Você está na página 1de 3

SC code aficio 3260C

Code Description Causes


SC101
Exposure lamp error
The white level peak did not reach the
prescribed threshold when the white
plate was scanned.
Dirty optics Exposure lamp
defective Exposure lamp does not
turn on Lamp stabilizer defective
Hih voltae line leak !ower"sinal
harness defective
SC120
#canner home position error $
The scanner home position sensor
did not detect the home position %did
not o &''( after the scanner moved
forward )* mm.
#canner motor driver board
defective #canner motor defective
#canner H! sensor defective
Harness between scanner motor and
scanner +"& board disconnected or
broken.
SC121
#canner home position error )
The scanner home position sensor
did not o &, after the scanner
moved forward $ mm and the feeler
entered the H! sensor.
#canner motor defective #canner
H! sensor disconnected- defective
SC141
.lack level detection error
Durin /01 the value for black level
was not within 2) of the prescribed
value. The copier can reproduce
monochrome- but not color.
#.3 defective Harness defective
SC142
4hite level detection error
Durin /01 the value for white level
was not within 25 of the prescribed
value.
Exposure lamp defective Harness
disconnected- damaed Dirty
exposure lass- optics #canner
motor- drive assembly defective
#.3 board defective
SC144
#.3 communication error
4hen the machine is switched on- or
when the machine returns to full
operation from the enery save mode-
the machine can not access the #.3
reister- or the #.3 reister values
are abnormal.
Dirty exposure lass or optics #.3
board defective #.3 harness
disconnected- defective
SC161
+D3 error
/fter the command is written into the
D'+D self6dianosis startup reister-
the correct value is not stored in the
reister for the prescribed lenth of
time after power on. 6or6 /fter the
neate interruption of '0/TE occurs-
+D3 is not reconized within the
prescribed time durin scannin.
+!3 board defective %defective
connection between /#+1 and D'+D-
defective L#7,1(
SC180
#canner fan lock
**$ &ne of the fan motors next to the
exposure lamp did not switch on
within *.8 sec after the 1!3 issued
the &, sinal. **) The scanner fan
motor next to the #+&. did not switch
on within *.8 sec. after the 1!3
issued the &, sinal.
'an defective 'orein ob9ect
interferin with operation of fan
:otor harness loose- disconnected-
or broken #+&. defective #.3
defective
SC195
:achine serial number error
The number reistered for the
machine serial number does not
match.
1onfirm the correct serial number of
the machine in the specifications
!olyon motor error $; &, timeout
The polyon mirror motor does not
Harness to polyon motor driver
board disconnected- defective