Você está na página 1de 8

FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS

Mics KERYS
KER/GB-2004/1
Mechanical
Generator alone or plant
HV or LV operation
Normal/Backup operation
Fugitive or permanent cut-free
network coupling operation :
- on network return,
- on peak limiting,
- during tests.
Inverted backup operation
Power production plant
Cogeneration
Building on the experience acquired with the MICS Process I and II, of which over 10,000 units have been installed worldwide, SDMO has designed
the Mics KERYS. This innovative, user-friendly and intuitive monitoring-control system offers a broad range of features. It is fitted as standard on all generator
units designed for coupling applications and can be optionally fitted on all our other applications. The Mics KERYS can be directly integrated onto the generator,
or provided in a separate cabinet, in order to meet all low or medium voltage power plant constraints.
- Speed,
- Alarms,
- Motor safety devices,
- Specific customer
requirements.
- Currents,
- Voltages,
- Powers,
- Frequency,
- Microbus.
Mechanical
Electrical
Mechanical
Electrical
- Speed,
- Synchronisation,
- Coupling,
- Generator or network
active power distribution
or lock-out,
- Wattmetric programming.
- Voltage,
- Voltage equalisation,
- Generator or network
reactive power distribution
or lock-out,
- Generator or network power
factor regulation (cos Phi).
Other physical quantities... Monitoring-control cabinet
2 x 2000 KVA
Mics KERYS touch screen
console on 2000 kVA generator set
Electrical - Voltages,
- Currents,
- Frequency and energies,
- Power factors,
- Powers,
- Mechanical and
electrical metering.
- Temperatures,
- Pressures and levels
according to motor configuration.
On-board Web site
User-friendly man/machine interface
5 resident languages (French, English,
Spanish, Portuguese, German) of which
one interchangeable
(contact us for details)
Ethernet port
Dialogue with all motors fitted
with on-board electronics (ECU)
Mod Bus RTU port
RS232 port
FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS
Automatic generator control Measurements and displays Communication
Protective devices Controls
Control screen Synchro screen Graph display
MI CS KERYS
2
3
MI CS KERYS
Functions keypad
Display screen
TFT LCD screen 16/9me
Colour graphical display
Touch screen
Dimensions 154 x 86 mm
with display LED
Control keypad
Move up
Move down
Move right
Validate/output
Move left
Oil pressure fault
Fault summary
Alarm summary
Water temperature fault
Battery voltage fault
Display screen
Alarm and fault LEDs
LCD standard
Monochrome graphical display
Dimensions 114 x 64 mm
Man mode selection
Stop mode selection
Auto mode selection
Close GE circuit breaker
Open network circuit breaker
Activate test (no load or on-load)
Deactivate test
Stop horn
LED test
Erase anomalies
Open GE circuit breaker
Close network circuit breaker
Control keypad
with display LED
Configuration keypad
For configuration, navigation
and direct access to screens
Elements common to both MMIs
Specific elements
The Mics KERYS is available with two different Man-Machine Interfaces (MMIs): the standard version possesses a monochromatic screen with LEDs
and function keyboard, the top of the range version possesses a colour touch screen.
FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL SUPERVISION COMMUNICATION PRODUCT PLUS POINTS
CURRENT
INSULATION CONTROL
UNCOUPLING / MICROCUTS
VOLTAGE
FREQUENCY
ACTIVE AND REACTIVE POWER
Overload (50) - Short circuit (50/51) - Phase current direction indicator (67) - Neutral current (four-pole) (50)
Inverse component (50) - Voltage carry over (51V) - Thermal image (49)
Voltage minimum (27) - Voltage maximum (59) - Presence and absence of voltage (27)
Frequency minimum (81) - Frequency maximum (81)
Active power maximum (32) - Active power return (32P) - Reactive power return (40)
Loss of excitation (40)
Homopolar current (51N) - Homopolar current direction indicator (67N)
Homopolar voltage (64) - Restricted earth (64 REF)
Vector jump (78) - Impedance minimum (21) - Frequency variation dF/dt (78)
MI CS KERYS
Binary input/output modules
Analogue input modules
Analogue output modules
Temperature input modules
Base module
- Automatic
controls
- Configuration
- Communication
- Logical and analogue I/O
External connexions
Series 232/485
Ethernet
Kerys
or
Man/Machine interface
Kerys tactil
Protection and
measurements module
Control and
measurements module
Use of the measurement and protection modules and of the measurement and control modules according
to application configuration.
* All protection systems are available within the measurement and protection modules,
only some of these systems are available in the measurement and control modules (contact us for details).
Mics Kerys modularity
Protections available* (ANSI codes)
FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS
4
Main applications
Single generating set
Generator sets plant
Fugitive or permanent network coupling
Power production plant (up to 15 generator sets)
Cogeneration
Possibility of successive coupling to 5 networks
Manual or automatic synchronisation
phasing
frequency equalisation
voltage equalisation
Control
Measurements and display
global and phase-based
active power
global and phase-based
reactive power
global and phase-based
power factor
Synchro measurements
phase deviation
voltage deviation
frequency deviation
Other
active energy coupling
reactive energy metering
U and I harmonics
mains loss detection
generator set and network
rotational field control
Operation
measurements analysis with log plots and data archiving, used for diagnostic and maintenance assistance
MI CS KERYS
Dual frequency
Multi-voltage
Voltage setpoint adjustment
Frequency setpoint adjustment
. setting a setpoint value
. manual value adjustment
. multi-voltage
. setting a setpoint value
. manual value adjustment
. dual frequency
Speed control with all motor types
Voltage control with all AC generator types
Voltage
Speed/Frequency
. setting a setpoint value
. manual power adjustment
. manual or automatic distribution
. power build-up ramp
and load sheeding ramp
(value and time)
Active and reactive power
FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS
5
EXAMPLE OF COMMUNICATION REPRESENTATION
WITH REMOTE MAINTENANCE AND SUPERVISION
MI CS KERYS
ETHERNET NETWORK ETHERNET NETWORK
RTC
RS 485 RS 485
Bus
CAN
Bus
CAN
Bus
CAN
Example applications
MMI PLANT MMI GENERATOR 1 MMI GENERATOR 2
ROUTER MODEM
LOCAL PC
REMOTE PC MODEM
Plant base module
GENERATOR 1
Plant base
module
SWITCH / HUB
GENERATOR 1 GENERATOR 2
Measurements and
control module
Measurements and
protection module
Measurements and
protection module
Measurements and
protection module
Measurements and
control module
Measurements and
control module
FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS
Plant base module
GENERATOR 2
PRINTER
6
CAN BUS LINK
The CAN (Controller Area Network) bus, broadly used in the motor and general industry, is a tried and tested
technology, providing a high degree of electromagnetic immunity and simplified implementation, connected by simple
shielded pair. There are numerous protocols, they are of the proprietary type, or comply with a specific standard.
The KERYS Mics use 3 types of protocol: a protocol for system-internal operation, the CAN OPEN protocol
and the J1939 CAN protocol.
ETHERNET LINK
Ethernet is a high speed local network capable of connecting a great number of systems of different types.
The KERYS and KERYS Tactil Mics use this type of link for connecting the base module to the MMI as it allows :
rapid transmission of user data, entered with the keypad, to the base module
information requested by the user to be displayed on-screen
We can then create a network of systems connected by wire double pairs via a computer HUB or switch,
thus allowing simple RJ45 type connections.
WEB site
The KERYS and KERYS Tactil Mics are delivered as standard with a particularly user-friendly On-board web site.
This feature presents a number of advantages. Indeed, it is possible, by launching Internet Explorer on your PC
and connecting to the base modules IP address, to obtain all of the information concerning the operation
of your equipment via the local Ethernet network (Intranet), or from the WEB via a remote modem (Internet).
Connection to the base module through the sites various pages, allows you to :
view, in real time, the electrical or mechanical values
modify the configuration via a customised access code
control the generator set or plant, on condition that certain security conditions are met

