Você está na página 1de 14

GE Medical Systems Americas: 888-202-5528

P.O. Box 414, Milwaukee, Wisconsin 53201 U.S.A.


GE Ultrasound - Europe: +49-212-28020
P.O. Box 1105 60 D-42665 Solingen
GE Ultrasound - Asia: 65-291-8528
Singapore: 298 Tiong Bahru Road, #15-01/06
Tiong Bahru Plaza, Singapore 168730
Internet: http://www.gemedicalsystems.com
Rev4.0.1
October 13, 2010


LOGIQ P5 Premium
TruScan Imaging Technology


Product Description
User Interface
Operator Keyboard
The LOGIQ P5 Premium is a high
performance, highly mobile and easy to
use multipurpose color Doppler
Ultrasound imaging system designed for
Obstetrical, Gynecological, Cardiac,
Musculoskeletal, Vascular, Urological,
Small Parts, Superficial, Pediatric,
Neonatal, Transcranial, Abdominal and
other applications.
Keyboard Width: 43cm
Keyboard Height: 84cm
Alphanumeric Keyboard
Ergonomic Hard Key Operations
Indicator Lights Identify Activated Keys
Integrated Recording Keys for Remote
Control of Up to 2 Peripheral Devices
and DICOM Devices
8 TGC Pods, with Re-mapping
Functionality at Any Depth
System Architecture
Monitor
TruScan Architecture GEs
innovative, software-intensive platform
provides exceptional computational
power, image-manipulation capabilities,
real time 4D capabilities, workflow
flexibility and product upgradeability.
15 inch TFT LCD
Electrical Power
XGA Format:
- Display size: 1024 x 768 Voltage: 100-120Vac or 220-240Vac
- Recording area: 800 x 600 Frequency: 50/60 Hz
Adjustable Tilt/Swivel Power: Max. 750 VA with Built-in and
On-Board Peripherals Digital Brightness/Contrast Adjustment
TruAccess is the GE advanced, raw-data
processing technology that has helped
transform ultrasound imaging. By
accessing raw data, TruScan achieves
excellent image quality and ensures
exceptional image management
capabilities.
Maximum Thermal Output: 2200
BTU/hr.
System Overview
Console Design
Applications
3 Active Probe Ports
Abdominal
Integrated HDD (Capacity: 250GB)
Obstetrical
Integrated DVD-R/W Drive
SmartScan utilizes new advances in
operating algorithms and system
operations to aid in improving image
acquisition and patient throughput while
helping to increase diagnostic
confidence and exam consistency.
Gynecological
On-board Storage for Peripherals (Max
3 peripherals)
Cardiac
Musculoskeletal
Wheels
Vascular
- Wheel diameter: 12.5cm
Urological
- Integrated locking mechanism that
provides rolling lock and optional
caster swivel lock
Small Parts and Superficial
ComfortScan, our advanced user-
friendly designed software suite helps to
maximize productivity. It simplifies every
exam you perform.
Pediatric and Neonatal
Transcranial
Probe Holders, Removable for Cleaning
and Washing
Scanning Methods
Gel Holder, Removable for Cleaning
and Washing
Electronic Sector
General Specification
Electronic Convex
Air Filters, Easily Removable
Electronic Linear
Dimensions and Weight
Front Handle
Mechanical Volume Sweep
Height: 135/141 cm
Rear Handle (Option)
Transducer Types
Width: 43cm
Drawer (Option)
Sector Phased Array Depth: 64cm
Probe Cable Hanger (Option)
Convex Array Weight: approx. 75 kg (165 lb.)
Urology Probe Holder (Option)

LOGIQ P5 DOC0518685 Page 1 of 14
Simultaneous Capability
Urological Calcs Microconvex Array
- B/PW
Renal Calcs Linear Array
- B/CFM or PDI
Real-time Auto Doppler Calculations Doppler Pencil
- B/M
TruAccess, Raw Data Processing Bi-plane Microconvex Array
- B + CFM/M
MpegView Real time 4D volume probes
- Realtime Triplex Mode
Key Macro
(B + CFM or PDI/PW)
Operating Modes
Network Storage - B-Flow + PW (option)
B-Mode
Dual B (B/B) Auto Focus
M-Mode
- Dual B + CFM or PDI
Wide Field of View on convex
Crossbeam
Selectable Alternating Modes
Simultaneous Display on BE9CS probe
SRI - B/M
Quick Save
- B/PW Elastography (option)
B-Steer
- B + CFM/M
Anatomical M Mode (option)
Virtual Convex with X-Beam
- B + CFM (PDI)/PW
Color Flow Mode (CFM)
ED Report - 3D Mode
Power Doppler Imaging (PDI) with
Directional Map
- 3D Color Mode (option) Flexible Monitor Arm
- B/CW (option)
System Options
PW Doppler with High PRF
- B + CFM (PDI)/CW (option)
Auto IMT B-Flow (option)
Multi Image Split Screen
- Live and/or frozen Elastography Steered CW Doppler (option)
- B + B/CFM or PDI
TVI Dedicated CW Doppler (option)
- Independent CINE playback
Stress Echo Coded Contrast Imaging (option)
- Quad screen format
DICOM 3.0 Connectivity 3D/4D Volume Modes (option)
Zoom: Write/Read/Pan
ECG
System Standard Features Colorized Image
Coded Contrast Imaging
- Colorized B
Hard Disk partition of 50GB for image
storage
CW Doppler
- Colorized M
- Colorized PW Anatomical M-Mode
Without compression:
- Colorized CW (option)
LOGIQView
Raw DICOM: HDD capacity 33.000
images
Time line Display
B-Flow
Independent Dual B/PW Display
Easy 3D (Baby Face, Vascular)
DICOM: Display Formats:
Advanced 3D, with 3D Landscape
Top/ Bottom selectable format (Size:
1/2:1/2; 1/3:2/3; 2/3:1/3)
- Image Only: HDD capacity 71.000
images
Real time 4D
3
rd
. probe port
Side/Side selectable format
CINE Memory Frames (60 sec) (192MB)
>1000 depending on probe, imaging
depth, line density and field of view
3-Pedal Foot Switch, with
Programmable Functionality
(1/2:1/2; 1/3:2/3; 0:1)
Switchable after freeze
TVI Rear Handle
Real-time Triplex Mode at any Depth
and PRF
Stress Echo
Drawer
Elastography
Probe Cable Hanger
Automatic Optimization

Urology Probe Holder
- Auto Tissue Optimization: ATO

1-Pedal Foot Switch
- Auto Spectrum Optimization: ASO
Display Annotation
Remote Control Switch
- Auto Color Optimization: ACO 1
st
. Patient Name: First, Last, &
Middle name each store 27
characters. Up to 62 total characters
displayed.
PDF report conversion
Coded harmonic Imaging
Coded Excitation
Media & Peripheral Options
Virtual Convex
Integrated Mounting Kits and Remote
Controls Provided for
2
nd
. Patient ID: 31 characters. Up to
27 total characters displayed.
Patient Information Database
Image Archive on Hard Drive and DVD
- B/W Digital thermal printer
Age, Sex and Birth Date (optional)
Easy Backup for Media
- Color Digital thermal printer
Hospital Name: 23 characters.
Report Designer
- DVD Video Recorder
Date: 3 Types selectable
MM/DD/YY,
DD/MM/YY,
Vascular Calcs

Cardiac Calcs
Display Modes
OB Calcs
Live and Stored Display Format: Full
size and split screen - both w/
thumbnails. For Still and CINE
YY/MM/DD
Fetal Trending
Time: 2 types selectable
Multi Gestational Calcs
24 hours, 12 hours
Hip Dysplasia Calcs

LOGIQ P5 Page 2 of 14

Review Image Format: 4x4, and
"thumbnails". For Still and CINE
Gestational Age from
LMP/EDD/GA/BBT
Gynecological Calcs
General System Parameters
Display Format: Full size, 4x4, and
"thumbnails"
Probe Name
Gray Map names

Live image and stored image side-
by-side display
Probe Orientation
System Setup
Depth Scale Marker
Pre-programmable Categories
CD-R storage: 650, 700 MB
Lateral Scale Marker
User Programmable Preset
Capability
DVD storage: -R 4,7GB
Focal Zone Markers
Conversion to MPEG, JPEG, AVI
(SaveAs) and WMV (MPEGvue) file
formats
Image Depth
Factory Default Preset Data
Zoom Depth Languages: English, French, German,
Spanish, Italian, Portuguese, Russian,
Greek, Swedish, Danish, Dutch, Finnish,
Norwegian, Japanese, Chinese
B-Mode
Internal Hard Drive partition of
50GB for Image Storage
- Gain
- Dynamic Range
External USB 2.0 Hard Drive support
for Import, Export, DICOM Read, SaveAs
and MPEGVue
OB Report Format: 5 Types, Tokyo
Univ., Osaka Univ., USA, Europe, and
ASUM
- Imaging Frequency
- Edge Enhance
- Frame Averaging
USB 1.1 / 2.0 Memory Stick support
for SaveAs and MPEGVue
EFBW: 10 types, Japan, USA and
Europe (Tokyo Univ., Osaka Univ., Tokyo
Shinozuka, JSUM, German, Shephard,
Merz, Hadlock/Shephard, Williams,
Brenner)
- Gray Map
- ATO On/Off
Network Storage support for Import,
Export, DICOM Read, SaveAs, MPEGVue
M-Mode
- Gain

