Escolar Documentos
Profissional Documentos
Cultura Documentos
E2000TR/E2500TR
E2000DR/E2500DR
TECHNICAL
SECTION
Via G. Amendola 9 - 44028 Poggio Renatico (FE) - Italy
Tel. +39 0532 829 965 - Fax +39 0532 829 177
E-Mail: info@elenos.com
Internet address: www.elenos.com
Edition 1
Rev. 8 - 14/10/2003
Code MAN0073
Dear Customer,
Firstly, thank you for choosing an
product.
products are solid state or thermionic valve transmitters that develop power
from a minimum of 20W to a maximum of 30KW.
Great care has been taken during the design of the protection circuitry to ensure compatability with products from other manufacturers. However the best performance is achieved when the equipment is used with other products manufactured by
.
The unit has been designed to guarantee consistent performance over time, without the
need for special maintenance. The need for this is minimised by regular functional checks
of those components which are ventilated.
Operation of the unit is very easy and intuitive. Even so it is recommended that this manual
and other relevant documentation is read carefully before any operation is attempted.
Customer Care
Pag. 2
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
CONTENTS
1. GENERAL
1.1. Front view TR version....................................................................Page 7
1.1.1.
Description of the front panel .............................................Page 7
1.2. Rear view TR version ....................................................................Page 9
1.2.1.
Fuse ratings and power supply connection schematic ............Page 9
1.2.2.
Description of the rear panel...............................................Page 9
1.3. Rear view DR version....................................................................Page 10
1.3.1.
Fuse ratings and power supply connection schematic ............Page 10
1.3.2.
Description of the rear panel...............................................Page 10
1.4. Description of materials supplied in the packaging .........................Page 11
2. INSTALLATION
2.1.
2.2.
2.2.
2.3.
2.4.
Unpacking ..................................................................................Page 13
Assembly and disassembly............................................................Page 13
Configuration to the line voltage ...................................................Page 14
Connection to the electrical supply ................................................Page 15
Installation ..................................................................................Page 15
3. USER INSTRUCTIONS
3.1. Powering up ................................................................................Page17
3.2. Description of the graphics interface, setups and measurements
3.2.1.
Main menu .......................................................................Page 17
3.2.2.
Selection menu..................................................................Page 17
3.2.3.
Temperatures menu (TR version) ..........................................Page 18
3.2.4.
Temperatures menu (DR version) .........................................Page 18
3.2.5.
Voltage and current menu (TR version).................................Page 19
3.2.6.
Voltage and current menu (DR version) ................................Page 19
3.2.7.
RF amplifier currents ..........................................................Page 20
3.2.8.
Power limiting configuration menu.......................................Page 20
3.2.9.
LOCKED mode...............................................................Page 21
3.2.10. Modem configuration menu................................................Page 21
3.2.11. System information menu ...................................................Page 22
3.2.12. Alarm list menu .................................................................Page 22
3.3. Performance checks .....................................................................Page 27
3.4. Telemetry connection and operation .............................................Page 29
3.4.1.
SMS operation...................................................................Page 37
3.5. Analog measurements connector ..................................................Page 45
3.6. Diagnostics connector..................................................................Page 47
4. GENERAL DESCRIPTION
4.1. Introduction.................................................................................Page 49
4.1.1.
Protection..........................................................................Page 49
4.1.2.
Measurements ...................................................................Page 49
4.1.3.
Telemetry...........................................................................Page 49
4.1.4.
Indicators ..........................................................................Page 50
4.2. Block diagrams
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 3
Pag. 4
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 5
Pag. 6
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
1.1.
Front view
MONITOR
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
SEL
RESET
ENTER
ST-BY
ADDRESS CONFIG
ON AIR
FAULT
RF MONITOR
IN PWR
E2000
1.1.1.
Front panel description
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
IEE 485
LOCKED
OPEN
MAINS
FM AMPLIFIER
34 5
10
11
Display
Navigation keypad and contrast adjustment (Sx and Dx keys)
Selection and modification keys
System/protection reset key. To reset the system, press the key down for more than 2
seconds.
Stand-by key
Indicator leds
Dip switches for selecting the units address
Disable key
Analog readout
RS 485 interface
RF monitor output ( -63dBc)
N.B.
