PDL Elimit is specifically designed to minimise the risk
of a fatal electric shock when working with electricity
around the home or on the building site. It is an
electronic sensing device which constantly monitors the
balance of current flow to ensure that, should even a
minute leakage occur, the PDL Elimit will switch off the
power in less than the time of a single heartbeat. That
could mean the difference between life and death.
The PDL Elimit can save your life!
The body is normally driven by minute electrical signals
which control muscles and heart. If an electrical current from
the mains passes through the body, normal body function
will be disrupted. The effect of this disruption, called
ventricular fibrillation, depends on the severity of the shock
and the length of time the person is subjected to it.
The PDL Elimit provides protection by switching the current
off immediately. When electrical leakage to earth exceeds as
little as 10mA (10 thousandths of one Amp) or 30mA
(30 thousandths of one Amp), the PDL Elimit will switch off
the current within 30 milliseconds (30 thousandths of a
second). Thats less than the time it takes for a single
heartbeat, and could mean the difference between life and
death. PDLs commitment to research and development has
ensured that Elimit has been engineered to meet the latest
international standards in RCD technology.
In the workshop and outdoors, many factors, such as
dampness, faulty wiring, frayed cords and other hazards, can
contribute to a potentially lethal situation when using power
tools and extension leads, electric barbeques, electric
lawnmowers, temporary party lighting, pool vacuums, filters,
spas, pool lights and any other outdoor electrical equipment.
PDL Elimit offers personal protection against electrocution
from live to earth faults.
Theres no doubt that, from time to time, we are all
subconsciously careless around electricity. PDL Elimit is an
insurance against this. However, it must be pointed out that
RCD devices do not protect against all causes of electric
shock such as those caused by contracting both Live and
Neutral of the electrical circuit its use should not be taken
as a substitute for safe electrical practices or for electrical
maintenance.
PDL ELIMIT
3
When properly connected, an electrical current flows through the
live wire (fig.1) on its way to the appliance and returns via the
neutral wire (fig.2).
If, for some reason, the current leaks (through dampness, frayed
wire, faulty connection etc.), it will take the most direct path to earth
often through a persons body. If that power is not cut off instantly,
there is a strong possibility that person will die.
The path taken by the current also contributes to the shocks
severity. A shock which flows from the hand through the arms and
chest will affect both breathing and heartbeat.
The time that a person is exposed to the shock is the greatest factor
in the severity of the accident. A PDL Powerguard cuts off the power
in 30 thousandths of a second thats less than the time of a
single heartbeat!
A leakage as little as 10mA (10 thousandths of one Amp) or 30mA
(30 thousandths of one Amp) is sufficient to trip the PDL Powerguard
and cut off the power to the appliance thats a minute amount of
current when you consider that many appliances use as much as
10 Amps.
4
3
2
1
1
2
How the PDL Powerguard Works
3
4
55
NEW ZEALAND / AUSTRALIAN PRODUCT
Pages 6 - 13
BRITISH STANDARD PRODUCT
Pages 14 - 17
EUROPEAN PRODUCT
Pages 18 - 19
NORTH AMERICAN PRODUCT
Page 20
OEM PRODUCT
Page 21
INDEX
6
NEW ZEALAND/AUSTRALIAN PRODUCT
ADAPTOR
Cat 951
Plug-in RCD Adaptor, 10A
The PDL Powerguard plug-in RCD adaptor is ideal for providing an earth-fault
protected power source indoors. It is available in white or orange.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP3X
Type Tested to: AS3190:1997
AS3100:1994
T E C H N I C A L S P E C I F I C A T I O N S
REWIRABLE PLUG
Cat 952
Rewirable RCD Plug, 10A
The PDL Powerguard RCD rewirable plug can be attached to any appliance,
flexible cord or socket to accommodate the specific earth-fault protection
needs of the user. Cat 952 is as easy to wire as any conventional plug. It is
available in white or orange.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP3X
Type Tested to: AS3190:1997
AS3100:1994
T E C H N I C A L S P E C I F I C A T I O N S
7
Cat 955 - 2M
Cat 955 - 10M
Cat 955 - 25M
RCD Cordset, 10A
The PDL Powerguard RCD cordset features a 2, 10 or 25m cord enabling it to
provide earth-fault protection over longer distances making it the safer
alternative to an ordinary extension cord.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP33
Cord Length: 2m, 10m, 25m
Type Tested to: AS3190:1997
AS3100:1994
Cat 957 - 2M