- Dynamic Range
Connectivity
348 Pre-defined Annotations and
User Programmable
Libraries/Annotations
- Time Scale
Ethernet network connection
Doppler Mode
RS-232 serial data output (need a
converter cable)
- Gain
Body Patterns: 140 human types
plus 14 animal types
- Angle
DICOM 3.0 (option)
- Sample Volume Depth and Width
- Verify
Customized Comment Home
Position
- Wall Filter
- Print
- Velocity and/or Frequency Scale
- Store
- Spectrum Inversion
- Modality Worklist
- Time Scale
Complete User Manual available on
board through Help (F1)
- Storage Commitment
- PRF
- Modality Performed Procedure
Step (MPPS)
- Doppler Frequency
User Manual and Service Manual are
included on CD with each system. A
printed Manual is available upon request.
Color Flow Mode
- Media Exchange
- Line Density
- Off network / mobile storage
queue
- Frame Averaging

- Packet Size
CINE Memory/Image Memory - Query/Retrieve; supported on
Centricity and other compatible
vendors
- Color Scale
CINE Memory: 192MB
- Color Velocity Range and Baseline
Dual Image CINE Display
- Color Threshold Marker
- Structured Reporting; compatible
with LOGIQworks
Quad Image CINE Display
- Color Gain
CINE Gauge and CINE Image
Number Display
- PDI
- Public SR Template
- Color Scale Inversion
- Media Store of SR
CINE Review Loop
- Color Doppler Frequency
- iLinq capability
CINE Review Speed: 20 steps (10, 20,
30, 40, 50, 60, 70, 80, 90, 100, 150, 200,
300, 400, 500, 600, 700, 800, 900,
1000%)
TGC Curve

Acoustic Frame Rate
Scanning Parameters
Cine Frame Number
VCR Counter
Selectable CINE Sequence for CINE
Review
Digital Beamformer VCR Status
2560 processing channels VCR Playback Counter
Measurements, Calculations and
Annotations on CINE Playback
Frame Rate: > 700 depending on Body Pattern
Application Name preset
Scrolling Timeline Memory
Displayed Imaging Depth: 0 30 cm Measurement Results
Cine Capture Function
Minimum Depth of Field: 0 2cm Operator Message
Displayed Acoustic Output (probe dependent)
Maximum Depth of Field: 0 30 cm - TIS: Thermal Index Soft Tissue
Image Storage
- TIC: Thermal Index Cranial (Bone) (probe dependent)
On-board database of patient
information from past exams
Transmission Focus - TIB: Thermal Index Bone
- MI: Mechanical Index
1 8 Focus Points Selectable (probe Storage Format: DICOM/Raw Data
% of Power output
DICOM Still Image Storage Size: and application dependent)
Biopsy Guide Line and/or Zone
- Gray Image: ~300K to ~1.3 MB
Focal Zone Position, B-Mode 16
Heart Rate
- Color Image: ~900K to 1.9 MB
steps, CFM 64 steps
Multiframe

LOGIQ P5 Page 3 of 14

Multi-Frequency/Wideband
Dynamic Range: 30 120 dB, 3 dB
step
Line Density: 5 steps Technology
Frequency Range 1 to 13MHz Line Density Zoom: 5 steps
256 Shades of Gray Edge Enhance: 6 steps Frame Average: 7 steps
Up to 197 db processing dynamic Gray Scale Map: 23 types PRF: 280 Hz 19600 Hz
Clear Map: 23 types Spatial Filter: 6 steps range
16,777,216 Hues of Color M Gain: 0 98 dB, 2 dB step Gain: 0 40 dB, 0.5 dB step
Adjustable Field of View (FOV) up to
170 degree depending on probe
Wall Filter:4 steps depend on
probe/application

Anatomical M-Mode
Image Reverse: Right/Left Scanning Size (FOV or Angle): probe
dependent
M-mode cursor adjustable at any
plane
Image Rotation: 4 steps
CF/PDI Vertical Size (mm) of ROI:
default pre-settable
Rotation: 0, 90, 180, 270
Can be activated from a CINE loop
from a live or stored image
CF/PDI Center Depth (mm) of ROI:
default pre-settable
B-Mode Available with Color Flow Mode
M & A capability
B/M Acoustic Output: 0 100%,
2% step
CF/PDI Frequency: Up to 3 steps,
depend on probe

PW/CW-Mode Image Reverse: On/Off
Color Map: 20 types depend on
application
Maximum and Minimum Velocity
Scales
B Color: 10 types
Thermal Index: TIC, TIS, TIB
Transparent: 5 steps
- Max: 10 m/sec
Softener: 4 steps
Color Threshold: 0 100 %, 5 % step
- Min: 5 cm/sec
Focus Number: 8 steps
Auto Line Density: On/Off pre-
settable
Gray Scale Map: 4 types
Focus Width: 3 types
Dynamic Range: 24 60, 4 dB step
Range Focus: On/Off
PW/CF Ratio: 1, 2, 4
Base Line: 5 95 %, 11 steps
Compression: 0.5 1.5, 0.1 step
Accumulation: 8 steps
SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12,
14, 16 mm
Line Density: 4 steps

Line Density Zoom: 4 steps
Power Doppler Imaging
Angle Correct: +/- 90, 1 step
Suppression: 6 steps
PDI Map: 13 types
Spectral Color: 6 types
Frame Average: 8 steps
CF/PDI Flash Suppression: 2 steps
PW Sweep Speed: 8 steps
Edge Enhance: 6 steps
CF/PDI Focus Depth: default pre-
settable for 0 100 % of ROI in depth,
10 % step
Invert: On/Off
Scanning Size (FOV or Angle):
probe dependent, see probe
specifications
M/PW Display Format: V-1/3B, V-
1/2B, V-2/3B, H-1/2B, H-1/4B, TL only
CF/PDI Acoustic Output: 0 100%,
10% step
Duplex: On/Off(PW only)
Gray Scale Map: 23 types
PW Acoustic Output: 0 100 %,
10 % step
CF/PDI Angle Steer: 0, +/- 20 Clear Map: 23 types
Packet Size: 5 16, dependent on
probe/application
Tint Map: 10 types Spectral Averaging: 4 steps
Time Resolution: 4 steps Gain: 0 98 dB, 2 dB step
Spatial Filter: 6 steps
PW/CF Ratio: 1, 2, 4 Dynamic Range: 30 120 dB, 3 dB
step
Frame Average: 7 steps
Rejection: 15 steps
PRF: 280 Hz 19600 Hz
Gain: 0 32 dB, 1 dB step
Depth: 1 30 cm, 1 cm step,
depend on probe.
Power Threshold: 0 100 %, 5 %
step
Wall Filter: 5 1500 Hz, 22 steps,
depend on probe/application
Rejection: 6 steps
Gain: 0 40 dB, 0.5 dB step
PW Angle Steer: 0, +/- 5, 10, 15, 20
Frequency: Up to 5 steps, depend
on probe
Wall Filter: 7 steps depend on
probe/application
PRF: 640 29800 Hz with PW, 50000
Hz with CW
CF/PDI Frequency: Up to 3 steps,
depend on probe
Sample Volume Depth: 29 steps
default pre-settable
Auto Line Density: On/Off pre-
settable
Auto Line Density: On/Off pre-
settable
CW-Mode (option) is Available on
the Following Probes
Steered Linear: +/- 15

Transparent: 5 steps
- 3S
Color Flow Mode
Invert: On/Off
- 5S
Base Line: 0 100 %, 10 % step
Accumulation: 8 steps
- 7S
Invert: On/Off
- 3Sp
CF/PDI Focus Depth: default pre-
settable for 0 100 % of ROI in depth,
10 % step
M-Mode - 5Sp
- P2D
Sweep Speed: 8 steps
- P6D
M Color: 10 types
CF/PDI Flash Suppression: 2 steps
M/PW Display Format: V-1/3B, V-
1/2B, V-2/3B, H-1/2B, H-1/4B, TL only
CF/PDI Acoustic Output: 0 100%,
10% step
Coded Harmonic Imaging
B/M Acoustic Output: 0 100 %, 2 %
step
Available on the Following Probes
CF/PDI Angle Steer: 0, +/- 20
- 3.5C
Packet Size: 5 16, dependent on
probe/application
Rejection: 6 steps
- 3.5CS

