returning to a 2D view snaps the viewpoint to the nearest orthogonal view defined in the Section viewer.
11. Right-click in the Section viewer and select the 2D Lock command from the contextual menu. The Import Viewpoint
command becomes available.

12. Manipulate the section plane.
103 Page
Core and Cavity Design Version 5 Release 16
13. Right-click in the Section viewer and select the Import Viewpoint command from the contextual menu. The viewpoint in the
Section viewer is set to that of the document window.
14. Continue manipulating the section plane.
15. Return to a locked 2D view.
104 Page
Core and Cavity Design Version 5 Release 16
The viewpoint in the Section viewer snaps to the nearest orthogonal viewpoint in this viewer and not to the viewpoint defined
by the local axis system of the plane in the document window.
You can also save sectioning results in a variety of different formats using the Export As command in the Result tab of the
Sectioning Definition dialog box or the Capture command (Tools > Image > Capture).
16. Click OK in the Sectioning Definition dialog box when done. If you exit the Sectioning command with the Section viewer still
active, this window is not closed and filled sections remain visible.

P2 Functionality - Detecting Collisions
In DMU-P2, You can detect collisions between 2D sections. To do so, click Clash Detection in the Result tab of the
Sectioning Definition dialog box.
Clashes detected are highlighted in the Section viewer.
Collision detection is dynamic: move the section plane and watch the Section viewer display being updated.
105 Page
Core and Cavity Design Version 5 Release 16

Note: Clash detection is not authorized when in the Section Freeze mode.

106 Page
Core and Cavity Design Version 5 Release 16
Performing a Surface Curvature Analysis
This task shows how to analyze the mapping curvature of a surface.
G This command is not available with the Generative Shape Design 1.
G This command is available with the Part Design in configuration mode P2.
G Surfacic curvature analyses can be performed on a set of surfaces.
G If an element belongs to an analysis, it cannot be selected simultaneously for another analysis, you
need to remove the current analysis by deselecting the element to be able to use it again.
G In some cases, even though the rendering style is properly set, it may happen that the analysis results
are not visible. Check that the geometry is up-to-date, or perform an update on the involved
geometric elements.
G The analysis results depend of the current object. May you want to change the scope of analysis, use
the Define in Work object contextual command.
Open the FreeStyle_02.CATPart document:
G The discretization option should be set to a maximum: in Tools -> Options -> Display ->
Performances, set the 3D Accuracy -> Fixed option to 0.01
G Uncheck the Highlight faces and edges option in Tools -> Options -> General -> Display ->
Navigation to disable the highlight of the geometry selection.
G Check the Material option in the View -> Render Style -> Customize View command to be able to
see the analysis results on the selected element. You can now perform an analysis On the Fly even if
the Material option is not checked, see On the Fly option. No warning message is issued as long as no
element is selected.
1. Select Surface.1

2. Click the Surfacic Curvature Analysis icon:
The Surfacic curvature dialog box is displayed, and the analysis is visible on the selected
element.
107 Page
Core and Cavity Design Version 5 Release 16

The Surfacic curvature dialog box displays the following information:
G Type analysis option allows you to make the following analyses:
H Gaussian
H Minimum
H Maximum
H Limited
H Inflection Area
G Display Options are:
H Color Scale option allows you to display the Surfacic Curvature Analysis.n dialog box
associated with the current analysis.
H On the Fly option allows you to make a local analysis:
I The On the fly analysis can be performed on the elements, selected or not, of the
current part only. It is not available with the Inflection Area analysis type.
I The curvature and radius values are displayed at the cursor location (for Gaussian
analysis radius value is not displayed), as well as the minimum and maximum curvature
values and the minimum and maximum curvature directions. As you move the pointer
over the surface, the display is dynamically updated.
I The displayed values may vary from the information displayed as the Use Max/Use
Min values, as it is the precise value at a given point (where the pointer is) and does
not depend on the set discretization.
I You cannot snap on point when performing an On the Fly analysis.
I Click a location and right-click the On the Fly curvature/radius label to display the
contextual commands.
These commands are not available in P1 mode:
108 Page
Core and Cavity Design Version 5 Release 16
I Keep Point: create the point at the clicked location.
I Keep Min Point: create the point corresponding to the minimum value.
I Keep Max Point: create the point corresponding to the maximum value.
I 3D MinMax option allows you to locate the minimum and maximum values for the
selected analysis type, except for Inflection Area analysis type.
G Analysis Options are:
H Positive only option allows you to get analysis values as positive values, available with
Gaussian, Minimum and Maximum analysis types only.
H Radius Mode option allows you to get analysis values as radius values, available with
Minimum and Maximum analysis types only.
The Surfacic Curvature Analysis.1 dialog box showing the color scale and identifying the
maximum and minimum values for the analysis is displayed too.

109 Page
Core and Cavity Design Version 5 Release 16
G You can right-click on a color rectangle in the color scale to display the contextual menu:
H Edit contextual command allows you to modify the values in the color range to highlight
specific areas of the selected surface. The Color dialog box is displayed allowing the user to
modify the color range.
110 Page
Core and Cavity Design Version 5 Release 16
H Unfreeze contextual command allows you to perform a linear interpolation between non
defined colors.
H No Color contextual command can be used to simplify the analysis, because it limits the
number of displayed colors in the color scale. In this case, the selected color is hidden, and
the section of the analysis on which that color was applied takes on the neighboring color.
111 Page
Core and Cavity Design Version 5 Release 16
G You can also right-click on the value to display the contextual menu:
H Edit contextual command allows you to modify the edition values.
112 Page
Core and Cavity Design Version 5 Release 16
The Value Edition dialog box is displayed: enter a new value (negative values are allowed)
to redefine the color scale, or use the slider to position the distance value within the
allowed range, and click OK.
The value is then frozen, and displayed in a green rectangle.
H Unfreeze contextual command allows you to perform a linear interpolation between non
defined values. This command is available for all values except for maximum and minimum
values.
The unfreezed values are no longer highlighted in green.
H Use Max / Use Min contextual commands allow you to evenly distribute the color/value
interpolation between the current limit values, on the top/bottom values respectively,
rather than keeping it within default values that may not correspond to the scale of the
geometry being analyzed. Therefore, these limit values are set at a given time, and when
the geometry is modified after setting them, these limit values are not dynamically
updated.
I These commands are available for maximum and minimum values only.
I The Use Max command is available if the maximum value is higher or equal to the
medium value, otherwise you need to unfreeze the medium value first.
I The Use Min command is available if the minimum value is lower or equal to the
medium value, otherwise you need to unfreeze the medium value first.
G Use Min Max button in the Surfacic Curvature Analysis.1 dialog box makes in one action
the both Use Max / Use Min contextual commands operation.
G The Surfacic Curvature Analysis.1 in created in the specification tree under the Free Form
Analysis.1
113 Page
Core and Cavity Design Version 5 Release 16
Analysis Types and Display Options
3. Select the Gaussian analysis type and the On the Fly option.

4. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.
Maximum and minimum values are set according to the computed values displayed below the color
scale.

114 Page
Core and Cavity Design Version 5 Release 16
5. Move the cursor on the surface.
You can also right-click On the Fly curvature/radius label to display the contextual commands, see
On the Fly option.
115 Page
Core and Cavity Design Version 5 Release 16
Case of a Ruled Surface

6. Select Surface.2
7. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.
Values are equal to 0.

8. Move the cursor on the surface.
116 Page
Core and Cavity Design Version 5 Release 16

9. Select Surface.1
10. Select the Minimum analysis type.
11. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.

117 Page
Core and Cavity Design Version 5 Release 16
12. Move the cursor on the surface.
Minimum curvature and radius values are displayed.
118 Page
Core and Cavity Design Version 5 Release 16
The color scale in the Surfacic Curvature Analysis.1 dialog box corresponds to the previous type
analysis (Gaussian).
The color scale doesn't change when you select another analysis type or element. This behavior
allows you keep a reference when you compare curvature values.
13. Select the Maximum analysis type.
14. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.

15. Move the cursor on the surface.
Maximum curvature and radius values are displayed.
119 Page
Core and Cavity Design Version 5 Release 16
16. Select the Limited analysis type.
In the Surfacic curvature dialog box:
G You are able to modify the radius value. The value is automatically updated in the color scale.
G Positive only and Radius mode options have been disabled.

120 Page
Core and Cavity Design Version 5 Release 16
The Surfacic Curvature Analysis.1 dialog box has been modified: the color scale has been
reduced: four colors and three values.

17. Edit the top color and the maximal and minimal values in the Surfacic Curvature Analysis.1
dialog box as follow, see Edit color and Edit edition values.

Minimum curvature and radius values are displayed.
121 Page
Core and Cavity Design Version 5 Release 16
18. Select the Inflection Area analysis type.
In the Surfacic curvature dialog box only the Color Scale option is available.

The Surfacic Curvature Analysis.1 dialog box has been modified.
122 Page
Core and Cavity Design Version 5 Release 16

This analysis enables to identify the curvature orientation:
G In green: the areas where the minimum and maximum curvatures present the same
orientation.
G In blue: the areas where the minimum and maximum curvatures present opposite orientation.
See also Creating Inflection Lines. Note that these inflection lines are always created within the
green area, i.e. when the curvature orientation is changing.
19. Select the Minimum analysis type and the 3D MinMax option.
20. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.
123 Page
Core and Cavity Design Version 5 Release 16

Maximum and minimum values are displayed and located on the selected element according to the
computed values displayed below the color scale.

Analysis Options
124 Page
Core and Cavity Design Version 5 Release 16
21. Select the Positive only option and keep unselected the Radius Mode option.
22. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.
Minimum value is set to 0 below the color scale

Only positive values are displayed and located on the selected element. Minimum value is set to 0
below the color scale
125 Page
Core and Cavity Design Version 5 Release 16
23. Select the Radius Mode option and unselect the Positive only option.
24. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.
25. Edit the minimal value in the Surfacic Curvature Analysis.1 dialog box as follow, see Edit edition
values.

126 Page
Core and Cavity Design Version 5 Release 16
Maximum and minimum radius values are displayed and located on the selected element according
to the computed values displayed below the color scale.
26. Select the Gaussian analysis type.
127 Page
Core and Cavity Design Version 5 Release 16
27. Click the Use Min Max button in the Surfacic Curvature Analysis.1 dialog box.

28. Click OK in the Surfacic curvature dialog box.

29. Click the Control Points icon:
You can display the control points still viewing the surfacic curvature analysis. This allows you to
check any modification which affect the surface.
128 Page
Core and Cavity Design Version 5 Release 16

30. Click Cancel in the Control Points dialog box.
129 Page
Core and Cavity Design Version 5 Release 16
Workbench Description
This section describes the menu commands and icon toolbars that are specific to the Core &Cavity Design
workbench.
Menu Bar Description
Tool Bar Description
Specifications Tree
130 Page
Core and Cavity Design Version 5 Release 16
Menu Bar Description
This is the menu bar for the Core &Cavity Design workbench.
Start SmarTeam File Edit View Insert Tools Analyze
Tasks corresponding to general menu commands are described in the CATIA Version 5 Infrastructure User's Guide.