Do not obstruct the ventialtion grills and periodically clean or replace the filter.
The frequency of this operation will depend on ambient conditions.
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 7
Pag. 8
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
TR Version
1.2.
Rear view
1.2.1.
Fuse ratings and
power supply connection schematic
T1 A
T2 A
T3 A
T1 B
T2 B
T3 B
6,3AT
6,3AT
6,3AT
6,3AT
6,3AT
6,3AT
R
S
N
T
1.2.2.
Rear panel description
1)
2)
3)
4)
5)
FAN 1
EXCITER SUPPLY
FAN 2
AUX SUPPLY
500mAT
500mAT
3,15AT
1AT
EXCITER
SUPPLY
MAX 3,15A
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 9
DR Version
1.3.
Rear view
5 3
EXCITER SUPPLY
1.3.1.
Fuse ratings and
power supply connection schematic
EXCITER
SUPPLY
AC MAINS
MAINS
AUX SUPPLY
FAN 2
FAN 1
1.3.2.
Rear panel description
Pag. 10
1)
2)
3)
4)
5)
6)
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
1.4.
Description of materials supplied in the
packaging
The equipment is supplied inside a wooden box, together with other components
necessary for correct operation.
WARNING
In the event that the parts described below are not included inside
the packaging, contact ELENOS immediately.
In addition to the E2000 amplifier (DR or TR), the following are also supplied:
1) The equipments user and maintenance manual (two separately bound sections)
2) The power supply connector complete with contacts
3) The replacement fuse kit:
6 x 6.3A T fuses
2 x 500mA T fuses
1 x 3.15 A T fuse
1 x 1 A T fuse
8 x 16A R fuses
3
1
2
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 11
Pag. 12
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
2.1.
Unpacking
2.2.
Assembly and
disassembly
The equipment (supplied assembled) is easily disassembled into three main sections (power supply, RF section and ventilation draw) to facilitate transport and installation.
Remove the top cover (just the electronics panel is sufficient) and the bottom cover
Remove the front panel
Disconnect the flat cable from the ALC board at the top of the unit and from the CPU
board, located in the lower part of the unit
Disconnect the fan supply
Disconnect the power supply connections from the RF module
Open the fasteners
To re-assemble the unit, follow the reverse procedure
RF
Ele
Ve
n
tila
tio
c
Se
tio
n
R
ctr
on
ic s
an
FP
el
pa
ne
l
r
we
o
P
nd
raw
ne
ste
Fa
er
ten
s
Fa
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
ply
up
Pag. 13
2.2.
Configuration to the
electrical line voltage
Linear version
The user must verify that the voltage generated by the power supply does not
exceed 50V under no-load conditions (about 45V at full power). Otherwise, the voltage
selector should be changed to conform to the values indicated by the manufacturer.
Switching version
The equipment is supplied configured as requested by the customer. If it becomes
necessary to change the power supply voltage from 380V three-phase or 220V single
phase to 220V three-phase or 110V single phase (to change to 110V single phase, contact ELENOS for further details), consult the schematic of the switching power supply.
Pag. 14
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
2.3.
Connection to the
electrical supply
WARNING
Before proceeding, ensure that there is no voltage present on the
electrical supply to be used for the equipment
In accordance with the power requirements of the equipment, do not use conductors of section less than 2.5mm2
Use a suitable pair of pincers or pliers to fix the contacts of the plug supplied to
the electrical supply cables; for greater security it is advisable to solder the connections.
Insert the contacts into the corresponding sockets of the connector, paying attention to the phases, neutral and earth as indicated in section 1.2.1. and on the legend of
the rear panel.
Connect the plug to the unit.
2.4.
Installation
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 15
Pag. 16
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.1.
Active keys
The display contrast control is active in every menu and is controlled by the left
and right arrow keys.
Any menu can be exited by pressing the SEL key which activates the selection
menu.
The ST-BY key is always active to power up or power down the radio frequency
section.
The RESET key, which is always active, will, when pressed for less than 1.5
seconds, reset the alarm and protection software. If pressed for more, it will reset the
microprocessor system hardware.
3.2.1.
