Type V-B, Any materials permitted (602.5) Windows(T-715.5) Door&Shutter(T-715.

3)
Structural frame 0 hours
a
Exterior bearing walls 0 hours
f
0 hours #N/A hours
Interior bearing walls 0 hours
Floor construction 0 hours
Roof construction 0 hours
Int. Non-bearing & partition NR
For Type V-B,Group R-3
Ext Wall Setback (ft) Fire Rating
Windows
(715.5)
Doors
(715.3)
hrs hrs hrs Unprotected Protected
North 5.1 1 10
a,c,e,g,h,i
25
a,c,e,g,h,i
1
South 4.5 1 NP
a,c,g
15
a,c,g
1
West 10 0 0 0 NL (g)
a,c,e,g,h,i
NL (g)
a,c,e,g,h,i
East 30 0 0 0 NL (g)
a,d,g,i
NL (g)
a,d,g,b
*For special requirements for Group U occupancies see Section 406.12
Between = hours, NS c, d b
1 hours, S
S = Buildings equipped throughout with an automatic sprinkler system installed in accordance withSection 903.3.1.1.
NS = Buildings not equipped throughout with an automatic sprinkler system installed in accordance withSection 903.3.1.1.
Occupancies Group 1
Type of construction 8
Required fire resistance rating 2 hours
fire resistance rating 1 hours
Type of Assembly Rating Minimum Opening Protection
7 2 hours
Location Section Nonspr Sprinkler Nonspr Sprinkler
1 302.1.1.1 Yes (1) Yes (1) No No
Group R-3
Occupancy Section
5
907.2.3
Exception:
Group R-3, An automatic sprinkler system shall be provided where:
Type of construction V-B Class C(c) Roof covering
C
C
C
Exit access corridors & other exitways
Room & enclosed space
c
C
Max area of opening in percentage of the
area of exterior wall.T-704.8
Fire-resistance rating requirements for exterior walls based on fire separation distance. (T-602)*
2
Fire-resistance rating requirement for building elements: (T-601)
C
Shaft enclosures (if required per 707.2)
Fire wall fire resistance rating, considered a separate building. (T-705.4 )
Opening protective fire rating for fire door and shutter assemblies (715.4)
Fire Damper
Interior wall and ceiling finish requirement by occupancy T-803.5
k
UNSPRINKLERED
C
Required Separation of Occupancies (T-508.3.3)*
SPRINKLERED
Smoke Damper
The required locations for fire and smoke dampers: (716.5)
Vertical exit & exit passageways
a b
Fire Alarm and Detection Systems (907)
System Type
Manual fire alarm system
Manual fire alarm boxes not required where six specific condition are met.
Minimum roof covering classification for type of construction T-1505.1
a b
&
CHAPTER 10
Floor Area Use
Occupancy
Group
Occupant
Loads
No of
Exit
1004.2.1
Area 1 5,000 240 gross 21 1
Area 2 500 35 net 15 2
Other 200
Total occupant load 36 1
2
Occupant Occupancy
Load Group Stair way Other Egress Stair way
0.3 0.2 0.2
15 5 (in) 3 (in) 3 (in)
Not required
For Group R-2
Without sprinkler system 200 feet
With sprinkler system 250 feet a,b
75 feet
125 feet, with sprinkler
For Group R-2
Without sprinkler system NP hrs
With sprinkler system hrs c
When occupant load served by corridor > 10
Occupancy Max story ht.
R-2 1 story
or 2 story
Travel Distance, Table 1015.1
10 occupants and 75 feet travel distance
4 dwelling units occupants and 50 feet travel
Common path of egress travel.1014.3
Max occupants (or dwelling units) per floor and
travel distance
Building with 1 exit, Section 1019.2
Corridor fire-resistance rating, Table 1017.1
Means of Egress,
Panic and fire exit hardware
Floor area per
occupant
T-1003.2.2.2
Egress width (Inches) per occupant served, Table 1005.1
Without sprinkler system With sprinkler system
No.of exits required
Other Egress
0.15
3 (in)
Required bath
or shower
Male: Female: Male: Female: Total: Total: Other
No. of
