Você está na página 1de 13

VSL MULTISTRAND SYSTEMS:

Strand and Tendon Properties


Strand Properties

0.5
(13 mm)

Strand Type
inch
inch2
lbs/ft
ksi
kips
ksi
%

Nominal diameter
Nominal area
Nominal weight/mass
Tensile strength
Min. breaking load
Youngs modulus
Relaxation

Tendon Properties

0.5
0.6
0.153
0.217
0.53
0.74
270
270
41.3
58.6
approx. 28,500
max 2.5

Strands Type 0.5 (270 ksi)


Number of
Strands Per
Tendon
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

0.6
(15 mm)

Area of tendon
inch2

Min breaking
load kips

0.15
0.31
0.46
0.61
0.77
0.92
1.07
1.22
1.38
1.53
1.68
1.84
1.99
2.14
2.30
2.45
2.60
2.75
2.91
3.06
3.21
3.37
3.52
3.67
3.83
3.98
4.13
4.28
4.44
4.59
4.74
4.90
5.05
5.20
5.36
5.51
5.66
5.81
5.97
6.12
6.27
6.43
6.58
6.73
6.89
7.04
7.19
7.35
7.50
7.65
7.80
7.96
8.11
8.26
8.42

41.3
82.6
123.9
165.2
206.5
247.8
289.1
330.4
371.7
413.0
454.3
495.6
536.9
578.2
619.5
660.8
702.1
743.4
784.7
826.0
867.3
908.6
949.9
991.2
1032.5
1073.8
1115.1
1156.4
1197.7
1239.0
1280.3
1321.6
1362.9
1404.2
1445.5
1486.8
1528.1
1569.4
1610.7
1652.0
1693.3
1734.6
1775.9
1817.2
1858.5
1899.8
1941.1
1982.4
2023.7
2065.0
2106.3
2147.6
2188.9
2230.2
2271.5

www.vsl.net
888-489-2687

Strands Type 0.6 (270 ksi)


Number of
Strands Per
Tendon
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55

Area of tendon
inch2

Min breaking
load kips

0.22
0.43
0.65
0.87
1.09
1.30
1.52
1.74
1.95
2.17
2.39
2.60
2.82
3.03
3.26
3.47
3.69
3.91
4.12
4.34
4.56
4.78
4.99
5.21
5.43
5.64
5.86
6.08
6.29
6.51
6.73
6.94
7.16
7.38
7.60
7.81
8.03
8.25
8.46
8.68
8.90
9.11
9.33
9.55
9.77
9.98
10.20
10.42
10.63
10.85
11.07
11.28
11.50
11.72
11.94

58.6
117.2
175.8
234.4
293.0
351.6
410.2
468.8
527.4
586.0
644.6
703.2
761.8
820.4
879.0
937.6
996.2
1054.8
1113.4
1172.0
1230.6
1289.2
1347.8
1406.4
1465.0
1523.6
1582.2
1640.8
1699.4
1758.0
1816.6
1875.2
1933.8
1992.4
2051.0
2109.6
2168.2
2226.8
2285.4
2344.0
2402.6
2461.2
2519.8
2578.4
2637.0
2695.6
2754.2
2812.8
2871.4
2930.0
2988.6
3047.2
3105.8
3164.4
3223.0

VSL US Technical Data and Dimensions Strand and Tendon Properties 0308 VStructural, LLC

VSL MULTISTRAND SYSTEMS:

Type ECI Stressing Anchorage

Dimensions (Inches)
E

F
PT+
Duct

F
Steel
Duct

F
SCH 40
Pipe

8.54
8.54

6.69 2.37 5.33 3.31


6.69 2.37 5.33 3.31

2.87
2.87

2.88
2.88

3.00
3.00

11.00 12.00
11.00 12.00

3500
5500

9.88
9.88

8.66 3.00 6.85 4.62


8.66 3.00 6.85 4.62

3.58
3.58

3.24
3.24

3.50
3.50

13.00 14.00
13.00 13.50

3500
5500

11.42 6.91 3.75 8.13 5.90


11.42 6.91 3.75 8.13 5.90

4.57
4.57

4.10
4.10

4.50
4.50

17.00 19.00
15.00 17.00

Tendon
Unit

fci
(psi)

