Você está na página 1de 50

...

the precision signal conditioning company


ISO9001
DE WE - MDA Q s e r i e s
www. dewet r on. com
T e c h n i c a l r e f e r e n c e m a n u a l
A u t o m o t i v e
E n e r g y & P o w e r A n a l y s i s
F i e l d S e r v i c e
E n v i r o n m e n t a l
R e s e a r c h & D e v e l o p m e n t
Copyright DEWETRON elektronische Messgeraete Ges.m.b.H.
This document contains information which is protected by copyright. All rights are reserved. Reproduction,
adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws.
All trademarks and registered trademarks are acknowledged to be the property of their owners.
3 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Technical Reference
Content
General Information, Safety Instructions 5
Warranty Information 5
Support 5
Printing History 5
Safety symbols in the manual 6
Safety instructions for all DEWETRON systems 7
General module information 9
Calibration information 9
MDAQ series overview 11
Composite confgurations of MDAQ series 11
MDAQ-SUB-Module function overview 12
Filter code table of optional MDAQ-Filters 13
Connectors and solder jumpers 13
Address settings 14
MDAQ channel addressing 16
Changing the front panels 16
MDAQ-DIRECT 17
MDAQ-V 19
Amplifer specifcations 19
Input connection 20
Common voltage range limitation 20
Connectors 21
MDAQ-SUB-V-200-x 23
Amplifer specifcations 23
Internal signal processing 24
Pin assignment of the input connectors 24
Typical sensor connection 25
Common mode voltage range 26
Amplifer specifcations 27
MDAQ-SUB-ACC 27
Input connection 28
Pin assignment of the input connectors 29
Amplifer specifcations 31
4
Technical Reference
MDAQ-SUB-ACC-A-BNC 31
Input connection 32
Typical sensor connection 33
Pin assignment of the input connectors 33
MDAQ-SUB-ACC-x-MD 35
Specifcations 35
Input connection 36
Pin assignment 36
MDAQ-SUB-BRIDGE-D 37
Specifcations 37
Internal signal processing 38
Pin assignment of the input connectors 38
Full bridge signal connection 39
Half bridge signal connection 39
Sensor connection 40
MDAQ-SUB-STG-D 41
Specifcations 41
Internal signal processing 42
Full bridge signal connection 43
Half bridge signal connection 43
Quarter bridge signal connection 43
Pin assignment of the input connectors 44
MDAQ-FILT-5-Bx 45
Filter specifcations 45
Step response of 100 Hz flter 46
Output connector 46
MDAQ-FILT-10-xx 47
Filter specifcations 47
Connection 48
MDAQ-AAF4-5-BU 49
Filter specifcations 49
Step response of 100 Hz flter 50
5 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
The information contained in this document is subject to change without notice.
DEWETRON elektronische Messgeraete Ges.m.b.H. (DEWETRON) shall not be liable for any errors
contained in this document. DEWETRON MAKES NO WARRANTIES OF ANY KIND WITH REGARD
TO THIS DOCUMENT, WHETHER EXPRESS OR IMPLIED. DEWETRON SPECIFICALLY DISCLAIMS
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
DEWETRON shall not be liable for any direct, indirect, special, incidental, or consequential damages,
whether based on contract, tort, or any other legal theory, in connection with the furnishing of this document
or the use of the information in this document.
Warranty Information
A copy of the specifc warranty terms applicable to your DEWETRON product and replacement parts can be
obtained from your local sales and service offce.
Support
For any support please contact your local distributor frst or DEWETRON directly.
For Asia and Europe, please contact: For the Americas, please contact:
DEWETRON Ges.m.b.H. DEWETRON, Inc.
Parkring 4 PO Box 1460
A-8074 Graz-Grambach Charlestown, RI 02813
AUSTRIA U.S.A.
Tel.: +43 316 3070 Tel.: +1 401 364 9464
Fax: +43 316 307090 Toll-free: +1 877 431 5166
Email: support@dewetron.com Fax: +1 401 364 8565
Web: http://www.dewetron.com Email: support@dewamerica.com
Web: http://www.dewamerica.com
The telephone hotline is available The telephone hotline is available
Monday to Friday between Monday to Friday between
08:00 and 17:00 CET (GMT +1:00) 08:00 and 17:00 GST (GMT -5:00)

Restricted Rights Legend
Use austrian law for duplication or disclosure.
DEWETRON GesmbH
Parkring 4
A-8074 Graz-Grambach / Austria
Printing History
Please refer to the page bottom for printing version.
Copyright DEWETRON elektronische Messgeraete Ges.m.b.H.
This document contains information which is protected by copyright. All rights are reserved. Reproduction,
adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright
laws.
All trademarks and registered trademarks are acknowledged to be the property of their owners.
Notice
General Information, Safety Instructions
6
Safety symbols in the manual


Indicates hazardous voltages.
WARNING Calls attention to a procedure, practice, or condition that could cause bodily
injury or death.

CAUTION Calls attention to a procedure, practice, or condition that could possibly cause
damage to equipment or permanent loss of data.
WARNINGS

The following general safety precautions must be observed during all phases of operation, service, and
repair of this product. Failure to comply with these precautions or with specifc warnings elsewhere in this
manual violates safety standards of design, manufacture, and intended use of the product. DEWETRON
Elektronische Messgeraete Ges.m.b.H. assumes no liability for the customers failure to comply with these
requirements.
All accessories shown in this document are available as option
and will not be shipped as standard parts.
Safety instructions
7 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Safety instructions for all DEWETRON systems
The DEWETRON data acquisition systems may only be installed by experts.
Read your manual before operating the system.
Observe local laws when using the instrument.
Ground the equipment: For Safety Class 1 equipment (equipment having a protective earth terminal),
a non interruptible safety earth ground must be provided from the mains power source to the product
input wiring terminals or supplied power cable.
DO NOT operate the product in an explosive atmosphere or in the presence of fammable gases or
fumes.
DO NOT operate damaged equipment: Whenever it is possible that the safety protection features built
into this product have been impaired, either through physical damage, excessive moisture, or any
other reason, REMOVE POWER and do not use the product until safe operation can be verifed by
service-trained personnel. If necessary, return the product to a DEWETRON sales and service offce
for service and repair to ensure that safety features are maintained.
Keep away from live circuits: Operating personnel must not remove equipment covers or shields.
Procedures involving the removal of covers or shields are for use by service-trained personnel only.
Under certain conditions, dangerous voltages may exist even with the equipment switched off. To
avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal
unless you are qualifed to do so.
DO NOT service or adjust alone. Do not attempt internal service or adjustment unless another person,
capable of rendering frst aid and resuscitation, is present.
DO NOT substitute parts or modify equipment: Because of the danger of introducing additional
hazards, do not install substitute parts or perform any unauthorized modifcation to the product. Return
the product to a DEWETRON sales and service offce for service and repair to ensure that safety
features are maintained.
Before opening the instrument (experts only) or exchanging the fuse in the power module disconnect
power!
Dont touch internal wiring!
Dont use higher supply voltage than specifed!
Use only original plugs and cables for harnessing.
The power-cable and -connector serve as Power-Breaker.
For safety reasons max. 50 V may be applied to modules with BNC input-connectors!
Refer to the regulation of maximum allowable touch potential.
Safety of the operator and the unit depend on following these rules.
Safety instructions
8
General System Information
Notes
9 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Calibration information
All DEWETRON MDAQ-modules are calibrated at 25 C and meet their specifcations when leaving the
factory. The time interval for recalibration depends on environmental conditions. Typically, the calibration
should be checked once a year.
Calibration certifcates are available from DEWETRON as an option. DEWETRON offers two types:
ISO traceable DEWETRON certifcate
Calibration certifcate according to KD (equivalent to DKD)
This manual contains no calibration information. For self calibration, there is a separate Calibration Manual
available.
General module information
General module information
10
Notes
11
MDAQ series overview
MDAQ series overview
DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Composite confgurations of MDAQ series
Direct voltage input
Input
Channel 0 - 15
MDAQ-DIRECT
Simple voltage input
Input
Filter (optional)
MDAQ-FILT-5
MDAQ-AAF4-5-BU
Channel 0 - 15
MDAQ-V-100-BNC
MDAQ-V-10-BNC
MDAQ-FILT-10
Signal Conditioning Amplifiers with 5V output
Channel 0 - 7 Channel 8 - 15
Input MDAQ-SUB-V-200-D MDAQ-SUB-V-200-D
MDAQ-SUB-V-200-BNC MDAQ-SUB-V-200-BNC
MDAQ-SUB-ACC-BNC MDAQ-SUB-ACC-BNC
MDAQ-SUB-ACC-A-BNC MDAQ-SUB-ACC-A-BNC
MDAQ-SUB-ACC-A-MD MDAQ-SUB-ACC-A-MD
MDAQ-SUB-BRIDGE-D MDAQ-SUB-BRIDGE-D
MDAQ-SUB-STG-D MDAQ-SUB-STG-D
BASE
Filter (optional)
1) BU..Butterworth, BE..Bessel characteristics
MDAQ-FILT-10-xx
(MDAQ-BASE-10)
MDAQ-BASE-5
MDAQ-FILT-5-xx
1)
MDAQ-AAF4-5-BU
12
MDAQ Series overview
MDAQ series overview
M
D
A
Q
-
S
U
B
-
M
o
d
u
l
e