RCD Extension Cord, 10A
Combined with a 2 metre flexible cord, the PDL Powerguard RCD plug can
provide earth-fault protection to activities away from the socket outlet. A long
cord is one of the most potentially dangerous accessories around the home -
an RCD protected flexible cord is the safe solution.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP33
Cord Length: 2m
Type Tested to: AS3190:1997
AS3100:1994
Cat 956
RCD Cordset, 10A, IP56
Cat 956 combines IP56 environment protection with earth-fault protection
making it ideal for use in situations where dust and water pose a potential
hazard.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP56
Cord Length: 2m
Type Tested to: AS3190:1997
AS3100:1994
IEC529:1989
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
CORDSETS
NEW ZEALAND/AUSTRALIAN PRODUCT
8
Cat 954
RCD Protected Cordset, 10A, IP44
Cat 954 provides an earth-fault protected source of electricity for tents and
caravans in camping parks. It features a BS4343 plug attached to an RCD
protected AS3112 10A socket outlet by a 10m extension cord.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP56 RCD enclosure and socket, IP44 - plug
Cord Length: 10m
Type Tested to: AS3190:1997
AS/NZS3112:1993
BS4343:1968 (Plug Specification)
Cat 024RCD
RCD Protected 4-Gang Powerboard
Providing earth-fault protection to a 4-gang powerboard, the PDL
Powerguard RCD is ideal for when a number of appliances are to be used
simultaneously in potentially hazardous situations. The powerboard is
provided with 10A over-current protection to prevent the wiring circuit being
damaged by drawing too much current. The RCD is connected to the
powerboard by a 1m flexible cord.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Type Tested to: AS3190:1997
AS3100:1994
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
CORDSETS (cont.)
POWERBOARD
NEW ZEALAND/AUSTRALIAN PRODUCT
9
SAFETY SWITCHES
NEW ZEALAND/AUSTRALIAN PRODUCT
Cat 596RCD
Vertical/Horizontal Flush Plate Mounted RCD
The PDL Powerguard RCD is available as a 20A mounted plate version to
provide downstream protection to a number of socket outlets or permanently
wired appliances on the same circuit. The unit features double-pole
switching to protect the appliance user against an earth fault even in the
situation where Active and Neutral have been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 20A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 84mm
Type Tested to: AS3190:1997
AS3100:1994
Cat 696RCD
Vertical/Horizontal Flush Plate Mounted RCD
The PDL Powerguard RCD is available as a 20A mounted plate version to
protect a number of socket outlets or permanently wired appliances on the
same circuit. The unit features double-pole switching to protect the appliance
user against an earth fault even in the situation where Active and Neutral have
been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 20A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 84mm
Type Tested to: AS3190:1997
AS3100:1994
Cat 596/56RCD
Vertical/Horizontal Flush Plate Mounted RCD, IP56
The PDL Powerguard RCD is available mounted in an IP56 flush plate to
provide the device with environmental protection for use in damp or dusty
conditions. The unit features double-pole switching to protect the appliance
user against an earth fault even in the situation where Active and Neutral have
been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 20A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP56
Mounting Centres: 84mm
Type Tested to: AS3190:1997
AS3100:1994
T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
10
Cat 591FRCD 10mA or 30mA, 10A Outlet, 20A RCD
Protected Circuit
RCD Protected Single Vertical Socket Outlet
The PDL Powerguard RCD combined with a single socket outlet provides an
earth-fault protected power source and can be wired to provide protection to
other socket outlets downstream on the same circuit. The 591FRCD - 10mA
has a rated tripping current of 10mA for more sensitive earth-fault protection,
making it suitable for medical applications.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A Socket Outlet, 20A - Protected Circuit
Rated Tripping Current: 10mA or 30mA versions available
Average Tripping Time: 30ms
Mounting Centres: 84mm
Type Tested to: AS3190:1997
AS/NZS3112:1993
Cat 691BRCD - 10mA or 30mA, 10A Outlet, 20A RCD
Protected Circuit
RCD Protected Single Vertical Socket Outlet
The PDL Powerguard RCD combined with a single socket outlet provides an
earth-fault protected power source and can be wired to provide protection to
other socket outlets downstream on the same circuit. The 691BRCD - 10mA
has a rated tripping current of 10mA for more sensitive earth-fault protection,