6-7
6-7

3500
5500

6-12
6-12
6-19
6-19

K
PT+
Duct

K
Steel
Duct

K
SCH 40
Pipe

No Trumpet on 6-7

#4
#4

6.50
6.50

3.00
3.00

7.40
7.40

4.17
4.17

13.00
13.00

No Trumpet on 6-12

#5
#4

7.00
7.00

3.00
3.00

8.66
8.66

4.90
4.90

15.00
15.00

#5
#5

11.50
10.50

2.00
2.00

10.24
10.24

5.63
5.63

19.00
17.00

15.19
15.19

12.09
12.09

9.29
9.29

Notes:
Anchorage spacings are in accordance with test requirement of AASHTO (The Special
Anchorage Device Acceptance Test Procedure, AASHTO 2000).
For proper design and detailing of anchorage zones and related reinforcement, refer to the
VSL Publication Detailing for Post-Tensioning.

www.vsl.net 888-489-2687

Dimensions are valid for:


fci (psi) is the nominal minimum concrete cylinder strength at the time of stressing.
Maximum prestressing force may be applied when concrete reaches a cylinder
strength of 3,500 psi (24 MPa) and 5,500 psi (38 MPa) respectively.
Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.
Yield strength of spiral reinforcement: Grade 60 (400 MPa).
Tie one and one-half turns of spiral at both ends.
Additional orthogonal reinforcement may be required in the local anchorage zone as
determined by design.
Spirals may be replaced by suitable orthogonal reinforcement.
Information for other concrete strengths and conditions is available from your local
VSL Representative.
Spiral reinforcement shall be centered on the anchorage assembly and be placed
directly behind the bearing plate as indicated above.
VSL US Technical Data and Dimensions ECI Multistrand 1207 VStructural, LLC

Multistrand Post-Tensioning

VSL

Stressing Anchorage VSL Type ES

K (super)
~1.25"

K (std)

Spiral reinforcement
L x n turns (pitch = H/n)

X = Anchorage spacing
XR = Clearence to edge
XR = 12 X + required cover of
spiral reinforcing

Drawings not to scale

Tendon Unit

Dimensions Inches
C

(std)

(super)

Strand
Type 0.5''

5-12
5-19
5-31
5-43
5-55

8.74
10.16
12.60
15.35
16.54

2.36
3.15
3.94
4.72
5.12

2.38
3.00
4.00
5.20
5.50

6.00
7.00
9.00
11.10
12.00

4.06
5.13
6.59
8.57
9.01

10.50
13.75
18.00
21.75
24.75

10.00
14.00
18.00
20.00
22.50

4.33
4.82
5.91
7.24
7.80

13.00
16.93
19.69
28.75
27.55

16.38
20.22
23.86
NA
NA

#4
#5
#5
#5
#6

5
7
9
10
10

12.50
15.75
20.50
23.75
26.75

Strand
Type 0.6''

6-7
6-12
6-19
6-22
6-31
6-37

8.74
10.16
11.81
12.60
15.35
16.54

2.36
3.15
3.54
3.94
4.72
5.12

2.38
3.25
3.75
4.00
5.20
5.50

6.00
7.00
8.25
9.00
11.10
12.00

4.06
5.13
5.88
6.59
8.57
9.01

10.50
13.75
17.00
18.00
21.75
24.75

10.00
14.00
18.00
18.00
20.00
22.50

4.33
4.82
5.61
5.91
7.24
7.80

13.00
16.93
19.69
19.69
28.75
27.55

16.38
20.22
22.13
23.86
NA
NA

#4
#5
#5
#5
#5
#6

5
7
9
9
10
10

12.50
15.75
19.00
20.50
23.75
26.75

Other sizes available on request


Anchorage spacings are in accordance with test requirements of FIP
(Recommendations for Acceptance of Post-Tensioning Systems: March
1992). For proper design and detailing of anchorage zones and related
reinforcement, refer to the VSL Publication Detailing for Post-Tensioning.
Dimensions are valid for:
Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa).
Maximum prestressing force may be applied when concrete reaches
a cylinder strength of 3,500 psi (24 MPa).