Main menu
(MAIN WINDOW)
FWD 2000 W
Ids
70 A
REF
Vds
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
2 W
50 V
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
3.2.2.
Selection menu
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
MENU
MAIN WINDOW
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
The up/down arrow keys are used to scroll through the menu list (bottom line):
- MAIN WINDOWS
- SYS INFO
- GSM FIELD STRENGTH
- GSM MODEM CONFIG
- TEMPERATURES
- POWER LIMITER SETTINGS
- PSU VOLTAGES-CURRENTS
- RF AMPLIFIER CURRENTS
- ALARMS LIST
The ENTER key selects the chosen menu
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 17
3.2.3.
Temperatures menu
(TEMPERATURES)
TR version
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
ENV 25 | RF A 33 B 33
PSU
A 42
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
3.2.4.
Temperatures menu
(TEMPERATURES)
DR version
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
ENV 25 | RF A 33 B 33
PSU
A 40 B 41 C 39
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
Pag. 18
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.2.5.
Voltage and currents
menu
(PSU VOLTAGESCURRENTS)
TR version
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
50.0
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
3.2.6.
Voltage and currents
menu
(PSU VOLTAGESCURRENTS)
DR version
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 19
3.2.7.
RF AMPLIFIER
CURRENTS
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
3.2.8.
Power limiter settings
menu (POWER
LIMITER SETTINGS)
FWD 2000 W
Thrs 2000 W
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
InPwr 0 W
Err 1.1V
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
Pag. 20
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.2.9.
LOCKED mode
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
ELENOS E 2000-?R
CORRECT WORKING
SEL
RESET
ON AIR
FAULT
IN PWR
ENTER
E2000
ST-BY
MAINS
FM AMPLIFIER
3.2.10.
Modem configuration
menu
(GSM MODEM CFG)
MODEM
STATUS
COMM
:FALSE
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
INIT
:FALSE
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 21
3.2.11.
System information
menu
(SYS INFO)
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
3.2.12.
Alarms list menu
(ALARMS LIST)
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
001 STOP
010 EXTERN. INTERLOCK OP
SEL
ON AIR
FAULT
IN PWR
ENTER
E2000
RESET
ST-BY
MAINS
FM AMPLIFIER
Pag. 22
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Alarms list
Alarm Code
Description
normal operation;
equipment in stand-by;
maximum reflected power limit (software)
exceeded (active);
maximum reflected power limit (software)
exceeded (historical);
maximum reflected power limit (hardware)
exceeded (active);
maximum reflected power limit (hardware)
exceeded (historical);
reflected power warning limit exceeded
(software) (active);
reflected power warning limit exceeded (software)(historical);
equipment blocked (after 5 attempts);
alarm reset active;
The equipment is awaiting reset after
overcurrent protection (TR version);
checksum error in the EEPROM memory;
output power less than half the value pro
grammed in the POWER LIMITER SETTINGS window (active);
output power less than half the value
programmed in the POWER LIMITER
SETTINGS window;
power supply overcurrent (active), (TR
version);
power supply overcurrent (historical)
(TR version);
-12V supply fault (active);
-12V supply fault (historical);
maximum power supply A temperature
(software) exceeded (active);
maximum power supply A temperature
(software) exceeded (historical);
maximum power supply B temperature
(software) exceeded (active);
maximum power supply B temperature
(software) exceeded (historical);
maximum power supply C temperature
(software) exceeded (active);
maximum power supply C temperature
(software) exceeded (historical);
power supply A software warning temperature exceeded (active);
power supply A software warning temperature exceeded (historical);
power supply B software warning temperature exceeded (active);
power supply B software warning temperature exceeded (historical);
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 23
Alarms list
Cod. Alarm
Description
Pag. 24
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Alarms list
Cod. Alarm
Description
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 25
Pag. 26
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.3.
Checking performance
This procedure for checking performance must be carried out if there is any doubt
over the integrity of the equipment as a result of possible transport damage and should
only be performed by expert personnel, capable of using radio frequency measurement
equipment.