LOGIQ P5 Page 4 of 14

- 3CRF - T739 2 types, Available on 3.5C and 3.5CS
probes - 4C - I739
- 5CS - 3S 3 type, Available on 4C, 5CS probes
- E8C - 5S - Tissue Background Selection: 4
steps - E8CS - 7S
- 8C - 3Sp Time Trigger Scan: 0.3, & 0.5 10
sec, 0.5 sec step - ERB - 5Sp
- BE9CS - ERB - Linear Time Intensity Curve Analysis
- 3S - 4C Accumulation: 8 steps
SRI-HD - 5S - 5CS
- 7S - 4D3C-L The LOGIQ P5 is designed for
compatibility with commercially
available ultrasound contrast agents.
Because the availability of these agents
is subject to government regulation and
approval, product features intended for
use with these agents may not be
commercially marketed nor made
available before the contrast agent is
cleared for use. Contrast related product
features are enabled only on systems for
delivery to an authorized country or
region of use. GE Medical Systems
makes no claims concerning the safety
or effectiveness of contrast agents.
- 3Sp - 3CRF
- 5Sp
- 8L
Automatic Optimization
- 9L
Optimize B-Mode, B-Flow image to
improve contrast resolution.
- 11L
- i12L
Selectable amount of contrast
resolution improvement (low, medium,
high)
- i739
- T739
- 4D3C-L
Auto-TGC in B-Mode and Color
adjusts overall and axial gain
- 4DE7C
- 4D8C
Optimize Spectral Waveform
adjusts baseline, invert, PRF (on live
image), and angle correction
Softener: 4 steps
Line Density: 4 steps
Line Density Zoom: 4 steps
Algorithm works on focal zone/
number and depth changes
Suppression: 6 steps

Edge Enhance: 6 steps
Elastography Mode (option) Available on stored or live image
Gray Scale Map: 23 types
Available in B-Mode, B-Flow, PW
Doppler, Color
Elasto Acoustic Output: 0 100%
Clear Map: 23 types
Line Density
Tint Map: 10 types
Elasto Frequency
Gain: 0 98 dB, 2 dB step
Frame Average
B-Flow (option)
Dynamic Range: 30 120 dB, 3 dB
step
Axial Smoothing
Available on 8L, 9L, 10L, 11L, i739
and T739 Probes
Later Smoothing
Rejection: 6 steps
Window
Background: On/Off
Auto Line Density: On/Off pre-
settable
Frame Reject
Sensitivity/PRI: 14 steps
Noise Reject
Line Density: 4 steps
Frequency: Up to 5 steps, depend on
probe
Transparency Map
Edge Enhance: 6 steps
Color and Gray Map
Frame Average: 8 steps

Soft Compress
Gray Scale Map: 23 types
Coded Excitation
Hard Compress
Clear Map: 23 types
Available on the following probes
the Following Probes
Quality Graph : On/Off
Tint Map: 10 types
Available on the following Probes
Dynamic Range: 30 120 dB, 3 dB
step
- 11L 11L
- 12L
Rejection: 6 steps
- 8C

Gain: 0 98 dB, 2 dB step
- E8C
Auto IMT (option) Auto Line Density: On/Off pre-
settable
- E8CS
Automated measurement of the
intimae media thickness of common
carotid artery
- BE9CS
Accumulation: 8 steps
- ERB


Result window displayed on screen
Coded Contrast Imaging (option)
Virtual Convex

Coded Harmonic Angio: Available on
3.5C, 3.5CS, 4C and 5CSprobes
Provides a Convex Field of View for
Convex, Linear and Sector probes
TVI (option)
Myocardial Doppler Imaging with
color overlay on tissue image
- Tissue Background Selection: 4
steps
Available on the Following Probes
- 8L
Available on all sector probes TruAgent Detection: Available on
3.5C, 3.5CS, 4C and 5CS probes
- 9L
Tissue color overlay can be
removed to show just the 2D image,
still retaining the tissue velocity
information
- 10L
- 2 frequencies on 3.5C and 3.5CS, 1
on 4C and 5CS probes
- 11L
- 12L
Coded Phase Inversion:
- i12L

LOGIQ P5 Page 5 of 14

CrossBeam Anatomical M-mode: free
placement of M-mode generated from
the cursor independent from the axial
plane
Scalpel: 3D Cut tool
Display Format:
Provides Spatial Compounding
- Quad: A-/B-/C-Plane/3D
Available on the linear and convex
probes
- Dual: A-Plane/3D
Q-Analysis: Multiple Time -Motion
trace display from selected points in
the myocardium
- Single: 3D or A- or B- or C-Plane
- 3CRF

- 4C
- 5CS
Pre-Processing - 8C
- E8C
Write Zoom up to 8x
Stress Echo Package (option)
- E8CS
B/M-Mode
Advanced and flexible stress-echo
examination capabilities
- 8L
- Gain
- 9L
- TGC
Provides exercise and
pharmacological protocol templates
- 11L
- Acoustic Output
- I12L
- Transmission Focus Position
- 6 default templates
- I739
- Transmission Focus Number
Template editor for user
configuration of existing templates or
creation of new templates
- T739
- Transmission Focus Width
- BE9CS
- Imaging Frequency
- 4D3C-L
- Edge Enhancement
Reference scan display during
acquisition for stress level comparison
(dual screen)
- 4DE7C
- Line Density Control
- 4D8C
- Live Anatomical M-mode
- ERB

- Baseline level/Previous level
selectable

PW/CW-Mode
Provides 3, 5 or 7 angles for
Compounding on Linear probes, 3 or 5
angles on Convex probes
- Gain
Raw data continuous capture
- Dynamic Range
- Over 180 sec available
- Acoustic Output
Wall motion scoring (bulls-eye and
segmental)
Compatible with Side by Side
Display
- Doppler Frequency
- Velocity Scale (PRF)
Compatible with: Color mode,
Timeline mode, SRI-HD, Coded
Harmonic Imaging, Virtual Convex
- PW/CF Ratio
LOGIQView (option)
- Wall Filter
Available on all probes
- Time Resolution
Extended Field of View Imaging

- Sample Volume Gate for PW-
Mode
For use in B-Mode
SRI-HD
LOGIQView Status
High Definition Speckle Reduction
Imaging
Length
Auto detection of scan direction
Depth
Pre or post-process zoom up to 10X
Provides 6 levels of speckle
reduction
Color Flow Mode
Rotation
- CFM Gain
Auto best fit on monitor
Side by Side Display - CFM Velocity Scale (PRF)
Measurements in B-Mode
Compatible with ALL linear, convex
and sector transducers
- Acoustic Output
Up to 60 cm scan length
- CFM Frequency

Compatible with ALL scanning
mode
- Wall Filter
Easy 3D (option)
- Packet Size
Compatible with Side by Side
Display
- CFM Spatial Filter Colorize
- CFM Line Density
Threshold (Opacification)
- CFM Regression Filter
Render
Real Time 4D (option) - Accumulation
Texture
Acquisition Modes:
Gray Surface
Post-Processing w/ TruAccess (Raw
Data)
- Realtime 4D Bmode
Scalpel
- Static 3D Bmode
Auto Movie
Visualization Modes:
SRI-HD Selectable level of Speckle
Reduction Imaging
Undo
- 3D Rendering (diverse surface and
intensity projection modes) Reset
Max Read Zoom to 16x

- Sectional Planes (3 Section planes
perpendicular to each other)
B/M-Mode
Advanced 3D (option) - ATO (Auto Tissue Optimization)
Render Mode:
- Image Reverse
Acquisition of Color data
- Surface texture, Surface Smooth,
max-, min- and X-ray (average
intensity projection), Gradient,
Inversion, Glass Body, Mix Mode of
two render Modes
- Image Rotation
Automatic rendering
- Gray Map
3D Landscape technology
- Colorized B and M
3D Movie
- Gain
Main Mode
- Dynamic Range
Curved 3point Render start
- TGC

LOGIQ P5 Page 6 of 14

3D Movie
Heart Rate - Compression - TCD (Transverse Cerebellum
Diameter) - Rejection
- Frame Averaging - THD (Thorax Transverse Diameter)
General Doppler
- B Softener - TIB (Tibia Length)
Measurements/Calculations
- Suppression - ULNA (Ulna Length)
Velocity
- Sweep Speed for M-Mode Estimated Fetal Weight (EFW) by:
Time
- Anatomical M Mode - AC, BPD
A/B Ratio (Velocities / Frequency
Ratio
PW/CW-Mode - AC, BPD, FL
- ASO (Auto Spectral Optimization) - AC, BPD, FL, HC
PS (Peak Systole)
- Base Line Shift - AC, FL
ED (End Diastole)
- Gray Map - AC, FL, HC
PS/ED (PS/ED Ratio)
- Post Gain - AC, HC
ED/PS (ED/PS Ratio)
- Compression Calculations and Ratios
AT (Acceleration Time)
- Rejection - FL/BPD
ACCEL (Acceleration)
- Spectral Averaging - FL/AC
TAMAX (Time Averaged Maximum
Velocity
- Colorized D - FL/HC
- Display Format - HC/AC
Volume Flow (TAMEAN and Vessel
Area)
- Sweep Speed - CI (Cephalic Index)
Color Flow Mode - AFI (Amniotic Fluid Index)
Heart Rate
- ACO (Auto Color Optimization) Measurements / Calculations by:
Jeanty, Merz, Tokyo University, Mercer,
Hansmann, Erickson, Hill, Shephard,
Hadlock, Hohler, Campbell
PI (Pulsatility Index)
- Base Line Shift
RI (Resistivity Index)
- Color Map

