Wb All dimensions are in centimeters unless otherwise
specified. # 3 Hor.Temp Bars All concrete shall be 3,000 psi. (fc') except where Sp. @ 30cm. O.c. otherwise specified. Wa Concrete cover for steel shall be 7.5 cms.for footing and 4 cms. For vertical wall. Filter Drain All exposed edges of the concrete shall be rounded or Hb chamfered. 2"Ø Weepholes Hc Ha Lapping of bars shall be 24D for deformed bars and 48D for plain bars. H All main reinforcements shall be contineud to the footing. #3 Vert. temp Bars Hb B/2 SPECIAL NOTES: Sp. @ 30cm. o.c. B This retaining wall is designed for level earth with G Ha Bar "F" (Every other one (1) foot surcharge. For a greater surcharge a special Bar cut at B/2) design will be required. F For Heights 2.50 m. & Below Assumed angle of internal friction of soil, Ø = 33°-40° Wc Weight of earth backfill = 100 pcf D Wb Coefficient of Sliding Friction is 0.30 R Wa WORKING STRESSES: B/2 for bar "A" fs = 18,000 psi fc = 1,200 psi fc' = 3,000 psi v= 60 psi E A B Hc Hb n= 10 u= 200 psi Ha Provide Shear Key when Retaining Wall is independent
STANDARD L - SHAPED RETAINING WALL B/2
FOR DRY BACKFILL B For Heights 3.00 m. & Above
DIMENSIONS Wa Wb Wc Bar F HT. OF #3 Spa.of # 3 Max.