making it suitable for medical applications. Contacts remain closed in the
event of loss of supply voltage, ensuring immediate protection when the
supply is resumed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A - Socket Outlet, 20A - Protected Circuit
Rated Tripping Current: 10mA or 30mA versions available
Average Tripping Time: 30ms
Mounting Centres: 84mm
Type Tested to: AS3190:1997
AS/NZS3112:1993
Cat 694BRCD - 10mA or 30mA, 10A Outlet, 20A RCD
Protected Circuit
RCD Protected Single Horizontal Socket Outlet
The PDL Powerguard RCD combined with a single socket outlet provides an
earth-fault protected power source and can be wired to provide protection to
other socket outlets downstream on the same circuit. The 694BRCD - 10mA
has a rated tripping current of 10mA for more sensitive earth-fault protection,
making it suitable for medical applications. Contacts remain closed in the
event of loss of supply voltage, ensuring immediate protection when the
supply is resumed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A - Socket Outlet, 20A - Protected Circuit
Rated Tripping Current: 10mA or 30mA versions available
Average Tripping Time: 30ms
Mounting Centres: 84mm
Type Tested to: AS3190:1997
AS/NZ3112:1993
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
NEW ZEALAND/AUSTRALIAN PRODUCT
SOCKET OUTLETS
T E C H N I C A L S P E C I F I C A T I O N S
11
Cat 575LRCD
Shaver Socket/RCD Protected Socket Outlet
The PDL Powerguard RCD socket outlet is available combined with a
universal shaver socket in a vertical configuration to provide an earth-fault
protected power source in damp areas such as bathrooms. Cat 575LRCD
suits the Cat 575MB wall box. Can be wired to provide protection to other
socket outlets downstream on the same circuit.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A Socket Outlet, 20A Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 145mm
Type Tested to: AS3190:1997
AS3194:1993
Cat 675HRCD
Shaver Socket/RCD Protected Socket Outlet
The PDL Powerguard RCD socket outlet is available combined with a
universal shaver socket in a horizontal configuration to provide an earth-fault
protected power source in damp areas such as bathrooms. Can be wired to
provide protection to other socket outlets downstream on the same circuit.
The unit comes with a wall box.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A Socket Outlet, 20A Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 145mm
Type Tested to: AS3190:1997
AS3194:1993
T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S
SOCKET OUTLETS (cont.)
NEW ZEALAND/AUSTRALIAN PRODUCT
12
Cat 56C320RCD
RCD Protected Socket Outlet, 20A, IP66
Cat 56C320RCD provides IP66 environmental and earth-fault protection for
the 3-pin 20A AS3123 socket outlet. It is suitable for use in Australia and New
Zealand in conditions where dust and water pose a potential hazard and
features double-pole switching to protect the appliance user against an earth-
fault even in the situation where Active and Neutral have been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 20A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66
Dimensions: 200 x 100 x 75mm
Type Tested to: AS3190:1994
IEC529:1989
AS3123:1987
T E C H N I C A L S P E C I F I C A T I O N S
Cat 56C310RCD
RCD Protected Socket Outlet, 10A, IP66
Cat 56C310RCD provides IP66 environmental and earth-fault protection for
the 3-pin 10A AS3112 socket outlet. It is suitable for use in Australia and New
Zealand in conditions where dust and water pose a potential hazard and
features double-pole switching to protect the appliance user against an earth-
fault even in the situation where Active and Neutral have been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 10A - Socket Outlet, 20A - RCD Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66
Dimensions: 200 x 100 x 75mm
Type Tested to: AS3190:1994
IEC529:1989
AS/NZS3112 : 1993
Cat 56RCD20
56 Series Plate, 20A, IP66
The PDL Powerguard RCD is available mounted in a 56 Series IP66 one gang
enclosure giving earth-fault protection to other socket outlets wired
downstream on the same circuit. The unit features a double-pole switch to
protect the appliance user against an earth fault even in the situation where
Active and Neutral have been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 20A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66
Dimensions: 100 x 100 x 75mm
Type Tested to: AS3190:1994
AS3100:1994
IEC529:1989
Cat 56C316RCD
RCD Protected Socket Outlet, 16A, IP66
Cat 56C316RCD provides IP66 environmental protection and earth-fault
protection for the 3-pin IEC309 socket outlet. It features double-pole
switching to protect the appliance user against an earth-fault even in the
situation where Active and Neutral have been reversed.