F
u
n
c
t
i
o
n

O
v
e
r
v
i
e
w
M
D
A
Q
-
V
-
x
x
M
o
d
u
l
e

T
y
p
e
A
C
C
A
C
C
-
A
V
2
0
0
-
B
N
C
V
2
0
0
-
D
B
R
I
D
G
E
S
T
G
V
-
1
0
V
-
1
0
0
T
y
p
i
c
a
l

a
p
p
l
i
c
a
t
i
o
n
I
n
p
u
t

R
a
n
g
e
s
:

2
,
5
5
1
0
2
0

m
V

2
5
5
0
1
0
0
2
0
0

m
V

0
,
1
2
5
0
,
2
5
0
,
5
1

V

1

V
1
,
2
5
2
,
5
5
1
0

V

1
0

V
1
0

V
2
,
5
5
1
0
2
0

V

1
0
0

V
2
5
5
0
1
0
0
2
0
0

V

H
i
g
h

P
a
s
s

F
i
l
t
e
r

1
3
.
4

H
z
0
.
1
5

H
z
0
.
1
5
H
z
H
i
g
h

P
a
s
s

F
i
l
t
e
r

2
3
.
4

H
z
D
i
f
f
e
r
e
n
t
i
a
l

I
n
p
u
t

F
u
l
l

B
r
i
d
g
e

H
a
l
f

B
r
i
d
g
e

Q
u
a
r
t
e
r

B
r
i
d
g
e

3
5
0

O
h
m

Q
u
a
r
t
e
r

B
r
i
d
g
e

1
2
0

O
h
m

I
n
t
e
r
n
a
l

S
h
u
n
t
5
0
k
/
1
0
0
k
M
D
A
Q
-
F
I
L
T
-
x
x

S
u
p
p
o
r
t

T
E
D
S

C
o
n
s
t
a
n
t

C
u
r
r
e
n
t

4

o
r

8

m
A
4

o
r

8

m
A
B
a
n
d
w
i
d
t
h
3
0
0

k
H
z
3
0
0

k
H
z
3
0
0

k
H
z
3
0
0

k
H
z
3
0

k
H
z
3
0

k
H
z
6
5

k
H
z
2
5
0

k
H
z
P
r
o
g
r
a
m
m
a
b
l
e

E
x
c
i
t
a
t
i
o
n
0

t
o

1
2

V
0

t
o

1
2

V
0

t
o

1
2

V
S
t
r
a
i
n

G
a
g
e

A
m
p
l
i
f
i
e
r
S
i
m
p
l
e

f
r
o
n
t
-
e
n
d
S i n g l e C h a n n e l F u n c t i o n s
I
C
P


S
e
n
s
o
r
s

V
o
l
t
a
g
e

S
i
g
n
a
l

c
o
n
d
i
t
i
o
n
i
n
g
G r o u p
C h a n n e l
F u n c t i o n s
MDAQ-SUB-Module function overview
S
i
n
g
l
e

c
h
a
n
n
e
l

f
u
n
c
t
i
o
n
s
:

c
a
n

b
e

s
e
t

f
o
r

e
a
c
h

c
h
a
n
n
e
l

s
e
p
e
r
a
t
e

G
r
o
u
p

c
h
a
n
n
e
l

f
u
n
c
t
i
o
n
s
:

c
a
n

b
e

s
e
t

f
o
r

o
n
e

S
U
B

m
o
d
u
l
e
13
MDAQ series overview
DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Filter code table of optional MDAQ-Filters
Optional Mdaq Filter
-3dB 2nd Order 4th Order
Frequency FILT-10 FILT -10-S1 FILT-5-BU FILT-5-BU-S1 FILT5-BE AAF4-5
10 Be/Bu Be/Bu Bu Be
25 Be/Bu
30 Be/Bu Be/Bu Bu Be
35 Be/Bu
50 Be/Bu
100 Be/Bu Be/Bu Bu Bu Be Bu
250 Be/Bu
300 Be/Bu Be/Bu Bu Be
350 Be/Bu
500 Be/Bu
1k Be/Bu Be/Bu Bu Bu Be Bu
3k Be/Bu
10k Be/Bu Bu Bu Be Bu
30k Be/Bu Bu Bu
100k Be/Bu Bu Bu
300k Be Be
bypass > 700 kHz > 700 kHz > 700 kHz > 700 kHz

Be .. Bessel characteristics
Bu .. Butterworth characteristics
Connectors and solder jumpers
1 Additional sensor supply for sub-amplifer
2 16 channel single ended analog output

3 Base address selection
4 RS-485 termination (short if this is the last board)
5 Short this solder jumper if RS-485 from DEWE-ORION-1624 is used (set base address to 0).

1 2 3 1 4 5
SCL
SDA
+5 V
DGND
DGND
A
A
B
B
DGND
TX
RX
FLT (GND)
DP
DM
Filter connector
RS-485
RS-232
USB
For internal usage only
n.c.
+15 V
GND
-15 V
n.c.
Power connector
CH 0 CH 2 CH 4 CH 6 CH 8 CH 10 CH 12 CH 14
14
MDAQ Series overview
MDAQ series overview
Address settings
If you use DEWE-ORION-16xx cards, each MDAQ Module is controlled directly via the RS-485 interface of
the associated card. When using DEWE-ORION-32xx cards each card controls and converts two MDAQ
modules. Set all address selectors to 0. An additional EPAD module has to be connected to the frst MDAQ
Module. This simplifes the hardware settings in the data acquisition software.
DEWE-ORION-08xx
CH 0 to 7
RS-485 Interface
RS-485 Interface
Optional
EPAD Module
DEWE-ORION-08xx
CH 8 to 15
DEWE-ORION-08xx
CH 16 to 23
RS-485 Interface
DEWE-ORION-08xx
CH 24 to 31
module
address
0
module
address
0
PCB for
cross wiring
PCB for
cross wiring

DEWE-ORION-16xx
Analog channels 0 to 15
RS-485 Interface
RS-485 Interface
Optional
EPAD Module
DEWE-ORION-16xx
Analog channels 16 to 31
RS-485 Interface
DEWE-ORION-16xx
Analog channels 32 to 47
RS-485 Interface
DEWE-ORION-16xx
Analog channels 240 to 255
RS-485 Interface
module
address
0
module
address
0
module
address
0
module
address
0

DEWE-ORION-32xx
Analog channels 0 to 15
RS-485 Interface
RS-485 Interface
Optional
EPAD Module
Analog channels 16 to 31
RS-485 Interface
DEWE-ORION-32xx
Analog channels 224 to 239
RS-485 Interface
Analog channels 240 to 255
RS-485 Interface
module
address
0
module
address
0
module
address
0
module
address
0