Subject to modification
Additional orthogonal reinforcement may be required in the local
anchorage zone as determined by design.
Spirals may be replaced by suitable orthogonal reinforcement.
Information for other concrete strengths and conditions are available from
your local VSL Representative.
Spiral reinforcement shall be centered on the anchorage assembly and be
placed directly behind the bearing plate.

Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.


Yield strength of spiral reinforcement: Grade 60 (400 MPa).

VSL/DSUS_Multi_SA_ES

1M 5/02 VStructural, LLC

www.vsl.net

Multistrand Post-Tensioning

VSL

Stressing Anchorage VSL Type EC

~1.25"
C

X = Anchorage spacing
XR = Clearence to edge

Spiral reinforcement
L x n turns (pitch = H/n)

XR = 12 X + required cover of
spiral reinforcing

Strand
Type 0.5''

Tendon Unit
5-7
5-12
5-19
5-27
5-31

Dimensions Inches
A

6.50
8.88
11.00
12.38
14.00

5.25
7.06
10.25
13.63
13.63

2.38
2.38
3.00
4.00
4.00

4.50
6.00
7.00
9.00
9.00

2.91
4.31
5.56
7.00
7.00

2.50
3.13
3.75
4.75
4.75

9.00
11.75
15.00
18.00
19.00

12.00
16.00
18.00
18.00
20.25

#4
#4
#5
#6
#6

6
8
8
8
9

9.50
12.50
15.75
18.75
20.00

Other sizes available on request


Anchorage spacings are in accordance with test requirements of FIP
(Recommendations for Acceptance of Post-Tensioning Systems: March
1992). For proper design and detailing of anchorage zones and related
reinforcement, refer to the VSL Publication Detailing for Post-Tensioning.
Dimensions are valid for:
Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa).
Maximum prestressing force may be applied when concrete reaches
a cylinder strength of 3,500 psi (24 MPa).

Subject to modification
Yield strength of spiral reinforcement: Grade 60 (400 MPa).
Spirals may be replaced by suitable orthogonal reinforcement.
Information for other concrete strengths and conditions are available
from your local VSL Representative.
Spiral reinforcement shall be centered on the anchorage assembly and
be placed directly behind the bearing plate.
Additional orthogonal reinforcement may be required in the local
anchorage zone as determined by design.

Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.

VSL/DSUS_Multi_SA_EC

1M 5/02 VStructural, LLC

www.vsl.net

VSL MULTISTRAND SYSTEMS:

Type E Stressing Anchorage


Stressing Anchorage VSL Type E

~1.25"
C

Spiral reinforcement
L x n turns (pitch = H/n)

X = Anchorage spacing
XR = Clearance to edge
XR =

Bearing Plate
(Steel)

Grout Hose

+ required cover of
spiral reinforcing

Dimensions (Inches)
Tendon Unit

0.5
Strand

5-1
5-3
5-4
5-7
5-12
5-19
5-22
5-31
5-37
5-43
5-55

2.76
4.53
5.12
6.89
9.06
11.42
12.40
14.57
15.94
17.32
19.69

0.59
0.79
0.79
0.98
1.38
1.57
1.77
2.17
2.36
2.36
2.76

0.6
Strand

6-1
6-2
6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37
6-43
6-55

2.95
4.33
5.31
6.30
8.07
10.63
13.39
14.57
17.13
18.90
20.47
22.83

0.59
0.59
0.79
0.98
1.38
1.57
1.97
2.17
2.56
2.76
2.95
3.54

Duct

Trumpet
Anchor Head

www.vsl.net 888-489-2687

1
2X

J 2)

1.77 1.65 0.59


1.97 3.54 1.97
1.97 3.74 2.17
2.17 4.33 2.91
2.36 5.91 4.09
2.95 7.09 5.31
3.35 7.48 5.91
3.74 9.06 6.77
4.13 9.45 7.40
4.33 10.24 8.50
5.12 11.42 9.06

