1/14/14 how to configure s7-300 and s7.1200 communication through Profibus if I have CM1242-5 module?
- Siemens Industry Online Support - Technical Forum (m
https://www.automation.siemens.com/WW/forum/guests/PostShow.aspx?HTTPS=REDIR&PostID=348410&language=en 1/2 Page 1 of 1 (3 items) Inf orm Moderators Reply Quote Top Inf orm Moderators Reply Quote Top Print document Technical Forum Decentral Peripherie how to configure s7-300 and s7.1200 communication through Profibus if I have CM1242-5 module? Thread Starter: kolma46 Started: 3/9/2012 12:10 PM Replies: 2 Previous thread Next thread Enable Notification 3/9/2012, 12:10 PM kolma46 Joined 12/16/2010 Last visit: 11/16/2012 Posts: 1 Rating: (0) (0) Rate Thank Hello! how to configure s7-300 and s7.1200 communication through Profibus if I have CM1242-5 module? So in my case 313C-2DP will be master and CP1242-5 slave. IS there any example for 300<-->1200 communication?
Thanks, Andrej === Edited by O_Moderator @ 3/12/2012 10:42 AM [GMT ] === new subject after splitting from Config and Programming S7 - 1200 communicate with S7-300 by Profibus Network === Edited by kolma46 @ 3/9/2012 12:12 PM [GMT ] === Private message 3/9/2012, 2:29 PM UMENCHO Joined 3/21/2006 Last visit: 1/13/2014 Posts: 9561 Rating: (1011) (0) Rate Thank Hello, I think fo rthe moment that kind of sample project doen't exist here. Basically you need a GSD file for CM1242-5Download GSD File CM 1242-5 .There you can find an info S7-1200 Profibus communicaion Best regards, Hristo Mihalev Private message 1/14/14 how to configure s7-300 and s7.1200 communication through Profibus if I have CM1242-5 module? - Siemens Industry Online Support - Technical Forum (m https://www.automation.siemens.com/WW/forum/guests/PostShow.aspx?HTTPS=REDIR&PostID=348410&language=en 2/2 Inf orm Moderators Reply Quote Top Page 1 of 1 (3 items) 12/15/2012, 2:43 PM Milosh Joined 8/16/2010 Last visit: 1/13/2014 Posts: 297 Rating: (0) (0) Rate Thank I have similar problem. And I found the solution. In hw config of s7-300,: 1: added gsd for CM-1242 address 3 then added 16 byte input and 16 byte output 2. DP address 2 in hw confihg of CM in tia: 1. added subnet profibus_1 2. address of cm-1242 is 3 3. then added transfer area 1 16 byte output and transfer area 2 16 byte input Look at the order of byte in hw config. You need to provide reverse order of data to work properly. Best regarda, Milo Private message Thank you f or this post f rom: alex_zanella, dchartier Actions Copy Link To conference New post Si emens AG 2014 - Corporate Informati on - Pri vacy Pol i cy - Terms of Use