The block diagram shows the address
settings when using standard A/D converter
cards. The communication can be done via
RS-232, RS-485 or USB interface. You can
connect an additional EPAD Module if you
use the RS-485 interface. The onboard
RS-232 to RS-485 converter is improperly
to communicate with EPAD modules!
15
MDAQ series overview
DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
RS-232,
RS-485
or USB
RS-232 to
RS-485
converter
A/D converter card
CH 0 to CH 15
PCB for
cross wiring
A/D converter card
CH 16 to CH 31
PCB for
cross wiring
A/D converter card
CH 32 to CH 47
PCB for
cross wiring
A/D converter card
CH 240 to CH 255
PCB for
cross wiring
Optional
EPAD
Modules
RS-485
module
address
0
module
address
1
module
address
2
module
address
F
For special wiring see DEWE-xxxx systems manual appendix B3.
16
MDAQ Series overview
MDAQ series overview
MDAQ channel addressing
Each MDAQ-V-xx module has 16 analog input channels, which can be independent confgured. Since only
the base address of the MDAQ-V-xx is changeable the access to the input channel confguration is in the
range between (Module address x 16) to (Module address x 16) +15.
Example:
Module address : channel number range:
00 Ch 0 - Ch 15 (Hex: 0x00..0x0F)
01 Ch 16 - Ch 31 (Hex: 0x10..0x1F)
02 Ch 32 - Ch 47 (Hex: 0x20..0x2F)
... ...
0F Ch 240 - Ch 255 (Hex: 0x0F..0xFF)
MDAQ-Base address switch
Changing the front panels
(DEWE-MDAQ-PCI-128 systems only)
Lift the connectors carefully with a screwdriver!
To avoid any damage please don't touch the PCB!
17 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
MDAQ-DIRECT
16 channel direct input connection to AD board
BNC input connectors
Size compatible with MDAQ-SUB-x amplifer series
In MDAQ-DIRECT confguration, the input connectors are directly connected to the A/D converter.
MDAQ-DIRECT-BNC
Gain 1, direct input to A/D card
Input 16 channels
Sensor connection BNC female
Output connector 68-pin Amplimite series (AMP Nr. 174339-6)
Dimensions (W x D x H) 175 x 61 x 24 mm (6.9 x 2.4 x 0.9 in.)

1 3 5
2 4 6
J1 J2
MDAQ-DIRECT bottom view
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
NC.
NC.
CH. 15+
GND
NC.
NC.
CH. 14+
CH. 13+
CH. 12+
CH. 11+
CH. 10+
CH. 9+
CH. 8+
CH. 7+
CH. 6+
CH. 5+
CH. 4+
CH. 3+
CH. 2+
CH. 1+
CH. 0+
NC.
NC.
NC.
NC.
NC.
NC.
GND
NC.
NC.
NC.
NC.
NC.
NC.
NC.
GND
NC.
RS-485 A
RS-485 B
NC.
NC.
NC.
TRIG
CLK
NC.
NC.
NC.
NC.
+5V DC
NC.
DGND
CH. 15-
CH. 14-
CH. 13-
CH. 12-
CH. 11-
CH. 10-
CH. 9-
CH. 8-
CH. 7-
CH. 6-
CH. 5-
CH. 4-
CH. 3-
CH. 2-
CH. 1-
CH. 0-
GND
Output connector (J1)
J2 is prepared for some dedicated signals of the DEWE-ORION-
1624. The RS-485 interface, the clock and trigger signal can be
easy wired to this connector. J2 pin assignment:
1 CLK
2 +5 V
DC

3 RS-485 B
4 TRIG
5 RS-485 A
6 DGND
One of the 16 solder jumpers to
connect the CHx- pin to GND
MDAQ-DIRECT
18
Notes
MDAQ-DIRECT
19 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Analog input amplifer MDAQ-V-10, MDAQ-V-100 and MDAQ-V-250
16 channel differential voltage amplifer
Input range up to 250 V
Common mode voltage range up to 280 V
High common mode rejection (86 dB)
Bandwidth up to 250 kHz
Amplifer specifcations
MDAQ-V-10 MDAQ-V-100
Input ranges 1V, 10V 10V, 100V
Input type differential differential
Amplifier Gain 0 dB (1) / 20 dB (10) -20 dB (0.1) / 0 dB (1)
Input impedance IN+ 200 kOhm 550 kOhm
Input impedance IN- 100 kOhm 500 kOhm
DC Accuracy
(1)
0.05 % of Range 0.05 % of Range
Analog Out Accuracy 0.15 % of Range 0.15 % of Range
Gain drift 15 ppm/K 15 ppm/K
Offset Drift typ [max] 1V range: 3V/K [10V/K] 10V range: 30V/K [100V/K]
10V range: 4V/K [20V/K] 100V range: 40V/K [200V/K]
Input noise @ full bandwidth 1V range: 27V
RMS
10V range: 270V
RMS
10V range: 40VRMS 100V range: 400VRMS
SNR @ 50kHz bandwidth 1V range: 87dB 10V range: 87dB
10V range: 105dB 100V range: 105dB
CMR @ 50 Hz typ. 80 dB typ. 86 dB
Channel separation (@ 10 kHz) 110 dB 110 dB
Bandwidth ( -3 dB) DC to 65 kHz DC to 250 kHz
Common mode voltage range 20 V 110 V
Overvoltage protection 100 V 250 V
Output voltage 10 V 10 V
Programming interface RS-232 or RS-485 RS-232 or RS-485
Power supply
(2)
7.5 V to 15 V 7.5 V to 15 V
Power consumption typ. 3 W typ. 3 W
Sensor connection BNC female BNC female
Output connector
Dimensions (W x D x H)
(1)
Correction values are stored in the MDAQ-V series and can be used as scaling values
(2)
Power supply has to be 3 V higher than output voltage
68-pin Amplimite series (AMP Nr. 174339-6)
175 x 61 x 24 mm (6.9 x 2.4 x 0.9 in.)
MDAQ-V
20
Input connection
Block diagram for one of the 16 identical analog inputs.

20 kOhm
(3)
50 kOhm
(2)
100 kOhm
(1)
500 kOhm
(3)
500 kOhm
(2)
100 kOhm
(1)
500 kOhm
(3)
500 kOhm
(2)
100 kOhm
(1)
22 pF
(3)
10 pF
(2)
22 pF
(1)
2
0

k
O
h
m

(3
)
5
0

k
O
h
m

(2
)
1
0
0

k
O
h
m

(1
)
2
2

p
F

(3
)
1
0

p
F

(2
)
2
2

p
F

(1
)
PGA
(Gain 1/10)

(1)
MDAQ-V-10

(2)
MDAQ-V-100

(3)
MDAQ-V-250
Optional
Filter Board
to A/D board
RS-232
RS-485
CH x (-)
CH x (+)
_
+
P

Input circuit
When measuring foating input sources (e.g. batteries) it is necessary to connect CH x (-) to analog ground.

MDAQ-V Floating source
CH x (+)
Connection to analog GND
CH x (-)
Input connection with foating sources
Common voltage range limitation
MDAQ-V-10
All 16 channels are differential inputs with 200 kOhm impedance. The common voltage range of each input is
limited to 20 V.
Examples for common voltages:
CH x (+) = +20 V, CH x (-) = +5 V, voltage difference = 15 V, allowed
CH x (+) = +30 V, CH x (-) = +15 V, voltage difference = 15 V, not allowed (CH x (+) exceeds 20 V)
MDAQ-V-100
All 16 channels are differential inputs with 550 kOhm impedance. The common voltage range of each input is
limited to 110 V.
Examples for common voltages:
CH x (+) = +95 V, CH x (-) = +5 V, voltage difference = 90 V, allowed
CH x (+) = +130 V, CH x (-) = +40 V, voltage difference = 90 V, not allowed (CH x (+) exceeds 110 V)
MDAQ-V
21 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Connectors
NC.
+15 V
GND
-15V
NC.
F
i
l
t
e
r

P
o
w
e
r
S
C
L

S
D
A

+
5
V

D
G
N
D

L
E
D

T
o

P
C

R
x

T
o

P
C

T
x

G
N
D

N
C
.