Over 60 display screens are available in each of the resident languages.
Whatever the distance separating you from your installation, SDMO rapidly gives you the answer that you expert.
Internal and externat communication
MI CS KERYS
Electrical measurements Network or bus bar measurements Mechanical measurements
Harmonics display Central unit measurement summary Alarms and faults
FEATURE MAN-MACHINE INTERFACE MODULARITY / PROTECTION MEASUREMENTS / CONTROL ARCHITECTURE COMMUNICATION PRODUCT PLUS POINTS
7
SUBSIDIARIES
MICS KERYS: PRODUCT PLUS POINTS
PLC dedicated to generator set applications
Choice of multiple resident standard configurations
Addition of auxiliary logic without the need to use an external tool
Functional module library
Troubleshooting
Validation of protections by simulation
Variable status display
Troubleshooting guide with keyword search
Assistance and Maintenance
Automatic Email transmission on triggering of alarms or faults,
or on maintenance operation requests
Log of actions performed (maintenance or repairs)
Load impact
Improved generator performance on strong load
Plotting and logging of electrical and mechanical parameters
Adjustable sampling and definable criterions for release
Compliance with international standards
The Kerys and Kerys tactil MICS as a whole, have been thoroughly tested
by independent laboratories (climatic tests, electromagnetic counting,
vibratory tests, etc.).
They are EC, UL and CSA certified.
SDMO Industries - 12 bis rue de la Villeneuve - CS 92848 - 29228 Brest Cedex 2 - France
Tl. +33 (0)2 98 41 41 41 - Fax. +33 (0)2 98 41 63 07 - Telex 615 092F - www.sdmo.com
S.A.S au capital de 17 066 520
0
4
-
2
0
0
4

