6FKOXPEHUJHU
Any grid or numerical aquifer NNCs are specified in the GRID section
Different aquifer types may be used in a model but Carter-Tracy and Fetkovich aquifers
cannot be used in the same model.
The number of aquifers and the maximum number of cells to which they are connected is
specified in AQUDIMS in the RUNSPEC section.
08/04/99
6FKOXPEHUJHU
As a grid cell aquifer. To do this: Choose cells beneath the OWC to function as an aquifer
Multiply their pore volume as necessary using MULTPV.
Input any extra connections to the oil and/or gas zone with explicit NNCs using
the NNC keyword.
As a numerical aquifer. To do this: Nominate a number of grid cells, using the keyword
AQUNUM, to function as an
aquifer
08/04/99
6FKOXPEHUJHU
K=1
J
Oil zone
Inactive cells
Grid aquifer
cells
BOX
--I1
I2
1
1
EQUALS
MULTPV
/
ENDBOX
J1
2
J2
8
K1
1
K2
1 /
10000 /
Cells in the water leg of the simulation grid are used as an aquifer
Grid cell aquifers are defined in the GRID and/or EDIT sections.
Pore volume multipliers may be applied and their properties altered in the
GRID
08/04/99
6FKOXPEHUJHU
A great deal of time and effort has to be spent in designing a grid to represent the
aquifer.
08/04/99
6FKOXPEHUJHU
Numerical Aquifers
I
K=1
J
Oil zone
Inactive cells
Numerical
aquifer cells
NNCs to
GRID
AQUNUM
--1
2
3
--Aquifer I
J
--Id
1
8
9
1
9
9
1
10 9
/
AQUCON
--1
2
3
--Aquifer I1
I2
--Id
1
1
1
/
Oil Zone
4
K
5
Area
6
Length
8
K
1
1
1
1E2
1E4
1E6
1E2
1E3
1E4
1
1
1
/
/
/
4
J1
5
J2
6
K1
7
K2
8
Face
I-
9
Depth
9
Trans
mult
/
10
11
Initial
PVT
pressure table
10
Trans
option
12
SAT
table
11
Connection
option
Several redundant cells or cells below the OWC are nominated as aquifer cells
Numerical aquifers are defined in the GRID section.
The cell properties are modified by the AQUNUM keyword
Cells are attached to the oil zone by NNCs defined in the AQUCON keyword
The number of numerical aquifers and NNC is defined in AQUDIMS in RUNSPEC
08/04/99
6FKOXPEHUJHU
Numerical Aquifers
The user is free to select a number of cells to function as an aquifer. In Figure 110 cells
(8-10, 9, 1) have been nominated. They are joined to one another and the reservoir in
the order of entry in the AQUNUM keyword and form a single aquifer. The order of
connections is
(10, 9, 1) flows into (9, 9, 1)
(9, 9, 1) flows into (8, 9, 1)
(8, 9, 1) flows into the reservoir.
The AQUNUM keyword automatically sets zero transmissibility multipliers between the
chosen aquifer cells and their neighbours in the grid to prevent unwanted flows into
adjacent portions of the grid. Note that aquifer cells cannot be deactivated by keywords
including ACTNUM and MINPV.
The cell properties including dimensions, depth, porosity, permeability and regions
definitions are unaltered by default. Despite the fact that these and other quantities are
set using AQUNUM, they must still be defined elsewhere with the standard GRID and
REGIONS section keywords.
The choice of cell dimensions is significant. In Figure 110, cell pore volumes increase
progressively from the oil zone to cell (10, 8, 1) by a factor no greater than 103 between
connected cells. This is intended to minimise throughput-related convergence problems.
It is often recommended to place an extra row of cells to act as a buffer between the
aquifer itself and the oil zone for the same reason. This is unnecessary if the aquifer has
been designed to minimise throughput-related convergence problems from the outset.
The initial aquifer pressure is usually defaulted to ensure it is in hydrostatic equilibrium
with the rest of the simulation grid after initialisation. Instability may nevertheless arise.