N
C
.
A

A

B

B

G
N
D

F
o
r

I
n
t
e
r
n
a
l

u
s
e
a
g
e

o
n
l
y

MDAQ-V Address
switch
Output voltage range selection,
open: 5 VDC short: 10 VDC
(default)
MDAQ-V bottom view
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
NC.
NC.
CH. 15+
GND
NC.
NC.
CH. 14+
CH. 13+
CH. 12+
CH. 11+
CH. 10+
CH. 9+
CH. 8+
CH. 7+
CH. 6+
CH. 5+
CH. 4+
CH. 3+
CH. 2+
CH. 1+
CH. 0+
NC.
NC.
NC.
NC.
NC.
NC.
GND
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
RS-485 A
RS-485 B
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
Output connector
MDAQ-V
22
Notes
MDAQ-V
23 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Differential voltage amplifer
16 programmable ranges from 0.125 V to 200 V
Bandwidth 300 kHz
Programmable sensor supply 0 to 12 V
High signal to noise ratio
TEDS support
Amplifer specifcations
MDAQ-SUB-V-200-xx
Input voltage range: Divider Off 0.125 V, 0.25 V, 0.5 V, 1 V, 1.25 V, 2.5 V, 5 V, 10 V (common mode voltage up to 12 V)
Divider On 2.5 V, 5 V, 10 V, 20 V, 25 V, 50 V, 100 V, 200 V (common mode voltage up to 250 V)
Input impedance 1 MOhm to GND, 2 MOhm differential
DC accuracy Divider Off without software correction table
0.125 to 1V 0.03% of reading 400V 0.15% of reading 400V
1.25V; 2.5V 0.03% of reading 1mV 0.15% of reading 1mV
5; 10V 0.02% of reading 0.03% of range 0.15% of reading 0.03% of range
2.5 to 20V Divider On 0.06% of reading 8mV 0.25% of reading 8mV
25V; 50V 0.03% of reading 20mV 0.25% of reading 20mV
100; 200V 0.02% of reading 0.03% of range 0.25% of reading 0.03% of range
Gain drift typ. 15 ppm/K (max. 40 ppm/K)
Input offset drift
125 mV to 10 V Divider Off typ. 10 V/K (max. 20 V/K)
2.5 V to 200 V Divider On typ. 100 V/K (max. 200 V/K)
Overvoltage protection 250 V
DC
Bandwidth ( -3 dB) Divider Off 300 kHz (200 kHz at range 0.125 V and 1.25 V)
Divider On 300 kHz (200 kHz at range 2.5 V and 25 V) (30 kHz with MDAQ-BASE-10)
Channel separation @ 10 kHz > 80 dB
CMRR @ 50 Hz (@ 1 kHz) Divider Off > 94 dB (> 80 dB)
Divider On > 70 dB (> 56 dB)
Typ. SNR @ 50 kHz BW Divider Off
0.125 V and 0.25 V > 87 dB
0.5 V to 10 V > 96 dB
2.5 V and 10 V Divider On > 84 dB
10 V to 25 V > 88 dB
25 V to 200 V > 93 dB
Programmable sensor supply
(1)
0 to 12 V short circuit protected; 50mA current limmitation
Sensor supply accuracy
(1)
0.05 % 2 mV
Fixed sensor supply
(1)
15 V (50 mA)
Output voltage 5 V ( 10V with MDAQ-BASE-10)
Output impedance 5 Ohm
Output current 20 mA
Programming interface RS-485, RS-232, USB
Power supply 15 V
Power consumption typ. 4.5 W / 10 W
(1)
Sensor connection BNC or DSUB
(1)
female
Output connector 68-pin Amplimite series (AMP Nr. 174339-6)
Supported TEDS chips
(1)
DS2406, DS2430A, DS2432, DS2433
Dimensions (W x D x H) 200-BNC: 175 x 61 x 30 mm (6.9 x 2.4 x 1.2 in.) 200-DSUB: 175 x 82 x 22 (6.9 x 3.2 x 0.9)

(1)
MDAQ-SUB-V-200-D only!
For safety reasons max. 50 V may be applied to modules with BNC input-connectors!
Refer to the regulation of maximum allowable touch potential.
MDAQ-SUB-V-200-x
24
Internal signal processing
The picture below shows the block diagram of the MDAQ-SUB-V-200-xx
Sub+
Sub-
Sig Out
TEDS
IN +
9
-
p
i
n

D
S
U
B
IN -
EXC
GND
950 k
950 k
50 k
50 k
G=1
G=1
- 15 V
+ 15 V
50 mA
50 mA
1
2
H
O
T
S
H
I
E
L
D
5
9
7
6
4
B
N
C
MDAQ-SUB-V-200-xx MDAQ-BASE-x opt. MDAQ-FILT-x
Differential Amplifier
with Offset and
CMR control
8 gains
MDAQ-BASE-5:
0.5, 1, 2, 4, 8, 10, 20, 40
MDAQ-BASE-10:
1, 2, 4, 8, 10, 20, 40, 80
Sensor
supply
0 to 12 V
TEDS
CONTROL
divider
ON
divider
OFF
divider
OFF
divider
ON

Pin assignment of the input connectors
MDAQ-SUB-V-200-D
1 TEDS
2 IN +
3 Res.
4 GND
5 +15 V
5 4 3 2 1
9 8 7 6
6 Programmable sensor supply 0 to 12 V
7 IN -
8 Res.
9 -15 V
If signals above 60 V may appear, dont use the metal housing of SUBD connector!
MDAQ-SUB-V-200-BNC
Hot: IN +
Shield: IN -
MDAQ-SUB-V-200-x
25 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Typical sensor connection
TEDS
GND
IN+
IN-
+15V
-15V
TEDS
Output
+
-
Supply
+
-
1
4
2
7
5
9
9
-
p
i
n

D
S
U
BConnectors Sensor
6
2
7
4
9
-
p
i
n

D
S
U
BConnectors Sensor
2-wire
4..20 mA
GND
IN+
IN-
50 OHM
Shunt
Resistor
Prog
EXC
Output
+
-
Sensor with differential output
powered by the module Loop powered sensor
Sensor
1
4
2
7
5
9
9
-
p
i
n

D
S
U
BConnectors
TEDS
GND
IN+
IN-
+15V
-15V
4..20 mA
4..20 mA
output
50 OHM
Shunt
Resistor
B
N
C
H
o
t
S
h
i
e
l
d
6
2
7
4
9
-
p
i
n

D
S
U
BConnectors Sensor
GND
IN+
IN-
+12 V
Output
GND
VCC
Current measurement Sensor with common ground
Single ended connection Potentiometric
2
7
4
9
-
p
i
n

D
S
U
BConnectors Floating
Sensor
IN-
GND
IN+
B
N
C
S
y
s
t
e
m

H
o
u
s
i
n
g
Output
+
-
230 V
50 Hz
S
h
i
e
l
d
H
o
t
6
2
7
4
9
-
p
i
n

D
S
U
BConnectors
IN+
IN-
Prog
EXC
GND
100 %
.
.
0 %
MDAQ-SUB-V-200-x
26
Common mode voltage range
In contrast to isolated amplifers the input common voltage range is limited at differential amplifers. The
measurement confguration below shows the possibilities to measure the current of a 24 V supplied system.
C
H
0
IN+
IN-
4A
24V Battery Load
24V
C
H
1
IN+
IN-
0V
Shunt
0.1 M
Shunt
0.1 M
The optimum input range in that case is 500 mV. That will work fne for CH1 in the picture, but not for the
CH0. This channel will exceed the maximum common mode voltage and goto overfow.
MDAQ-SUB-V-200-x
27 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Analog input amplifer MDAQ-SUB-ACC
16 channel ICP

amplifer
Several voltage measurement modes
(AC/DC Coupling, single ended/differential)
Bandwidth up to 300 kHz
Channel separation 96 dB
TEDS support (IEEE 1451.4)
Ideally suited for sound and vibration measurement
Amplifer specifcations
MDAQ-SUB-ACC
Input voltage range 0.125 V, 0.25 V, 0.5 V, 1 V, 1.25 V, 2.5 V, 5 V, 10 V
Gain 0.5, 1, 2, 4, 5, 10, 20, 40
Input modes ICP

