Cement Design Example for 9-5/8" casing (cement volumes, displacement

volumes, pressure at bump, etc.)



Relevant Data
Vertical exploration well.
Previous casing: 13 3/8in, 72 lbs/ft, N-80, BTC, set at 3724 ft Below Derick Floor (BDF).
12.1/4in hole drilled to 5102 ft BDF.
9.5/8in casing, 47 lbs/ft, N-80, VAM, run to 5 053 ft BDF and float collar at 4954 ft BDF (2
joints shoetrack).
Casing to be cemented with 15.8 ppg slurry.
Mixwater recipe: industrial water + 0.4 % w/w fluid loss control additive + 0.2 % w/w
friction reducer (dispersant) + 0.03 % v/v defoamer.
Surface lines capacity = 1.0 bbl.
Mud in use: CMS (CMC/Bentonite) mud, 10.4ppg.

Cement Volume Calculations
a) The relevant capacities are given in the following table:
SECTION CAPACITY(bbls/ft)
9.5/8in casing 0.0732
12.1/4in (gauge) hole / 9.5/8in casing annulus 0.0558
13.3/8in / 9.5/8in casing annulus 0.0581
b) The relevant cement slurry yields and water/cement ratios are given in the following table:
SLURRY GRADIENT (psi/ft) YIELD
(cu.ft/sk)
WATER / CEMENT RATIO (gal/sk)
0.822 1.15 5
c) If the open hole section is gauge, the annular capacity would be:
(5 053 ft - 3 724 ft) x 0.0558bbls/ft = 74 bbls.


Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

Assume an SHDT calliper log has been run, giving an integrated cement volume of 89 bbls. No
excess will be used over this volume.
d) The volume of the shoetrack is (approx.):
(5 053 ft - 4954 ft) x 0.0732bbls/ft = 7.2 bbls.
e) Add (c) and (d) for the total slurry volume required:
89 bbls + 7.2 bbls = 96 bbls = 539 cu.ft
f) Yield = 1.15 cu.ft/sk, so:
539 cu.ft 469 sx cement required
1.15 cu.ft/sk
Water / cement ratio = 5 gal/sk, so:
g) 469 sk x 5 gal/sk = 2 345 gal = 56 bbls mixwater required.
Displacement Calculation
9.5/8in casing capacity from cementing head (assumed to be at drillfloor level) to float collar is:
4 954 ft x 0.0732 bbls/ft = 363 bbls
After the top plug has been dropped, 5 bbls of water behind will be pumped.
So the total displacement volume, to be pumped with the rig pumps is:
363 bbls - 5 bbls = 358 bbls
Using 0.2013 bbls/stroke for 100 % efficiency of the mud pumps, this equals:
1 778 strokes at 100 % efficiency
1 823 strokes at 97.5 % efficiency
1867 strokes at 95 % efficiency
Shoetrack volume is 7.2 bbls = 36 strokes (at 100 % efficiency).
If 97.5 % is the calibrated efficiency of the mud pumps, not more than 1 823 strokes should be
pumped (plug should bump after 1 823 strokes). This is done to avoid over-displacement of the
cement in the case of leaking plugs; 1 840 strokes equals the theoretical displacement volume at
97.5 % volumetric efficiency of the mud pumps plus half the volume of the shoetrack.
Mixwater Preparation
A mixwater volume of 56 bbls is required. Prepare some excess (to allow for suction loss of the
mixwater tank, eventualities, etc.).
56 bbls = 0.119 bbls/sk
469 sk
The water / cement ratio = 0.119 bbls/sk, so 15 bbls mixwater is enough for excess
71 bbls = 597 sk
0.119 bbls/sk

0.4 % w/w fluid loss additive =
0.4 x 597 sk x 94 lbs/sk = 224 lbs
100

0.2 % w/w friction reducer =

0.2 x 597 sk x 94 lbs/sk = 112 lbs
100

The defoamer should be added to the industrial water before the other additives.
150 bbls mixwater
0.03 % v/v defoamer = 0 03 x 71 bbls = 0.02 bbls = 0.85 gal 1 gal
Spacers
In this case, we assume the programme specified the use of the standard spacers for production
casing: a 500 ft industrial water spacer followed by 500 ft mudflush and 500 ft scavenger slurry.
Calculate the volumes required for 500 ft spacers in the average (washed out) hole - 9.5/8in
casing annulus.
The total integrated cement volume was 89 bbls over (5 053 ft - 3 724 ft) = 1 329 ft.


Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

So the average annulus capacity is:

89 bbls = 0.07 bbls/ft
1 329 ft

500 ft spacer will require 500 ft x 0.07 bbls/ft = 35 bbls = 196 cu.ft
For a 0.522 psi/ft scavenger slurry, a yield of 5.1 cu.ft/sk and a water / cement ratio of 34.4 gal/sk
can be assumed, So for 196 cu.ft, we need:

196 bbls = 38.4 sk
5.1cu.ft/sk

and,
38.4 sk x 34.4 gal/sk = 1322 gal = 31.51 bbls
After the top plug has been dropped, 5 bbls water behind water will be pumped.
Reduction in Overbalance
It has to be checked if the minimum required overbalance is held on the formations during all
stages of the cementation. If we assume 639 ft column of spacers (worst case, in gauge hole),
the resulting maximum temporary reduction in overpressure can be calculated as follows:
FLUID GRADIENT (psi/ft)
Mud 0.539
Preflush 0.460
Scavenger 0.522
639 ft x (0.539 - 0.460) psi/ft = 51 psi
639 ft x (0.539 - 0.522) psi/ft = 11. psi
Total reduction in overpressure = 122 psi
Hydrostatic Bump Pressure and Estimated TOC
An estimation of the position of the TOC can be obtained by observing the pump pressure just
before bumping the plug at a predetermined, slow rate and comparing this to the pump pressure
observed when circulating mud around at the same rate.
Hydrostatic bump pressure is defined as the standpipe pressure that would be seen at surface,
just before bumping, at no rate. It can be calculated before the job to predict what sort of bump
pressure can be expected.
In our case (TOC at 3 215 ft - 500 ft inside 13.3/8in shoe):
a) outside the casing:
cement : (5 053 ft - 3 215 ft) x 0.822 psi/ft = 1 510 psi
spacers: all spacers will be inside the 13.3/8in - 9.5/8in annulus at the moment of bumping.
31.5 bbls spacer means