Consider Figure 111. The OWC is at a depth, which does not coincide with a cell centre
depth. The attached aquifer is joined to the entire lateral faces of several cells. There is a
difference between the OWC depth and the aquifer depth, i.e. a hydrostatic pressure
difference between the aquifer and oil zone. Water will flow into the reservoir from the
aquifer in the absence of injection and production and the reservoir pressure will drop
until equilibrium is reached. Although this is normally a very minor effect since the
height difference is small, users are strongly recommended to design reservoir grids to
avoid this. The effect may become very significant if:
08/04/99
6FKOXPEHUJHU
Hydrostatic pressure
difference ( w- o)gh
OWC
1
1
1
=
+
T Taq Tgrid
EQ. 57
where
Taq =
2kaqAaq
laq
08/04/99
6FKOXPEHUJHU
EQ. 58
Where kaq, Aaq and laq are the permeability, cross-sectional area and length, respectively,
of cell (8, 8, 1) and Tgrid is calculated as usual. Transmissibility multipliers may be
applied to these connections in the 9th item of AQUCON. Item 8 of AQUCON specifies which
face of cell (8, 8, 1) is joined to the aquifer. The options are I+, I-, J+, J-, K+ and Kwhich represent the direction of increasing and decreasing I, J, and K index,
respectively. In Figure 110 the I- face of any cell is at the left and I+ face is at the right.
The connection option in item 11 determines whether aquifers are permitted to connect
to cell faces that are already joined to other active cells. The default is NO. The
alternative is used in hydrogeological modelling to allow aquifers to be joined to the
interiors of simulation grids in simulations of groundwater propagation within fractures
of insignificant size compared to the grid cells.
08/04/99
6FKOXPEHUJHU
Fetkovich Aquifers
The aquifer inflow is:
Q wi = J w i (P a P i + g ( h i h a )
From material balance the aquifer
pressure response is
W a = C t V w 0 (P a 0 P a )
Integrating these gives
1 exp J t
C tV w 0
Qai = iJ (Pa Pi + g (hi ha ))
J t
C tV w 0
or AQUFETP keywords
Fetkovich aquifers are attached to the oil zone by NNCs defined in the
AQUANCON
keyword
The total number of analytical aquifers and aquifer NNCs is defined in AQUDIMS in
RUNSPEC
08/04/99
6FKOXPEHUJHU
Fetkovich Aquifers
Fetkovich aquifers are based on a pseudo-steady state productivity index and material
balance between aquifer pressure and cumulative influx. The flow is modelled by the
equations in Figure 112 where
the subscripts a and i denote the aquifer and grid cell i, respectively.
Qai is the inflow rate from aquifer to cell i
Jw is the aquifer productivity index;
i is the area fraction for cell i;
Pa is the aquifer pressure at time t
Pi is the cell pressure at time t
is the aquifer water density
hi and ha the cell depth and aquifer datum depth, respectively
Wai is the cumulative influx from aquifer to cell i.
Ct is the total aquifer compressibility
Vw0 is the initial aquifer volume
Pa0 is the initial aquifer pressure
The aquifer flow in Figure 112 is very similar to the familiar well inflow performance
equation. The relationship of aquifer to reservoir is very similar to the relationship of
reservoir to well. Solution of the radial diffusivity equation in which the well is treated
like a reservoir whilst the reservoir is treated like an aquifer provides results analogous
to the familiar results obtained for wells. The consequence is that, given the same
boundary conditions, the aquifer PI is virtually identical in form to a well PI. Fetkovich
aquifers can effectively represent a wide range of aquifer types from the steady state
infinite aquifer which provides constant pressure support to the pot aquifer, which is
small compared to the reservoir and whose behaviour is determined by the reservoir
influx. If the aquifer has a large time constant, it responds slowly to variations in
reservoir pressure and the behaviour approaches that of a steady state aquifer. If the PI
is large so that the time constant is small, the behaviour approaches that of a pot
aquifer which is close to pressure equilibrium with the reservoir at all times. The topic
is also discussed in the ECLIPSE 100 TECHNICAL APPENDICES.
Fetkovich aquifers can be specified using in two ways
AQUFET is used to specify a single aquifer connected to one reservoir face:
AQUFET
--1
Eclipse 100 User Course
4
Page 333 of 499
6
08/04/99
6FKOXPEHUJHU
--Datum
Initial
Initial
rock+
PI
--depth
pressure
volume
water
table
--
@ datum
compressibility
No.
--7
10
11
12
13
14
--I1
I2
J1
J2
K1
K2
Face
Initial
PVTW
Salt concn
--
AQUFETP and AQUANCON are used to specify multiple Fetkovich aquifers and/or aquifers
--Id
Datum
Initial
Initial
rock+
PI
--
depth
pressure
volume
water
--
@ datum
--7
--PVTW
Initial
--table No.
Salt concn
compressibility
AQUANCON
--1
--Id
I1
I2
J1
J2
K1
K2
Face
Influx
--
coefficient
--10
11
--Influx
Connection
--coefficient
option
--multiplier
is defined in AQUDIMS in the RUNSPEC section. Refer to the section titled Numerical
Aquifers for a discussion on the individual items in each record.
