Model DS-50

DOPPLER SPEED LOG


I Complies with IMO Resolution
A.478 (XII), A.824 (19), IEC 1023
and other national regulations
I Displays ship's fore-aft and port-
starboard speeds along with
distance run and keel clearance
I Highly precise and stable
measurement by using advanced
three-beam transmission
technology
I Compact display unit for ease of
installation
I Auto mode for continuous readout
of ship's speed
I A variety of analog/digital speed
indicators are optionally available
for monitoring at a remote
location
I Signal outputs of analog/digital
speed data and distance run for
external equipment
The FURUNO DS-50 is a Doppler Speed Log
designed to meet the IMO Resolution, IEC
specifications and other national regulations. Its
three-beam transmission reduces the effect of pitch
and roll for high accuracy and enables the
measurement of port-stbd speed as well as fore-aft
speed. Keel clearance information is provided to
assist with shallow water navigation.
The DS-50 measures and displays the ship's over-
the-ground or through-the-water speed based on
the Doppler effect. Speed data can be output to
external equipment such as ARPAs, INS and IBS.
There are three operation modes: Ground-tracking,
Water-tracking and Auto. The Auto mode
continuously displays ships speed, switching
between Ground-tracking and Water-tracking
automatically.
The DS-50 consists of a display unit, processor
and transducer. The compact design of the display
unit allows flexible installation on the bridge. For
monitoring at remote locations, analog and digital
indicators are optionally available.
Catalogue No. M-1517c
R
R
TRADE MARK REGISTERED
MARCA REGISTRADA
FURUNO DEEPSEA WORLD
The future today with FURUNO's electronics technology.
FURUNO ELECTRIC CO., LTD.
9-52 Ashihara-cho, Nishinomiya City, Japan Telephone: +81 (0)798 65-2111
Telefax: +81 (0)798 65-4200, 66-4622 URL: www.furuno.co.jp
Distance indicator
DS-730
Processor unit DS-511
115/230 VAC
**
***
***
****
****
****
****
**
Processor unit
DS-510
(Transceiver built in)
or
DS-511
(Specify when ordering)
Option
Display unit
DS-500
30 m
max
30 m max Remote box
DS-501
Digital indicator
DS-350/351
Distance signal
(400 pulses/nm)
1 port
1 port
2 ports
1 port
Distance signal
(200 pulses/nm)
Keying pulse
Keying pulse
6 ports
1 port
2 ports
IEC 1162
2 ports
115/230 VAC
Shipyard supply
*TTYCY-16S
Distribution box
DS-370
Alarm signal
Alarm signal
Distance signal
(400 pulses/nm)
Digital signal (speed)
Analog signal (speed)
Range switch box
DS-389
Analog indicator
DS-381/382
20 m
4
0
0

m

m
a
x
Junction box
DS-360
Transceiver
unit DS-520
20 m
Transceiver
unit DS-520
Transducer
Junction box
CI-630
Junction box
DS-360
10/15/20/
30/100 m
*
* *
*
Transducer
20 m
1
0
0

m

m
a
x
Junction box
CI-630
20 m
Transducer DS-530
with Transducer tank
DS-531
See below for connection
between processor and transducer.
Processor unit DS-511
Connection between processor and transducer
Transducer DS-530
with Transducer tank
DS-531
(Specify either Transducer tank DS-531 or
Gate valve DS-532 when ordering)
Power
50 m max
50 m
max
50 m max
100 m
max
Processor unit DS-510 Processor unit DS-510
10/15/20/
30/100 m
**TTYCY-4S
***TTYCY-2S
****TTYCY-1S
DOPPLER SPEEDLOG DS-50
G
Clearance
m
fa
DIMMER
AL
/s
kt
ft
T
Keel istance
A
D
W
nm
84 3.3" 47 1.9"
15 0.6"
220 8.7"
3
0
0


1
1
.
8
"
212 8.3"
(140 5.5")
2
7
2


1
0
.
7
"
(
2
5
8


1
0
.
2
"
)
4-5x16
670 26.4"
(630 24.8")
600 23.6"
6
4
0


2
5
.
2
"
(
4
1
0


1
6
.
1
"
)
4- 12
6
7
8


2
6
.
7
"

