Você está na página 1de 2

CR MM3.

0 MAMMO CASSETTE
Easily identifiable CR cassettes for
dedicated mammography applications.
Compatible with the Agfa Mammography
CR Plates and Digitizers.
THE CR MM3.0 MAMMO CASSETTE IS
DESIGNED FOR USE IN COMBINATION WITH
THE CR MAMMO PLATE FOR DIAGNOSTIC
MAMMOGRAPHY APPLICATIONS. IT FEATURES
A NARROW HINGE TO ALLOW SCANNING RIGHT
UP THE CHEST WALL.
Two formats
The CR MM3.0 Mammo cassette is available in 18 x 24 cm
and 24 x 30 cm sizes. Having both allows the X-ray of
nearly any breast size.
A distinctive feature of the cassette design is its narrow
hinge. More of the breast tissue close to the chest
wall becomes thus available for scanning, offering an
increased amount of information during scanning.
Part of Agfa's CR Mammography system
CR MM3.0 Mammo cassette - combined with CR Mammo
plates - is part of Agfa's CR Mammography system.
Switching from conventional mammography is made
plain easy: only a re-calibration of the AEC of the existing
mammography X-ray unit is needed.
Unique design maximizes scanned tissue
close to the chest wall
Compatible with existing mammography
X-ray units. Allows a perfect fit into a
standard bucky
AEC compatible
Computed Radiography
Material
Top: ABS (Acrylonitryl butadiene styrene)
Bottom: PC (Polycarbonate)
Corners: PUR (Polyurethane rubber)
Hinges: PP (Polypropylene)
Inner lining: white felt
Sizes
18 x 24 cm
24 x 30 cm
Identification
Embedded memory chip
Contactless RF identification
Weight
18 x 24 cm 505 gr with plate
24 x 30 cm 795 gr with plate
Minimum requirements
CR MM3.0 Mammo plate
Digitizer: CR 85-X, CR 75.0, CR 25.0
CR QS FOR MAMMOGRAPHY workstation
with CR MAMMOGRAPHY SOFTWARE
Standards
ISO 4090:2001
DIN 6832 part 1 nr. 2
ANSI/NAPM IT 1.49-1995
IEC 406 (draft 1995)
The CR MM3.0 Mammo Cassette used in the Mammography
application is only available outside the US and Canada.
TECHNICAL SPECIFICATIONS
The CR cassette family
The CR MM3.0 Mammo cassette offers all the advantages
of the Agfa CR cassettes:
No change in exposure routine
Embedded identification data
(including demographic and exam information)
Robust design
Antistatic inner lining
Error proof manipulation
Cassette identification and readout
The CR MM3.0 Mammo cassette is supplied with special
mammo labels and stickers. This allows for easy
identification and avoids confusion with other types
of cassettes. The cassettes are pre-initialized before
leaving the factory so that the digitizer will automatically
recognize the cassettes as Mammo cassettes. If for
some reason the cassette is not pre-initialized, the user
can easily carry out this operation on an ID-station,
initializing the cassette on-site.
Copyright 2006 Agfa-Gevaert N.V.
All rights reserved
Printed in Belgium
Published by Agfa-Gevaert N.V.
B-2640 Mortsel - Belgium
NGJAJ GB 00200605
Agfa, the Agfa rhombus, Point of Knowledge and See More. Do More are trademarks of
Agfa-Gevaert N.V., Belgium or its affiliates. All other trademarks are held by their respective
owners and are used in an editorial fashion with no intention of infringement.

The data in this publication are for illustration purposes only and do not necessarily represent
standards or specifications which must be met by Agfa. All information contained herein is
intended for guidance purposes only, and characteristics of the products described in this
publication can be changed at any time without notice.

Products may not be available for your local area. Please contact your local sales representative
for availability information.
Agfa diligently strives to provide as accurate information as possible, but shall not be responsible
for any typographical error.

Você também pode gostar