Você está na página 1de 4

SR NO DESCRIPTION NOS LENGTH WIDTH HEIGHT/DEPTH QTY UNIT

1
OHWT BOTTOM
B3-B4-B5-B6-B7-B8 1 6 3.15 0.2 0.7 2.65
B9 1 1 2.9 0.2 0.7 0.41
B13 1 1 2.9 0.2 0.7 0.41
1 1 1.05 0.2 0.7 0.15
3.605 CUM
2
OHWT BOTTOM
SLAB
S6 1 1 3.55 1.40 0.30 1.49
S7 1 1 3.55 2.60 0.30 2.77
S7 1 1 3.55 2.60 0.30 2.77
S8 1 1 3.55 0.65 0.30 0.69
S9 1 1 3.55 1.25 0.30 1.33
OHWT TOP
SLAB
S13 1 1 3.55 2.60 0.15 1.38
S14 1 1 3.55 2.60 0.15 1.38
S15 1 1 3.55 0.65 0.15 0.35
S16 1 1 3.55 1.25 0.15 0.67
12.83 CUM
3
RCC WALL (OHWT)
D1-BLOCK
Providing and casting in situ Ready Mix cement concrete Grade M 25 of
trap/granite/quartzite/gneiss metal for R.C.C.wall as per detailed designs and drawings or as
directed including centering, formwork, cover blocks, compaction and roughening the surface if
special finish is to be provided and curing complete. (Excluding reinforcement). (Excluding
reinforcement).(Excluding reinforcement).item includes Plastizer and Pumping of concrete to
desired Location.
Providing and casting in situ Ready Mix cement concrete Grade M25 of trap/granite/quartzite/gneiss
metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including
centering, formwork, cover blocks, compaction and roughening the surface if special finish is to be
provided and curing complete. (Excluding reinforcement).(Excluding reinforcement).item includes
Plastizer and Pumping of concrete to desired Location.
Providing and casting in situ Ready Mix cement concrete Grade M25 of trap/gran-
ite/quartzite/gneiss metal for R.C.C. slabs and landings canopy, waist slab with steps as per detailed
designs and drawings including centering, formwork, cover blocks, compacting and roughening the
surface if special finish is to be provided and curing complete. (Excluding reinforcement).item
includes Plastizer and Pumping of concrete to desired Location
1 2 3.55 0.20 3.45 4.90
1 2 7.30 0.20 3.45 10.07
1 3 3.15 0.20 3.45 6.52
21.494 CUM
4
Factor
Wall 0.120 21.49 2.58
Beam 0.150 3.61 0.54
Slab 0.125 12.83 1.60
4.724 MT
5
INTERNAL PLASTER (OHWT)
1 2 3.15 3.45 21.74
1 2 2.4 3.45 16.56
1 2 3.15 3.45 21.74
1 2 2.4 3.45 16.56
1 2 1.05 3.45 7.25
1 2 3.15 3.45 21.74
105.57 SQM
6
WATERPROFFING (TOP)
OHWT 1 1 3.55 7.3 25.92
1 -1 3.55 0.45 -1.60
24.318 SQM
7
WATERPROFFING (INTERNAL)
Providing and fixing in position TMT-FE-500 reinforcement of various diameters for R.C.C. pile caps,
footings, foundations, slabs, beams columns, canopies, staircase, newels, hajjas, lintels pardis,
copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending,
hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing and applying water proofing treatment using acrylic polymer modified cement based water
proofing coating with fibre glass mesh, mixing at the rate of powder to liquid (2:1) by weight covering
9 to 10 sqm/kg with two coat (using Dr. Fixit or alike of chemicals for masonary and concrete surface
by brush covering 7 years guarantee on Stamp Papers etc. complete.
Providing & laying water proof treatment of terrace slab with B.B. Coba in all position with an
average thickness of 112 mm consisting specialised materials as per the manufactures specifications
and covering 10 years guarantee on court fee stamp paper including all lead, lift etc. complete
Providing internal cement plaster 12 mm thick in a single coats in b) cement mortar 1:4 without
neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing complete.
over acrylic polymer modified cement based water proofing coating paid seperately
OHWT
1 2 3.15 3.45 21.74
1 2 2.4 3.45 16.56
1 2 3.15 3.45 21.74
1 2 2.4 3.45 16.56
1 2 1.05 3.45 7.25
1 2 3.15 3.45 21.74
105.57 SQM
8
EXTERNAL
OHWT 1 2 3.55 3.9 27.69
1 1 7.3 3.9 28.47
1 1 7.1 3.9 27.69
1 2 3.35 3.9 26.13
109.98 SQM
9
Fire Water Tank 1 1 3.4 3.40
Flushing Tank 1 1 3.4 3.40
Domestic Water Tank 1 1 3.4 3.40
1 1 6.7 6.70
16.900 Rmt
10
RCC WALL (OHWT) 1 2 3.55 3 21.30
1 2 7.30 3 43.80
1 3 3.15 3 28.35
93.450 Rmt
11
a) Heavy duty (225 kg) 1 3 3.00
Providing Water stops at the joints as a continuous diaphragm to contain the filler material and/or to
exclude passage of water or any other material into or out of the structure confirimng to IS 12200.
Rate shall include materials, labour, joining all complete as per drawings, specification and as
directed by the engineer. ( 300 mm wide, 10 to 25 mm thick central bubbles type)
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps
of 18mm dia mild steel bar for water tank including fixing it in (1:2:4) M-15 cement crete block 60cm
x 30cm x 30 cm & painting the ladder complete.
Providing and fixing reinforced cement concrete
cover of size 90 cm x 45 cm with frame over inspection
chamber etc. complete.
Spec. No.: As directed by Engineer in charge.
Providing and applying two coats of exterior weathershield paint of approved manufacture and of
approved colour to the plastered/concrete surfaces including cleaning, prepairing the
plaster/concrete surface, applying primer coat, scaffolding if necessary, and watering the surface for
two days complete.
Total 3.00 No