G
B

K
E
R
Y
S
/
0
1


S
D
M
O


R
C
S

B
r
e
s
t

5
4
8

2
0
2

9
8
5

-
























-

P
h
o
t
o
s

:

G
e
t
t
y

I
m
a
g
e
s
/
P
h
o
t
o
g
r
a
p
h
e
r

s

C
h
o
i
c
e

-

B
r
e
n
d
a
n

B
e
i
r
n
e
/
S
t
u
d
i
o

2
9
P
r
i
n
t
e
r

:

C
a
l
l
i
g
r
a
p
h
y

-

A
l
l

i
n

o
r
d
e
r

t
o

i
m
p
r
o
v
e

s
t
i
l
l

f
u
r
t
h
e
r

t
h
e

q
u
a
l
i
t
y

o
f

i
t
s

p
r
o
d
u
c
t
s
,

S
D
M
O

I
n
d
u
s
t
r
i
e
s

r
e
s
e
r
v
e
s

t
h
e

r
i
g
h
t

t
o

m
o
d
i
f
y

a
n
y

o
f

t
h
e

s
p
e
c
i
f
i
c
a
t
i
o
n
s

i
n
d
i
c
a
t
e
d

i
n

t
h
i
s

c
a
t
a
l
o
g
u
e

w
i
t
h
o
u
t

n
o
t
i
c
e
.

N
o
n

c
o
n
t
r
a
c
t
u
a
l

d
o
c
u
m
e
n
t
.

C
o
p
y
r
i
g
h
t

S
D
M
O


-

D
o
n

t

t
h
r
o
w

o
n

t
h
e

p
u
b
l
i
c

h
i
g
h
w
a
y
SDMO ENERGY Ltd
United Kingdom
Tel. +44 (0) 1932 345 777
Fax +44 (0) 1932 350 033
SDMO INDUSTRIES IBERICA
Spain
Tel. +34 93 586 34 00
Fax +34 93 580 31 36
SDMO NV/SA
Belgium
Tel. +32 3 646 04 15
Fax +32 3 646 06 25
SDMO GENERATING SETS Inc
USA
Tel. +1 305 863 00 12
Fax +1 305 863 97 81
SDMO DO BRASIL Ltda
Brazil
Tel. +55 (11) 4053-2700
Fax +55 (11) 4053-2718
SDMO ARGENTINA
Argentina
Tel./Fax +54 114 205 3005
SDMO ASIA PACIFIC PTE Ltd
Singapore
Tel. +65 6419 3788
Fax +65 6419 3798
BUREAU
SDMO Algiers
Algeria
Tel. +213 21 92 55 84
Fax +213 21 92 47 76
ISO 9001
SDMO Industries
Sites in France

Você também pode gostar