Occupants 1 per 75 1 per 75 1 per 200 1 per 200 1 per 500
100
1 1 1 1 1
Total Occupants = 100 1 1 1 1 1
MINIMUM NUMBER OF REQUIRED PLUMBING FACILITIES PER T-2902.1
1 Service sink
A-2
Restaurants, banquet halls and
food courts
Required water closet Required lavatories
Required drinking
fountain
Used
Group Description
Tributary area A
t
= SQ.FT
R
1
= Eq. 16-29
=
Rise per feet, F = 4 :12
R
2
= Eq. 16-31
=
L
r
= Eq. 16-24
=
Min Design Roof Load L
r
= psf
1607.9 REDUCTION OF LIVE LOAD
L = L
o
[0.25+15/(K
LL
A
T
)]
1/2
(6-24)
L
o
= psf T-1607.1
K
LL
= T-1607.9.1
A
T
= SQ.FT
L = psf = 0.59 L
o
L
o
= psf
R = r(A-150) (16-25)
A = SQ.FT
r = for floor
R = 60% Max for vertical member
L = psf
And R = 23.1(1+D/L
o
) (16-26)
Dead load D = psf
R = 60% Max for vertical member
L = psf
Min Design Live Load L = psf
Flat-roof snow load, p
f
= 0.7C
e
C
t
I
s
p
g
(7-1)
Ground snow load, p
g
= 100 psf Figure 7-1
Exposure of Roof =
Thermal Condition =
Snow load importance factor, I
s
= 1 Table 7-4
Snow exposure factor, C
e
= 0.7 Table 7-2
Thermal factor, C
t
= 1.1 Table 7-3
Flat-roof snow load, p
f
= 53.9 psf
Min p
f
= 20 psf 7.3
Design p
f
= 53.90 psf
p
s
= C
s
p
f
(7-2)
Design p
f
= 53.90 psf
Slope = 25
o
C
t
= 1.1
Slope factor C
s
= 0.75 7.4.1, 7.4.2, 7.4.3 Figure 7.2a,b and c
p
s
= 40.43 psf
W = 15.00ft
Balanced and Unbalanced Snow Load for Hip and Gable Roof
Snow Density = .13p
g
+ 14 30 pcf (7-3)
= 27.00 pcf
S =1/tan = 2.14 = 25
Height of Snow Drift h
d
= 1 ft
h
d
/S

= 18.44 psf
8
/
3
h
d
S

= 3.91 ft p
s
= 40.43ft
See Figure 7.3 for Curved Roof BALANCED
See Figure 7.4 for Cont Beam
See Figure 7-6 for Sawtooth Roof
p
s
= 100.00ft
See Figure 7-8 for Snow Drifts UNBALANCED W 20
3.91ft 18.44psf
UNBALANCED OTHER 12.13ft
40.43ft
7.4 SLOPE ROOF SNOW LOAD (slope > 5
o
)
1607.9.1 General
1607.9.2 Alternate Live Load reduction for
1607.11.2 MINIMUM ROOF LOAD
ASCE 7.3 FLAT ROOF SNOW LOAD (slope 5
o
)
1.00
20R
1
R
2
20(0.9)(1)
18.00
300.0
1.2-.001At
0.90
1.00
L shall not be less than 0.50 L
o
for members supporting one floor and L shall not be less than 0.40 L
o
for
members supporting two or more floors
40
1
2000.0
23.4
Terrain Category =
40
75.0
60.0
16.0
2000.0
0.08
60
16
16.0
IBC2006 (1613), ASCE 7-05 CHAPTER 11, 12, 13 SEISMIC DESIGN CRITERIA
Response Spectral Acc. (0.2 sec) S
s
= 25.00%g = 0.250g Figure 22-1 through 22-14
Response Spectral Acc.( 1.0 sec) S
1
= 15.00%g = 0.150g Figure 22-1 through 22-14
Soil Site Class Table 20-3-1, Default = D
Site Coefficient F
a
= 2.500 Table 11.4-1
Site Coefficient F
v
= 3.350 Table 11.4-2
Max Considered Earthquake Acc. S
MS
= F
a
.S
s = 0.625 (11.4-1)
Max Considered Earthquake Acc. S
M1
= F
v
.S
1 = 0.503 (11.4-2)
@ 5% Damped Design S
DS
= 2/3(S
MS
)
= 0.417 (11.4-3)
S
D1
= 2/3(S
M1
) = 0.335 (11.4-4)
Building Occupancy Categories Table 1-1
Design Category Consideration: or flexible with dist. between seismic resisting system <40ft
Seismic Design Category for 0.1sec C Table 11.6-1
Seismic Design Category for 1.0sec D Table 11.6-2
S1 < .75g NA Section 11.6
Since Ta .8Ts (see below), SDC = D Control (exception of Section 11.6 does not apply)
Comply with Seismic Design Category D IRC, Seismic Design Category = C
12.8 Equivalent lateral force procedure
Seismic Force Resisting Systems
C
t
= 0.02 x = 0.75 T-12.8-2
Building ht. H
n
= 330 ft Limited Building Height (ft) = NP
C
u
= 1.400 for S
D1
of 0.335g Table 12.8-1
Approx Fundamental period, T
a
= C
t
(h
n
)
x
= 1.549 12.8-7 T
L
= 8 sec
Calculated T shall not exceed Cu.Ta = 2.168 Use T = 1.549 sec.