or Voltage
Voltage modes single ended or differential
DC or AC coupled (3 Hz standard, on request down to 0.1 Hz)
Input impedance 1 MOhm
DC accuracy without software correction table
0.125 to 1V 0.03% of reading 400V 0.15% of reading 400V
1.25V; 2.5V 0.03% of reading 1mV 0.15% of reading 1mV
5;10V 0.02% of reading 0.03% of range 0.15% of reading 0.03% of range
Gain drift typ. 10 ppm/K (max. 20 ppm/K)
Input offset drift typ. 3 V/K (max. 12 V/K)
Over voltage protection IN+ differential 40 V
IN- differential: max 40 V
IN- Single ended: max 300 mA
Max. common mode voltage IN differential mode: 12 V
Bandwidth ( -3 dB) 300 kHz (200 kHz at range 1.25 V and 0.125 V)
30 kHz with MDAQ-BASE-10
Channel separation @ 10 kHz > 96 dB
CMR @ 50 Hz (@ 1 kHz) > 94 dB (> 80 dB)
Typ. SNR @ 50 kHz bandwidth
Range 0.125 V > 87 dB
Range 0.25 V > 93 dB
Range 0.5 V to 1.25 V > 96 dB
Range 2.5 V to 10 V > 100 dB
Sensor excitation 4 or 8 mA, 5 % up to 24 V
DC
Current noise 150 nA * sqrt (Hz)
Input connectors BNC
Output voltage 5 V, 10 V with MDAQ-BASE-10
Output impedance 5 Ohm
Output current 20 mA
Programming interface RS-485, RS-232
Power supply 15VDC
Power consumption: typ. 10 W (max 12 W @ 8 mA sensor excitation)
Sensor connection: BNC female
Output connector 68-pin amplimite series (AMP Nr. 174339-6)
TEDS DS 2406, DS 2430A, DS 2432, DS2433
MDAQ-SUB-ACC
I
C
P


i
s

a

t
r
a
d
e
m
a
r
k

o
f

P
C
B

P
i
e
z
o
t
r
o
n
i
c
s
,

I
n
c
.
28
Input connection
The picture below shows the principal confguration of the amplifer circuit.


Programmable
AC/DC couling
PGA: 0.5, 1, 2, 4, 5, 10, 20 and 40;
Programmable offset and common
mode rejection adjustment
Programmable
single ended /
differential input
confguration
Programmable current
source (4 / 8 mA) on / off
49 nF
1 M
MDAQ-BASE-x MDAQ-FILT-x
MDAQ-SUB-ACC
TEDS
24 V
Input circuit
The main amplifer consists of a programmable gain amplifer (PGA) with differential inputs. Depending on
the measurement mode (ICP

sensors or voltage) the position of the switches at the input is changed. For all
input channels the confguration can be changed individually except the level of the current source (4 mA or
8 mA). Changing the current range effects all eight sub channels. That means if the source level of channel 0
is set to 8 mA also channel 1 to channel 7 is switched to the same. But for channel 8 to channel 15 a differ-
ent source level can be used.
Signal out
If no flter board is installed, this
feld shows the analog bandwidth
MDAQ-SUB-ACC
29 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
For constant current powered sensors (ICP

mode) the current source is switched on and also the minus


input of the BNC is connected to GND. The input coupling is switched to AC. In that mode also the TEDS
interface circuit is allowed to read out the sensor information out of IEEE 1451.4 compliant sensors.
In all voltage measurement modes the current source is disconnected from the input signal. The position of
the GND switch defnes if the amplifer is used for differential or singled ended input confguration. The al-
lowed input voltage range (common mode voltage) is limited to 13 V.
NOTE: If foating input sources (like batteries) are connected to the MDAQ-SUB-ACC the amplifer has to
be used in single ended confguration (GND-switch ON)! Otherwise the input may be out of the maximum
input voltage range!
In differential mode as well as in single ended mode AC or DC coupling is possible. The standard high pass
flter frequency is 3 Hz in AC-mode. Please contact DEWETRON for other frequencies.
Pin assignment of the input connectors
MDAQ-SUB-ACC-BNC
Hot: IN +
Shield: IN -
MDAQ-SUB-ACC
30
Notes
MDAQ-SUB-ACC
31 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Analog input amplifer MDAQ-SUB-ACC-A
16 channel ICP

amplifer
AC ond DC coupled voltage measurement mode
2 programmable high-pass flters
Bandwidth up to 300 kHz
Channel separation 96 dB
TEDS support (IEEE 1451.4)
Ideally suited for sound and vibration measurement
Amplifer specifcations
MDAQ-SUB-ACC-A
Input voltage range 0.125 V, 0.25 V, 0.5 V, 1 V, 1.25 V, 2.5 V, 5 V, 10 V
Gain 0.5, 1, 2, 4, 5, 10, 20, 40
Input modes ICP

or Voltage
Voltage modes single ended
DC or AC coupled with two selectable high pass filter
(0.15 and 3.4 Hz as standard, others on request)
Input impedance 1 MOhm
DC accuracy without software correction table
0.125 to 1V 0.03% of reading 400V 0.15% of reading 400V
1.25V; 2.5V 0.03% of reading 1mV 0.15% of reading 1mV
5;10V 0.02% of reading 0.03% of range 0.15% of reading 0.03% of range
Gain drift typ. 10 ppm/K (max. 20 ppm/K)
Input offset drift typ. 3 V/K (max. 12 V/K)
Over voltage protection IN+ 40 V
IN- Single ended: max 300 mA
Bandwidth (-3 dB) 300 kHz (200 kHz at range 1.25 V and 0.125 V)
30 kHz MDAQ-BASE-10
Channel separation @ 10 kHz > 96 dB
CMR @ 50 Hz (@ 1 kHz) > 94 dB (> 80 dB)
Typ. SNR @ 50 kHz bandwidth
Range 0.125 V > 87 dB
Range 0.25 V > 93 dB
Range 0.5 V to 1.25 V > 96 dB
Range 2.5 V to 10 V > 100 dB
Sensor excitation 4 or 8 mA, 5 % up to 24 V
DC
Current noise 150 nA * sqrt (Hz)
Input connectors BNC
Output voltage 5 V, 10 V MDAQ-BASE-10
Output impedance 5 Ohm
Output current 20 mA
Programming interface RS-485, RS-232
Power supply 15V
DC
Power consumption: typ. 10 W (max 12 W @ 8 mA sensor excitation)
Sensor connection: BNC female
Output connector 68-pin amplimite series (AMP Nr. 174339-6)
Dimensions (W x D x H) 175 x 61 x 30 mm (6.9 x 2.4 x 1.2 in.)
MDAQ-SUB-ACC-A-BNC
I
C
P


i
s

a

t
r
a
d
e
m
a
r
k

o
f

P
C
B

P
i
e
z
o
t
r
o
n
i
c
s
,

I
n
c
.
32
Input connection
The picture below shows the principal confguration of the amplifer circuit.


TEDS
8 mA
4 mA
1 nF
47 nF
DC
AC 3.4 Hz
AC 0.15 Hz
1 M Ohm
Input
PGA: 0.5, 1, 2, 4, 5, 10, 20 and 40;
Programmable offset
Signal out
MDAQ-SUB-ACC-A MDAQ-BASE-x MDAQ-FILT-x
24 V
Input circuit
MDAQ-SUB-ACC-A-BNC
If no flter board is installed, this
feld shows the analog bandwidth
33 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Typical sensor connection
Accelerometer
Connectors
IN+
IN-
ICP
H
o
t
S
h
i
e
l
d
Sensor
BNC

Connectors
IN+
IN-
Voltage
output
H
o
t
S
h
i
e
l
d
BNC
NOTE: If foating input sources (like batteries) are connected to the MDAQ-SUB-ACC the amplifer has to
be used in single ended confguration (GND-switch ON)! Otherwise the input may be out of the maximum
input voltage range!