- Post Gain
Real-time Doppler Auto
- Frame Averaging Fetal Graphical Trending
Measurements / Calculations
- CFM Display Threshold Growth Percentiles
PS (Peak Systole)
- Angle Correct (PW mode) Multi-Gestational Calculations (4)
ED (End Diastole)
- Quick Angle Correct (PW mode) Fetal Qualitative Description
(Anatomical survey)
MD (Minimum Diastole)
- Auto Angle Correct (PW mode)
PI (Pulsatility Index)
- Spectral Invert for Color and
Doppler
Fetal Environmental Description
(Biophysical profile)
RI (Resistivity Index)
AT (Acceleration Time)
3D reconstruction from a stored
CINE loop
Programmable OB Tables
ACC (Acceleration)
Over 20 selectable OB Calcs
PS/ED (PS/ED Ratio)
Anatomical M-Mode Expanded Worksheets
ED/PS (ED/PS Ratio)
Accumulation
HR (Heart Rate)
Cine Capture
GYN Measurements/Calculations
TAMAX (Time Averaged Maximum
Velocity)
Right Ovary Length, Width, Height
Physiological Input Panel (Option)
Left Ovary Length, Width, Height
PVAL (Peak Velocity Value)
Physiological Input
Uterus Length, Width, Height
Volume Flow (TAMEAN and Vessel
Area)
- ECG, 1 channel
Ovarian Volume
Dual R-Trigger
ENDO (Endometrial thickness)
Pre-settable ECG R Delay Time
Ovarian RI
OB Measurements/Calculations
Pre-settable ECG Position
Uterine RI
Gestational Age by:
Adjustable ECG Gain Control
Follicular measurements
- GS (Gestational Sac)
Automatic Heart Rate Display
Summary Reports
- CRL (Crown Rump Length)

- FL (Femur Length)
Measurements / Calculations Vascular
Measurements/Calculations
- BPD (Biparietal Diameter)

- AC (Abdominal Circumference)
General B-Mode SYS DCCA (Systolic Distal Common
Carotid Artery)
- HC (Head Circumference)
Depth & Distance
- APTD x TTD (Anterior/Posterior
Trunk Diameter by Transverse Trunk
Diameter)
DIAS DCCA (Diastolic Distal Common
Carotid Artery)
Circumference (Ellipse / Trace)
Area (Ellipse / Trace)
SYS MCCA (Systolic Mid Common
Carotid Artery)
Volume (Ellipsoid)
- LV (Length of Vertebra)
% Stenosis (Area or Diameter)
- FTA (Fetal Trunk Cross-sectional
Area)
DIAS MCCA (Diastolic Mid Common
Carotid Artery)
Angle between two lines

- HL (Humerus Length)
SYS PCCA (Systolic Proximal
Common Carotid Artery)
General M-Mode - BD (Binocular Distance)
M-Depth - FT (Foot Length)
DIAS PCCA (Diastolic Proximal
Common Carotid Artery)
Distance - OFD (Occipital Frontal Diameter)
Time - TAD (Transverse Abdominal
Diameter) Slope

LOGIQ P5 Page 7 of 14

SYS DICA (Systolic Distal Internal
Carotid Artery)
Pulmonic Valve Area (PV Planimetry) Left Ventricle Mass (LVPWd, LVPWs)
Pulmonic Valve Annulus Diameter (PV
Annulus Diam)
Left Ventricle Volume, Teichholz/Cubic
(LVIDd, LVI Ds)
DIAS DICA (Systolic Distal Internal
Carotid Artery)
Pulmonic Diameter (Pulmonic Diam) Left Ventricle Internal Diameter (LVIDd,
LVI Ds)
SYS MICA (Systolic Mid Internal
Carotid Artery)
Right Atrium
Right Atrium Diameter, Length (RAD
Ma)
Left Ventricle Length (LVLd, LVLs)
DIAS MICA (Diastolic Mid Internal
Carotid Artery) Left Ventricle Outflow Tract Diameter
(LVOT Diam)
SYS PICA (Systolic Proximal Internal
Carotid Artery)
Right Atrium Diameter, Width (RAD Mi)
Right Atrium Area (RAA) Left Ventricle Posterior Wall Thickness
(LVPWd, LVPWs)
DIAS PICA (Diastolic Proximal
Internal Carotid Artery)
Right Atrium Volume, Single Plane,
Method of Disk (RAAd) Left Ventricle Length (LV Major)
SYS DECA (Systolic Distal External
Carotid Artery)
Right Atrium Volume, Systolic, Single
Plane, Method of Disk (RAAs)
Left Ventricle Width (LV Minor)
Left Ventricle Outflow Tract Area (LVOT)
DIAS DECA (Diastolic Distal External
Carotid Artery) Right Ventricle Left Ventricle Area, Two Chamber/Four
Chamber/Short Axis (LVA (d), LVA (s))
SYS PECA (Systolic Proximal External
Carotid Artery)
Right Ventricle Outflow Tract Area
(RVOT Planimetry) Left Ventricle Endocardial Area, Width
(LVA (d), LVA(s))
DIAS PECA (Diastolic Proximal
External Carotid Artery)
Left Pulmonary Artery Area (LPA Area)
Right Pulmonary Artery Area (RPA Area) Left Ventricle Epicardial Area, Length
(LVAepi (d), LVAepi (s))
VERT (Systolic Vertebral Velocity)
Right Ventricle Internal Diameter
(RVIDd, RVIDs)
SUBCLAV (Systolic Subclavian
Velocity)
Left Ventricle Mass Index (LVPWd,
LVPWs) Right Ventricle Diameter, Length (RVD
Ma)
Summary Reports
Mean IMT Measurement Tools
Ejection Fraction, Teichholz/Cube
(LVIDd, LVIDs) Right Ventricle Diameter, Width (RVD
Mi) Left Ventricle Posterior Wall Fractional
Shortening (LVPWd, LVPWs)
Cardiac
Right Ventricle Wall Thickness (RVAWd,
RVAWs)
Measurements/Calculations
Left Ventricle Stroke Index,
Teichholz/Cube (LVIDd, LVIDs, and
Body Surface Area)
B-Mode Measurements
Right Ventricle Outflow Tract Diameter
(RVOT Diam)
Aorta
Aortic Root Diameter (Ao Root Diam)
Left Pulmonary Artery (LPA) Left Ventricle Fractional Shortening
(LVIDd, LVIDs)
Aortic Arch Diameter (Ao Arch Diam)
Main Pulmonary Artery (MPA)
Ascending Aortic Diameter (Ao Asc)
Right Pulmonary Artery (RPA) Left Ventricle Stroke Volume,
Teichholz/Cubic (LVIDd, LVIDs)
Descending Aortic Diameter (Ao Desc
Diam)
System
Interventricular Septum Thickness
(IVSd, IVSs)
Left Ventricle Stroke Index, Single Plane,
Two Chamber, Method of Disk (LVI Dd,
LVIDs, LVSd, LVSs)
Aorta Annulus Diameter (Ao Annulus
Diam)
Inferior Vena Cava
Aorta Isthmus (Ao Isthmus)
Pulmonary Artery Diameter (MPA) Left Ventricle Stroke Index, Single Plane,
Four Chamber, Method of Disk (LVI Dd,
LVIDs, LVSd, LVSs)
Aorta *** (Ao st junct)
Systemic Vein Diameter (Systemic
Diam)
Aortic Valve
Aortic Valve Cusp Separation (AV Cusp)
Patent Ductus Arterosis Diameter (PDA
Diam)
Left Ventricle Stroke Index, Bi-Plane,
Bullet, Method of Disk (LVAd, LVAs)
Aortic Valve Area Planimetry (AVA Pl
ani met ry)
Pericard Effusion (PEs) Interventricular Septum (IVS)
*** ( Trans AVA)
Patent Foramen Ovale Diameter (PFO
Diam)
Left Ventricle Internal Diameter (LVI D)
Left Atrium
Left Ventricle Posterior Wall Thickness
(LVPW)
Left Atrium Diameter (LA Diam)
Ventricular Septal Defect Diameter
(VSD Diam)
LA Length (LA Major)
Mitral Valve
LA W idth (LA Minor)
Interventricular Septum (IVS) Fractional
Shortening (IVSd, IVSs)
Mitral Valve Annulus Diameter (MV Ann
Diam)
Left Atrium Diameter to AoRoot
Diameter Ratio (LA/Ao Ratio)
Tricuspid Valve E-Point-to-Septum Separation (EPSS)
Left Atrium Area (LAA(d), LAA(s))
Tricuspid Valve Area (TV Panimetry) Mitral Valve Area by Pressure Half Time
(MVA By PHT)
Left Atrium Volume, Single Plane,
Method of Disk (LAEDV A2C, LAESV
A2C ) (LAEDV A4C, LAESV A4C)
Tricuspid Valve Annulus Diameter (TV
Annulus Diam) Mitral Valve Area Planimetry (MVA
Planimetry)
M-Mode Measurements Left Ventricle
Pulmonic Valve