0.8Ts = 0.8(S
D1
/S
DS) = 0.643
Is structure Regular & 5 stories ? 12.8.1.3
Response Spectral Acc.( 0.2 sec) S
s
= 0.250g
F
a
= 2.50
@ 5% Damped Design S
DS
= (F
a
.S
s
) = 0.417g (11.4-3)
Response Modification Coef. R = 5.5 Table-12.2-1
Over Strength Factor W
o
= 2.5
Importance factor I = 1 Table 11.5-1
Seismic Base Shear V = C
s
W
S
DS (12.8-2)
R/I
S
D1 (12.8-3)
(R/I).T
S
D1
T
L (12.8-4)
T
2
(R/I)
C
s
shall not be less than =
0.01 (12.8-5)
Min C
s
= 0.5S
1
I/R N/A For S
1
0.6g (12.8-6)
Use C
s
= 0.039
Design base shear V = 0.039 W Control
12.14 Simplified Seismic base shear
@ 5% Damped Design S
DS
= 0.417 SDC = D Limitations: P
F = 1.1 R = 5
V = FS
DS
(W) = 0.092 W
R
F
p
= 0.4a
p
S
DS
W
p
(1+2z/h) (13.3-1) S
DS
= 0.417
(R
p
/I
p
)
a
p
= 1 R
p
= 3 T-13.5-1 or 13.6-1
I
p
= 1.0 13.1.3
z = 10 ft h = 10 ft
F
p
=
0.167 Wp
Max F
p
= 1.6S
DS
I
p
W
p = 0.667Wp (13.3-2)
Min F
p
= 0.3S
DS
I
p
W
p = 0.125Wp (13.3-3)
F
p
=
0.167 Wp
F
p
= 0.40S
DS
IW
w 12.11.1
= 0.167(W)
or F
p
= 400S
DS
I = 167
shall be 280 #/ft
F
p
= 0.8S
DS
I(W
w
) (12.11.1)
= 0.333 Wp
Max Seismic Load E
M
= WQ
E
0.2S
DS
D (12.4.4), (12.4.5), (12.4,6), (12.4.7)
Where W
o
= 2.5
0.2S
DS
D = 0.084(D)
Deflection Amplification factor C
d
= 4.5
Nonbuilding structures, Section 15
Response Modification Coef. R = 3 T-15.4-1 or T-15.4-2
Importance factor I = 1 15.4.1.1
For flexible nonbuilding, C
s
= S
DS
I/R = 0.139
Min C
s
= 0.03 (15.4-1)
or C
s
= 0.8 S
1
I/R = 0.040 (15.4-2)
V = 0.139 W
For rigid nonbuilding, C
s
= 0.3 S
DS
I (15.4-5)
= 0.125 W
or need not to exceed, C
s
=
or C
s
=
E. DUAL SYSTEMS WITH INTERMEDIATE MOMENT FRAMES CAPABLE OF RESISTING AT LEAST
25% OF PRESCRIBED SEISMIC FORCES
< Ta
C
s
= =0.076
For T T
L
For T > T
L N/A
= 0.039
12.11.2 Anchorage of Concrete or Masonry structural Walls (flexible diaphragm)
12.11.1 Structural Walls and Their Anchorage
13.3 Seismic Demands on Nonstructural Components
For two-story building
T-12.14-1
T-12.2-1
T-R301.2.2.1.1
ASCE 7-05 (IBC 2006) WIND: BUILDING DATA:
Basic wind speed (3 sec gust) = 90 MPH
Exposure
Roof Pitch = 4.00 :12
Mean Roof Height h = 25 ft
Importance factor I
w
= 1.00 T-6-1
Height Adjustment factor = 1.00 Fig 6-2
-10.70G -7.97H -10.70G -6.80H
-15.40E -10.51F -15.40E -8.80F
-2.73D
-4.92B = 18.4
11.52C 8.50C H =27.4
17.27A All forces shown in psf 22.58333 12.80A
29 49
TRANSVERSE ELEV. LONGITUDINAL ELEV.
12.80A 2a= 6.0ft 10 % of least dimension= 2.9 ft
13.53 kips 40 % of the eave height = 9.0 ft
29 ft 6.77 k
10.1psf
4 % of least dimension or 3 ft= 3.0 ft
8.50C
9.3 psf
therefore a = 3.0 ft
49 ft
Example: p
s
= K
zt
Ip
s30
(6-1)
All forces shown in psf 6.0ft K
zt
= 1.00 6.5.7
horizontal load at end zone p
s30
= 12.8 Fig 6-2
11.52C 17.27A Height Adjustment factor = 1.00 Fig 6-2
PLAN VIEW Importance factor Iw = 1.00 6.2
FIGURE 6.2, Main Wind Force System 12.80psf
Roof
Angle
Wall (A) Roof (B) Wall (C ) Roof (D) WW (E) LW (F) WW (G) LW (H) E
OH
G
OH
Transverse 18.4 17.27 -4.92 11.52 -2.73 -15.40 -10.51 -10.70 -7.97 -21.60 -16.90
Longitudinal All 12.8 -6.7 8.5 -4 -15.4 -8.8 -10.7 -6.8 -21.6 -16.9
* If roof pressure under horizontal loads is less than zero, use zero
Plus and minus signs signify pressures acting toward and away from projected surfaces, respectively.
For the design of the longitudinal MWFRS use = 0, and locate the zone E/F, G/H boundary at the mid-length of the building
Roof effective area = 30 sq. ft, q= 18.4 Effective Area for wall element = 20 Sq. ft
Interior Zone 1 = 9.45 -12.87 psf Wall, Interior Zone 4 = 13.90 -15.10 psf
End Zone 2 = 9.45 -17.98 psf End Zone 5 = 13.90 -18.20 psf
Conner Zone 3 = 9.45 -23.90 psf
Roof Overhang effective area = 6 sq. ft
Interior Zone 2 = -26.13 psf
End Zone 3 = -36.71 psf
IBC 1605.2.1(LRFD) U = 0.9D + 1.6W
IBC 1605.3.1(ASD), U = 06D + W, increase in allowable shall not be used.
IBC 1605.3.2(ASD), U = D + 1.3 W, allowable stress are permit to be increased.