Rated Voltage: 250V a.c., 50Hz
Rated Current: 16A - Socket Outlet, 20A - RCD Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66 when flaps are closed, IP44 with plug fitted
Dimensions: 200 x 100 x 75mm
Type Tested to: AS3190:1994
IEC309:1988
IEC529:1989
T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
NEW ZEALAND/AUSTRALIAN PRODUCT
IP66 INDUSTRIAL SWITCHGEAR
13
NEW ZEALAND/AUSTRALIAN PRODUCT
14
REWIRABLE PLUG ADAPTOR
Cat 952B
Rewirable RCD Plug, 13A
The PDL Elimit rewirable RCD plug, in BS format, can be wired to any
appliance, cord or trailing socket to provide earth-fault protection. The unit is
as easy to wire as a standard plug and is provided with a 13A fuse to give
over-current protection. The Cat 952B is ideal for situations where a specific
appliance needs to be protected.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP3X
Type Tested to: BS7071:1992
BS1363:1984
Cat 1951
Plug-in RCD Adaptor, 13A
The PDL Elimit RCD adaptor is suitable for use with most portable electrical
tools and appliances providing earth-fault protection from the socket outlet.
It features double-pole switching, ie both Live and Neutral are independently
switched, to protect against faulty wiring. The RCD trips out automatically on
the loss of power.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP3X
Type Tested to: BS7071:1992
BS1363:1984
T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S
BRITISH STANDARD PRODUCT
Cat 955B
RCD Cordset, 13A
The PDL Elimit RCD cordset is the safer alternative to a normal extension
cord, providing earth-fault protection to most portable electrical tools and
appliances. The IP33 environment protection makes it ideal for use in
garages and other areas where electrocution is a hazard.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP33
Cord Length: 2m
Type Tested to: BS7071:1992
BS1363:1984
T E C H N I C A L S P E C I F I C A T I O N S
CORDSET
15
SAFETY SWITCHES
Cat 1796RCD
Flush Plate Surface Mounted RCD, 13A (2-Gang Plate)
Type A detects loss of supply or neutral.
Type B contacts remain closed in the event of loss of supply voltage.
PDLs 1700 Series range of high-impact surface accessories offers an Elimit
flush plate mounted RCD for spur connection of a socket or fixed appliance
off the ring main. The unit features double-pole switching to protect the
appliance user against an earth-fault even in the situation where Live and
Neutral have been reversed. The 1796RCD is available with a plastic or a
metal mounting box.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 120mm
Type Tested to: BS4293:1983
Cat 1596RCD
Flush Plate Mounted RCD, 13A (2-Gang Plate)
Type A detects loss of supply or neutral.
Type B contacts remain closed in the event of loss of supply voltage.