31.5 bbls = 5 421 ft length spacer
0.0581 bbls/ft

5 421 ft x 0.460 psi/ft (mudflush) = 249 psi
5 421 ft x 0.522 psi/ft (scavenger) = 283 psi
Total = 532 psi
mud: above the spacers is 0.539 psi/ft mud. Prior to bumping, the top of the seawater spacer will
be at 1 589 ft.
1 589 ft x 0.539 psi/ft = 857 psi
So the total hydrostatic pressure at shoe depth, due to fluids outside the casing will be:
1 510 psi + 532 psi + 857 psi = 2 899 psi
b) inside the casing:
shoetrack: (5 053 ft - 4 954 ft) x 0.822 psi = 81 psi


Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

mud: prior to bumping, the top of the 31.5 bbls seawater spacer will be at 1 589 ft.
(4 954 ft ) x 0.541 psi/ft = 2 680 psi
So the total hydrostatic pressure at shoe depth, due to fluids inside the casing will be:
81 psi + 2 680 psi = 2 761 psi
c) pressure differential and estimation of TOC.

The predicted hydrostatic bump pressure will be:
2 899 psi - 2 761psi = 138 psi
Imagine that the observed pump pressure when circulating mud at 30 strokes per minute was 200
psi, while the observed bump pressure at this rate was 638 psi.
638 psi means a hydrostatic Bump Pressure of
638 psi - 200 psi = 438 psi
This is 438 psi - 138 psi = 300 psi higher than the predicted pressure.
Every foot of extra cement column will cause an additional pressure of (0.822 psi/ft - 0.541 psi/ft =
0.281 psi/ft.

300 psi = 1 068 ft
0.281 psi/ft

So the estimated TOC will be 1 068 ft higher than planned:

3 215 ft - 1 068 ft - = 2 147 ft BDF.

The expected differential pressure for various TOCs can be plotted on a graph, to get an idea of
the position of the cement slurry at any time during the displacement.


Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

This topic will demonstrate you how to figure out if the casing will be
hydraulically lifted while pumping cement.

Example:
Casing 9-5/8, 40 ppf (pound per foot), ID of casing = 8.835
Casing is set at 3,200MD/3,000TVD
Top of cement at 600MD/550TVD
Previous casing shoe (13-3/8) = 1000MD/900TVD
Cement weight = 14.0 ppg
Mud weight = 9.5 ppg
Displacement fluid weight (Brine) = 8.4 ppg

What is the condition at the static condition after cement in place?
What is the maximum pressure that we can apply before the casing is hydraulically pumped out
of the well?









Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

Under a static condition


Forces downward are Weight of casing and Wdf + Weight of displacement fluid.
Force upward is force due to hydrostatic pressure in the annulus.


Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)


The equation is showed below:

F = (Wc+Wdf) (HPann x A)

Where:
Wc = Weight of casing
Wdf = Weight of displacement fluid
HPann = Hydrostatic Pressure in the annulus
A = Cross section area of casing
We can put the numbers into these equations like this.
Wc = 40 x 3200 = 128,000 lb
Wdf = Hydrostatic pressure x Internal area of casing
Wdf = (0.052 x 8.4 x 3000) x (4 x (8.8352) = 80,335 lb
HPann = (0.052 x 9.5 x 550) + (0.052 x 14 x (3000-550)) = 2,055 psi
HPann x A = 2,055 x (4 x (9.6252) = 149,521 lb

F = (128,000 + 80,335) 149,521 = 58,814 lb

There is NO problem under static condition because downward force is more that upward
force.

Under a dynamic condition



Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

While pumping, the hydraulic pressure will force upward therefore the equation will be like this

We still use the same concept but this time we must add a force term generated by pumping
pressure (Ppump x a). This is the equation.
F = (Wc+Wdf) (HPann x A + Ppump x a)


Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

Where:
Wc = Weight of casing
Wdf = Weight of displacement fluid
HPann = Hydrostatic Pressure in the annulus
a = Cross section area of inside of casing
Ppump = pumping pressure
A = cross sectiona area of casing

We can determine the maximum pumping pressure before the casing will be lifted by substituting
F to 0.
When F = 0, the casing is about to be hydraulically lifted out of the wellbore so you can write the
new equation in new term like this:

0 = (Wc+Wdf) (HPann x A + Ppump x a)
Ppump x a = (Wc+Wdf) (HPann x A )
Ppump = [(Wc+Wdf) - (HPann x A )] a
Ppump from this relationship is maximum pumping pressure.

From the previous calculation, you already have the following figure:

Wc = 128,000 lb
Wdf = 80,335 lb
HPann x A = 149,521 lb
Ppump x (4 x (8.835)) = (128,000 + 80,335) 149,521



Cement Design Example for 9-5/8" casing (cement volumes, displacement
volumes, pressure at bump, etc.)

Ppump = 959 psi

Conclusion

What is the condition at the static condition after cement in place?
No movement
What is the maximum pressure that we can apply before the casing is hydraulically pumped out
of the well?
The maximum pressure that you can have while pumping is 959 psi.