Load
Direction
Horizontal Loads Vertical Loads
MWFRS
End Zone Interior zone Overhang
6.4 METHOD 1- SIMPLIFIED PROCEDURE (LOW-RISE, 60 FT)
End Zone Interior zone
FIGURE 6-3, COMPONENT AND CLADDING
= =
X
X
x = 50
H = 80
= H/2
L
h
= 320
Height above local ground z = 45 ft
Hill Shape
Direction
Exposure B
Height of hill, H= 80 ft
Distance upwind of crest to where the
difference in ground elevation is half the
height of hill, L
h
= 320 ft
H/L
n
= 0.25
calculate K
1
by using H/L
n
= 0.25
Distance from the crest to the building, x = 50 ft x/L
h
= 0.16
Figure 6-4, K
1
/(H/L
h
) = 0.95 K
1
= 0.24
calculate K
2
, K
3
by using L
n
= 320
K
2
= 1 - x/L
h
= 1.5
K
2
= 0.90
K
3
= e
-z/L
h
= 4
K
3
= 0.57
K
zt
= [1 +K
1
K
2
K
3
]
2
(6-3)
K
zt
= 1.26
ASCE7-05, 6.5.7 Topographic Effects
6.5.14 Design Wind Load on Solid Freestanding Walls and Solid Signs Per ASCE 7-05
F = q
h
G C
f
A
s (6-27) B =20.00
q
z
= .00256 K
z
K
zt
K
d
V
2
I (6-15)
Exposure coefficient K
z
= Exposure 1.4
Topography factor K
zt
= 1.00 (6.5.7.2)
Directionality factor K
d
= 0.85 (6.5.4.4) 0 to s s to 2s
Wind Speed V= 90
Impotance factor I= 0.87 (6.5.5), T-6-1
q
z
= 15.33 K
z
Gust Effect factor G = 0.85 (6.5.8) L
1
= 0.00 ft D
1
= 1.00 ft Balance
B/s= 2.00
Cf =1.40
s/h = 1.00
Case A & B, C
f
= 1.40 Fig 6-20
Since B/s 2 Case C must also be considered
Total # of Segment with width = s Vert. location of resultant force L
2
= 0.00 ft D
2
= 1.50 ft
= 2 5.5 ft from grade
Balance, see Fig 6-20 = 0.00 ft
Case C, C
f
for Region
0 to s, = 2.25
s to 2s, = 1.50
L
3
= 0.00 ft D
3
= 2.00 ft
Case C, Multiples factor (if applicable)
Horizontal dim of return corner L
r
= 0.0 ft
when s/h > 0.8, (1.8-s/h) = 0.80 Free Standing Wall, Case C=
for Lr/s = 0.00, = 1.00 1 0.9
%openning = 0.0%
Reduction factor = 1.00
Method A & B
Sign h area A
s
C
f
K
z
q
h F (lbs) M (ft-lbs)
10.00 200.0 1.40 0.57 8.7 2080.2 11441.4
Pole 0.00 0.0 1.2 0.57 8.7 0.0 0.0
0.00 0.0 1.2 0.57 8.7 0.0 0.0 3.00ft
0.00 0.0 1.2 0.57 8.7 0.0 0.0
Total 2,080.2 11,441.4
H = 5.50 ft
Method C
Sign h area A
s
C
f
K
z
q
h F (lbs) M (ft-lbs) PSF
Balance, see Fig 6-20 = 10.00 0.00 1.40 0.57 8.7 0.0 0.0
0 to s, = 10.00 100.00 2.25 0.57 8.7 1337.3 6686.5 13.37
s to 2s, = 10.00 100.00 1.50 0.57 8.7 891.5 4457.7 8.92
0.57 8.7 0.0 0.0
0.57 8.7 0.0 0.0
0.57 8.7 0.0 0.0
0.57 8.7 0.0 0.0
0.57 8.7 0.0 0.0
Pole 0.00 0.0 1.2 0.57 8.7 0.0 0.0
0.00 0.0 1.2 0.57 8.7 0.0 0.0
0.00 0.0 1.2 0.57 8.7 0.0 0.0
Total 2,228.8 11,144.2
H = 5.00ft
IBC 1805.7: Design Employing Lateral Load Bearing
Total Lateral Load, P = 2080.2 lbs
Dist from ground to point of P, H = 5.50 ft
*Allowable lateral soil-bearing, S = 100.00 lbs/sq ft/ft
Allowable Increase = 2 x 100.00 lbs/sq ft/ft
Dia of footing or diagonal of sq. footing, b = 3.00 ft
Constrained at ground = No
S1 = 866 lbs/sq ft 15 x 100 O.K.
= 2.34P/S1 b
d = 0.5A[1+(1+(4.36h/A))]
d = 6.77 ft
Free Standing Wall, Case B=
11.14PSF
s = 10.00
Total h =10.00
d = 6.77 ft
10.40PSF
Design Requirement by Category Category A Category B Category C Category E Category F
Limit Building Height Table-12.2-1 NL NL NL NP NP NP
Seismic load effect E, 12.4 Q
E
0.2D
DS
D Q
E
0.2D
DS
D Q
E
0.2D
DS
D rQ
E
0.2S
DS
D rQ
E
0.2S
DS
D rQ
E
0.2S
DS
D
25 % Increase in Force for Connection
Horizontal Irregular 1a,1b,2,3 or 4 1a,1b,2,3 or 4 1a,1b,2,3 or 4
Vertical Irregular 4 4
Anchorage of concrete or masonry walls 0.40S
DS
IW
w
0.40S
DS
IW
w
0.40S
DS
IW
w
0.40S
DS
IW
w
0.40S
DS
IW
w
0.40S
DS
IW
w
400S
DS
I 400S
DS
I 400S
DS
I 400S
DS
I 400S
DS
I 400S
DS
I