Start

Starts the Core & Cavity Design workbench

Insert

Annotations Adds text and hyperlinks to the part
Axis system ... Creates an axis system.
Models ... Creates a model-related operation
Pulling Direction Creates a pulling direction operation
Parting Line Inserts a parting line element
Parting Surface Inserts a parting surface element
Wireframe Inserts a wireframe element
Operations Inserts an auxiliary operation
Advanced Replication Tools Provides PowerCopy operations

Annotations
For See
Text with Leader Creating Textual Annotations
131 Page
Core and Cavity Design Version 5 Release 16

Flag Note with Leader Creating Flag Notes
Models
Imports a model into the workbench
Compares two molded parts
Creates a bounding box around the model

Pulling Direction


Defines Pulling Direction Defining the Main Pulling Direction
Defines Slider Lifter Defining the Pulling Direction for Slider Areas
Transfer Transferring Elements
SplitMoldArea Splitting a Face
Aggregate MoldArea Aggregating Surfaces
Explode view Explodes the part in the view
Face orientation Checks the orientation of faces

Parting Line


Boundary ... Creating Boundary Curves
ReflectLine ... Creating Reflect Lines
Curve Smooth... Smoothing curves

Parting Surface



Parting surface... Creating a Parting Surface
Fill ... Creating Fill Surfaces
Extrude ... Creating Extruded Surfaces
Sweep ... Creating Swept Surfaces
Loft ... Creating Lofted surfaces
Extrapolate ... Extrapolating Surfaces or Extrapolating curves
Blend ... Creating Blended Surfaces

Wireframe


Point ... Creating Points
Line ... Creating Lines
Plane ... Creating Planes
Projection... Creating Projections
Intersection... Creating Intersections
Parallel Curve... Creating Parallel Curves
Connect Curve... Creating Connect Curves
3D Curve ... Creating Splines
132 Page
Core and Cavity Design Version 5 Release 16
Curve on Surface
Creating Free Form Curves on Surfaces in the
FreeStyle Shaper Optimizer & Profiler User's Guide

Operations


Join ... Joining Surfaces or Curves
Untrim ... Restoring a Surface
Split... Splitting Geometry
Trim ... Trimming Geometry
Extract ... Extracting Geometry
Shape Fillet ... Creating Shape Fillets
Edge Fillet Creating Edge Fillets
Variable Fillet ... Creating Variable Radius Fillet
Face-Face Fillet ... Creating Face-Face Fillet.
Tritangent Fillet... Creating Tritangent Fillets
Translate... Translating Geometry
Rotate... Rotating Geometry
Symmetry... Performing a Symmetry on Geometry

Advanced Replication Tools


PowerCopy Creation... Creating PowerCopy
Save in Catalog... Saving PowerCopies into a Catalog
Instantiate From Document... Instantiating PowerCopies

Analyze

Sectioning Sectioning
Surface Boundaries Surface Boundaries

Smooth Edges Smooth Edges
Surfacic Curvature Analysis Performing a Surfacic Curvature Analysis
133 Page
Core and Cavity Design Version 5 Release 16
Tool Bar Description
These are the specific icon toolbars that belong to the Core &Cavity Design workbench.
Import Part
Pulling Direction
Parting Line
Wireframe
Parting Surface
Operations
Advanced Replication Tools
Annotations
134 Page
Core and Cavity Design Version 5 Release 16
Import Model Tool Bar
Imports a molded part into the workbench.
Compares two models to find the differences between them.
Creates a bounding box around a part.
135 Page
Core and Cavity Design Version 5 Release 16
Pulling Direction Tool Bar
Defines the main pulling direction.
Defines a pulling direction for the slider or lifter areas.
Transfers elements from one side to another.
Splits a face into facets.
Aggregating Surfaces
Explodes the part in the view
Checks the orientation of faces
136 Page
Core and Cavity Design Version 5 Release 16
Parting Line Tool Bar

Creates a boundary from a surface.
Creates a reflect line.
Smoothes curves
137 Page
Core and Cavity Design Version 5 Release 16
Wireframe Tool Bar

Creates one or more points.
Creates a line
Creates a plane
Projects a point or a curve
Creates an intersection
Creates a parallel curve
Creates a connecting curve
Creates a curve
Creates curves on surface, see FreeStyle Shaper Optimizer & Profiler
138 Page
Core and Cavity Design Version 5 Release 16
Parting Surface Tool Bar
Creates a parting surface around the part
Creates a filled surface inside a closed boundary.
Creates an extruded surface.
Creates a swept surface.
Creates a lofted surface.
Creates a surface or curve by extrapolation.
Blends two surfaces.
139 Page
Core and Cavity Design Version 5 Release 16
Operations Tool Bar
See the Generative Shape Design & Optimizer user's guide for more information on how to use these functions.
Joins curves or surfaces.
Untrims an element.
Cuts and relimits an element using a cutting element.
Trims two elements.
Extracts a face or an edge from a surface.
Creates a shape fillet.
Creates a fillet on an edge.
Creates a variable fillet.
Creates a fillet between faces.
Creates a tritangent fillet.
Translates an element in a given direction.
Rotates an element around an axis.
Transforms an element by symmetry.
140 Page
Core and Cavity Design Version 5 Release 16
Advanced Replication Tool Bar
See the Generative Shape Design & Optimizer user's guide for more information on how to use these functions.
Creates PowerCopy elements
Stores PowerCopy elements into a catalog
Instantiates PowerCopies
141 Page
Core and Cavity Design Version 5 Release 16
Annotations Tool Bar
See the Generative Shape Design & Optimizer user's guide for more information on how to use these functions.
Creates text with a leader line attached to the part
Adds a hyperlink to the document
142 Page
Core and Cavity Design Version 5 Release 16
Specifications Tree
The icons in the specification tree are standard.


143 Page
Core and Cavity Design Version 5 Release 16
Reference Information
Reference information that is specific to the Core and Cavity Design can be found in this section
Import Model Parameters
Pulling Direction Parameters
Slider Lifter Direction Parameters
Transfer an Element Parameters
Compare Models Parameters
Split Mold Area Parameters
Face Orientation Parameters
Bounding Box
144 Page
Core and Cavity Design Version 5 Release 16
Import Model Parameters
More Operating Mode information is available in the Basic Task Import Model.