LOGIQ P5 Page 8 of 14

Tricuspid Valve Aorta Left Ventricle Outflow Tract Peak
Pressure Gradient (VLOT Vmax) QRS complex to end of envelope (Q-to-
TV close)
Aortic Root Diameter (Ao Root Diam)
Aortic Valve Left Ventricle Outflow Tract Peak
Velocity (LVOT Vmax) Aortic Valve Diameter (AV Diam)
Doppler Mode Measurements Left Ventricle Outflow Tract Mean
Pressure Gradient (LVOT Trace)
Aortic Valve Cusp Separation (AV Cusp)
Aortic Valve Aortic Valve Ejection Time (LVET)
Left Atrium Left Ventricle Outflow Tract Mean
Velocity (LVOT Trace)
Aortic Insufficiency Mean Pressure
Gradient (AR Trace) Left Atrium Diameter to AoRoot
Diameter Ratio (LA/Ao Ratio) Left Ventricle Outflow Tract Mean
Square Root Velocity (LVOT Trace)
Aortic Insufficiency Peak Pressure
Gradient (AR Vmax) Left Atrium Diameter (LA Diam)
Left Ventricle Left Ventricle Outflow Tract Velocity
Time Integral (LVOT Trace)
Aortic Insufficiency End Diastole
Pressure Gradient (AR Trace) Left Ventricle Volume, Teichholz/Cubic
(LVIDd, LVI Ds) Left Ventricle Ejection Time (LVET) Aortic Insufficiency Mean Velocity (AR
Trace) Cardiac Output by Aortic Flow (AVA Pl
ani met ry, AV Trace)
Left Ventricle Internal Diameter (LVIDd,
LVI Ds) Aortic Insufficiency Mean Square Root
Velocity (AR Trace) Stroke Volume Index by Aortic Flow
(AVA Planimetry, AV Trace)
Left Ventricle Posterior Wall Thickness
(LVPWd, LVPWs) Aortic Insufficiency Velocity Time
Integral (AR Trace) Mitral Valve Left Ventricle Ejection Time (LVET)
Mitral Valve Regurgitant Flow
Acceleration (MR Trace)
Left Ventricle Pre-Ejection Period
(LVPEP)
Aortic Valve Mean Velocity (AV Trace)
Aortic Valve Mean Square Root Velocity
(AV Trace) Mitral Valve Regurgitant Mean Velocity
(MR Trace)
Interventricular Septum (IVS)
Left Ventricle Internal Diameter (LVI D) Aortic Valve Velocity Time Integral (AV
Trace) Mitral Regurgitant Mean Square Root
Velocity (MR Trace)
Left Ventricle Posterior Wall Thickness
(LVPW) Aortic Valve Mean Pressure Gradient
(AV Trace) Mitral Valve Mitral Regurgitant Mean Pressure
Gradient (MR Trace) E-Point-to-Septum Separation (EPSS) Aortic Valve Peak Pressure Gradient
(AR Vmax) Mitral Regurgitant Velocity Time
Integral (MR Trace)
Mitral Valve Leaflet Separation (D-E
Excursion) Aortic Insufficiency Peak Velocity (AR
Vmax) Mitral Valve Mean Velocity (MR Trace) Mitral Valve Anterior Leaflet Excursion
(D-E Excursion) Mitral Valve Mean Square Root Velocity
(MR Trace)
Aortic Insufficiency End-Diastolic
Velocity (AR Trace) Mitral Valve D-E Slope (D-E Slope)
Mitral Valve Velocity Time Integral (MR
Trace)
Mitral Valve E-F Slope (E-F Slope) Aortic Valve Peak Velocity (AV Vmax)
Pulmonic Valve Aortic Valve Peak Velocity at Point E
(AV Vmax) Mitral Valve Mean Pressure Gradient
(MR Trace)
QRS complex to end of envelope (Q-to-
PV close) Aorta Proximal Coarctation (Coarc Pre-
Duct) Right Ventricle Mitral Regurgitant Peak Pressure
Gradient (MR Vmax) Right Ventricle Internal Diameter
(RVIDd, RVIDs)
Aorta Distal Coarctation (Coarc Post-
Duct) Mitral Valve Peak Pressure Gradient
(MR Vmax) Right Ventricle Wall Thickness (RVAWd,
RVAWs)
Aortic Valve Insufficiency Pressure Half
Time (AR PHT) Mitral Regurgitant Peak Velocity (MR
Vmax) Right Ventricle Outflow Tract Diameter
(RVOT Diam)
Aortic Valve Flow Acceleration (AV
Trace) Mitral Valve Peak Velocity (MR Vmax)
Mitral Valve Velocity Peak A (MV A
Velocity)
Right Ventricle Ejection Time (RVET) Aortic Valve Pressure Half Time (AV
Trace) Right Ventricle Pre-Ejection Period
(RVPEP) Mitral Valve Velocity Peak E (MV E
Velocity)
Aortic Valve Acceleration Time (AV Acc
Ti me) Velocity Circumferential Fiber
Shortening (Vcf) Mitral Valve Area according to PHT (MV
PHT)
Aortic Valve Deceleration TIme (AV
Trace) System
Mitral Valve Flow Deceleration (MV
Trace)
Interventricular Septum Thickness
(IVSd, IVSs)
Aortic Valve Ejection Time (AVET)
Aortic Valve Acceleration to Ejection
Time Ratio (AV Acc Time, AVET) Mitral Valve Pressure Half Time (PV
PHT)
Pericard Effusion (PE(d))
Interventricular Septum (IVS) Fractional
Shortening (IVSd, IVSs)
Aortic Valve Area according to PHT
Left Ventricle Mitral Valve Flow Acceleration (MV

