Issued on: 01.06.08
Revision: 0
By: R. van Eck
The information contained herein and any other advice are given in good faith based on Sikas current Knowledge and
experience of the products when properly stored , handled and applied under normal conditions in accordance with
Sikas recommendations. The information only applies to the application(s) and product(s) expressly referred to herein
and is based on laboratory tests which do not replace practical tests. In case of changes in the parameters of the
application such as changes in substrates etc, or in case of a different application consult Sikas Technical Service prior
to using Sika products. The information contained herein does not relieve the user of the products from testing them for
the intended application and purpose. All orders are accepted subject to our current terms of sale and delivery. Users
must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which
will be supplied on request.
Sika UAE, Division of Geap Traders L.L.C./ P.O. Box 36334, Dubai, U.A.E.
Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail: sikageap@emirates.net.ae
1/4
C
o
n
s
t
r
u
c
t
i
o
n
Method Statement for Application
of
Sikafloor
-263 SL
Scope:
Application of Self-levelling Wear
Resistance Epoxy Flooring System
(1.5 3.0mm)
N:10.6.10.01.00
Issued on: 01.06.08
Revision: 0
By: R. van Eck
Sika UAE, Division of Geap Traders L.L.C./ P.O. Box 36334, Dubai, U.A.E.
Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail: sikageap@emirates.net.ae
2/4
C
o
n
s
t
r
u
c
t
i
o
n
Products
Si kaf l oor
-161
Si kaf l oor
-263 SL
Si kadur
-504
Description
Si kaf l oor
-263 SL
+ Sikadur
-504 (1:1)
Approx. 1.9
kg/m
2
mixture /1mm
thickness
* Add approx. 1.0-1.5% Extender T by weight of Epoxy material for sloped areas (Ramps &
skirting)
Surface Preparation
Substrate should be sound, clean, dry, fine gripping, free from dust, loose
particles, cement laitance, oil, grease or any other contamination.
This can be mechanically achieved by e.g. captive shotblasting, sandblasting or
equivalent methods.
Note: Surface contamination can be removed by high pressure water jetting
(Min. 150 bar) with the addition of suitable detergents. Concrete parts where oil
has penetrated into the concrete must be removed mechanically. Oil
contamination can be checked by dropping water onto the surface. If a
hydrophobic effect is visible, the surface is contaminated.
Repair minor damages, honeycombing or defects in the concrete surface with
Sikagard
-720 EpoCem
or Sikafloor
-31/41.
The substrate must have a minimum compressive strength of 25 N/mm
2
and
minimum surface tensile (pull-off) strength of 1.5 N/mm
2
.
The moisture content of the substrate must be below 4%; other wise, a
temporary moisture barrier with 2mm minimum thickness of Sikafloor
-81
EpoCem
must be used.
Thorough vacuuming before priming is absolutely necessary.
N:10.6.10.01.00
Issued on: 01.06.08
Revision: 0
By: R. van Eck
Sika UAE, Division of Geap Traders L.L.C./ P.O. Box 36334, Dubai, U.A.E.
Phone: +971 4 286 8656/ Fax: +971 4 286 8657/ E-mail: sikageap@emirates.net.ae
3/4
C
o
n
s
t
r
u
c
t
i
o
n
Mixing
Sikafloor
-161
Stir separately components A and B of Sikafloor
-504 and mix for a further 3 minutes with the slow speed
mixer until a homogeneous mixture is achieved, taking care to entrap as little air
as possible. Place mixed material into a clean container and mix again shortly.
Application
Primer:
Apply the primer coat of Sikafloor
Thinner or
Si ka