Pin assignment of the input connectors
MDAQ-SUB-ACC-A-BNC
Hot: IN +
Shield: IN -
MDAQ-SUB-ACC-A-BNC
34
MDAQ-SUB-ACC-A-BNC
Notes
35 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
MDAQ-SUB-ACC-x-MD
MDAQ-SUB-ACC-x-MICRODOT option
Add on for MDAQ-SUB-ACC and MDAQ-SUB-ACC-A
Microdot sensor input connector
LED sensor check indication
Input multiplexer for calibration signal

Specifcations
MDAQ-SUB-ACC-x-MICRODOT
Input connectors Microdot No. 031-0059-0001
Sensor check (ICP

mode only)
Open U
exc
> 22 V: LED off
Valid 3 V < U
exc
< 21 V: LED green
Short circuit U
exc
< 2 V: LED red
Calibration multiplexer Mechanical relais (NAIS TXS2)
Control connector 10-pin AMP Micro Mate
Power supply +5 V / +12 V
Power consumption typ. 2 W

The MDAQ-INT-ACC-x-MICRODOT board is an add-on for the MDAQ-INT-ACC series. It provides Microdot
input connectors and the possibility to switch the input channels to a free defnable reference signal. Eight
LEDs show the status of the ICP

supply of every channel.


The input multiplexer is realized with a mechanical relay to avoid signal distortions. The status of the
mechanical relay is controlled via a reference voltage control. Low level on the reference voltage control is
for measuring mode, high level on the reference voltage control switches the input channels to the reference
signal. Changing the reference voltage control input affects all eight sub-channels.
Every channel is equipped with a status-LED. It shows the status of the ICP

excitation voltage and also the


sensor supply. If the input channel is open - if there is no sensor connected to the input or the connection is
defective (open circuit) - the ICP

excitation voltage is near the upper limit. In this case the sensor check unit
gives out no voltage and the LED is off. If the input channel is short-circuited the ICP

excitation voltage is
very low and the sensor check unit controls the LED to shine red. Is the ICP

excitation voltage in the valid


range a correct connected ICP

sensor is assumed, the sensor check unit controls the LED to shine green.
The sensor check unit isnt able to check if the sensor measures correct values!
36
MDAQ-SUB-ACC-A-MD
Input connection
The picture below shows the principal confguration of the input multiplexer and the sensor check function.
Sensor
check
Ref.Sig +
Ref.Sig -
Ref.Volt. Ctrl.
Input +
Input -
Sensor Input
To MDAQ-ACC-x amplilfier
Pin assignment
The table below shows the pin assignment of the control connector.
1 Ref. Voltage Exc.+
3 Ref. Voltage Exc.-
5 DGND
7 +5 V
9 Ref. Volt. Ctrl.
Ref. Voltage Sense + 2
Ref. Voltage Sense - 4
DGND 6
+12 V 8
Reserved 10

37 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Analog input amplifer MDAQ-SUB-BRIDGE-D

High accuracy (0.05%) full bridge amplifer
Internal half bridge completion
Input short-circuit function for measuring absolute strain
Bridge and voltage measurement mode
AC/DC coupling (0.16 Hz high pass flter)
TEDS support

Specifcations
MDAQ-SUB-BRIDGE-D
Gain 0.5 to 2000
Input ranges 2.5, 5, 10, 20, 25, 50, 100, 200, 250,500, 1000, 1250, 2500, 5000, 10 000 mV
@ 5 VDC excitation 0.5, 1, 2, 4, 5, 10, 20, 40, 50, 100, 200, 400, 500, 1000 mV/V
Input impedance 1 MOhm
Input noise 3.5 nV * Hz
Typ. input offset drift 0.5 V/K (for ranges < 200 mV)
DC Accuracy High Gain without software correction table
2.5mV;5mV/V;10mV/V;25mV 0.03% of reading 15V [3V/V @5VEXC] 0.15% of reading 15V [3V/V @5VEXC]
20mV 0.03% of reading 0.08% of range 0.15% of reading 0.08% of range
50mV 0.03% of reading 0.05% of range 0.15% of reading 0.05% of range
100mV to 200mV 0.03% of reading 0.03% of range 0.15% of reading 0.03% of range
0.250 to 1V Low Gain 0.03% of reading 400V [80V/V @5VEXC] 0.15% of reading 400V [80V/V @5VEXC]
1.25V; 2.5V 0.03% of reading 1mV 0.15% of reading 1mV
5;10V 0.02% of reading 0.03% of range 0.15% of reading 0.03% of range
Gain drift @ 5 VDC excitation 10 ppm/K of range 0.02 V/V/K
Excitation voltage 0.25, 0.5, 1, 2.5, 5V (default) and 10 VDC software programmable
Excitation accuracy 0.05 % 0.7 mV
Excitation drift 10 ppm/K 50 V/K
Excitation current limit 50 mA/Channel
Excitation protection continuous short to ground
Sensor supply (+15 V) accuracy: -5% to +2%; Each output separately fused; max. current 50 mA/channel
Bridge types 4- or 6-wire full bridge
3- or 5-wire bridge with internal completion (software programmable)
Bridge resistance 120 Ohm to 10 k Ohm
Automatic bridge balance
1)
absolute Voltage mV/V @ 5V EXC m/m @ 5VEXC k=2 Quater bridge
2.5mV to 20mV 10mV 2mV/V 4000m/m
25mV to 200mV 100mV 20mV/V 40000m/m
250mV to 1V 0.5V 100mV/V 200,000m/m
2V to 10V 5V 1000mV/V 2,000,000m/m
Bandwidth (-3dB) 30 kHz
Filters (lowpass) in combination with MDAQ-FILT-xx
Typ. SNR @ 30 kHz [1 kHz] 64 dB [82 dB] @ 1 mV/V
and 5 VDC excitation 82 dB [96 dB] @ 50 mV/V
Typ. CMR @ 0.1 mV/V [1 mV/V] 125 dB [120 dB] @ DC
and 5 VDC excitation 115 dB [110 dB] @ 400 Hz
110 dB [105 dB] @ 1 kHz
Max. common mode voltage range 12 V
Input overvoltage protection 25 VDC
Output voltage 5 V, 10 V with MDAQ-BASE-10
Output resistance < 10 Ohm
Output current max. 5 mA
Output protection continuous short to ground
TEDS hardware support for TEDS (Transducer Electronic Data Sheet)
Supported TEDS chips DS2406, DS2430A, DS2432, DS2433
Power consumption for 16 channels
@ 5 VDC excitation 350 Ohm @ 10V Exc. typ. 15 W
120 Ohm @ 5V typ. 15 W
@ 10 VDC 350 Ohm max. @ 15 W max.
120 Ohm @ 15 W
Standard operating temperature 0C to 70C ( 32F to 158F)
1)
MDAQ-BASE-10A has the half offset adjustment range
MDAQ-SUB-BRIDGE-D combined with MDAQ-BASE-5
38
Internal signal processing
Pin assignment of the input connectors
MDAQ-SUB-BRIDGE-D
1 EXC+
2 IN +
3 Sense
4 GND
5 +15 V (50 mA)
5 4 3 2 1
9 8 7 6
6 Sense+
7 IN -
8 EXC-
9 TEDS
6
1
2
7
4
8
9
3
+Uref
(0..6V)
5
50 mA
G 1, G 50
G = (-1)
Sub+
Sub-
AC/DC
1F
Sig Out
MDAQ-SUB-BRIDGE
Ch
0 .. 7
Sense+
Exc+
In+
In-
GND
Exc-
Sense-
TEDS
Controller
TEDS
+15V out
MDAQ-BASE-x MDAQ-FILT-x
(optional)
Differential Amplifier
with Offset and
CMR control
8 gains
MDAQ-BASE-5:
0.5, 1, 2, 4, 8, 10, 20, 40
MDAQ-BASE-10:
1, 2, 4, 8, 10, 20, 40, 80
MDAQ-SUB-BRIDGE-D
39 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Full bridge signal connection
6-wire sensor connection
(Sense wired at the sensor)
Sens leads (SUB-D: pin 3 and 6) have to be connected!
Half bridge signal connection
5-wire sensor connection
(Sense wired at the sensor)

