Você está na página 1de 3

Upgrading T2000 Service Processor Firmware

From the server control module, run the 'showsc version -v' and showhost commands. Current version
numbers within 123482-02 patch.
showhost output:
System Firmware 6.2.4 Sun Fire[TM] T2000 2006/08/18 12:35
Hypervisor 1.2.3 2006/08/18 12:25
OBP 4.23.4 2006/08/04 20:46
Sun Fire[TM] T2000 POST 4.23.4 2006/08/04 21:15

showsc version -v output:
System Firmware 6.2.4 Sun Fire[TM] T2000 2006/08/18 12:35
ALOM-CMT v1.2.4 Aug 18 2006 12:31:26
VBSC 1.2.4 Aug 18 2006 12:27:38
System I upgraded:
sc> showsc version -v
Advanced Lights Out Manager CMT v1.1.6
SC Firmware version: CMT 1.1.6
SC Bootmon version: CMT 1.1.6

VBSC 1.1.5
VBSC firmware built May 9 2006, 11:28:17

SC Bootmon Build Release: 01
SC bootmon checksum: 7416BA67
SC Bootmon built May 9 2006, 11:43:18

SC Build Release: 01
SC firmware checksum: 68D5EDEB

SC firmware built May 9 2006, 11:43:31
SC firmware flashupdate JUN 15 2006, 18:47:40

SC System Memory Size: 32 MB
SC NVRAM Version = f
SC hardware type: 4

FPGA Version: 4.2.4.7
'showhost' output:
sc> showhost
Host flash versions:
Reset V1.1.5
Hypervisor 1.1.1 2006/02/24 06:38
OBP 4.20.4 2006/05/12 14:13
Sun Fire[TM] T2000 POST 4.20.2 2006/03/02 19:31
Power system off.
sc> poweroff
Are you sure you want to power off the system [y/n]? y
sc>
SC Alert: SC Request to Power Off Host.
SC Alert: Host system has shut down.
Verify that the keyswitch is in the NORMAL position.
sc> showkeyswitch
Keyswitch is in the NORMAL position.
We are ready to update the firmware, issue the 'flashupdate' command:
sc> flashupdate -s [ip address of boot server] -f /pub/Sun_System_Firmware-6_2_4-
Sun_Fire_T2000.bin
Username: ftp
Password: *****

SC Alert: System poweron is disabled.

Update complete. Reset device to use new software.

SC Alert: SC firmware was reloaded
firmware now updated, reset SC:
sc> resetsc
Are you sure you want to reset the SC [y/n]? y
User Requested SC Shutdown
After reset, showhost and showsc version -v now show:
sc> showhost
System Firmware 6.2.4 Sun Fire[TM] T2000 2006/08/18 12:35

Host flash versions:
Hypervisor 1.2.3 2006/08/18 12:25
OBP 4.23.4 2006/08/04 20:46
Sun Fire[TM] T2000 POST 4.23.4 2006/08/04 21:15
sc> showsc version -v
Advanced Lights Out Manager CMT v1.2.4
SC Firmware version: CMT 1.2.4
SC Bootmon version: CMT 1.2.4

VBSC 1.2.4
VBSC firmware built Aug 18 2006, 12:27:38

SC Bootmon Build Release: 00
SC bootmon checksum: EF3B7ADD
SC Bootmon built Aug 18 2006, 12:34:48

SC Build Release: 00
SC firmware checksum: 2B377B21

SC firmware built Aug 18 2006, 12:35:01
SC firmware flashupdate SAT SEP 23 00:02:06 2006

SC System Memory Size: 32 MB
SC NVRAM Version = 10
SC hardware type: 4

FPGA Version: 4.2.4.7
setupsc now does this:
sc> setupsc
Entering Interactive setup mode. To exit and discard changes to that point, use
Ctrl-C or to exit and save changes to that point, use Ctrl-Z.
Do you wish to configure the enabled interfaces [y]? y
Should the SC network interface be enabled [y]? y
Should the SC interface connection type be set [ssh]? ssh
Should the SC email alerts be enabled [y]? n
Do you wish to configure the network interface [y]? y
Should the SC use DHCP to obtain its network configuration [y]? n
Enter the SC IP address [100.100.100.100]? 130.207.166.31
Enter the SC IP netmask [255.255.255.0]? 255.255.255.0
Enter the SC IP gateway address [100.100.100.100]? 130.207.166.1
Do you wish to configure the network management interfaces [y]? y
Enter the number of mail servers to configure [0]? 0
Do you wish to configure the SC parameters [y]? y
Enter any customer data for this platform (maximum of 40 characters) []?
Enter the console session escape sequence (2 characters). The first character can be
any printable characters or control-A
through control-Y except for control-C, control-D, control-H, control-J, or control-M.
The second character must be a
".".[#.]? #.
Enter level of events to be displayed over the CLI where valid settings are 0 (none),
1 (critical), 2 (critical and major)
and 3 (critical, major and minor) [2]? 2
Should powerstate memory be enabled [y]? y
Should poweron sequencing be enabled [y]? y
Enter the SC cli prompt (maximum of 16 characters) [sc]? sc
Enter the SC CLI timeout in seconds (maximum of 10000s) [0]? 0
Should password entry echo '*'s [y]? y
Do you wish to configure the platform diagnostic parameters [y]? y
Enter the type of reset which will initiate system diagnostic [power-on-reset error-
reset]? power-on-reset error-reset
Enter the verbosity level of diagnostic output [normal]? normal
Enter the test coverage level of the system diagnostic [max]? max
Enter the automatic system diagnostic mode [normal]? normal
Should the host continue to boot after error is encountered [n]? n
Your ALOM configuration profile has been successfully completed. To activate your
network configuration, please reset the