Model
Reference
Path and name of the CATPart you are going to use. Push the icon to browse your directories to the location of the CATPart.
Body
Element in the reference file that you wish to import. Use the combo list to select it.
G If the CATPart selected contains a PartBody, i.e. a solid, this PartBody is proposed by default.
G If there is no valid PartBody available, the first non-empty Geometrical set is proposed.
For a quick overview of the model, you can choose to work on a set of loose faces instead of closed solids.
If you wish to import a set of faces, first press the icon (for importing closed solids) so that the icon for importing a set of faces
is displayed, , then choose your file.
Surface
Surface that you wish to use for the computation and is only displayed when you have a choice of surfaces to use in the body. The
surface proposed by default is the last surface in the Geometrical set, because it should be the most complete surface, i.e. the most
susceptible to be closed.
145 Page
Core and Cavity Design Version 5 Release 16
G This is what you get when you import a PartBody:
G This is what you get when you import an Geometrical set:
External References is the link with the initial model.
G You may also get this message and this specification tree as you push the Close button::
146 Page
Core and Cavity Design Version 5 Release 16
This means that the surface you have selected could not be closed by a planar face. The CloseSurface required by Core
and Cavity could not be created. You must delete the invalid elements created in the specification tree (you can use the
Undo function) and restart the import with a valid model.
G To avoid this problem, you can open your model in another window to visualize the element you import.


Axis system
Defines the origin of the Molded Part, and also the initial axis system.
The Origin position (X,Y,Z) is defined via one of the following menu options :
G Bounding box center: the origin is the center of the virtual bounding box around the part.
G Center of gravity: the origin is the center of gravity of the model.
G Coordinates: you can enter an origin and the system will be parallel to the main axis system.
G Local axis system: the origin is that of the axis system that is defined in the model you are importing.
The Axis system is generated according to the option which has been selected :
G with Local axis system: with the axis system planes of the model imported,
G with the other options: with the standard main planes.
Only the Coordinates menu option enables you to edit the origin directly in the dialog box.
147 Page
Core and Cavity Design Version 5 Release 16

Shrinkage
Plastic shrinkage can be allowed for either by:
G Scaling : the default Scaling ratio proposed is 1. You can modify this value. The reference point for Scaling is the origin of
the Axis System defined just before. This point cannot be modified in this frame.
G or Affinity which is defined by giving 3 axis ratios. The default Affinity ratio proposed is 1 along the 3 axes. You can
modify the 3 ratios. The Axis system of the Affinity (Origin, Plane XY, Axis X) is the one defined just before. This axis system
cannot be modified in this frame.
You should avoid changing the affinity default value until just before removing the material.
148 Page
Core and Cavity Design Version 5 Release 16
Pulling Direction Parameters
More Operating Mode information is available in the Basic Task Defining the Main Pulling Direction and
Defining the Main Pulling Direction with No Draft.
Draft: Pulling Axis System
Direction
Pulling axis direction that can be defined:
G either by entering the X,Y,Z coordinates,
149 Page
Core and Cavity Design Version 5 Release 16
G or by using the compass. The compass is snapped automatically onto the current axis system. You can
change the location of the compass, or rotate it. The direction in the dialog box is updated accordingly,
the main direction being the Z axis of the compass.
The pulling axis direction can be locked once you have set the axis system so as to avoid unintentional
modifications that can be made when you are moving the compass.
You can use the Reverse button to reverse the pulling direction.
Locked
Lock the Pulling axis direction before using:
G the Local Transfer,
G the Fly analysis,
G the Explode option,
Fly analysis
Check this option to display the normal to the face when you move the mouse pointer over the surface.

Draft angle
Defines the minimum un-molding angle between the surface and the main pulling direction.
150 Page
Core and Cavity Design Version 5 Release 16
Mold Areas
Areas to extract
They are the Core side (displayed in red), the Cavity side (displayed in green), Other (displayed in blue)
and No Draft (displayed in pink). Other indicates surfaces that are neither core or cavity and that will be
dealt with later. No Draft is made of the surfaces that are vertical with respect to the draft angle.

Facets to ignore
If even only one facet a face is not clearly either core or cavity, the whole face will be considered to be
"other" and displayed in blue. You can use the Facet Display option to solve this problem.
One solution is to "ignore" a given percentage of those alien facets. To do so, check the Facets to ignore
option and use the slider to define this percentage.
Consider this example.
151 Page
Core and Cavity Design Version 5 Release 16
We have checked the Facet display option:
It is clear that a little amount of facets is considered as belonging to the Core and not to the Cavity. If
those facets were ignored, the blue portion would belong to the Cavity, which is what we want.
We have unchecked the Facet display, checked Facets to ignore and defined the percentage of facets
to ignore with the slider. This is what we get:
152 Page
Core and Cavity Design Version 5 Release 16


Undercut
Undercut zones are recognized via the facettisation of the part. Zones are defined by the angle formed by
the facet normal and the pulling direction. Under cut areas that make the un-molding of a zone impossible
are ignored. This leads to incorrect definition of areas. For example, the small green face below, seen as a
Cavity area, should be blue, i.e. belonging to Other areas.
Undercut off Undercut on
Check Undercut to take account of hidden faces for a given pulling direction.

Switch
The orientation of the facets normals may also lead to "inverted" core and cavity areas for a given pulling
direction, i.e. the expected Core area is recognized as a Cavity area, and vice-versa.
Push the switch button to invert those areas directly, without inverting the orientation of the normals nor
the pulling direction.
153 Page
Core and Cavity Design Version 5 Release 16
Local Transfer
Transfers one face of the part to one of the three areas to extract (Core, Cavity, Other).
Local transfer is available in exploded view.
1. Lock the Direction.
2. Check Local Transfer.
3. Select the area where you want to transfer the face in the list.
4. Select the kind of propagation you want to use from the list.
G No propagation: you pick the faces you want to transfer one by one.
G Point continuity: you pick one face and all the faces of the same initial color that have a point
continuity with this face will be selected and transferred.
G By area: useful when a few faces of a given color are found among the destination faces, but are not
connected to each other:
You select one red face and all the other red faces found among the green ones will
154 Page
Core and Cavity Design Version 5 Release 16
be transferred.
The faces selected are transferred to the destination area, this transfer is taken into
account immediately.
Should you wish to change the selection to transfer locally, press the Undo button
. This button is inactive when you are using Explode Visualization mode.