15 V sensor supply
GND
IN-
15V
(50 mA max)
9 .. 36 V
supply
Signal
OUT
GND
IN+
5
2
7
4
9
-
p
i
n

S
U
B
-
D
4-wire sensor connection
(Sense wired at the connector)
3-wire sensor connection
(Sense wired at the connector)
7
*
* required for AC coupling
7
* required for AC coupling
*
MDAQ-SUB-BRIDGE-D
40
The following table shows how the mV/Vranges are calculated. The ranges depend on the gain and the
excitation voltage
Excitation 0.25 V 0.5 V 1.00 V 2.5 V 5.00 V 10.00 V
Input range
10000 mV
5000 mV 500
2500 mV 500 250
1250 mV 500 250 125
1000 mV 400 200 100
500 mV 500 200 100 50
250 mV 1000 500 250 100 50 25
100 mV 400 200 100 40 20 10
50 mV 200 100 50 20 10 5
25 mV 100 50 25 10 5 2,5
10 mV 40 20 10 4 2 1
'2.5 mV 10 5 2,5 1 0,5 0,25
Bridge module range [mv/V]
Sensor connection
V+
Sense+
MDAQ-SUB-BRIDGE-D Potentiometric Sensor
2
0
0

O
h
m

t
o

1
0

k
O
h
m
IN+
Sense-
V-
Shield
1
6
2
3
8
4
9
-
p
i
n
S
U
B
-
D
Always change the excitation voltage before changing the input range, otherwise you will not get the
required 500 mV/V range.
MDAQ-SUB-BRIDGE-D
41 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
MDAQ-SUB-STG-D
Strain gage amplifer
15 input ranges from 2.5mV to 10V
1mV steps program able excitation from 0 to 12V
Internal Bridge Completion for and Bridge
Internal 50k and 100k Shunt resistor
TEDS support
Specifcations
Gain 0.5 to 2000
Input ranges 2.5, 5, 10, 20, 25, 50, 100, 200, 250,500, 1000, 1250, 2500, 5000, 10 000 mV
@ 5 VDC excitation 0.5, 1, 2, 4, 5, 10, 20, 40, 50, 100, 200, 400, 500, 1000 mV/V
Input impedance >100MOhm
Input noise 3.5 nV * Hz
Typ. input offset drift 0.5 V/K (for ranges < 200 mV)
DC Accuracy High Gain without software correction table
2.5mV;5mV/V;10mV/V;25mV 0.03% of reading 15V [3V/V @5VEXC] 0.15% of reading 15V [3V/V @5VEXC]
20mV 0.03% of reading 0.08% of range 0.15% of reading 0.08% of range
50mV 0.03% of reading 0.05% of range 0.15% of reading 0.05% of range
100mV to 200mV 0.03% of reading 0.03% of range 0.15% of reading 0.03% of range
0.250 to 1V Low Gain 0.03% of reading 400V [80V/V @5VEXC] 0.15% of reading 400V [80V/V @5VEXC]
1.25V; 2.5V 0.03% of reading 1mV 0.15% of reading 1mV
5;10V 0.02% of reading 0.03% of range 0.15% of reading 0.03% of range
Gain drift @ 5 VDC excitation 10 ppm/K of range 0.02 V/V/K
Excitation voltage 0 to 12 V programable in 1 mV steps. ( 5 V default )
Excitation accuracy 0.05 % 0.7 mV
Excitation drift 10 ppm/K 50 V/K
Excitation protection continuous short to ground
Excitation current limit 50 mA/Channel
Bridge Types 4- or 6-wire full bridge
3- or 5-wire bridge with internal completion (software programmable)
3- wire Quarter bridge with internal 120 Ohm and 350 Ohm completion (software programmable)
Shunt Resistor Internal 100 k and 50 k Resistor (software programable)
Completion and Shunt resistor accuracy 0.05% 5ppm/K
Bridge resistance 120 Ohm to 10 k Ohm
Automatic bridge balance
1)
absolute Voltage mV/V @ 5V EXC m/m @ 5VEXC k=2 Quater bridge
2.5mV to 20mV 10mV 2mV/V 4000m/m
25mV to 200mV 100mV 20mV/V 40000m/m
250mV to 1V 0.5V 100mV/V 200,000m/m
2V to 10V 5V 1000mV/V 2,000,000m/m
Bandwidth (-3 dB) 30 kHz
Filters (lowpass) in combination with MDAQ-FILT-xx
Typ. SNR @ 30 kHz [1 kHz] 64 dB [82 dB] @ 1 mV/V
and 5 VDC excitation 82 dB [96 dB] @ 50 mV/V
Typ. CMR @ 0.1 mV/V [1 mV/V] 125 dB [120 dB] @ DC
and 5 VDC excitation 115 dB [110 dB] @ 400 Hz
110 dB [105 dB] @ 1 kHz
Max. common mode voltage range 12 V
Input overvoltage protection 25 VDC
Output voltage 5 V ( 10V with MDAQ-BASE-10)
Output resistance < 10 Ohm
Output current max. 5 mA
Output protection continuous short to ground
TEDS hardware support for TEDS (Transducer Electronic Data Sheet)
Supported TEDS chips DS2406, DS2430A, DS2432, DS2433
Power consumption
@ 5 VDC excitation 350 Ohm 16 Channels typ. 8 W
120 Ohm 16 Channels typ. 15 W
@ 10 VDC 350 Ohm 16 Channels typ. 15 W
Standard operating temperature 0 C to 70 C ( 32 F to 158 F)
1)
MDAQ-BASE-10A has the half offset adjustment range
MDAQ-SUB-STG-D combined with MDAQ-BASE-5
42
Internal signal processing
MDAQ-SUB-STG-D
6
1
2
7
4
8
9
3
10
G 1, G 50
G = (-1)
Sub+
Sub-
Sig Out
350 120 100k 50k 1k
1k
MDAQ-SUB-STG-D
PROG
EXC
Sense+
Exc+
In+
In-
GND
Exc-
Sense-
TEDS
Controller
TEDS
R+
MDAQ-BASE-x MDAQ-FILT-x
(optional)
Differential Amplifier
with Offset and
CMR control
43 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
V+
Sense+
R+
1)
IN+
Sense-
V-
IN-
Shield
1
6
5
2
3
8
7
4
9
-
p
in

S
U
B
-
D
TEDS
GND
9
4
TEDS
Data
GND
V+
Sense+
R+
1)
IN+
Sense-
V-
IN-
Shield
1
6
5
2
3
8
7
4
9
-
p
in

S
U
B
-
D
TEDS
GND
9
4
TEDS
Data
GND
Full bridge signal connection
6-wire sensor connection
(Sense wired at the sensor)
4-wire sensor connection
(Sense wired at the connector)
Sense leads (SUB-D: pin 3 and 6) have to be connected!
V+
Sense+
R+
1)
IN+
Sense-
V-
Shield
1
6
5
2
3
8
9
-
p
in

S
U
B
-
D
4
TEDS
GND
9
4
TEDS
Data
GND
V+
Sense+
R+
1)
IN+
Sense-
V-
Shield
1
6
5
2
3
8
4
9
-
p
in

S
U
B
-
D
TEDS
GND
9
4
TEDS
Data
GND
Half bridge signal connection
5-wire sensor connection
(Sense wired at the sensor)
3-wire sensor connection
(Sense wired at the connector)
Sense leads (SUB-D: pin 3 and 6) have to be connected!
V+
Sense+
R+
IN+
Sense-
V-
Shield
1
6
5
2
3
8
4
9
-
p
in

S
U
B
-
D
TEDS
GND
9
4
TEDS
Data
GND
Quarter bridge signal connection
3-wire sensor connection
(Sense wired at the connector)
Sense leads (SUB-D: pin 3 and 6) have to be connected!
1)
'R+' has to be connected only if shunt calibration is required, otherwise it can be left unconnected.
MDAQ-SUB-STG-D
44
Pin assignment of the input connectors
MDAQ-SUB-STG-D
1 EXC+
2 IN +
3 Sense
4 GND
5 R+
5 4 3 2 1
9 8 7 6
6 Sense+
7 IN -
8 EXC-
9 TEDS
If signals above 60 V may appear, dont use the metal housing of SUBD connector!
MDAQ-SUB-STG-D
45 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
E .. Bessel characteristics
U .. Butterworth characteristics
MDAQ-FILT-5-Bx
Filter board MDAQ-FILT-5-Bx
16 Channel 2
nd
order low pass flter
5 selectable flters including bypass function
5 different cut off frequencies
Discrete low noise flter design
Independent flter settings for each channel
Direct control from MDAQ-xx Amplifer series