Power generated
Connect a good quality wattmeter (e.g. Bird model 43) to the output connector of the
equipment (LC or, by request, 7/8 flange). Connect the output of the wattmeter to a good
quality dummy load (SWR less than 1.05) able to handle at least 2000W continuously,
via a 50 Ohm coaxial cable of suitable section (e.g. Cellflex 1/2). Adjust the maximum
range of the wattmeter to correspond to the power generated (e.g. with a Bird model 43
wattmeter, use a 2500W probe suitably orientated to measure forward power). Switch
on the equipment and check that the power reading on the display corresponds to the
reading on the wattmeter; a difference of upto 50W between the two is acceptable at
nominal power (2000W).
It is of the utmost importance to use a wattmeter which performs to its high quality specification.
A false reading will result if the directional coupler of the wattmeter is not connected
directly to the equipment.
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 27
Pag. 28
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.4.
Telemetry connection
and operation
Each unit has telemetry incorporated which can work with any ANSI terminal,
without the need for special software; for example, Hyperterminal (supplied with Microsoft
Windows (c)), Procomm or Telix for DOS-based systems are all suitable.
Connect the equipment via a suitable cable (not supplied) to an IBM compatible
PC, or to a GSM modem or a traditional network.
Connecting two different interface standards (IE485 con RS232) may seem
strange, but no problems will be encountered, using the configuration shown below. The
signals used are identical, with the exception of their connector position.
CONFIGURATION
E2000 -----------> Modem
MONITOR
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
SEL
RESET
ENTER
ST-BY
ADDRESS CONFIG
ON AIR
FAULT
RF MONITOR
IN PWR
E2000
IEE 485
LOCKED
OPEN
MAINS
FM AMPLIFIER
1 TX
2 TX
3 RX
4 RX
5 BACKUP INPUT
6 GND
7 GND
8 GND
9 GND
Baudrate
Data bits
Parity
Stop bits
Flow control
DCD 1
RxD 2
TxD 3
DTR 4
GND 5
DSR 6
RTS 7
CTS 8
RI 9
9600 bps
8
none
1
none
E2000--------------->PC
MONITOR
ALARM RESET
HOLD 2 SEC FOR
SYSTEM RESET
SEL
RESET
ENTER
ST-BY
ADDRESS CONFIG
ON AIR
IEE 485
LOCKED
FAULT
IN PWR
E2000
MAINS
RF MONITOR
OPEN
FM AMPLIFIER
1 TX
2 TX
3 RX
4 RX
5 BACKUP INPUT
6 GND
7 GND
8 GND
9 GND
ATE0
ATF1
ATQ0
ATX0
ATS0=1
ATV0
ATY0
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
DCD 1
RxD 2
TxD 3
DTR 4
GND 5
DSR 6
RTS 7
CTS 8
RI 9
Echo Off
Local Echo Off
Displays the resulting codes
Displays only codes:
0 (OK)
1 (CONNECT)
2 (RING)
3 (NO CARRIER)
4 (ERROR)
Replies automatically after the first ring
Displays the result codes in numerical form
Defaults to the profile in NVRAM0
Pag. 29
Ignores DTR
Flow control disactivated
Software flow control disactivated
Ignores RTS
Ignores DSR (permanently active)
9600 Baud (maximum)
9600 Baud (minimum)
Writes the configuration to NVRAM 0
Resets the modem to the profile indicated
This sequence of commands is sent directly to the modem from the E2000 by
entering the GSM Modem Config menu and pressing the ENTER key. It is important that
the modem is pre-configured for serial communication in AUTOBAUD mode or at 9600
8N1.
The modem must be equipped with a SIM card enabled for data transmission
and with the PIN code disabled, otherwise it will not be possible to register on the GSM
network. It is recommended, furthermore, to avoid interference from adjacent cells, that a
directive antenna pointed at the closest GSM repeater is used.
TELEMETRY OPERATION
The commands are sent by pressing character keys (case insensitive); for example pressing a displays the main page.
The character can be upper or lower case.
Activation procedure (direct cable connection)
Press 1
The equipment will respond by displaying the main menu
Navigate between the various windows by pressing the corresponding keys
Go back to the Main menu (Q key)
Activation procedure (connection via modem GSM or telephone line)
Connect to the equipment by pressing the telephone number of the modem connected to the equipment
Once the connection is established the equipment will respond by displaying the Main Menu window
Navigate between the various windows by pressing the corresponding keys
Once these passages are completed you will just have to stop the communication
If more than one equipment will be connected to the same modem they will have to be appropriately addressed with the
dip switches on the front panel by using the figures from 1 to 63. Address 0 is the one of the equipment alone, therefore
one apparatus or more will have to be addressed as 1,2,n.