Visualization
By default, Faces display is active, i.e. the faces of the part are displayed.
The definition of the core and the cavity is based on a facetisation of the faces. The deviation of the
normal to a facet with the pulling direction defines whether the facet belongs to the core or the cavity. If
one facet in a face does not clearly belong to the core or the cavity, the whole face will be considered to
be "Other" and displayed in blue. In this case, it is interesting to know how all the facets of the face
behave, to decide to split the face, or to transfer it to the core or the cavity side.
Facet Display
Displays the facets on a blue face so that you can find which one(s) is (are) not compatible with the rest
of the face and solve the problem.
Faces display:
Facets display:
155 Page
Core and Cavity Design Version 5 Release 16
Explode
Displays the graphic visualizations of the Core area and of the Cavity area apart from each other, along
the current pulling direction.
156 Page
Core and Cavity Design Version 5 Release 16
G The Other area is ignored
157 Page
Core and Cavity Design Version 5 Release 16
Slider Lifter Direction Parameters
More Operating Mode information is available in the Basic Task Defining The Pulling Direction For Sliders.
Draft: Pulling Axis System
Direction
Pulling axis direction that can be defined:
G either by entering the X,Y,Z coordinates,
G or by using the compass.
It can be locked once you have set the axis system so as to avoid unintentional modifications that can be
made when you are moving/manipulating the compass.
You can use the Reverse button to reverse the pulling direction.
158 Page
Core and Cavity Design Version 5 Release 16
Locked
Lock the Pulling axis direction before using:
G the Local Transfer,
G the Fly analysis,
G the Explode option,

Fly analysis
Check this option to display the normal to the face when you move the mouse pointer over the surface.

Draft angle
Defines the minimum un-molding angle between the surface and the slider area pulling direction.
Mold Areas
Areas to extract
They are the Slider/Lifter (displayed in yellow) and Other (displayed in blue/red). Other indicates
surfaces that will be dealt with later.
159 Page
Core and Cavity Design Version 5 Release 16
Facets to ignore
If even only one facet a face is not clearly either core or cavity, the whole face will be considered to be
"other" and displayed in blue. You can use the Facet Display option to solve this problem.
One solution is to "ignore" a given percentage of those alien facets, as for the Main Pulling Direction. To
do so, check the Facets to ignore option and use the slider to define this percentage.

Connected area
Lets you choose whether you want to use all of the faces that are connected to the face you selected
(active) or all of the faces in the body, whether connected or not.
Switch
The orientation of the facets normals may lead to "inverted" Slider/Lifter and Other areas for a given
pulling direction, i.e. the expected Slider/Lifter area is recognized as an Other area, and vice-versa.
Push the switch button to invert those areas directly, without inverting the orientation of the normals nor
the pulling direction.

Local Transfer
Transfers one face of the part to one of the two areas to extract (Slider/Lifter, Other).
1. Check Local Transfer.
2. Select the area where you want to transfer the face in the list.
3. Pick the face to transfer. The face is transferred to the selected area, this transfer is taken into
account immediately.

160 Page
Core and Cavity Design Version 5 Release 16
Local Transfer
Transfers one face of the part to one of the two areas to extract (Slider/Lifter, Other).
Local transfer is available in exploded view.
1. Lock the Direction.
2. Check Local Transfer.
3. Select the area where you want to transfer the face in the list.
4. Select the kind of propagation you want to use from the list.
G No propagation: you pick the faces you want to transfer one by one.
G Point continuity: you pick one face and all the faces of the same initial color that have a point
continuity with this face will be selected and transferred.
G By area: useful when a few faces of a given color are found among the destination faces, but are not
connected to each other:
The faces selected are transferred to the destination area, this transfer is taken into account
immediately.


Should you wish to change the selection to transfer locally, press the Undo button .
161 Page
Core and Cavity Design Version 5 Release 16

Visualization
By default, Faces display is active, i.e. the faces of the part are displayed.
The definition of the slider area and the lifter area is based on a facettisation of the faces. The deviation of
the normal to a facet with the pulling direction defines whether the facet belongs to the slider area or the
lifter area. As said above, if one facet in a face does not clearly belong to the slider area or the lifter area,
the whole face will be considered to be "Other" and displayed in blue. In this case, it is interesting to know
how all the facets of the face behave, to decide to split the face, or to transfer it to the slider or the lifter
area.
Facet Display
Displays the facets on a blue face so that you can find which one(s) is (are) not compatible with the rest
of the face and solve the problem.
Faces display:
Facets display:

162 Page
Core and Cavity Design Version 5 Release 16
Explode
Displays the graphic visualizations of the Slider/Lifter area and of the Other area apart from each other,
along the current pulling direction.
163 Page
Core and Cavity Design Version 5 Release 16
Transfer an Element Parameters
More Operating Mode information is available in the Basic Task Transferring Elements.
Elements To Transfer
Propagation type
There are three ways of selecting faces based on a Propagation type:
G No propagation lets you select faces by hand in the viewer,
G Point continuity selects all the faces in the same body (core, cavity, other) that have a contact point with the selected
face,
164 Page
Core and Cavity Design Version 5 Release 16
G Tangent continuity selects all of the faces in the same body that are tangent to the selected face.
You can also use the Polygon Trap icon to select faces.
165 Page
Core and Cavity Design Version 5 Release 16