The PDL Elimit flush plate mounted RCD is designed for spur connection of a
socket or fixed appliance off the ring main. The unit features double-pole
switching to protect the appliance user against an earth-fault even in the
situation where Live and Neutral have been reversed.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 120mm
Type Tested to: BS4293:1983
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
BRITISH STANDARD PRODUCT
POWERBOARDS
Cat 070RCD
RCD Protected 4-Gang Trailing Socket, 13A
The PDL Elimit rewireable RCD plug is available attached to a 4-gang trailing
socket to provide earth-fault protection to a number of appliances. It is
ideally suited to applications where a number of tools or appliances are to be
operated at the same time. The trailing socket is fitted with a patented quick-
release wall-mounted bracket.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Rated Tripping Time: 30ms
Environmental Protection: IP3X - plug only
Cord Length: 1m
Type Tested to: BS7071:1992
BS1363:1984
Cat 071RCD
RCD Protected 4-Gang Switched Trailing Socket, 13A
The PDL Elimit rewirable RCD plug is also available attached to a 4-gang
switched trailing socket to provide earth-fault protection to a number of
appliances. The trailing socket is fitted with a switch providing convenient
control of the supply of electricity to appliances connected to it. A neon fitted
to the trailing socket shows whether power is being supplied.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Rated Tripping Time: 30ms
Environmental Protection: IP3X - plug only
Cord Length: 1m
Type Tested to: BS7071:1992
BS1363:1984
T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S
16
Cat 1561RCD
RCD Protected Single Socket Outlet, 13A (2-Gang Plate)
Type A detects loss of supply or neutral.
Type B contacts remain closed in the event of loss of supply voltage.
The PDL Elimit RCD one-gang BS socket outlet features double pole
switching to protect the appliance user against earth faults even in the
situation where Live and Neutral have been reversed.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 120mm
Type Tested to: BS7288:1990
BS1363:1984
Cat 1761RCD
RCD Protected Surface Mounted Single Socket Outlet, 13A (2-Gang Plate)
Type A detects loss of supply or neutral.
Type B contacts remain closed in the event of loss of supply voltage.
The PDL Elimit RCD one-gang BS socket outlet features double pole
switching to protect the appliance user against earth faults even in the
situation where Live and Neutral have been reversed. The unit is available
with a plastic or metal mounting box.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 120mm
Type Tested to: BS7288:1990
BS1363:1984
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
SOCKET OUTLETS
BRITISH STANDARD PRODUCT
17
BRITISH STANDARD PRODUCT
IP66 INDUSTRIAL SWITCHGEAR
Cat 1562RCD
RCD Protected Double Socket Outlet, 13A
Type A detects loss of supply or neutral.
Type B contacts remain closed in the event of loss of supply voltage.
The PDL Elimit RCD two-gang BS socket outlet features double pole
switching to protect the appliance user against earth faults even in the
situation where Live and Neutral have been reversed.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 120mm
Type Tested to: BS7288:1990
BS1363:1984
Cat 1762RCD
RCD Protected Surface Mounted Double Socket Outlet, 13A
Type A detects loss of supply or neutral.
Type B contacts remain closed in the event of loss of supply voltage.
The PDL Elimit RCD two-gang BS socket outlet features double pole
switching to protect the appliance user against earth faults even in the
situation where Live and Neutral have been reversed. The unit is available
with a plastic or metal mounting box.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Mounting Centres: 120mm
Type Tested to: BS7288:1990
BS1363:1984
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
56C313RCD
RCD Protected Socket Outlet, 13A, IP66
Cat 56C313RCD provides IP66 environmental and earth-fault protection for
the 3-pin 13A BS1363 socket outlet. It is suitable for use in conditions where
dust and water pose a potential hazard and features double-pole switching to
protect the appliance user against an earth-fault even in the situation where
Active and Neutral have been reversed.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 13A - Socket Outlet, 20A - RCD Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66
Dimensions: 200 x 100 x 75mm
Type Tested to: AS3190:1994
IEC529:1989
BS1363:1984
T E C H N I C A L S P E C I F I C A T I O N S
SOCKET OUTLETS (cont.)
18
EUROPEAN PRODUCT
ADAPTORS
REWIRABLE PLUG
Cat 951S
Plug-in RCD Adaptor, 16A (Side-Earthing Contacts)
The PDL Elimit plug-in RCD adaptor is available with side-earthing contacts and
is ideal for providing an earth-fault protected power source indoors. It is
suitable for use with most portable electrical tools and appliances providing
earth-fault protection at the socket outlet.
Rated Voltage: 250V a.c., 50Hz
Rated Current: 16A
Environmental Protection: IP3X
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Type Tested to: Certified to para 5.2 EMVG respectively Art 10.2 of the EMC
Council Directive EN55104: 1995, Category II.
Tested to EN61008-1:1994 & A2 & A11, EN61008-2-1/08.94,
IEC 884-1/06.94 & IEC 884-1/A1/12.94.