Filter specifcations
MDAQ-FILT-5-Bx
Filter range (-3 dB)
standard 30 Hz, 100 Hz, 300 Hz, 1 kHz, 10 kHz, bypass
ordering option MDAQ-FILT-5-BU-S1 100 Hz, 1 kHz, 10 kHz, 30 kHz, 100 kHz, bypass
other frequencies on request
Bypass bandwidth > 700 kHz
Filter characteristics 2-Pole Bessel characteristic
2-Pole Butterworth characteristic
Attentuation slope 40 dB/decade (12 dB/octave)
Filter accuracy 1.5 dB @ f
c
DC gain 1 (0 dB)
Offset Error max. 1 mV (typ <0.2 mV)
max 0.01% of range with MDAQ-BASE-10
max 0.02% of range with MDAQ-BASE-5
Input voltage range 10 V
PP
Channel separation @ 50 kHz > 96 dB
Input configuration Single ended, designed for use with
MDAQ-V; MDAQ-BASE-5 and MDAQ-BASE-10
Output configuration Single ended
SNR @ bandwidth > 100 dB
Output impedance 5 Ohm
Output current max 20 mA
Output connector 68-pin Amplimite series (AMP Nr. 174339-6), SCSI II Type
Power supply 7.5 V to 15 V direct via MDAQ-BASE or -V
Power consumption typ. 3 W
Dimensions (W x D x H) 175 x 61 x 14 mm (6.9 x 2.4 x 0.9 in.)
46
MDAQ-FILT-5-Bx
Step response of 100 Hz flter

1.2
1
0.8
0.6
0.4
0.2
0
0 20 40 60 80 100
Butterworth 2-pole
Bessel 2-Pole
ms
Output connector
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
NC.
NC.
CH. 15+
GND
NC.
NC.
CH. 14+
CH. 13+
CH. 12+
CH. 11+
CH. 10+
CH. 9+
CH. 8+
CH. 7+
CH. 6+
CH. 5+
CH. 4+
CH. 3+
CH. 2+
CH. 1+
CH. 0+
NC.
NC.
NC.
NC.
NC.
NC.
GND
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
RS-485 A
RS-485 B
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
Input connector
(same pin assignment
for the output connector)
47 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Filter board MDAQ-FILT-10 option
16 channel 2
nd
order low pass flter board
Wide flter range from 10 Hz to 300 kHz
10 different cut off frequencies
Butterworth or Bessel characteristic
Independent flter settings for each channel
Direct control from MDAQ-xx amplifer series

Filter specifcations
MDAQ-FILT-10-xx
Filters (-3 dB)
standard 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz
10 kHz, 30 kHz, 100 kHz, 300 kHz (1.5 dB @ f0)
ordering option MDAQ-FILT-10-S1 10 Hz, 25 Hz, 35 Hz, 50 Hz, 100 Hz, 250 Hz,
350 Hz, 500 Hz, 1 kHz, 300 kHz (1.5 dB @ f0)
Filter characteristics
1)
Bessel or Butterworth (software programmable)
Attentuation slope 40 dB / decade (12 dB / octave)
DC gain 0 dB
Input voltage range
2)
10 V
PP
Channel separation @ 10 kHz > 96 dB
Input configuration Single ended
Input impedance > 100 MOhm parallel (2 kOhm + 470 pF)
Input connector 68-pin Amplimite series (AMP Nr. 174339-6)
Input protection 15 V
Offset error max 2 mV (typ <0.5 mV)
max 0.02 % of range MDAQ-BASE-10
max 0.04 % of range MDAQ-BASE-5
Output configuration Single ended
SNR @ full Bandwidth > 100 dB
Output impedance 5 Ohm
Output current 20 mA
Output connector 68-pin Amplimite series (AMP Nr. 174339-6); SCSI II Type
Control interface directly controlled by MDAQ-BASE or MDAQ-V
Power supply 7.5 V to 15 V
Power consumption typ. 3 W
Dimensions (W x D x H) 175 x 61 x 22 mm (6.9 x 2.4 x 0.9 in.)
(1)
300 kHz exclusively for Bessel characteristic
(2)
Power supply have to be 3 V higher than signal voltage range
MDAQ-FILT-10-xx
48
Connection
1 Filter input
Linear
regulator
Linear
regulator
Unregulated
supply
input
Regulated
supply
input
5
5
6
6
Power supply concept

2 Programming interface
3 Unregulated supply input
4 Regulated supply input
5 Voltage range selection for
unregulated voltage supply
open: 9 V
DC

short: 12.5 V
DC

6 Power supply selection
open: use regulated supply input
short: use unregulated supply input
7 Filter output

1 2 3 4 5 6 5 6 7
DGND
+5 V
SDA
SCL
Unregulated +
GND
Unregulated -
Regulated +
GND
Regulated -

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
NC.
NC.
CH. 15+
GND
NC.
NC.
CH. 14+
CH. 13+
CH. 12+
CH. 11+
CH. 10+
CH. 9+
CH. 8+
CH. 7+
CH. 6+
CH. 5+
CH. 4+
CH. 3+
CH. 2+
CH. 1+
CH. 0+
NC.
NC.
NC.
NC.
NC.
NC.
GND
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
RS-485 A
RS-485 B
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
NC.
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
Input connector
(same pin assignment
for the output connector)
The RS-485 pins are only to loop in the interface from the DEWE-ORION-1624 card to the MDAQ-INT-x
Module. The MDAQ-FILT-10 is controlled directly from the MDAQ-INT-x Module.
MDAQ-FILT-10-xx
49 DE-M080402E DEWE-MDAQ series Technical Reference Manual Printing version 1.0.0 April 16, 2008
Filter board MDAQ-AAF4-5-BU
16 Channel 4
th
order low pass flter
5 selectable flters including bypass function
5 different cut off frequencies
Discrete low noise flter design

Filter specifcations
MDAQ-AAF4-5-BU
Filter range (-3 dB)
standard 100 Hz, 1 kHz, 10 kHz, 30 kHz, 100 kHz, bypass
ordering option S1 163 Hz, 500 Hz, 2.5 kHz, 10 kHz, bypass, bypass
ordering option S2 10 Hz, 100 Hz, 1 kHz, 10 kHz, 20 kHz, bypass
other frequencies on request
Bypass Bandwidth > 700 kHz
Filter characteristics ordering option BE: 4-Pole Bessel characteristic
ordering option BU: 4-Pole Butterworth characteristic
Attentuation slope 80 dB/decade (24 dB/octave)
Filter accuracy 1.5 dB @ f
0
DC gain 1 (0 dB)
Offset Error max. 1 mV (typ <0.2 mV)
max 0.01% of range with MDAQ-BASE-10
max 0.02% of range with MDAQ-BASE-5
Input voltage range
2)
10 V
PP
Channel separation @ 50 kHz > 96 dB
Input configuration Single ended; designed for use with
MDAQ-V; MDAQ-BASE-5 and MDAQ-BASE-10
Output configuration Single ended
SNR @ full Bandwidth > 100 dB
Output impedance 5 Ohm
Output current max 20 mA
Output connector 68-pin Amplimite series (AMP Nr. 174339-6), SCSI II Type
Power supply 7.5 V to 15 V direct via MDAQ-BASE or -V
Power consumption typ. 3 W
Dimensions (W x D x H) 175 x 61 x 25 mm (6.9 x 2.4 x 1 in.)
U .. Butterworth characteristics
MDAQ-AAF4-5-BU
50
Step response of 100 Hz flter
1.2
1
0.8
0.6
0.4
0.2
0
0 20 40 60 80 100
Butterworth 4
th
order
ms
Butterworth
- maximally fat in the pass band frequency response
- There is some overshoot in the time domain
- Butterworth rolls off faster than the Bessel flter
MDAQ-AAF4-5-BU