Click the places in the viewer where you want the corners of the polygon to be.
Double click to end corner definition.
All faces that are situated entirely within the polygon are selected.
G Select the type of propagation you wish to use before selecting a face.
G The elements selected take the color of the destination.
166 Page
Core and Cavity Design Version 5 Release 16
Information
The information in the dialog box is:
where
G N gives the number of the element to transfer in the list,
G Element gives the name of the element,
G Source says where the element came from before transfer,
G Destination gives the destination for the element after transfer,
G Move/Copy indicates whether the element was moved or copied from its source to its destination.
A contextual menu is available on each element :
G Reframe On: reframes the view on the selected element.
G -> Cavity, -> Core, -> Other: defines the destination of the element without selecting the destination in the
Destination list and pushing the Modify Element button.
G Modify Element: modifies the destination of the element.
G Select the destination in the Destination combo list,
G Select the element,
G Select Modify Element in the contextual menu.
Similar to the push button below.
G Remove Element: removes the element from the list. Similar to the push button below.
Options
G Move: moves the element from its source to its destination.
167 Page
Core and Cavity Design Version 5 Release 16
G Copy: keeps an instance of the element in its source and copies it to its destination.
Destination
Lists the possible destinations and displays the one selected.
168 Page
Core and Cavity Design Version 5 Release 16
Compare Models Parameters
More Operating Mode information is available in the Basic Task Comparing Two Molded Parts.
Model
Reference
Path and name of the CATPart you are going to compare with the CATPart that is already in your workbench..
Push the icon to browse your directories to the location of the CATPart.
Body
Element in the reference file that you wish to import. Use the combo list to select it.
G If the CATPart selected contains a PartBody, i.e. a solid, this PartBody is proposed by default.
G If there is no valid PartBody available, the first non-empty Geometrical set is proposed.
If you wish to import a set of faces, first press the icon (for importing closed solids) so that the icon for
importing a set of faces is displayed, , then choose your file.
Surface
169 Page
Core and Cavity Design Version 5 Release 16
Surface that you wish to use for the computation and is only displayed when you have a choice of surfaces to
use in the body. The surface proposed by default is the last surface in the Geometrical set, because it should be
the most complete surface, i.e. the most susceptible to be closed.
Axis System
Defines the origin of the Molded Part, and also the initial axis system.
The Origin position (X,Y,Z) is defined via one of the following menu options :
G Bounding box center: the origin is the center of the virtual bounding box around the part.
G Center of gravity: the origin is the center of gravity of the model.
G Coordinates: you can enter an origin and the system will be parallel to the main axis system.
G Local axis system: the origin is that of the axis system that is defined in the model you are importing.
The Axis system is generated according to the option which has been selected :
G with Local axis system: with the axis system planes of the model imported,
G with the other options: with the standard main planes.
Shrinkage
170 Page
Core and Cavity Design Version 5 Release 16
Plastic shrinkage can be allowed for either by:
G Scaling : the default Scaling ratio proposed is 1. You can modify this value. The reference point for
Scaling is the origin of the Axis System defined just before. This point cannot be modified in this frame.
G or Affinity which is defined by giving 3 axis ratios. The default Affinity ratio proposed is 1 along the 3
axes. You can modify the 3 ratios. The Axis system of the Affinity (Origin, Plane XY, Axis X) is the one
defined just before. This axis system cannot be modified in this frame.
Comparison
Pressing OK in the Compare Molded Part dialog box displays the Comparison dialog box.
Check the box for the faces that you want to display after analysis. You can choose to display one or more:
G Similar faces displays the faces that are identical in both models,
G Specific current model displays the faces that are specific to the original model,
G Specific new model displays the faces that are specific to the new model (the one that was selected in the
Compare Molded Parts dialog box).
The color slabs give the color that the corresponding faces are displayed in and allow you to differentiate the
faces on screen. You can change the colors by double clicking on the slabs and then selecting the colors you
want to use.
171 Page
Core and Cavity Design Version 5 Release 16
Tolerance gives the distance within which two faces are considered to be identical.
172 Page
Core and Cavity Design Version 5 Release 16
Split Mold Area Parameters
More Operating Mode information is available in the Basic Task Splitting a Face.
Elements to Cut
Propagation type
There are three ways of selecting faces based on a Propagation type:
G No propagation lets you select faces by hand in the viewer,
G Point continuity selects all the faces in the same body (core, cavity, other) that have a contact point
with the selected face,
G Tangent continuity selects all of the faces in the same body that are tangent to the selected face.
173 Page
Core and Cavity Design Version 5 Release 16
G Select the type of propagation you wish to use before selecting a face.
G The elements selected turn to gray.
Elements list
When you select faces either by point or tangent continuity, the dialog box indicates the number of
elements selected. Use the contextual menu Display list to display the list of elements so that you can
modify its contents. The contextual menu Reset list can also be used to clear the list.
Once the list is displayed, you can select elements in it to remove or you can clear the list.
Remove
Removes selected elements from the list.
Reset
174 Page
Core and Cavity Design Version 5 Release 16
Resets the list of selected elements.


Cutting Element
Displays the name of the element selected as a cutting element.

Element Destination
After Apply, displays the result of the split with their proposed destination.
Switch Destination
Switches the destination of the computed surfaces.
Change Destination
Becomes active when an element is selected in the list and changes its destination to that of the
Destination field.
Contextual menu
175 Page
Core and Cavity Design Version 5 Release 16
G -> Cavity, -> Core, -> Other: changes the destination of the element without selecting the
destination in the Destination list and pushing the Change Destination button.
G Change Destination: equivalent to the Change Destination button.
Destination
Lists the possible destinations and displays the one selected.


176 Page
Core and Cavity Design Version 5 Release 16
Face Orientation Parameters

The information in this section will help you check the orientation of faces and re-orient the ones that need to
be so that you can then use the model n the main pulling direction action.
More Operating Mode information is available in the Face Orientation Basic Task.