2.76
7.48
7.48
7.48
14.57
18.50
18.90
21.65
22.44
26.77
26.77

3.15
5.12
6.30
8.07
11.22
14.37
15.55
18.50
20.08
21.65
24.41

3.54
5.91
5.91
7.87
9.84
11.81
14.17
15.75
16.54
18.90
21.26

0.98
1.57
1.77
2.17
2.56
3.15
3.35
3.94
4.72
5.12
5.51

1.18
1.17
1.97
2.36
2.83
3.43
3.62
4.21
5.00
5.39
5.91

#3
#4
#4
#4
#4
#5
#6
#5
#7
#7
#7

2
3
3
4
5
6
6
8
7
8
9

3.54
6.10
7.09
9.25
12.01
15.16
16.34
19.29
21.06
22.83
25.79

1.97
1.97
1.97
2.17
2.36
2.95
3.74
3.94
4.72
5.31
5.71
6.30

2.76
7.48
7.48
7.48
11.42
18.11
23.23
27.17
27.17
32.68
37.40
37.40

3.15
5.12
6.30
7.48
10.24
13.58
17.32
18.50
22.05
24.02
25.59
29.13

3.54
5.91
5.91
7.87
9.84
11.81
13.78
15.75
18.90
21.26
25.20
24.80

1.18
1.77
1.77
1.97
2.36
3.15
3.74
4.33
5.12
5.51
5.91
6.69

1.38
1.97
1.97
2.17
2.64
3.43
4.02
4.61
5.39
5.91
6.30
7.09

#3
#4
#4
#4
#4
#5
#5
#6
#7
#7
#8
#8

2
3
3
4
5
6
9
8
8
9
8
9

4.13
5.91
7.28
8.27
11.02
14.37
18.11
19.49
23.23
25.20
27.17
30.71

2.09
3.54
3.74
4.33
5.31
6.69
7.87
8.66
10.24
11.02
11.81
13.39

0.71
1.97
2.20
2.56
3.31
4.65
5.91
6.77
7.56
8.46
9.69
10.04

Notes:
Other sizes available on request.
Anchorage spacings are in accordance with test requirements of FIP (Recommendations for Acceptance of Post-Tensioning Systems: March 1992). For proper
design and detailing of anchorage zones and related reinforcement, refer to the VSL Publication Detailing for Post-Tensioning.
Dimensions are valid for:
Nominal minimum concrete cylinder strength at 28 days: 4000 psi (28 MPa).
Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500 psi (24 MPa).
Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.
Yield strength of spiral reinforcement: Grade 60 (400 MPa).
Information for other concrete strength and conditions are available from your local VSL Representative.
Large bearing plates are available where bearing stress is arbitrarily limited to 3,000 psi (21 MPa) with the tendon locked off at 70% Guaranteed Ultimate Tensile
Strength.
Spiral reinforcement shall be centered on the anchorage assembly and be placed directly behind the bearing plate.
Additional orthogonal reinforcement may be required in the local anchorage zone as determined by design.
VSL US Technical Data and Dimensions E Multistrand 0308 VStructural, LLC

VSL MULTISTRAND SYSTEMS:

Type K Coupler

Dimensions (Inches)
Tendon Unit

Grout Hose
Coupling
Head K

0.5
Strand

5-3
5-7
5-12
5-19
5-22
5-31
5-37
5-42
5-55

16.93
21.65
25.59
29.13
32.68
44.88
51.97
50.79
53.94

5.51
5.51
5.51
5.51
5.51
5.51
7.09
7.09
7.87

1.57
2.36
2.36
3.15
3.54
3.54
4.72
5.12
5.91

5.12
6.69
7.87
9.45
10.24
13.78
15.35
15.55
16.54

0.6
Strand

6-2
6-3
6-4
6-7
6-12
6-19
6-22
6-31
6-37

14.96
19.29
20.47
24.80
28.74
33.86
36.61
42.91
54.72

5.91
6.30
6.30
6.30
6.30
6.30
6.30
7.09
7.87

1.18
2.36
2.36
2.76
3.15
3.54
3.54
5.12
5.12

5.51
5.91
6.30
7.48
9.45
11.02
12.20
14.17
16.93

Bearing Plate
Type EC, ES or E
Duct

Notes:
Tension ring required as shown.
Refer to applicable systems data sheet for bearing plate data and dimensions.
Use of couplers requires special procedures and detailing. Contact your local
VSL Representative.