LOGIQ P5 Page 9 of 14

IsoVolumetric Contraction Time (IVCT) Trace)
Mitral Valve E-Peak to A-Peak Ratio (A-
C and D-E) (MV E/ARatio)
Mitral Valve Acceleration Time (MV Acc
Time)
Mitral Valve Deceleration Time (MV Dec
Time)
Mitral Valve Ejection Time ((MV Trace)
Mitral Valve A-Wave Duration (MV A
Dur)
Mitral Valve Time to Peak (MV Trace)
Mitral Valve Acceleration
Time/Deceleration Time Ratio
(MVAcc/Dec Time)
Stroke Volume Index by Mitral Flow
(MVA Planimetry, MVTrace)
Mitral Valve Area from Continuity
Equation (MVAPlanimetry, LVOT Vmax,
MV Vmax)
Pulmonic Valve
Pulmonic Insufficiency Peak Pressure
Gradient (PR Vmax)
Pulmonic Insufficiency End-Diastolic
Pressure Gradient (PRTrace)
Pulmonic Valve Peak Pressure Gradient
(PV Vmax)
Pulmonic End-Diastolic Pressure
Gradient (PR Trace)
Pulmonic Insufficiency Peak Velocity
(PR Vmax)
Pulmonic Insufficiency End-Diastolic
Velocity (Prend Vmax)
Pulmonic Valve Peak Velocity (PV
Vmax)
Pulmonic End-Diastolic Velocity (PV
Trace)
Pulmonary Artery Diastolic Pressure
(PV Trace)
Pulmonic Insufficiency Mean Pressure
Gradient (PR Trace)
Pulmonic Valve Mean Pressure
Gradient (PV Trace)
Pulmonic Insufficiency Mean Velocity
(PR Trace)
Pulmonic Insufficiency Mean Square
Root Velocity(PR Trace)
Pulmonic Insufficiency Velocity Time
Integral (PR Trace)
Pulmonic Valve Mean Velocity (PV
Trace)
Pulmonic Valve Mean Square Root
Velocity (PV Trace)
Pulmonic Valve Velocity Time Integral
(PV Trace)
Pulmonary Vein S/D Ratio (P Vein D, P
Vein S)
Pulmonic Insufficiency Pressure Half
Time (PR PHT)
Ventricular Septal Defect Peak
Pressure Gradient (VSD Vmax)
Pulmonic Valve Flow Acceleration (PV
Acc Time)
Pulmonic-to-Systemic Flow Ratio
(Qp/Qs)
Pulmonic Valve Acceleration Time (PV
Acc Time)
Tricuspid Valve Pulmonic Valve Ejection Time (PVET)
Tricuspid Regurgitant Peak Pressure
Gradient (TR Vmax)
Pulmonic Valve Pre-Ejection Period
(PVPEP)
Tricuspid Valve Peak Pressure Gradient
(TV Vmax)
QRS complex to end of envelope (Q-to-
PV close)
Tricuspid Regurgitant Peak Velocity (TR
Vmax)
Pulmonic Valve Acceleration to Ejection
TIme Ratio (PV Acc Time, PVET)
Tricuspid Valve Peak Velocity (TV Vmax) Pulmonic Valve Pre-Ejection to Ejection
Time Ratio (PVPEP, PVET) Tricuspid Valve Velocity Peak A (TV A
Velocity) Right Ventricle
Tricuspid Valve Velocity Peak E (TV E
Velocity)
Right Ventricle Outflow Tract Peak
Pressure Gradient (RVOT Vmax)
Tricuspid Regurgitant Mean Pressure
Gradient (TR Trace)
Right Ventricle Systolic Pressure (RVOT
Vmax)
Tricuspid Valve Mean Pressure
Gradient (TV Trace)
Right Ventricle Outflow Tract Peak
Velocity (RVOT Vmax)
Tricuspid Regurgitant Mean Velocity
(TR Trace)
Right Ventricle Diastolic Pressure (RVOT
Trace)
Tricuspid Regurgitant Mean Square
Root Velocity (TR Trace)
Right Ventricle Outflow Tract Velocity
Time Integral (RVOTTrace)
Tricuspid Regurgitant Velocity Time
Integral (TR Trace)
Right Ventricle Ejection Time (RV Trace)
Stroke Volume by Pulmonic Flow
(RVOTPlanimetry, RVOTTrace) Tricuspid Valve Mean Velocity (TV
Trace) Right Ventricle Stroke Volume Index by
Pulmonic Flow (RVOT Planimetry, RVOT
Trace)
Tricuspid Valve Mean Square Root
Velocity (TV Trace)
System Tricuspid Valve Velocity Time Integral
(TV Trace) Pulmonary Artery Peak Velocity (PV
Vmax) Tricuspid Valve Time to Peak (TV
Acc/Dec Time) Pulmonary Vein Velocity Peak A
(reverse) (P Vein A) Tricuspid Valve Ejection Time (TV
Acc/Dec Time) Pulmonary Vein Peak Velocity (P Vein D,
P Vein S) Tricuspid Valve A-Wave Duration (TV A
Dur) Systemic Vein Peak Velocity (PDA
Diastolic, PDA Systolic) QRS complex to end of envelope (Q-to-
TV close) Ventricular Septal Defect Peak Velocity
(VSD Vmax) Tricuspid Valve Pressure Half Time (TV
PHT) Atrial Septal Defect (ASD Diastolic, ASD
Systolic) Stroke Volume by Tricuspid Flow (TV
Planimetry, TV Trace) Pulmonary Artery Velocity Time
Integral (PV Trace) Tricuspid Valve E-Peak to A-Peak Ratio
(TV E/A Velocity) Systemic Vein Velocity Time Integral
(PDA Trace)
Color Flow Mode Measurements Pulmonary Vein A-Wave Duration (P
Vein A Dur) Aortic Valve
- Proximal Isovelocity Surface Area: IsoVolumetric Relaxation Time (IVRT)

LOGIQ P5 Page 10 of 14

- Applications: Abdomen, OB Gyn,
Urology, Vascular
Left Ventricle Stroke Volume, Single
Plane, Two Chamber/Four Chamber,
Method of Disk(Simpson) (LVIDd, LVIDs,
LVAd, LVAs)
Regurgitant Orifice Area (AR Radius)
- Proximal Isovelocity Surface Area:
Radius of Aliased Point (AR Radius) - Probe Band Width: 2.0 5.0 MHz
- Number of Element: 128 - Proximal Isovelocity Surface Area:
Regurgitant Flow (AR Trace) - Convex Radius: 38 mmR Left Ventricle Volume, Two
Chamber/Four Chamber, Area-Length
(LVAd, LVAs)
- FOV (Max): 68 - Proximal Isovelocity Surface Area:
Regurgitant Volume Flow (AR Trace) - Physical Foot Print: 48 x 11 mm
- B-mode Imaging Frequency: 2.0, 3.0,
4.0, 5.0 MHz
Ejection Fraction, Bi-Plane, Method of
Disk (LVAd, LVAs, 2CH, 4CH)
Proximal Isovelocity Surface Area:
Aliased Velocity (AR Vmax)
- Harmonic Frequency: 4, 5, 5.2, 5.5
MHz
Mitral Valve Left Ventricle Stroke Volume, Bi-Plane,
Method of Disk (LVAd, LVAs, 2CH, 4CH) Proximal Isovelocity Surface Area:
Regurgitant Orifice Area (MR Radius) - Doppler Frequency: 2.5, 3.3 MHz Left Ventricle Volume, Bi-Plane, Method
of Disk (LVAd, LVAs, 2CH, 4CH) - Biopsy Guide Available: Single Angle,
Reusable
Proximal Isovelocity Surface Area:
Radius of Aliased Point (MR Radius) Left Ventricle Stroke Index, Single Plane,
Two Chamber/Four Chamber, Area-
Length (LVSd, LVSs, and BSA)
Proximal Isovelocity Surface Area:
Regurgitant Flow (MR Trace)

3.5C Wide Band Convex Probe
- Applications: Abdomen, OB Gyn,
Urology, Vascular
Left Ventricle Volume, Single Plane,
Two Chamber/Four Chamber, Method
of Disk (LVAd, LVAs)
Proximal Isovelocity Surface Area:
Regurgitant Volume Flow (MR Trace)
- Probe Band Width: 2.0 5.0 MHz Proximal Isovelocity Surface Area:
Aliased Velocity (MR Vmax) - Number of Element: 128 Left Ventricle Volume, Apical View,
Long Axis, Method of Disk (LVAd, LVAs) - Convex Radius: 38 mmR
Combination Mode Measurements - FOV (Max): 68 Stroke Volume by Aortic Flow (AVA
Planimetry, AV Trace) - Physical Foot Print: 48 x 11 mm Aortic Valve
- B-mode Imaging Frequency: 2.0, 3.0,
4.0, 5.0 MHz
- Aortic Valve Area (Ao Root Diam,
LVOT Vmax, AV Vmax)
Mitral Valve
Stroke Volume by Mitral Flow (MVA
Planimetry, MV Trace) - Harmonic Frequency: 4, 5, 5.2, 5.5
MHz
- Aortic Valve Area by Continuity
Equation by Peak Velocity (Ao Root
Diam, LVOT Vmax, AV Vmax)
Cardiac Output by Mitral Flow (MVA
Planimetry, MV Trace, HR) - Doppler Frequency: 2.5, 3.3 MHz
- Biopsy Guide Available: Single Angle,
Reusable
Pulmonic Valve Stroke Volume by Aortic Flow (AVA Pl
ani met ry, AV Trace) Stroke Volume by Pulmonic Flow (PV
Planimetry, PV Trace)

Cardiac Output by Aortic Flow (AVA
Planimetry, AV Trace, HR)
4C Wide Band Convex Probe
Cardiac Output by Pulmonic Flow (PV
Planimetry, PV Trace, HR)
- Applications: Abdomen, OB Gyn,
Urology, Vascular
Aortic Valve Area by Continuity
Equation VTI (Ao Root Diam, LVOT
Vmax, AV Trace)
Tricuspid Valve
- Probe Band Width : 1.4 5 MHz
Cardiac Output by Tricuspid Flow (TV
Planimetry, TV Trace, HR)
- Number of Element: 128
Left Ventricle
- Convex Radius : 60 mmR

- FOV (Max) : 58 Cardiac Output, Teichholz/Cubic (LVIDd,
LVI Ds, HR)
Report Designer
- Physical Foot Print : 60 x 18 mm
On-board reporting package
automates report writing
- B-mode Imaging Frequency : 2.0,
Cardiac Output Two Chamber, Single
Plane, Area-Length/ Method of
Disk(Simpson) (LVAd, LVAs, HR)
- 3.0, 4.0, 5.0 MHz
Formats various exam results into a
report suitable for printing to a
windows printer or reviewing on a
standard PC
- Harmonic Frequency : 4.0, 5.0, 5.2,
- 5.5 MHz
Cardiac Output Four Chamber, Single
Plane, Area-Length/ Method of
Disk(Simpson) (LVAd, LVAs, HR)
- Doppler Frequency : 2.5, 3.3 MHz
- Biopsy Guide Available : Multi
Angle, Reusable
Exam results include patient info,
exam info, measurements, calculations,
images, comments and diagnosis