The managing of an equipment via text messages is possible only with an equipment alone, which will be active only if
the address is 0.
For cascade connected machines, the activation procedure is slightly different:
Activation procedure (for Modem or cable connections):
- Press the i character followed by the address (e.g. i03), the equipment will respond by displaying the main menu
window
- Navigate in the various windows
- Go back to the Main Menu
- In case it is needed, select another machine to interrogate (e.g. i04)
- Go back to the Main Menu
- Disconnect
Always remember to digit 0 before every address smaller than 10 (01, 0209), otherwise you will not obtain any
answer.
Pag. 30
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 31
+-----------------------------------------------------------------------------+
| ELENOS 2KW AMPL. <Remote Control V. x.x
- id n
<-Q-> = MAIN MENU |
+-----------------------------------------------------------------------------+
| MAIN MENU.
|
|
|
|
J = SYSTEM SERVICE
|
|
! = ANALOGIC CHANNELS CALIBRATION (CURRENT)
|
|
# = ANALOGIC CHANNELS CALIBRATION (VOLTAGE & TEMPERATURES)
|
|
K = INPUT USER or SYSTEM KEY
|
|
A = SETTING AND READING PARAMETERS
|
|
B = STATUS / FAILURES LIST
|
|
|
|
F = SCHEDULE
(SERVICE)
|
|
L = INTERRUPT ERROR (SERVICE)
|
|
N = INTERNAL STATUS (SERVICE)
|
|
V = SERIAL MONITOR (SERVICE)
|
|
P = SMS PHONE AND ALARMS SETUP
|
|
Q = MAIN MENU (this page!)
|
+-----------------------------------------------------------------------------+
Pag. 32
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 33
Pag. 34
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
WARNING! The user must never modify the values shown in this window!
Currents calibration screen - DR version.
+-----------------------------------------------------------------------------+
| ELENOS 2KW AMPL. <Remote Control V. x.x
- id n
<-Q-> = MAIN MENU |
+-----------------------------------------------------------------------------+
| GAIN AND OFFSET CALIBRATION (CURRENT, A).
|
|
STEP
VALUE
MUL.
DIV.
OFFS.
MIN
MAX STO_L STO_H|
| A1
: R1
C1
C2
C3
C4
C5
C6
C7
C8
C9|
| A2
: R2
|
| A3
: R3
|
| A4
: R4
|
| A5
: R5
|
| B1
: R6
|
| B2
: R7
|
| B3
: R8
|
| B4
: R9
|
| B5
: R10
|
| PSU A: R11
|
| PSU B: R12
|
| PSU C: R13
|
|
|
| STEP = AD Value (0-4095)
MIN
= STEP (0-4095)
|
| VALUE = STEP * MUL./DIV + OFFS.
MAX
= STEP (0-4095)
|
| OFFS. = STEP(offset) * MUL./DIV.
STO_L(H) = Store step MIN(MAX)
|
+-----------------------------------------------------------------------------+
Legend:
Heading: V x.x = software version,-id n = polling address for communication.
C= Column, R= Row.
C1= Value read by the A/D converter (converter step);
C2= Converted integer value (without decimal point);
C3= Multiplier (modifiable field);
C4= Divider (modifiable field);
C5= Offset;
C6= Value (in converter steps)acquired as the lower calibration point;
C7= Value (in converter steps)acquired as the upper calibration point;
C8= Boolean (TRUE/FALSE, modifiable field)to control the acquisition of point C6;
C9= Boolean (TRUE/FALSE, modifiable field)to control the acquisition of point C7.
The automatic calibration procedures must only be performed by specialised ELENOS personnel.
R1 -R4= Amplifier current in heatsink A;
R5 = Not used;
R6 -R9= Amplifier current in heatsink B;
R10 = Not used;
R11 = Switching power supply A current;
R11 = Switching power supply B current;
R11 = Switching power supply C current;
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 35
Pag. 36
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 37
Pag. 38
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Functions description
You can have access to the SMS functions by selecting P = SET SMS PHONE NUMBERS, used for the programming
of the permissions of every registered user.