Trumpet

Tension Ring

Compression
Fittings

www.vsl.net 888-489-2687
VSL US Technical Data and Dimensions K Multistrand 0308 VStructural, LLC

VSL MULTISTRAND SYSTEMS:

Type T Dead-End Anchorage

Spiral reinforcement
L x n turns (pitch = H/n)

Tension Ring

X = Anchorage spacing
XR = Clearance to edge
XR =

X + required cover of
spiral reinforcing

Dimensions (Inches)
Tendon Unit

11.75
15.00
19.00

12.50
15.75
20.00

0.5
Strand

5-12
5-19
5-31

6.60
11.00
16.00

8.80
11.00
11.00

36.00
36.00
36.00

0.6
Strand

6-7
6-12
6-19

6.75
6.75
9.00

6.75
6.00
11.25

36.00
36.00
36.00

12.50
15.75
20.00

Notes:
Grout Hose

Tension Ring

Duct

Seal

Anchorage spacings are in accordance with test requirement of AASHTO (The Special Anchorage
Device Acceptance Test Procedure, AASHTO 2000).
For proper design and detailing of anchorage zones and related reinforcement, refer to the VSL
Publication Detailing for Post-Tensioning.

Dimensions are valid for:

Nominal minimum concrete cylinder strength at 28 days: 4000 psi (28 MPa).
Maximum prestressing force may be applied when concrete reaches a cylinder strength of 3,500
psi (24 MPa).
Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.
Information for other concrete strength and conditions are available from your local VSL
Representative.

Type T Anchorage

www.vsl.net 888-489-2687
VSL US Technical Data and Dimensions T Multistrand 0308 VStructural, LLC

VSL MULTISTRAND SYSTEMS:

Type Z Intermediate Anchorage

VSL Type Z Anchorage

VSL Type Z Anchorage


Stressing Jack
Stressing Jack
Curved stressing chair
Curved stressing chair

VSL Type Z Anchorage

F+L

Tendon #1

G+L

Tension Ring

Tendon #2
Tendon #2

LE
= Elongation
of tendon
#2
=BC/2 + required
cover
Tendon #1
E = C/2 + required cover

L = Elongation of tendon #2
G+L

Tendon #1

B
G+L

F+L

Tendon #2
Curved stressing
Tendon
#2chair
Tension Ring

F+L

Stressing Jack

Tendon #2

Tendon #1

Dimensions (Inches)
#2

Tendon Unit

F2

G2

0.5
Strand

5-2 1)
5-4 1)
5-6
5-8
5-12
5-22

5.12
6.30
7.87
8.62
11.02
13.78

2.36
2.76
3.54
4.12
5.51
6.69

3.15
3.54
5.12
4.50
5.51
7.87

2.36
2.56
3.35
3.00
3.54
4.72

15.75
19.69
23.62
29.50
39.37
57.09

22.05
28.35
35.04
46.38
56.69
81.50

6.69
7.87
9.45
10.25
12.60
15.35

0.6
Strand

6-2 1)
6-4 1)
6-6
6-12
6-22

5.51
6.69
8.27
11.81
15.75

2.76
3.15
3.94
6.30
7.48

3.54
3.94
5.51
6.30
9.84

2.56
2.76
3.54
3.94
5.71

17.72
35.43
39.37
53.15
59.06

24.41
44.49
51.97
75.20
90.16

7.09
8.27
9.84
13.39
17.32

Notes:
Grout Hose

Tension Ring
with Anchors

Anchor Head
Type Z

Duct

Tension ring required on #2 side of the anchorage.