Ejection Fraction Two Chamber, Single
Plane, Area-Length/ Method of
Disk(Simpson) (LVAd, LVAs)
5CS Convex Probe
Standard templates provided
- Applications: Abdomen, OB Gyn,
Urology Customizable templates
Ejection Fraction Four Chamber, Single
Plane, Area-Length/ Method of
Disk(Simpson) (LVAd, LVAs)
- Probe Band Width : 2 6 MHz
- Number of Element : 128
- Convex Radius : 60 mmR
Probes
Left Ventricle Stroke Volume, Single
Plane, Two Chamber/Four Chamber,
Area-Length (LVAd, LVAs)
- FOV (Max) : 58
- Physical Foot Print : 60 x 18 mm
- B-mode Imaging Frequency : 2.0,
3.5CS Thin Wide Band Convex Probe

LOGIQ P5 Page 11 of 14

- 3.0, 4.0, 5.0 MHz
- 10.0, 12.0 MHz - Harmonic Frequency : 4.0, 5.0, 5.5, - Number of Element : 128
- Harmonic Frequency : 10.0, 12.0, - 6.0 MHz - Convex Radius : 9 mmR
- 13.0 MHz - Doppler Frequency : 2.5, 3.3 MHz - FOV (Max) : 170
- Doppler Frequency : 5.0, 6.7 MHz - Biopsy Guide Available : Multi
Angle, Reusable
- Physical Foot Print : 15 x 10 mm
- Steered Angle : 0, +/- 5, 10, 15, 20 - B-mode Imaging Frequency : 6.0,
- Biopsy Guide Available : Multi - 8.0, 10.0 MHz
- Angle, Reusable 8L Wide Band Linear Probe - Harmonic Frequency : 8.0, 10.0
MHz - Applications : Vascular, Small
- Doppler Frequency : 4.0, 5.0 MHz Parts
12L Wide Band Linear Probe
- Probe Band Width : 4 11MHz - Biopsy Guide Available : Single
- Applications: Small Parts, Vascular,
Neonatal, Pediatrics
- Number of Element : 128 - Angle, Disposable and Reusable
- FOV (Max) : 38 mm
- Probe Band Width: 5 13.0 MHz
- Physical Foot Print : 38 x 10 mm 8C Wide Band Microconvex Probe
- Number of Element: 192
- B-mode Imaging Frequency : 6.0, - Applications : Neonatal, Pediatrics
- FOV (Max): 39 mm
- 8.0, 10.0 MHz - Probe Band Width : 4 11 MHz
- Physical Foot Print: 45 x 10 mm - Harmonic Frequency : 8.0, 10.0, - Number of Element : 128
- 12.0 MHz - Convex Radius : 11 mmR
- B-mode Imaging Frequency: 7.0, 10.0,
12.0 MHz
- Doppler Frequency : 5.0, 6.7 MHz - FOV (Max) : 133
- Steered Angle : 0, +/- 5, 10, 15, 20 - Physical Foot Print : 26 x 10 mm
- Harmonic Frequency: 10.0, 12.0 MHz
- Biopsy Guide Available : Multi - B-mode Imaging Frequency : 6.0,
- Doppler Frequency: 5.0, 6.7 MHz
- 8.0, 10.0 MHz Angle, Reusable
- Steered Angle: +/- 10, 20
- Harmonic Frequency : 8.0, 10.0
Biopsy Guide Available: Single Angle,
Reusable
9L Wide Band Linear Probe MHz
- Applications: Vascular, Small Parts - Doppler Frequency : 4.0, 5.0 MHz

- Probe Band Width : 3 10 MHz - Biopsy Guide Available : None
3CRF Wide Band Microconvex Probe
- Number of Element : 192
- Applications: Abdomen, Urology,
Vascular
- FOV (Max) : 44 mm 3S Wide Band Phased Array Sector
- Physical Foot Print : 44 x 6 mm Probe
- Probe Band Width : 2.0 4 MHz
- B-mode Imaging Frequency : 5.0, - Applications : Cardiac, Trancranial,
- Number of Element: 128
- 7.0, 9.0 MHz Abdomen
- Convex Radius : 20 mmR
- Harmonic Frequency : 8.0, 10.0 - Probe Band Width : 1.5 3.5 MHz
- FOV (Max) : 80
- MHz - Number of Element : 64
- Physical Foot Print : 28 x 16 mm
- Doppler Frequency : 4.0, 5.0 MHz - FOV (Max) : 90
- B-mode Imaging Frequency : 2.0,
- Steered Angle : 0, +/- 5, 10, 15, 20 - Physical Foot Print : 19 x 16 mm
- 3.0, 3.5, 4.0 MHz
- Biopsy Guide Available : Multi - B-mode Imaging Frequency : 2.0,
- Harmonic Frequency : 3.6, 3.8, 4.0,
- Angle, Reusable - 2.5, 3.0 MHz
- 4.2MHz
- Harmonic Frequency : 2.8, 3.0, 3.2,
- Doppler Frequency : 2.5, 3.3 MHz
- 3.6 MHz
10L Wide Band Linear Probe
- Biopsy Guide Available : Single
Angle, Reusable
- Doppler Frequency : 1.7, 2.0, 2.2
- Applications: Vascular, Small Parts,
Neonatal, Pediatrics
- MHz

- CW Doppler Frequency : 2.0 MHz
- Probe Band Width: 4 11 MHz
E8C Wide Band Microconvex Probe
- Biopsy Guide Available : Multi
- Applications : OB Gyn, Urology,
Endocavity
- Number of Element: 192
- Angle, Reusable
- FOV (Max): 39 mm

- Probe Band Width : 4 11 MHz
- Physical Foot Print: 39 x 10 mm 5S Wide Band Phased Array Sector
- Number of Element : 128
Probe
- B-mode Imaging Frequency: 6.0, 8.0,
10.0 MHz
- Convex Radius : 11 mmR
- Applications : Cardiac, Trancranial,
- FOV (Max) : 133
Abdomen
- Doppler Frequency: 5.0, 6.7 MHz
- Physical Foot Print : 26 x 10 mm
- Probe Band Width : 2 5 MHz
- Steered Angle: +/- 10, 20
- B-mode Imaging Frequency : 6.0,
- Number of Element : 96
- Biopsy Guide Available: Multi Angle,
Reusable
- 8.0, 10.0 MHz
- FOV (Max) : 90
- Harmonic Frequency : 8.0, 10.0
- Physical Foot Print : 19 x 11 mm
- MHz
- B-mode Imaging Frequency : 3.0 ,
- Doppler Frequency : 4.0, 5.0 MHz
11L Wide Band Linear Probe
- 4.0, 5.0 MHz
- Biopsy Guide Available : Single
Angle, Disposable and Reusable
- Applications : Small Parts,
- Harmonic Frequency : 4.0, 5.0 MHz
Vascular, Neonatal, Pediatrics
- Doppler Frequency : 2.5, 3.3 MHz

- Probe Band Width : 5 13 MHz
- CW Doppler Frequency : 2.5 MHz
E8CS Wide Band Microconvex Probe
- Number of Element : 192
Biopsy Guide Available: Multi Angle,
Reusable
- Applications : OB Gyn, Urology,
- FOV (Max) : 38.4 mm
Endocavity
- Physical Foot Print : 38 x 10mm