3
8
1
.
5
"
2
8
4
1000 39.2"
718 28.3"
8
4
0


3
3
.
1
"
443 17.4"
400 15.7"
3
0
0


1
1
.
8
"
3
5
0


1
3
.
8
"
2- 15
216.3 8.5"
150 5.9"
25 1.0"
EQUIPMENT LIST (Specify type of processor unit when ordering)
Standard for installation with DS-510 (Transceiver unit built in)
1. Main display unit DS-500
2. Processor unit DS-510 (Transceiver built in)
3. Transducer DS-530 with 20 m cable
4. Transducer tank DS-531
5. Installation materials and spare parts
Standard for installation with DS-511 (Transceiver unit separated)
1. Main display unit DS-500
2. Processor unit DS-511
3. Transducer DS-530 with 20 m cable
4. Transducer tank DS-531 or Gate valve DS-532 (specify when ordering)
5. Transceiver unit DS-520
6.Installation materials and spare parts
Optional (Common)
1. Analog indicator DS-381/382
2. Digital indicator DS-350 (LCD display, waterproof)/351 (LED display)
3. Distance indicator DS-730
4. Distribution box DS-370
5. Range switch box DS-389
6. Junction box DS-360
7. Junction box CI-630
8. Extension cable between DS-510-CI-630/DS-520-CI-630
66S1067 (10, 15, 20, 30 or 100 m)
9. Remote box DS-501 for Main display
02045Y Printed in Japan
DISPLAY UNIT
Two-digit LED for display of port-stbd speed
Three-digit LED for display of fore-aft speed
Seven-digit LED for display of distance run/keel clearance
ULTRASONIC FREQUENCY
440 kHz
NUMBER OF BEAMS
3 beams for dual axis speed indication
MEASURING RANGE AND ACCURACY
Ship's speed
Fore-Aft: -10.0 to 40.0 knots
Port-Stbd: -9.9 to 9.9 knots
Measurable depth of ship's speed
Ground tracking: 1 to 200 m below hull bottom
Water tracking: 2 to 25 m below hull bottom
Total distance run: 0 to 99999.99 nm
Accuracy
Ship's speed: 1% or 0.1 kt, whichever is greater
Distance run: 1% or 0.1 nm, whichever is greater
Keel clearance: 1% or 0.1 m, whichever is greater
(At 1,500 m/s sound velocity)
INPUT/OUTPUT SIGNALS
Input 2 ports for external keying pulse
Output
Ship's speed 3 ports* (Digital)
1 port (Analog)
Distance signal 1 port* (400 pulses/nm)
6 ports with contact closure signal
at 200 pulses/nm
Alarm signal 1 port*
Keying pulse 1 port
Input/Output 2 ports for IEC61162 data
* For those needing more ports, Distribution box DS-370 is
optionally available
ENVIRONMENT (IEC 60945 test method)
Temperature: -15C to +55C
POWER SUPPLY
115/230 VAC
Display unit DS-500
Gate valve DS-532
(option)
Interc onnec tion Diagram
Transduc er DS-530
with tank DS-531
Proc essor unit
DS-510
Cutout for flush mount
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
SPECIFICATIONS OF DS-50
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300 Telefax: +1 360-834-9400
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K.
Phone: +44 2392-230303 Telefax: +44 2392-230101
FURUNO FRANCE S.A.
Bordeaux-Mrignac, France
Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01
FURUNO ESPANA S.A.
Madrid, Spain
Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00 Telefax: +45 36 77 45 01
FURUNO NORGE A/S
lesund, Norway
Phone: +47 70 102950 Telefax: +47 70 127021
FURUNO SVERIGE AB
Vstra Frlunda, Sweden
Phone: +46 31-7098940 Telefax: +46 31-497093
FURUNO SUOMI OY
Helsinki, Finland
Phone: +358 9 341 7570 Telefax: +358 9 341 5716

Você também pode gostar