Blockout dimensions dependent upon the shape of the
concrete surface and the tendon elongation.
The values stated apply for surfaces which are not curved.

Retainer Plate

www.vsl.net 888-489-2687
VSL US Technical Data and Dimensions Z Multistrand 0308 VStructural, LLC

Multistrand Post-Tensioning

VSL

Dead-End Anchorage VSL Type L

Hairpin bar reinforcement

Strand
Type 0.5''

Tendon Unit

Dimensions Inches
A Internal

5-7
5-12
5-19
5-31

2.62
3.50
3.94
5.75

A External
2.88
3.75
4.19
6.00

R min.
24.00
36.00
36.00
36.00

Other sizes available on request


For proper design and detailing of anchorage zones and related
reinforcement, refer to the VSL Publication Detailing for Post-Tensioning.
Dimensions are valid for:
Nominal concrete cylinder strength at 28 days: 4,000 psi (28 MPa).
Maximum prestressing force may be applied when concrete reaches
a cylinder strength of 3,500 psi (24 MPa).

Subject to modification
Yield strength of spiral reinforcement: Grade 60 (400 MPa).
Custom size VSL Loops are available.
Information for other concrete strengths and conditions are available from
your local VSL Representative.
Simultaneous stressing of both tendon ends is necessary.

Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.

VSL/DSUS_Multi_DEA_L

1M 5/02 VStructural, LLC

www.vsl.net

VSL MULTISTRAND SYSTEMS:

Type AF Dead-End Anchorage


F

2nd injection

Overflow of
1st. injection

1st. injection
X = Anchorage spacing
XR = Clearance to edge

A
Spiral reinforcement
L x n turns (pitch = H/n)

Dimensions (Inches)
Tendon Unit
0.6
Strand

6-12
6-19
6-31

F
Int.

10.43
12.40
14.76

2.36
2.36
2.36

18.11
18.11
25.98

3.54
3.54
3.54

3.74
4.72
5.91

4.02
5.00
6.18

14.96
18.90
24.41

17.72
21.26
25.98

27.56
27.56
35.43

#5
#6
#7

9.00
9.00
12.00

2.36
2.36
3.15

16.00
20.00
26.00

Notes:
Anchorage spacings are in accordance with test requirement of AASHTO (The Special
Anchorage Device Acceptance Test Procedure, AASHTO 2000).
For proper design and detailing of anchorage zones and related reinforcement, refer to
the VSL Publication Detailing for Post-Tensioning.

Duct

Cover Plate

F (2)
Ext.

Trumpet

Strand

Dimensions are valid for:


Nominal minimum concrete cylinder strength at 28 days: 4000 psi (28 MPa).
Maximum prestressing force may be applied when concrete reaches a cylinder strength
of 3,500 psi (24 MPa).
Temporary overstressing to 80% of Guaranteed Ultimate Tensile Strength.
Yield strength of spiral reinforcement: Grade 60 (400 MPa).
Spirals may be replaced by suitable orthogonal reinforcement.
Information for other concrete strength and conditions are available from your local VSL
Representative.

www.vsl.net 888-489-2687
VSL US Technical Data and Dimensions AF Multistrand 0308 VStructural, LLC

VSL MULTISTRAND SYSTEMS:

PT-Plus Duct

Ducts PT-Plus System

Polypropylene (PP) Plastic Duct

Ducts PTPlus System

www.vsl.net 888-489-2687
H

59mm
76mm
100mm
115mm
130mm
150mm

Unit

1.5

D
A

Type

Grout/vent
connection

0.88

Dimensions (Inches)