Complies with draft standard 23E/263/FDIS for portable RCD
products. Complies with low voltage directive 73/23/EEC and
93/68/EEC.
Cat 951F
Plug-in RCD Adaptor, 16A (Pin-Type Earth Contact)
The PDL Elimit plug-in RCD adaptor is available in the pin-type earth contact
format, predominantly used in France. It is suitable for use with most portable
electrical tools and appliances providing earth-fault protection at the socket
outlet.
Rated Voltage: 250V a.c., 50Hz
Rated Current: 16A
Environmental Protection: IP3X
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Type Tested to: Certified to para 5.2 EMVG respectively Art 10.2 of the EMC
Council Directive EN55104: 1995, Category II.
Tested to EN61008-1:1994 & A2 & A11, EN61008-2-1/08.94,
IEC 884-1/06.94 & IEC 884-1/A1/12.94.
Complies with draft standard 23E/263/FDIS for portable RCD
products. Complies with low voltage directive 73/23/EEC and
93/68/EEC.
Cat 952S
Rewirable RCD Plug, 16A
The PDL Elimit rewirable RCD plug is designed for attachment to appliance
cords providing earth-fault protection for the user. The plug is also suitable for
use in French-style socket outlets and wiring of the unit is as easy as any
conventional plug.
Rated Voltage: 250V a.c., 50Hz
Rated Current: 16A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP3X
Type Tested to: Certified to para 5.2 EMVG respectively Art 10.2 of the EMC
Council Directive EN55104: 1995, Category II.
Tested to EN61008-1:1994 & A2 & A11, EN61008-2-1/08.94,
IEC 884-1/06.94 & IEC 884-1/A1/12.94.
Complies with draft standard 23E/263/FDIS for portable RCD
products. Complies with low voltage directive 73/23/EEC and
93/68/EEC.
FI
T E C H N I C A L S P E C I F I C A T I O N S T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
geprfte
Si cherhei t TV R h e i n l a n d
FI geprfte
Si cherhei t TV R h e i n l a n d
19
Cat 56C216D/RCD
RCD Protected Socket Outlet, 16A, IP66
Cat 56C216D/RCD provides IP66 environmental and earth-fault protection for
the 16A Socket outlet. It is suitable for use in conditions where dust and
water pose a potential hazard and features double-pole switching to protect
the appliance user against an earth-fault even in the situation where Active
and Neutral have been reversed.
Rated Voltage: 230 - 240V a.c., 50Hz
Rated Current: 16A - Socket Outlet, 20A - RCD Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66 when flaps are closed
Dimensions: 200 x 100 x 75mm
Type Tested to: EN61008:1994 (relevant clauses)
IEC529:1989
CEE7: 1963
T E C H N I C A L S P E C I F I C A T I O N S
Cat 56C216F/RCD
RCD Protected Socket Outlet, 10A, IP66
Cat 56C216/RCD provides IP66 environmental and earth-fault protection for
the 16A socket outlet with pin-type earthing contacts, predominantly used in
France. It is suitable for use in conditions where dust and water pose a
potential hazard and features double-pole switching.
Rated Voltage: 240V a.c., 50Hz
Rated Current: 16A - Socket Outlet, 20A - RCD Protected Circuit
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP66 when flaps are closed
Dimensions: 200 x 100 x 75mm
Type Tested to: EN61008:1994 (relevant clauses)
IEC529:1989
CEE7:1963
T E C H N I C A L S P E C I F I C A T I O N S
IP66 INDUSTRIAL SWITCHGEAR
EUROPEAN PRODUCT
20
ADAPTOR
NORTH AMERICAN PRODUCT
Cat 951U-3
Plug-in GFCI Adaptor
The PDL plug-in GFCI adaptor provides an earth-fault protected power source
through three socket outlets. It is suitable for use with most portable electric
tools and appliances.
Rated Voltage: 120V a.c.
