7SA522

Distance protection relay for transmission line


frequency 50 Hz or 60Hz(selectable)
Rated current Inom 1A or 5A (selectable)
Power consumption
In CT circuit with Inom=1A 0.05VA
In CT circuit with Inom=5A .30VA
In CT circuit for High sensitive groung (earth) fault protection at 1A .05VA
Thermal overload capability in CT circuit
In CT circuit 100*Inom for 1 sec
30*Inom for 10 sec
4*Inom continuous
In CT circuit for high sensitive ground (earth) fault protection 300 A for 1 sec
100 A for 10sec
15 A contibuous
dynamic overload capability
In CT circuits 250*Inom (one half cycle)
In CT circuit for high sensitive ground (earth) fault protection 250*Inom (one half cycle)
Tolerances Typical 0.3 % of indicated measured value or 0.5 % Inom
50 Hz or 60Hz(selectable)
1A or 5A (selectable)
100*Inom for 1 sec
30*Inom for 10 sec
4*Inom continuous
300 A for 1 sec
100 A for 10sec
15 A contibuous
250*Inom (one half cycle)
250*Inom (one half cycle)
Typical 0.3 % of indicated measured value or 0.5 % Inom
7SJ62
Multi function protection Relay
frequency 50 Hz or 60Hz(selectable)
Rated current Inom 1A or 5A (selectable)
option:Sensitive earth fault CT Iee<1.6A
Power consumption
In CT circuit with Inom=1A 0.05VA
In CT circuit with Inom=5A .30VA
In CT circuit for High sensitive groung (earth) fault protection at 1A .05VA
Overload Capability
Thermal effective 100*Inom for 1 sec
30*Inom for 10 sec
4*Inom continuous
dynamic impulse current 250*Inom (one half cycle)
overload capability if equipped with sensitiveearth fault CT
Thermal efective 300 A for 1 sec
100 A for 10sec
dynamic impulse current 750 A (half cycle)
Range 10% to 200%
Tolerance 0.1 % of indicated measured value or 0.5 % Inom
50 Hz or 60Hz(selectable)
1A or 5A (selectable)
100*Inom for 1 sec
30*Inom for 10 sec
4*Inom continuous
250*Inom (one half cycle)
300 A for 1 sec
100 A for 10sec
750 A (half cycle)
10% to 200%
0.1 % of indicated measured value or 0.5 % Inom
7SS52
Busbar and Breaker failure protection
frequency 50 Hz or 60Hz(selectable)
Rated current Inom 1A or 5A (selectable)
option:Sensitive earth fault CT Iee<1.6A
Power consumption
In CT circuit with Inom=1A <0.1VA
In CT circuit with Inom=5A <0.2VA
Overload Capability
Thermal effective 100*Inom for 1 sec
10*Inom for 10 sec
4*Inom continuous
central unit
Range 0 to 1000% In
Tolerance typically 2% of measured value
bay unit
Range 0 to 6000% In
Tolerance typically 2% of measured value
50 Hz or 60Hz(selectable)
1A or 5A (selectable)
100*Inom for 1 sec
10*Inom for 10 sec
4*Inom continuous
0 to 1000% In
typically 2% of measured value
0 to 6000% In
typically 2% of measured value
7VK61
Breaker Management realy
frequency 50 Hz or 60Hz(selectable)
Rated current Inom 1A or 5A (selectable)
option:Sensitive earth fault CT Iee<1.6A
Power consumption
In CT circuit with Inom=1A approx 0.05 VA
In CT circuit with Inom=5A approx 0.3 VA
Overload Capability
Thermal effective 500A for 1 sec
150 A for 10 sec
20A continuous
Dynamic 1250 A (half cycle)
Tolerance typ. 0.3 % of indicated measured value or 0.5 % Inom
50 Hz or 60Hz(selectable)
1A or 5A (selectable)
approx 0.05 VA
approx 0.3 VA
500A for 1 sec
150 A for 10 sec
20A continuous
1250 A (half cycle)
typ. 0.3 % of indicated measured value or 0.5 % Inom
7UT613
Differential protection relay for transformers, generators, motors and busbars
frequency 50 Hz or 60Hz(selectable)
Rated current Inom 0.1A or 1A or 5A (selectable)
Power consumption
In CT circuit with Inom=1A approx 0.05 VA
In CT circuit with Inom=5A approx 0.3 VA
In CT circuit with Inom=0.1A approx. 0.001
Overload Capability
Thermal effective 100In for 1 sec
30 In for 10 sec
4In continuous
Dynamic 250 A (half cycle)
Tolerance
operational measured values I
L1
I
L2
I
L3
In=5A or 1A 1% of measured value or 1% of In
In=0.1A 1% of measured value or 2% of In
operational measured values 3I
0
I
1
I
2
2% of measured value or 2% of In
50 Hz or 60Hz(selectable)
0.1A or 1A or 5A (selectable)
approx 0.05 VA
approx 0.3 VA
approx. 0.001
100In for 1 sec
30 In for 10 sec
4In continuous
250 A (half cycle)
1% of measured value or 1% of In
1% of measured value or 2% of In
2% of measured value or 2% of In