0.6

6-7
6-12
6-19 / 22
6-27
6-31 / 37
6-43 / 55

2.28
2.99
3.94
4.53
5.12
5.91

2.48
3.19
4.17
4.76
5.35
6.18

2.87
3.58
4.57
5.16
5.75
6.57

0.10
0.10
0.12
0.12
0.12
0.14

1.65
2.00
2.00
2.36
2.00
2.36

3.23
3.94
4.84
5.43
6.14
6.89

4.25
4.57
4.96
5.00
5.47
4.96

4.17
4.88
5.79
5.83
6.97
7.28

Eccentricity of the Center of Gravity of Strands

Duct

System

Eccentricity

Offset 1

Offset 2

59mm
76mm
100mm
100mm
115mm
130mm
130mm
150mm
150mm

6-7
6-12
6-19
6-22
6-27
6-31
6-37
6-43
6-55

0.36
0.48
0.72
0.57
0.75
0.99
0.77
1.11
0.72

0.88
1.11
1.37
1.51
1.63
1.73
1.95
1.99
2.37

1.60
2.08
2.81
2.66
3.13
3.71
3.48
4.20
3.82

VSL US Technical Data and Dimensions Multistrand Duct 0708 VStructural, LLC

Multistrand Post-Tensioning

VSL

Block Out Dimensions and Clearance Requirement


Strand proje

ction B

Concrete cover according


to applicable standard

Jack Type

A min.

ZPE-23FJ
ZPE-30
ZPE-3
ZPE-60
ZPE-7A
ZPE-12St2
ZPE-200
ZPE-19
ZPE-460/31
ZPE-500
ZPE-750
ZPE-1000
ZPE-1250

1.18
1.18
1.18
1.18
1.97
1.97
1.97
2.36
3.15
3.15
3.15
3.54

12.00
24.00
22.00
26.00
32.00
28.00
44.00
34.00
28.00
46.00
54.00
52.00
54.00

47.25
43.50
39.50
43.50
47.25
51.25
82.75
59.25
59.25
78.75
90.75
86.75
88.75

4.57
5.51
7.87
7.09
11.81
12.20
12.99
15.35
19.09
23.03
22.44
31.10
25.98

3.50
4.00
6.00
5.50
8.00
8.00
8.25
10.00
12.00
13.00
14.50
17.75
14.75

Dimensions in inches.

VSL/DSUS_Multi_Block/Clear+

1M 5/02 VStructural, LLC

www.vsl.net 11

Multistrand Post-Tensioning

VSL

Stressing Jack Data

Type I (ZPE-23FJ)

Type II (ZPE-19)

Designation
Type
Length
(in)
Diameter
(in)
Stroke
(in)
Piston area (in^2)
Capacity
(kips)
Pressure
(psi)
Weight
(lb)
Used for 13 mm
(0.5'') tendon types
Used for 15 mm
(0.6'') tendon types

Type III (ZPE-500)

ZPE-23FJ

ZPE-30

ZPE-3

ZPE-60

ZPE-7A

III

III

III

III

31.10
4.57
7.87
7.30
52
7078
51
5-1

28.35
5.51
9.84
9.04
72
7963
62
5-1

18.70
7.87
6.30
16.06
112
7005
104
5-2, 5-3

6-1

6-1

6-2

ZPE-12St2 ZPE-200

II

III

24.21
27.17
21.65
37.80
7.09
11.02
12.20
12.40
9.84
6.30
3.94
11.81
19.59
31.56
47.96
50.48
142
239
416
450
7252
7585
8673
8905
163
254
333
672
5-2
5-6, 5-7 5-12
5-12
to 5-4
6-2, 6-3
6-4
6-6, 6-7 6-6, 6-7

ZPE-19

ZPE-460/31 ZPE-500

ZPE-750

ZPE-1000

II

II

III

II

III

29.53
15.35
3.94
77.55
652
8412
648
5-18
5-19
6-12

22.83
19.09
3.94
124.62
1048
8412
959
5-22
5-31
6-18,
6-19

39.37
21.65
7.87
138.66
1124
8108
2346
5-22
5-31
6-18
to 6-22

46.65
20.47
5.91
193.29
1686
8717
2425
5-31
5-37
6-31

47.24
31.10
7.87
280.47
2248
8021
5049
5-37
to 5-55
6-31
to 6-43

Other sizes available on request

VSL/DSUS_Multi_Jacks

1M 5/02 VStructural, LLC

www.vsl.net 12