Reference Direction
Defines the direction that is used to define whether a face is correctly oriented or not.
Lock
Locks the Reference Direction so that you can perform a Fly Analysis.
Fly Analysis
Displays the normal to each face you move the cursor over.
177 Page
Core and Cavity Design Version 5 Release 16

Faces to invert
Gives information on the number of:
G faces in the model,
G faces that need to be reoriented,
G faces that do not need to be reoriented.
See below for information on how to change the colors of the slabs.
Press the button to display a list of all of the faces in the model, sorted according to their orientation and
where you can modify the selection of faces to invert.
178 Page
Core and Cavity Design Version 5 Release 16

The color slabs give the color that the corresponding faces are displayed in and allow you to differentiate the
faces on screen. You can change the colors by double clicking on the slabs and then selecting the colors you
want to use.

179 Page
Core and Cavity Design Version 5 Release 16
Bounding Box
More Operating Mode information is available in the Bounding Box Basic Task.


Axis Definition
Direction
Standard X,Y,Z orientation is the default value for this parameter.
Click on a face or an axis if you wish to change the orientation of the resulting bounding box (the coordinates
defining the bounding box are automatically displayed in the Bounding Box Definition and can be modified
by hand).
Bounding Box Size
The lengths given here are for information only and cannot be modified.
180 Page
Core and Cavity Design Version 5 Release 16
Glossary


A
aggregation
Aggregation is the recovery of the topological connections which existed in the original
molded part prior to successive transfer of some faces in a new Geometrical set.

C
cavity area
Area that can be removed from the mold in the pulling direction.
core area
Area that can be removed from the mold in the direction opposite to the pulling direction.
F
flag note A hyperlink.
L
lifter A mobile part designed to facilitate the removal of parts with hollow inside areas from the
mold.
P
parting line
The outer boundary of the molded part where no undercut is found.
parting surface
The surface delimiting the separation between core area and cavity area.
powercopy
A set of features that are grouped in order to be used in a different context and that can
be re-specified according to the context when pasted.

pulling direction Direction of removal from the mold.
S
slider
A mobile part designed to facilitate the removal of parts with draft surfaces from the mold.
split
the operation consisting in generating the parting surface on the core and cavity.

U
undercut
Area that can not be removed from the mold.
181 Page
Core and Cavity Design Version 5 Release 16

