Você está na página 1de 1

KITCHEN

Laminated wooden flooring

BATHROOM1
Tiles

DRESSING ROOM
Laminated wooden flooring

1
2
3
2
1
3
2 1 3
FRIDGE
W2
D1
build new16mmsupawood
box to be covered with
metal sheeting, to enclose pillars
&make good
Existing window
Build newlevel
&make good
Install newcpb Hob
work top Island
900mmh
Install newhob, extractor
fan &oven as per spec
under counter
oven below
double
cpb
fold out
corner
cpb
300mm
pull out
spice
200mm
tray cpb
build new
sliding door
cpb
900mmh
pull out bin
below
(a
p
p
lia
n
c
e
b
y
p
u
rc
h
a
s
e
r)
20mmsplash back cpb above
cpb above
270
600 1800
9
0
0
4
0
2
8
998
SCULLERY
Tiles

OPEN PLAN MAIN SPACE


Laminated wooden flooring
FFL - 100 000
Under wall plate
103 027
Nok 106 820
W2
Existing window
Refer to appliance spec sheet
for all kitchen appliances
all cupboards to be of 16mmsupawood
in a white high gloss duco finish
all kitchen handles to be satin
0stainless steel handles as per spec
howe roof truss
50 x 50 batterns spaced 150
apart
CODE DESCRIPTION COLOUR SUPPLIER
KM5600
WIDE ON SET FRAME
ELECTRIC HOB
SILVER
MILE
F677
MULTI-FUNCTIONAL
TERMAL VENTALATED
POLISHED STEEL MILE
DA399 WALL MOUNTED
COOKER HOOD
MATT BRUSHED
STAINLESS STEEL
MILE
DIMENTIONS
565 X 5490
600 mm
900mm
APPLIANCE SPEC SHEET
OVEN
PROJ ECT
DRAWI NG
REV:
REG NO:
DWG NO:
DATE:
REV DATE DESCRI PTI ON
* All work, including mechanical and electrical work, is to be done in accordance with the National Building Regulations.
* All materials and workmanship are to comply with the relevant S.A.B.S. codes.
* This drawing is to be deemed to include all that is required for and consistent with good building practice regardless of any
specific omissions.
* This drawing is not to be scaled. Figured dimensions are to be used. All dimensions are in millimetres unless otherwise stated.
* This drawing must be read in conjunction with all relevant drawings and specifications.
* All dimensions and levels must be checked on site by the Contractor before putting any work in hand.
* Any discrepancies on the drawings are to be brought to the Architects attention by the Contractor before putting
any work in hand.
* The Contractor must obtain the Architects written confirmation of any instructions which involve a variation to the
contract before putting that work in hand.
* All voids, suspended ceilings and partitions to be rodent-proofed in accordance with the Government rodent-proofing regulations.
* The Architects retain Copyright of this Drawing.
NOTES:
1:50
TD05
KITCHEN AND BATHROOM
DETAIL
SCALE:
as is design
KITCHEN PLAN
S C A L E 1 : 5 0
SECTION D-D
S C A L E 1 : 5 0
DRAWN BY
ADELE STEYNBERG
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
P
R
O
D
U
C
E
D
B
Y
A
N
A
U
T
O
D
E
S
K
E
D
U
C
A
T
IO
N
A
L
P
R
O
D
U
C
T
P R O D U C E D B Y A N A U T O D E S K E D U C A T I O N A L P R O D U C T
P
R
O
D
U
C
E
D
B
Y
A
N
A
U
T
O
D
E
S
K
E
D
U
C
A
T
IO
N
A
L
P
R
O
D
U
C
T

Você também pode gostar