Flexible 0.8S
DS
I
E
(W
w
) 0.8S
DS
I
E
(W
w
) 0.8S
DS
I
E
(W
w
) 0.8S
DS
I
E
(W
w
) 0.8S
DS
I
E
(W
w
)
Redundancy, r 1 1 1 1.3 1.3 1.3
Diaphragm, 12.10 max 0.4S
DS
Iw
px
0.4S
DS
Iw
px
0.4S
DS
Iw
px
0.4S
DS
Iw
px
0.4S
DS
Iw
px
0.4S
DS
Iw
px
min 0.2S
DS
Iw
px
0.2S
DS
Iw
px
0.2S
DS
Iw
px
0.2S
DS
Iw
px
0.2S
DS
Iw
px
0.2S
DS
Iw
px
Collector element & connection, 12.10.2
Q
E
Q
E
E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D
Light frame Q
E
Q
E
rQ
E
rQ
E
rQ
E
rQ
E
Structural Walls and Their
Anchorage, 12.11.1 .40I
E
S
DS
W
w
.40I
E
S
DS
W
w
.40I
E
S
DS
W
w
.40I
E
S
DS
W
w
.40I
E
S
DS
W
w
min 0.1W
w
0.1W
w
0.1W
w
0.1W
w
0.1W
w
Element Supporting discontinuous E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D E
m
=WQ
E
0.2S
DS
D
Wall and Frame, 12.3.3.3
Horizontal Irregular Not Permit na na na 1b 1b
Vertical Irregular Not Permit, 12.3.3.1 na na na 5b 1b, 5a or 5b 1b, 5a or 5b
Extrem Weak Stories 12.3.3.2 5b not over 2-story 5b not over 2-story 5b not over 2-story
Building Separations, 12.12.3 y y y y y y
Concrete
Seismic-force-resisting systems IBC 1908.1 IBC 1908.1.4 IBC 1908.1.4 IBC 1908.1.4
Discontinuous members. IBC 1908.1.12 IBC 1908.1.12 IBC 1908.1.12
Plain IBC 1910.4.4 IBC 1910.4.4 IBC 1910.4.4
Frame members not proportioned to resist forces
induced by earthquake motions. n/a n/a n/a IBC 1910.5.2 IBC 1910.5.2
Slab on Grade IBC1911.1 IBC1911.1 IBC1911.1 IBC1911.1
Masonry IBC 2106.3 IBC 2106.4 IBC 2106.6 IBC 2106.6
Seismic Design Requirement MSJC 1.14.3 MSJC 1.14.4 MSJC 1.15.5 MSJC 1.14.6 MSJC 1.14.7 MSJC 1.14.7
Wall not part of the lateral-force-resisting system IBC 2106.3.1 IBC 2106.3.1 IBC 2106.3.1 IBC 2106.3.1
Design of discontinuous members that are part of
the lateral-force-resisting system IBC 2106.4.1 IBC 2106.4.1 IBC 2106.4.1
1.5 times the forces IBC 2106.5.1 IBC 2106.5.1
Steel, AISC 341
Structural steel IBC 2205.2.1 IBC 2205.2.1 IBC 2205.2.1 IBC 2205.2.2 IBC 2205.2.2
Composite IBC 2205.3 IBC 2205.3.1 IBC 2205.3.1
Light frame IBC 2210.5 IBC 2210.5 IBC 2210.5 IBC 2210.5 IBC 2210.5
Wood
General IBC 2305 IBC2305 IBC2305 IBC2305 IBC2305 IBC2305
Shear wall 2305
Structural wood panel, h/d ratio, 2305.3.3 3
1
/
2
:1 3
1
/
2
:1 3
1
/
2
:1 2:1 2:1
Gypsum Board & Stucco 1
1
/
2
:1 1
1
/
2
:1 1
1
/
2
:1 NP NP
Particleboard 3
1
/
2
:1 3
1
/
2
:1 3
1
/
2
:1 NP NP
Fiberboard 1
1
/
2
:1 1
1
/
2
:1 1
1
/
2
:1 NP NP
Shear panel connections (2305.1.4) NA NA NA IBC 2305.1.4 IBC 2305.1.4 IBC 2305.1.4
Sill Plate IBC 2305.3.11 IBC 2305.3.11
MSJC = Masonry Standards Joint Committee (ACI 530.1-05/ASCE 6-05/TMS 602-05)
NP
NP
IBC 2305.3.11
1
1
/
2
:1
IBC 2205.2.2
IBC 2205.3.1
IBC 2210.5
2:1
IBC 2106.5
IBC 2106.3.1
IBC 2106.4.1
IBC 2106.5.1
IBC 1908.1.12
IBC 1910.4.4
IBC 1910.5.2
IBC1911.1
IBC 19081.4
na
Category D
.40IS
DS
W
w
0.1Ww
For: 8. Ordinary reinforced concrete shear walls, see 14.2
4
CONCRETE SLENDER WALL PER IBC-2006, ACI 318-05,Section 14.8 Ver 4/2006
Compressive strength, f'
c
= 4500 psi E = Q
E
0.2S
DS
D 12.4.2.3
Yield strength of rebars, f
y
= 60000 psi = Q
E
0.08 D
Wind Load, W = 14 psf Load Combination, IBC 1605.2.1
Seismic Load Q
E
= F
p
= 0.167 W
p U = 1.20 D + 1.6L (16-3)
Design response spectrum, S
DS
= 0.42 g U = 1.20 D + 0.5L + 1.6W (16-4)
Wall unsupported height, l
c
= 27 ft U = 1.28 D + 0.5L + 1.Q
E (16-5)
Parapet Height, p = 0 ft U = 0.90 D + 1.6W (16-6)
Eccentric, e = 2.7 in U = 0.82 D + 1.Q
E (16-7)
Design width, b = 24 in Concrete wt. = 150 pcf
Effective thickness, t = 6 in h/t = 54.0
Design, d = 3.8 in n = 7.1