AQUANCON specifies the connection data for the aquifer(s). The items that are common to
the AQUCON keyword are discussed in the section on Numerical Aquifers. The aquifer
influx coefficient determines the total communication between the aquifer and cells to
08/04/99
6FKOXPEHUJHU
which it is joined. The default for each cell is its face area. The influx coefficient
multiplier may be applied to the influx coefficient of each aquifer-cell connection.
08/04/99
6FKOXPEHUJHU
Carter-Tracy Aquifers
The main parameters governing
Carter-Tracy aquifer behaviour are
the time constant Tc , which is t/tD ,
and the aquifer influx constant .
wCtr 02
Tc =
c1ka
= c 2hCtr 02
The pressure drop at the aquifer
boundary is
Influence
Function
Qa
Pa 0 P =
PD (tD )
SOLUTION
AQUCT
AQUTAB
AQUANCON
Carter-Tracy aquifers are attached to the oil zone by NNCs defined in the AQUANCON
keyword
The total number of analytical aquifers and aquifer NNCs is defined in AQUDIMS in
RUNSPEC
08/04/99
6FKOXPEHUJHU
Carter-Tracy Aquifers
Carter-Tracy aquifers use tables of dimensionless time td versus dimensionless pressure
Pd(td)to determine the amount of influx. The model approximates a fully transient
model. Limiting cases of the Carter-Tracy aquifer model can represent steady state or
pot aquifers. It has the advantage that intermediate behaviour can also be simulated,
i.e. an aquifer which behaves as a steady state aquifer at first but gradually approaches
the behaviour of a pot aquifer. The flow is modelled by the equations in Figure 113,
where
ka is the aquifer permeability
is the aquifer porosity
w is aquifer water viscosity
Ct is the total aquifer compressibility
r0 is the aquifer inner radius (or reservoir outer radius)
c1, c2 are constants
h is aquifer thickness
is the angle subtended by the aquifer boundary to the centre of the reservoir (the
influence angle)
Qa is aquifer flow rate
Pa0 is the initial aquifer pressure
P is the average water pressure at the aquifer/reservoir boundary
i is the area fraction
tD and PD are dimensionless time and pressure, respectively
a, b are functions of time, , Tc, dimensionless pressure.
The topic is discussed in more detail in the ECLIPSE 100 TECHNICAL APPENDICES.
Carter-Tracy aquifers are specified using AQUCT, AQUTAB and AQUANCON.
AQUCT
--1
--Id
Datum
Initial
rock+
External
--
depth
pressure
water
radius
@ datum
comp.
--
--8
10
11
12
--Thickness
Influence
PVTW
Influence
Initial
--
angle
table No.
fn table No.
salt concn
08/04/99
6FKOXPEHUJHU
The radius is the external radius of the reservoir, or the internal radius of the aquifer.
The influence angle is the angle subtended by the aquifer at the aquifer-reservoir
boundary. Item 11 is a pointer (default value 1) to an influence function defined in
AQUTAB. AQUTAB consists of columns of dimensionless time and dimensionless pressure.
Table number 1 is the default and cannot be altered by the user. It represents a constant
rate terminal aquifer as given by van Everdingen and Hurst.
08/04/99
6FKOXPEHUJHU
08/04/99
6FKOXPEHUJHU
Flux Aquifers
A constant flux aquifer has
water flow
Q ai = F a A im i
To define a flux aquifer use
RUNSPEC
AQUDIMS
SOLUTION
AQUFLUX
AQUANCON
SCHEDULE
AQUFLUX
As regards the
aquifers.
08/04/99
6FKOXPEHUJHU
Flux Aquifers
The water flow Qai into grid cell i from a flux aquifer is as shown in Figure 114 where
Fa is the flux
Ai the area of the connecting cell block, from the cell geometry
mi is an aquifer influx multiplier.
The AQUFLUX keyword contains up to NANAQU records of data, each consisting of an
aquifer identification number and the flux. The flux can be modified during the
simulation by re-entering AQUFLUX in the SCHEDULE section.
08/04/99
6FKOXPEHUJHU
Output Control
Summary Quantities
RPTSOL can output analytic aquifer data and individual connection data
08/04/99
6FKOXPEHUJHU
Output Control
The AAQP aquifer pressure summary quantity applies only to Fetkovich aquifers
Other SUMMARY quantities report instantaneous and cumulative aquifer influxes.
The
The
analytic aquifer data to the PRT file in tabular form. If any of these is set to 2 (e.g.
AQUFET=2) then additional data on the aquifer-grid cell connections is written to
08/04/99