Rated Current: 15A
Rated Tripping Current: 6mA
Rated Tripping Time: 30ms
Type Tested to: UL 943
CSA C 22.2 No. 144M91
Cat 952U
Rewirable GFCI Plug
The PDL rewirable GFCI plug is designed for attachment to appliance cords
to provide earth-fault protection. The unit is as easy to wire as a standard
plug. With NEMA5 environment protection, it is ideal for use in situations
where dust and water pose a potential problem.
Rated Voltage: 120V a.c.
Rated Current: 15A
Rated Tripping Current: 6mA
Rated Tripping Time: 30ms
Environmental Protection: NEMA 5
Type Tested to: UL 943
CSA C 22.2 No. 144M91
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
REWIRABLE PLUG

21
OEM PRODUCT
CORDSET RCD UNITS
Cat 955RW-30
Rewirable Cordset, 30mA
Features:
IP56 construction.
Screw connections.
Universal - suitable for all countries of the world.
Designed to meet world standards. Complies with all relevant European standards
and requirements.
Rated Voltage: 250V a.c.
Rated Current: 16A
Rated Tripping Current: 30mA
Average Tripping Time: 30ms
Environmental Protection: IP56. IP44 for SEMKO approved version.
Type Tested to: AS/NZS:3175.1:1994
EN61008-1:1984 & A2 and A11, EN61008-2-1:1994.
Complies to draft standard 23E/263/FDIS.
Cat 955RW-10
Rewirable Cordset, 10mA
Features:
IP56 construction.
Screw connections.
Universal - suitable for all countries of the world.
Designed to meet world standards. Complies with all relevant European standards
and requirements.
Rated Voltage: 250V a.c.
Rated Current: 16A
Rated Tripping Current: 10mA
Average Tripping Time: 30ms
Environmental Protection: IP56. IP44 for SEMKO approved version.
Type Tested to: AS/NZS:3175.1:1994
EN61008-1:1984 & A2 and A11, EN61008-2-1:1994.
Complies to draft standard 23E/263/FDIS.
Cat 955RWU
Rewirable Cordset, 6mA
Features:
Rainproof.
Screw connections.
Universal - suitable for all countries of the world.
Designed to meet world standards.
Rated Voltage: 120V a.c.
Rated Current: 15A
Rated Tripping Current: 6mA
Average Tripping Time: 30ms
Environmental Protection: NEMA 5
Type Tested to: UL943: Third Edition
Cat 596PM
RCD Adaptor Plate
Tough polycarbonate construction. Large terminals. Designed with the
appliance manufacturer in mind. Small size to fit a wide range of designs.
Rated Voltage: 240V a.c.
Rated Current: 20A
Rated Tripping Current: 10 or 30mA
Average Tripping Time: 30ms
Type Tested to: AS3190:1997
AS3100:1994
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
T E C H N I C A L S P E C I F I C A T I O N S
ADAPTOR PLATE
T E C H N I C A L S P E C I F I C A T I O N S

22
Developing Special Products for
International Clients
Elimit RCDs are designed and engineered in New Zealand
by PDL Holdings Ltd Engineering Centre, which has IS0
9001 quality management systems certified by Telarc (NZ)
and ASTA (UK).
PDL is a world leader in electrical product design and
manufacturing, with a constant focus on international
market needs.
PDL specialises in totally original and dynamic designs
which, coupled with in-house tooling and sophisticated
engineering techniques, have put PDL at the forefront of
RCD technology.
PDLs experienced engineering staff will work with any
international clients to develop RCD products specific to
their market requirements.
PDL A WORLD LEADER IN RCD TECHNOLOGY
PDL launches new products at international trade fairs such as ElectroTech in the United Kingdom and the Hannover Trade Fair.
Approval Marks
Some of the RCDs/GFCIs in this catalogue have achieved
these prestigious marks: SEMKO, FIMCO, NEMKO, KEMA,
TUV, UL and CSA.
Products for the European markets carry the CE mark.
For Australian and New Zealand markets, approval of RCDs
is mandatory, based on AS 3190 and AS 3100.
FI

geprfte
Si cherhei t TV R h e i n l a n d
22
23
Independent third party testing,
your guarantee of quality
The design and manufacture of products by PDL
Industries has always been backed by third party
testing and development facilities.
PDL uses Parkside Laboratories, an independent IANZ-
registered electrical laboratory, for its product testing
and IANZ-endorsed test reports to ensure international
product acceptance.