182 Page
Core and Cavity Design Version 5 Release 16
Index

A
Affinity
Compare
Import model
Aggregate
command
Create a join datum
analyzing
curvature
Areas to extract
Defining a pulling direction for slider areas
Defining the main pulling direction
B
Blend
command
Body
Compare
Import model
Boundary
command
Bounding Box
Bounding Box Definition
Bounding Box Size
Direction
Bounding Box Center
Compare
Import model
Bounding Box Definition
183 Page
Core and Cavity Design Version 5 Release 16
Bounding Box
Bounding Box Size
Bounding Box
C
Cavity
Split a mold area
Transfer elements
Center of Gravity
Compare
Import model
Change Destination
Split a mold area
changing position
section plane(s)
color scale
Command
Explode View
command
Aggregate
Blend
Boundary
Clash Detection
Create a connecting curve
Create a curve
Create a parallel curve
Defines pulling direction
Definition...
Edge Fillet
Edit Grid
Edit Main Pulling Direction
Edit Position and Dimensions
184 Page
Core and Cavity Design Version 5 Release 16
Extract a face or a surface edge
Extrapolate
Extrude
Face Orientation
Face-Face Fillet
Fill
Flag Note with Leader
Flip Horizontal
Flip Vertical
Geometrical Target
Grid
Import model
Instantiate from document
Intersection
Invert Normal
Join curves or surfaces
Line
Loft
Parting surface
Plane
Point
PowerCopy Creation
Project a point or curve
ReflectLine
Reset Position
Rotate
Rotate Left
Rotate Right
Save in Catalog
Section Fill
Sectioning
Sectioning...
185 Page
Core and Cavity Design Version 5 Release 16
Set as current axis system
Shape Fillet
Slider Lifter Direction
Smooth Edges
Split
SplitMoldArea
Surface Boundaries...
Surfacic Curvature Analysis
Sweep
Symmetry
Text with Leader
Transfer an element
Translate
Trim
Tritangent Fillet
Untrim Surface or Curve
Update Main Pulling Direction
Variable Radius Fillet
Volume Cut
Compare
Affinity
Body
Bounding Box Center
Center of Gravity
Coordinates
Local Axis System
Reference
Scaling
Shrinkage
Similar faces
Specific current model
Specific new model
186 Page
Core and Cavity Design Version 5 Release 16
Surface
Tolerance
Complementary
Parting surface
Connected area
Defining a pulling direction for slider areas
Contextual menu
Split a mold area
Coordinates
Compare
Import model
Copy
Transfer elements
Core
Split a mold area
Transfer elements
Create a connecting curve
command
Create a curve
command
Create a join datum
Aggregate
Create a parallel curve
command
creating
section cut(s)
section plane(s)
Cutting Element
Split a mold area
D
Defines pulling direction
command
Defining a pulling direction for slider areas
Areas to extract
187 Page
Core and Cavity Design Version 5 Release 16
Connected area
Direction
Draft angle
Explode
Faces display
Facet Display
Fly analysis
Local Transfer
Locked
Progress bar
Reverse
Switch
Undo
Defining a pulling direction for sliders
Defining the main pulling direction
Areas to extract
Direction
Draft angle
Explode
Faces display
Facet Display
Facets to ignore
Fly analysis
Local Transfer
Locked
Progress bar
Reverse
Switch
Undercut
Undo
Definition...
command
188 Page
Core and Cavity Design Version 5 Release 16
Destination
Split a mold area
Transfer elements
detecting
collisions between 2D sections
Direction
Bounding Box
Defining a pulling direction for slider areas
Defining the main pulling direction
Direction Definition
Parting surface
Display list
Split a mold area
Draft angle
Defining a pulling direction for slider areas
Defining the main pulling direction
E
Edge Fillet
command
Edit Grid command
Edit Main Pulling Direction
command
Edit Position and Dimensions command
Element
Transfer elements
Element Destination
Split a mold area
Elements list
Split a mold area
Elements to Cut
Split a mold area
Elements to Transfer
Transfer elements
Explode
189 Page
Core and Cavity Design Version 5 Release 16
Defining a pulling direction for slider areas
Defining the main pulling direction
Explode Value
Explode View
Explode View
Command
Explode Value
Pulling direction
Reset
Extract a face or a surface edge
command
Extrapolate
command
Extrude
command
Extrusion
Parting surface
F
Face Orientation
command
Faces list
Faces to invert
Fly Analysis
Lock
Parameters
Reference Direction
Face-Face Fillet
command
Faces display
Defining a pulling direction for slider areas
Defining the main pulling direction
Faces list
190 Page
Core and Cavity Design Version 5 Release 16
Face Orientation
Faces to invert
Face Orientation
Facet Display
Defining a pulling direction for slider areas
Defining the main pulling direction
Facets to ignore
Defining the main pulling direction
Fill
command
Flag Note with Leader
command
Flip Horizontal command
Flip Vertical command
Fly Analysis
Face Orientation
Fly analysis
Defining a pulling direction for slider areas
Defining the main pulling direction
G
Geometrical Target command
Grid command
I
Import model
Affinity
Body
Bounding Box Center
Center of Gravity
command
191 Page
Core and Cavity Design Version 5 Release 16
Coordinates
Local Axis System
Reference
Scaling
Shrinkage
Surface
Information
Transfer elements
Instantiate from document
command
Intersection
command
Invert Normal command
J
Join curves or surfaces
command
Join parting surface
Parting surface
L
Line
command
Local Axis System
Compare
Import model
Local Transfer
Defining a pulling direction for slider areas
Defining the main pulling direction
Lock
Face Orientation
Locked
192 Page
Core and Cavity Design Version 5 Release 16
Defining a pulling direction for slider areas
Defining the main pulling direction
Loft
command
M
Main Pulling Direction contextual menu
manipulating
section plane(s)
Maximum deviation
Parting surface
Merging distance
Parting surface
Modify Element
Transfer elements
Move
Transfer elements
Move/Copy
Transfer elements
moving
section plane(s)
N
No propagation
Split a mold area
Transfer elements
O
Other
Split a mold area
Transfer elements
193 Page
Core and Cavity Design Version 5 Release 16
P
Parameters
Face Orientation
Parting surface
command
Complementary
Direction Definition
Extrusion
Join parting surface
Maximum deviation
Merging distance
Profile Definition
Reference
Up to sketch
Vertex
Plane
command
Point
command
Point continuity
Split a mold area
Transfer elements
Polygon Trap
Transfer elements
positioning
section planes along a curve or edge
section planes on geometrical target
section planes using the Edit Position and Dimensions command
PowerCopy Creation
command
Profile Definition
Parting surface
194 Page
Core and Cavity Design Version 5 Release 16
Progress bar
Defining a pulling direction for slider areas
Defining the main pulling direction
Transfer elements
Project a point or curve
command
Propagation type
Split a mold area
Transfer elements
Pulling direction
Explode View
R
re-dimensioning
section plane(s)
Reference
Compare
Import model
Parting surface
Reference Direction
Face Orientation
ReflectLine
command
Reframe On
Transfer elements
Remove
Split a mold area
Remove Element
Transfer elements
Reset
Explode View
Split a mold area
Reset list
Split a mold area
195 Page
Core and Cavity Design Version 5 Release 16
Reset Position command
results window
sectioning
Reverse
Defining a pulling direction for slider areas
Defining the main pulling direction
Rotate
command
Rotate Left command
Rotate Right command
rotating
section plane(s)
S
Save in Catalog
command
Scaling
Compare
Import model
section cut(s)
creating
section plane(s)
along a curve or edge
changing position
creating
manipulating
moving
on geometrical target
re-dimensioning
rotating
using the Edit Position and Dimensions command
sectioning
about
196 Page
Core and Cavity Design Version 5 Release 16
collision detection
creating section planes
results window
Sectioning command
Sectioning...
command
Set as current axis system
command
Shape Fillet
command
Shrinkage
Compare
Import model
Similar faces
Compare
Slider Lifter Direction
command
Smooth Edges
command
Source
Transfer elements
Specific current model
Compare
Specific new model
Compare
Split
command
Split a mold area
Cavity
Change Destination
Contextual menu
Core
Cutting Element
Destination
Display list
197 Page
Core and Cavity Design Version 5 Release 16
Element Destination
Elements list
Elements to Cut
No propagation
Other
Point continuity
Propagation type
Remove
Reset
Reset list
Switch Destination
Tangent continuity
SplitMoldArea
command
Splitting a face
Surface
Compare
Import model
Surface Boundaries...
command
surfacic Curvature Analysis
Sweep
command
Switch
Defining a pulling direction for slider areas
Defining the main pulling direction
Switch Destination
Split a mold area
Symmetry
command
T
Tangent continuity
198 Page
Core and Cavity Design Version 5 Release 16
Split a mold area
Transfer elements
Text with Leader
command
Tolerance
Compare
Transfer an element
command
Transfer elements
Cavity
Copy
Core
Destination
Element
Elements to Transfer
Information
Modify Element
Move
Move/Copy
No propagation
Other
Point continuity
Polygon Trap
Progress bar
Propagation type
Reframe On
Remove Element
Source
Tangent continuity
Transferring elements
Translate
command
Trim
command
199 Page
Core and Cavity Design Version 5 Release 16
Tritangent Fillet
command
U
Undercut
Defining the main pulling direction
Undo
Defining a pulling direction for slider areas
Defining the main pulling direction
Untrim Surface or Curve
command
Up to sketch
Parting surface
Update Main Pulling Direction
command
V
Variable Radius Fillet
command
Vertex
Parting surface
viewer
sectioning
Volume Cut command
200 Page
Core and Cavity Design Version 5 Release 16

Você também pode gostar