Weight of the wall, W
p
= 75.0 psf E
c
=
Reduction factor, f =
0.9
1
= 0.825
Dead Load, D = 200 plf
Live Load, L = 100 plf
Vertical Rebars = # 5
Spacing = 24 in
Horizontal rebars = # 5
Spacing = 24 in
Wt. of the wall @ mid height P
w
= 2025 lbs Load Combination For Strength Design:
(16-3) (16-4) (16-5) (16-6) (16-7)
Factored load from trib Floor/Roof , P
uf
= 800.0 580.0 613.3 360.0 326.7 lbs
Factored weight of wall @ mid Ht, P
uw
= 2430.0 2430.0 2598.8 1822.5 1653.8 lbs
Factored axial load, P
u
= P
uf
+P
uw = 3230.0 3010.0 3212.1 2182.5 1980.4 lbs
Max P
u
/A
g
= 22.4 0.06f'c, OK, 14.8.2.6 = 22.4 20.9 22.3 15.2 13.8 psi
Factored distributed lateral load, w
u
= = 44.8 25.0 44.8 25.0 plf
A
s
= 0.310 sq.in 0.6r
b
(b.d) OK (14.8.2.3)
A
se
= (P
u
+A
s
.f
y
)/f
y = 0.36 0.36 0.36 0.35 0.34 sq.in
a = (P
u
+A
s
.f
y
)/(0.85.f'
c
.b) = 0.24 0.24 0.24 0.23 0.22 inch
c = a/0.85 = 0.28 0.28 0.28 0.27 0.26 inch

1
= (0.003/c)d - 0.003 = 0.038 0.038 0.038 0.040 0.040
0.005 for tension conctrol OK OK OK OK OK
Nominal strength, M
n
= (A
se
f
y
)(d - a/2) = 80,358 79,574 80,295 76,621 75,899 lb-in
I
cr
= n.A
se
.(d-c)
2
+bc
3
/3 (14-7) = 32.33 32.05 32.30 30.99 30.73
in
4
M
ua
= w
u
.l
c
2
/8+P
uf.
e
/
2
= 1,080 49,772 28,166 49,475 27,779 lb-in
M
u
= M
ua
+ P
u

u
(14-4) = 1,683 75,038 43,767 66,184 36,124 lb-in
D
u
= (5.M
u
.h
2
)/[.75(48.E
c
.I
cr
)] (14-5) = 0.19 8.39 4.86 7.66 4.21 in
Strength check fM
n
shall not be less than M
u
fM
n
= 72,323 71,617 72,265 68,959 68,309 lb-in
fMn > Mu (14-3) OK NG OK OK OK
Deflection at service load Load combination = (16-15)
Seismic Wind
Unfactored Load trib from floor/roof, P
f
= 600.0 600.0 lbs
P
w
= 2,025.0 2,025.0 lbs
P
s
= P
f
+ P
w 2,625.0 2,625.0 lbs
w = 17.5 28 plf
I
g
= b.t
3
/12
= 432 432
in
4
M
cr
= 7.5(f'
c
)
1/2
.I
g
)/0.5.t (9-9) = 72,449 72,449 lb-in > Mn, NG (14-2)
D
cr
= (5.M
cr
.h
2
)/(48.E
c
.I
c
) = 0.45 0.45 in
a = A
s
.f
y
/(0.85.f'
c
.b) = 0.20 0.20 in
c = a/0.85 = 0.24 0.24 in
I
cr
= n.A
s
.(d-c)
2
+bc
3
/3 (14-7) = 28.15 28.15
in
4
M = w.l
c
2
/8+P
f
.e/2+(P
s
).D
s (14-10) = 20,278 31,950 lb-in
I
e
= (M
cr
/M)
3
I
g
+ [1+(M
cr
/M)
3
]I
cr (9-8) = 432.0 432.0 I
g
in
4
D
s
= (5.M.l
c
2
)/(48.E
c
.I
e
) (14-9) = 0.13 0.20 inch
Allowable, D = l
c
/150 14.8.4 = 2.16 2.16 inch
Check total reinforcement OK OK `
Vertical reinforcement = 0.0022 A
g
Horizontal reinforcement = 0.0022 A
g
Total = 0.0043 A
g
M
u
obtained by iteration of
deflection
u
(10times)
D + L +(W or 0.7E)
4,066,840 psi
MASONRY SLENDER WALL PER IBC-2006, MSJC-05, SECTION 3.3.5 Ver 5/2003
Compressive strength, f'
m
= 1500 psi E = Q
E
0.2S
DS
D 12.4.2.3
Yield strength of rebars, f
y
= 60000 psi = Q
E
0.08 D
Wind Load, W = 5 psf Load Combination, IBC 1605.2.1
Seismic Load Q
E
=

F
p
= 0.224 W
p U = 1.20 D + 1.6L (16-3)
Design response spectral, S
DS
= 0.42 g U = 1.20 D + 0.5L + 1.6W (16-4)
Wall unsupported height, h = 35 ft U = 1.28 D + 0.5L + 1.Q
E
(16-5)
Parapet Height, p = 0 ft U = 0.90 D + 1.6W (16-6)
Eccentric, e = 7.3 in U = 0.82 D + 1.Q
E
(16-7)
Design width, b = 12 in
Effective thickness, t = 7.63 in h/t = 55.0
Design, d = 3.81 in n = 27.6
Weight of the wall, W
p
= 80 psf E
m
= 700 f'
m For clay masonry
Reduction factor, f = 0.9 MSJC 3.1.4.1 = MSJC 1.8.2
Tributary Dead Load, D = 50 plf f
r
= 84.0 psi, per T-3.1.8.2.1
Tributary Live Load, L = 0 plf
Vertical Rebars # 5
Spacing = 24 in
Horizontal rebars # 4
Spacing = 24 in
Wt. of the wall @ mid height P
w
= 1400 lbs Load Combination For Strength Design:
(16-3) (16-4) (16-5) (16-6) (16-7)