Parkside Laboratories offers testing, calibration and
certification services in the fields of electrical, EMC,
environmental, calibration and metrology, with test
procedures performed in accordance with ISO Guide
25 1990 and ISO 9002 1987. Their in-house Quality
Management System meets International Accreditation
New Zealand (formerly known as TELARC) standards,
ensuring that all procedures meet or exceed the
requirements of the New Zealand Code of Laboratory
Management Practice and through their laboratory in
Melbourne, Australia the National Association of
Testing Authorities (NATA).
An independent International Accreditation New Zealand registered electrical laboratory is used for product testing to ensure
compliance to international standards and product quality.
INTERNATIONAL TESTING SYSTEMS
The installation of a new, high-power short circuit test
facility at the Melbourne lab has enabled Parkside
Laboratories to extend the range of NATA accredited
test facilities on offer to industry. The new test centre is
the only privately funded facility of its type in Australia.
As an International Accreditation New Zealand
registered laboratory, Parkside Laboratories test
results are recognised and accepted by other
accreditation authorities in the following countries:
Australia, the United States of America, Ireland, the
United Kingdom, Portugal, Spain, France, Belgium, the
Netherlands, Germany, Austria, Switzerland, Italy,
Denmark, Norway, Sweden, Finland, China, Chinese
Taipei, Hong Kong, Singapore and
South Africa.
This combination of research, development and quality
assurance has underpinned the current success of PDL
Holdings ten subsidiary companies and their continued
further growth.
23
24
THE PDL GROUP
OF COMPANIES
For 60 years, the PDL Group of
Companies has built an enviable
international reputation founded
on the concept that continuous
quality is quality you trust.
PDL is globally recognised for
manufacturing the very best in
electrical accessories, industrial
switchgear, AC variable speed
drives, custom plastic products
and electrical consumer
appliances to the highest
international standards. PDL
products are now distributed to
over 40 countries including
New Zealand, Australia, the United
Kingdom, Europe, Asia, North
America, the Pacific and the
Middle East.
Continuous investment in research
and development has provided the
PDL Group with some of the most
sophisticated world-wide
technology and this, together with
innovation, design excellence and
independent third-party quality
assurance schemes, has ensured
PDL an excellent reputation in the
international market.
The commitment to R&D has
underpinned the current success
of PDL Holdings ten subsidiary
companies and their continued
further growth. Currently, the
Group employs 2100 people over
three continents - Australasia,
Asia and Europe and has an
annual turnover in excess of
$NZ360 million.
PDL GROUP PRODUCTS
PDL electrical wiring accessories for domestic, commercial and industrial applications,
including PDL 600 Designer Series.
PDL PIR Sensors, PDL Residual Current Devices and PDL Powerboards.
Goldair fan heaters and cooling fans.
Modempak cable management and distribution products for the Data and
Telecommunications industries.
AC Motor Speed Controllers including Xtravert, Microdrive-3, Microdrive-i and
Microdrive-Elite, Nu-Start AC Motor Soft Starters.
D-PRO Air Circuit Breakers, CFS Fuse Switch Units, Current Transformers, Power Analysers,
Megatiker Moulded Case Circuit Breakers and various fusegear.
Specialist plastic custom moulding including injection and blow moulded bottles, packs and
closures for all sectors of the packaging industry.
ELIMIT-3/98
RTM
PDL HOLDINGS LTD THE GROUP
Head Office: P O Box 1367, Christchurch, New Zealand.
Telephone: +64-3-338 9059, Fax: +64-3-339 1773.
Email: berryn@pdl.co.nz
PDL Website: www.pdl.co.nz
Manufacturers of Electrical Products
Distributed internationally by:
PDL INDUSTRIES LTD Continuous quality is quality you trust
PDL Industries Limited,
Telarc Reg. No. 061
registered to ISO 9002.
NATIONAL
ACCREDITATION
OF CERTIFICATION
BODIES
ISO 9002
CERT NO. 11595
Q
U
A
L
IT
Y
A
S
S
E
S
S
E
D
REGISTERED
SUPPLIER

Você também pode gostar