- Probe Band Width : 4 11 MHz
- B-mode Imaging Frequency : 7.0,

LOGIQ P5 Page 12 of 14

7S Wide Band Phased Array Sector
Probe
- 8.0, 10.0 MHz ERB Convex: 5 - 9MHz
- Harmonic Frequency : 10.0, - Number of Element: 128
- 12.0MHz - FOV (Max) :
- Applications: Cardiac, Pediatrics,
Abdomen
- Doppler Frequency : 5.0, 6.7 MHz ERB Linear: 51mm
- Steered Angle : +/- 5, 10, 15, 20 ERB Convex: 123
- Probe Band Width : 3 8 MHz
- Biopsy Guide Available : None - Physical Foot Print:
- Number of Element : 96
ERB Linear: 51 x 5 mm
- FOV (Max) : 90
t739 Intraoperative Wide Band ERB Convex: 17 x 5.5 mm
- Physical Foot Print : 14 x 7 mm
- B-mode Imaging Frequency: 6.0, 8.0,
10.0 MHz
Linear Probe
- B-mode Imaging Frequency : 5.0,
- Applications : Intraoperative, Small
- 6.0, 7.0 MHz
- Harmonic Frequency: 8.0, 10.0 MHz Parts, Vascular, Pediatrics
- Harmonic Frequency : 6.0, 7.0, 8.0,
- Probe Band Width : 4 -10 MHz - Doppler Frequency: 5.0, 6.7 MHz
- 8.5 MHz
- Biopsy Guide Available: Multi
Angle, Grid Reusable
- Number of Element: 192
- Doppler Frequency : 4.0, 5.0 MHz
- FOV (Max) : 39 mm
- CW Doppler Frequency : 4.0 MHz
- Physical Foot Print : 39 x 10 mm
- Biopsy Guide Available : None
4D3C-L Convex Volume Probe - B-mode Imaging Frequency : 6.0,
- Applications : Abdomen, OB Gyn - 8.0, 10.0 MHz
3Sp Wide Band Phased Array Sector
- Probe Band Width : 2 5 MHz - Harmonic Frequency : 8.0, 10.0,
Probe
- Number of Element: 192 - 12.0 MHz
- Applications : Cardiac, Trancranial,
- Convex Radius : 39.1 mmR - Doppler Frequency : 5.0, 6.7 MHz
Abdomen
- Volume Sweep Radius: 19.8 mmR - Steered Angle : +/- 5, 10, 15, 20
- Probe Band Width : 1.5 5MHz
- FOV: 87 Volume 85 x 80 - Biopsy Guide Available : Multi
- Number of Element : 64
- Physical Foot Print : 60 x 13 mm - Angle, Reusable
- FOV (Max) : 90
- B-mode Imaging Frequency : 3.0,
- Physical Foot Print : 16 x 14 mm
- 4.0, 5.0 MHz i739 Intraoperative Wide Band
Linear Probe
- B-mode Imaging Frequency : 2.0,
- Harmonic Frequency : 4.0, 4.5, 4.8,
- 3.0, 4.0, 5.0 MHz
- .0 MHz - Applications : Intraoperative, Small
- Harmonic Frequency : 3.0, 3.5, 4.0,
- Doppler Frequency : 2.5, 3.3 MHz - Parts, Vascular, Pediatrics
- 5.0, 5.5 MHz
- Biopsy Guide Available : Single
Angle, Reusable (stainless steel,
plastic)
- Probe Band Width : 4 10 MHz
- Doppler Frequency : 1.8, 2.0, 2.5,
- Number of Element: 192
- 3.3, 4.0 MHz
- FOV (Max) : 39 mm
- CW Doppler Frequency : 2.0 MHz
- Physical Foot Print : 39 x 10 mm
Biopsy Guide Available: Multi Angle,
Reusable
4D8C Micro Convex Volume Probe - B-mode Imaging Frequency : 6.0,
- Applications : Neonatal, Pediatrics - 8.0, 10.0 MHz
- Harmonic Frequency : 8.0, 10.0, - Probe Band Width : 4 11 MHz 5Sp Wide Band Phased Array Sector
- 12.0 MHz - Number of Element: 192 Probe
- Doppler Frequency : 5.0, 6.7 MHz - Convex Radius : 14.0 mmR - Applications : Cardiac, Trancranial,
- Steered Angle : +/- 5, 10, 15, 20 - Volume Sweep Radius: 80 mm Abdomen
Biopsy Guide Available : None - FOV: 120 Volume 37.4 mm x 29 Probe Band Width : 2.0 8.0 MHz
- Physical Foot Print : 30 x 50 mm - Number of Element : 64
BE9CS Wide Band Biplane
Microconvex Probe
- B-mode Imaging Frequency : 6.0, - FOV (Max) : 90
- 8.0, 10.0 MHz - Physical Foot Print : 10 x 10 mm
- Applications: Urology, Endocavity - Harmonic Frequency : 8.0, 10.0, - B-mode Imaging Frequency : 4.0,
- Probe Band Width : 4 11MHz - 1.0 MHz - 5.0, 6.7, 8.0 MHz
- Number of Element : 96 x 2 - Doppler Frequency : 4.0, 5.0 MHz - Harmonic Frequency : 5.0, 6.0, 8.0,
- Convex Radius : 9 mmR - Biopsy Guide Available : Single
Angle Reusable(stainless steel, plastic)
- 10.0 MHz
- FOV (Max) : 127
- Doppler Frequency : 2.7, 3.0, 3.3
- Physical Foot Print : 20 x 10 mm - 4.0, 5.0 MHz
- B-mode Imaging Frequency : 6.0, 4DE7C Convex Volume Probe - CW Doppler Frequency : 2.5 MHz
- 8.0, 10.0 MHz - Applications : OB Gyn, Urology Biopsy Guide Available: Multi Angle,
Reusable
- Harmonic Frequency : 8.0, 10.0 - Probe Band Width : 4 11 MHz
- MHz - Number of Element: 192
- Doppler Frequency : 4.0, 5.0 MHz - Convex Radius: 10.1 mmR i12L Intraoperative Wide Band
Linear Probe
- Biopsy Guide Available : Single
Angle Reusable (stainless steel),
Disposable
- Volume Sweep Radius: 11.6 mmR
- FOV: 133 Volume 146 x 90 - Applications : Intraoperative, Small
- Physical Foot Print : 27 x 6 mm - Parts, Vascular, Pediatrics
- B-mode Imaging Frequency : 6.0, - Probe Band Width : 4 12 MHz
ERB Wide Band Biplane Probe - 8.0, 10.0 MHz - Number of Element : 96
- Harmonic Frequency : 8.0, 10.0, - Applications: Urology - FOV (Max) : 25 mm
- 11.0 MHz - Probe Band Width: - Physical Foot Print : 29 x 10 mm
- B-mode Imaging Frequency : 6.0, ERB Linear5 10 MHz

LOGIQ P5 Page 13 of 14

- Doppler Frequency : 4.0, 5.0 MHz
CE Marked to Council Directive
93/42/EEC on Medical Devices
- Biopsy Guide Available : Single
Angle, Reusable (stainless steel)

GE Ultraschall Deutschland GmbH & Co KG
Beethovenstr. 239, D-42655 Solingen
Conforms to the following standards
for safety:
Tel.: (+49) 212-2802-0
P2D Non-imaging Single CW
Fax: (+49) 212-2802-28
-IEC/EN 60601-1 Medical Electrical
equipment, General requirement for
Safety
Doppler Pencil Probe

- Applications : Cardiac
Internet : www.gehealthcare.com
- Frequency: 2.0 MHz


-IEC/EN 60601-1-1 Safety
requirements for Medical Electrical
Systems

P6D Non-imaging Single CW
GE, GE Monogram and LOGIQ, CrossXBeam ,
TruScan , LOGIQView and Inte are trademarks
of General Electric Company.
Doppler Pencil Probe
- Applications : Cardiac, Vascular,
Pediatric
-IEC/EN 60601-1-2 Electromagnetic
compatibility

- Frequency: 5.0 MHz
GE Medical Systems Ultrasound & Primary
Care Diagnostics, LLC a General Electric
company doing business as GE Healthcare
-IEC/EN 60601-1-4 Programmable
medical systems UG7C Gastro Probe Europe Only
- Applications Transesophageal,
-IEC/EN 60601-2-37 Particular
requirements for the safety of
ultrasonic medical diagnostic and
monitoring equipment

Stomach

- Probe Band Width : 4.5 10MHz

- Number of Element: 128

- Convex Radius: 8.5 mmR
-IEC 61157 Declaration of acoustic
output
- FOV (Max) : 125
- Physical Foot Print : 19 x 5 mm
- B-mode Imaging Frequency : 6.0, -ISO 10993 Biological evaluation of
medical devices
- 8.0, 10.0 MHz
- Harmonic Frequency : 8.0, 10.0
NEMA UD3 Acoustic output display (MI,
TIS, TIB, TIC)
- MHz
- Doppler Frequency : 5.0, 6.7 MHz

- Biopsy Guide Available: None

* available only in Europe
2008 General Electric Company - All rights reserved.

Inputs and Outputs

Video In

- S-Video

Video Out
Not all features or specifications
described in this document may be
available in all probes and/or modes.
- S-Video
Audio Stereo In
VGA out

Connectors
General Electric Company reserves the
right to make changes in specifications
and features shown herein, or
discontinue the product at any time
without notice or obligation. Contact GE
Representative for the most current
information.
- Footswitch
- USB (6)
- Ethernet
- Power for Peripherals








Safety Conformance

GE Healthcare. - America: 888-202-5528 P.O
Box 414, Milwaukee , Wisconsin 53201 USA
The LOGIQ P5 is:


Listed to UL 60601-1 by a Nationally
Recognized Test Lab
GE Healthcare , GE Asia Technology Park
3rd Floor, Building 1,1 Hua Tuo Road ,
Certified to CAN/CSA C22.2 601.1 by an
SCC accredited Test Lab
Shanghai 201203
Tel : +86 21 38774000

LOGIQ P5 Page 14 of 14

Você também pode gostar