Factored load from trib Floor/Roof , P
uf
= 60.0 60.0 64.2 45.0 40.8 lbs
Factored weight of wall @ mid Ht, P
uw
= 1680.0 1680.0 1796.7 1260.0 1143.3 lbs
Factored axial load, P
u
= P
uw
+P
uf (3-25) 1740.0 1740.0 1860.8 1305.0 1184.2 lbs
Max P
u
/A
g
= 20.3 0.05 fm, OK (3-23), 3.3.5.4 19.0 19.0 20.3 14.3 12.9 psi
Factored distributed lateral load, w
u
= 8.0 17.9 8.0 17.9 plf
A
s
= 0.155 sq.in
A
se
= (P
u
+A
s
.f
y
)/f
y = 0.18 0.18 0.19 0.18 0.17 sq.in
a = (P
u
+A
s
.f
y
)/(0.8.f'
m
.b) (3-28) = 0.77 0.77 0.78 0.74 0.73 inch
c = a/0.8 3.3.2(g) = 0.96 0.96 0.97 0.92 0.91 inch
Nominal strength, M
n
= (A
s
f
y
+ P
u
)(d - a/2) (3-27) = 37,830 37,830 38,198 36,500 36,128 lb-in
I
cr
= n.A
se
.(d-c)
2
+bc
3
/3 = 44.85 44.85 45.11 43.88 43.60
in
4
Modulus of Rupture f
r
= 84.0 psi, per T-3.1.7.2.1 = 84 84 84 84 84 psi
I
g
= b.t
3
/12
= 444 444 444 444 444
in
4
M
cr
= (f
r
.I
g
)/0.5.t 3.3.5.4 = 9,780 9,780 9,780 9,780 9,780 lb-in

cr
= (5.M
cr
.h
2
)/(48.E
m
.I
g
) = 0.39 0.39 0.39 0.39 0.39 in
Applied ultimate strength, M
u
= w
u
.h
2
/8+P
uf.
e
/
2
+P
u
.
u
(3-24) = 235 27,479 93,068 21,413 55,023 lb-in
M
u
< M
cr
, d
u
= (5.M
u
.h
2
)/(48.E
m
.I
g
) = 0.01 N/A N/A N/A N/A inch
M
cr
< M
u
< M
n
, d
u
= d
cr
+ 5.(M
u
-M
cr
)h
2
/(48.E
m
.I
cr
) = N/A 7.22 32.19 5.02 18.53 inch
Strength check fM
n
shall not be less than M
u
fM
n
= 34,047 34,047 34,378 32,850 32,515 lb-in
fMn > Mu (3-26) OK OK NG OK NG
Deflection at service load Load combination = D + L + (W or 0.7E) (16-15)
Seismic Wind
Unfactored lateral load, w = 12.5 5.0 plf
Unfactored Load from trib floor/roof, P
f
= 50.0 50.0 lbs `
P
w
= 1,400.0 1,400.0 lbs
P = P
f
+P
w = 1,450.0 1,450.0 lbs
A
se
= (P+A
s
.f
y
)/f
y = 0.18 0.18
in
2
a = A
se
.f
y
/(0.8.f'
m
.b) = 0.75 0.75 in
c = a/0.8 = 0.93 0.93 in
I
cr
= n.A
se
.(d-c)
2
+bc
3
/3 = 44.20 44.20
in
4
M
s
= w.h
2
/8+P
f
.e/2+(P
f
+P
w
).d
s = 42,540 10,126 lb-in
M
s
< M
cr,
d
s
= (5.M
s
.h
2
)/(48.E
m
.I
g
) (3-30) = N/A N/A inch
M
cr
< M
s
< M
n
, d
s
= d
cr
+5.(M
s
-M
cr
)h
2
/(48.E
m
.I
cr
) (3-31) = 13.32 0.52 inch
Allowable, D = .007(h) (3-29) = 2.94 2.94 inch
Check total reinforcement NG OK
Vertical reinforcement = 0.0017 A
g
Horizontal reinforcement = 0.0011 A
g
Total = 0.0028 A
g
M
u
obtained by iteration of
deflection
u
(10times)
1,050,000 psi
Wood member Design: IBC
Design Live Load, L 20 Psf
Design Dead Load, D 10 Psf Deflection Limits L/ 360
Load Duration 1.25 (1 for Normal, 1.25 For Roof, 1.15 For Snow Loading)
Allow soil bearing= 1000 psf L.B with 2x Ledger
RAFTER / OR FLOOR JOIST (Table 1) HEADER (Table 2) Allowable load of L.B. in lbs 270 530
Size, Member Data Header Rafter/Floor joist
(ft) (Inch) Size Span(ft)*Overhang Ft - Inch 3/8"dia 5/8"Dia
# 12 14 13 6 875 40 0 8 6 6 13
# 16 12 12 3 95 41 0 8 5 6 12
2 19.2 12 11 7 1.6 42 0 8 4 6 12
1 24 11 10 9 1.2 F
b
875 43 0 8 3 6 12
# 12 18 18 2 CF 1.200 44 0 8 2 6 12
# 16 17 16 6 Cr 1.00 45 0 8 1 6 11
2 19.2 16 15 6 FOOTING (Table 3)
1 24 14 14 5 Rafter/Floor Joist Post Spacing
DF#2, Fb= 875 psi w/o Load Duration Span* Overhang 10 11 12 ft
CF= 1.3 Cr= 1.15 12.8 1.5 Int footing 240 19 20 21 Sq.In
For 2x6DF#2 Fb= 1309 psi Ext footing 240 14 14 15 Sq.In
Fv= 95 psi 13.8 1.5 Int footing 254 20 21 21 Sq.In
E= 1.6 psi Ext footing 254 14 15 15 Sq.In
For 4x10DF#2 Fb= 875 psi 14.8 1.5 Int footing 269 20 21 22 Sq.In
CF= 1.2 Cr= 1.00 Ext footing 269 14 15 16 Sq.In
Fv= 95 psi Patio may be supported on concrete slab, provided that the post
E= 1.6 psi do not support D+L in excess of 750 lbs.
R=Repetitive member Used (not more than 24" o/c)
S=Single member Used MINIMUM ROOF LIVE LOAD PER IBC 1607.11.2
Lag Bolts shall be min of 5" long Tributary area A
t
= SQ.FT
* For header with Rafter or Joist at both side, R
1
= Eq. 16-29
spacing (rafter's span) shall be double or average. =
Rise per feet, F = 5 :12
R
2
= Eq. 16-32
=
L
r
= Eq. 16-24
=
Min Design Roof L
r
= psf
1.2-.001At
0.90
1.2-.05F
17.10
0.95
20R
1
R
2
20(0.9)(0.95)
300.0
Spacing
(Inch)
Max Span Spacing(inch) Span
RAFTER SPAN
PER TABLE 1
LAG BOLT, SIZE &
SPACING PER TABLE 2
HEADER, PER TABLE 2
POST SPACING
PER TABLE 3
FOOTING SIZE
PER TABLE 3
HEADER, PER TABLE 2
Allowable load for plate, headed and bent bar anchor bolt per ACI 530-05, Section 2.1.4.2
Diameter of angle bolt = A
b
= 0.307
in
2
Edge distance l
be
= 15''
Equivalent embedment length, l
e
= 10''
f'
m
= 1,500 psi
f
y
= 36,000 psi
A
p
= l
e
2
= 314.29
in
2
(2-3, 2-4)
= 6086 lbs (2-1)
B
a
= 0.2A
b
f
y
= 2,210 lbs (2-2)
Allowable in tension, B
a
= 2210 lbs
= 1,621 (2-5)
Reduction factor = 1.00 B
v
= 1,621 lbs
or B
v
= 0.12A
b
f
y
= 1,326 lbs (2-6)
Allowable in shear B
v
= 1,326 lbs
Strength design for plate, headed and bent bar anchor bolt per ACI 530-05, Section 3.1.6
Diameter of angle bolt = A
b
= 0.307
Edge distance l
be
= 15''
Equivalent embedment length, l
b
= 10''
f'
m
= 1,500 psi
f
y
= 36,000 psi
A
pt
= l
b
2
= 314.29
fB
an
= .5(4A
pt
(f
'
m
)

) = 24,344 (3-1)
Or fB
an
= 0.9A
b
f
y
= 9,944 (3-2)
Capacity in tension fB
an
= 9,944 lbs
A
pv
= (l
be
2
) = 353.57 (3-10)
fB
vn
= .5(4A
pv
(f
'
m
)

) = 27,388 (3-8)
Or fB
vn
= 0.9(.6A
b
f
y
) = 5,967 (3-9)
Capacity in shear fB
vn
= 5,967 lbs
'
m p a
f A 5 . 0 B =
4
b
'
m v
A f 350 B =
Date Location Note
30-Apr-06 All Sheets
22-Jun-06 EQ
Revise cell C39, B43 to display C
s
value,
when T>T
L
Min Cs =0.01
8-Aug-06 Arch A-2, Sprinkler
Egress Common path of travel
7-Sep-06 CMU-Slender-wall Pu, 0.2fm & 0.05fm
12-Sep-06 EQ Max, Min F
p
12-Dec-06 Free standing sign Add wind load calc for sign
19-Dec-07 EQ Revise Limitation for T-12.14-1
Revise cell C41, S1 0.6g
ratany@yahoo.com Download the latest edition at
ratany@co.clark.nv.us http://seaoc.org/software.html
Fax: 702-380-9773
The application is created by Yo Ratanapeanchai, SE. This spreadsheet is intended as an
educational tool for learning and understanding of the IBC 2006 and ASCE 7-05. It will perform
both Fire Life Safety (chapter 3, 5, 6, 7, 8, 9, 10, 15 and 29) and Structural (Snow, Wind and
Earthquake Load, Chapter 16 and ASCE7-05) .The application is freeware, so feel free to
distribute, modify or use in anyway you see fit. Password protection is in place on some of the
Worksheets and will not be given due to data integrity of the original development. Report by fax or
email any errors or suggestions you may have. This will be greatly appreciated.
DISCLAIMER STATEMENT: The author is not responsible and liable for the accuracy of this
application and any information contained in this spreadsheet to the full extent permitted by the
law.
To verify the accuracy of the formula in each cell, just copy the entire Worksheet and paste or
follow each calculation process manually.
The built-in reset and print function are required for Macro to be set to Enable. See built in Help in
Excel for more information.
Last Update
12/19/2007