+-----------------------------------------------------------------------------+
| ELENOS
2 KW AMPL. <Remote Control V.
2.0
- id 0>
MAIN MENU |
+-----------------------------------------------------------------------------+
| MAIN MENU.
|
|
J = SYSTEM SERVICE
|
|
! = ANALOGIC CHANNELS CALIBRATION (CURRENT)
|
|
# = ANALOGIC CHANNELS CALIBRATION (VOLTAGE & TEMPERATURES)
|
|
K = INPUT USER or SYSTEM KEY
|
|
A = SETTING AND READING PARAMETERS
|
|
B = STATUS / FAILURES LIST
|
|
O = LOGOFF
|
|
|
|
F = SCHEDULE
(SERVICE)
|
|
L = INTERRUPT ERROR (SERVICE)
|
|
N = INTERNAL STATUS (SERVICE)
|
|
V = SERIAL MONITOR (SERVICE)
|
|
P = SET SMS PHONE NUMBERS
|
|
|
|
Q = MAIN MENU (this page!)
|
|
|
+-----------------------------------------------------------------------------+
The programming of the user accounts can be done locally, by connecting a PC to the equipment, or remotely. It will
be possible, beside managing the basic functions of the machine, to enable/disable the accounts, modify the telephone
numbers, change the permissions and select the alarm type or the notice to send to the user.
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 39
ACCOUNT PROGRAMMING
In order to use the equipment in the SMS mode it is necessary to digit the telephone numbers (up to 5 users) of all the
people who will have access to the functions. The system will not accept any type of command from telephone numbers
which are not in the list or which are, but are disabled.
Programming with a laptop:
1. Prepare an E2000 - PC connecting cable following the instructions present in the technical manual.
2. Prepare a hyperterminal session for a direct connection to COMx (set up the port to which you will connect the
E2000) with the following communication parameters: 8,N,1 -9600 Baud -No local echo - No Handshaking.
3. Connect the PC to the amplifier.
4. Make sure dip switch 8 is positioned on the left (see Appendix A. SMS communication disabled, default set up), then
turn the amplifier on.
5. Follow the operations described in the Configuration passage.
6. Switch dip switch 8 to the right (activation of the SMS communication).
7. Connect the GSM modem to the IEEE485 port (prepare an E2000 - modem cable following the instructions present
in the technical manual).
8. Make sure the modem is switched on and reset the equipment (press the reset key for longer than 2 seconds)
9. The display will show a message saying that the modem initialisation is running. Once the initialisation is over the
display will show the Main Menu.
Programming from a remote terminal:
1. Prepare an E2000 - Modem cable
2. Switch dip switch no. 8 to the right (see Appendix A. SMS communication activated)
3. Switch the modem on and connect it to the amplifier
4. Reset (press the reset key for longer than 2 seconds) the amplifier and wait for the modem initialisation.
5. Connect, using the remote terminal, to the amplifier and follow the instructions described in the Configuration
passage.
Pag. 40
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Configuration:
After having typed in the password (K key), press the Q key to go back to the Main Menu, then press P to enter the
account configuration window.
+-----------------------------------------------------------------------------+
| ELENOS
2 KW AMPL. <Remote Control V.
2.0
- id 0>
MAIN MENU |
+-------------------------------------+---------+---------+---------+---------+
|
SMS CONFIGURATION
| Enable | Enable | Enable | Enable |
|
| this
| status | command | global |
|
| account | request | execute | echo rx |
|
Example : +393371234567890123 |---------+---------+---------+---------|
|
Phone N.1: +3933811111111
| TRUE
| TRUE
| TRUE
| TRUE
|
|
Phone N.2: +3933822222222
| TRUE
| TRUE
| TRUE
| TRUE
|
|
Phone N.3: +3933833333333
| TRUE
| FALSE | TRUE
| FALSE
|
|
Phone N.4: +3933844444444
| TRUE
| TRUE
| FALSE | FALSE
|
|
Phone N.5: +3933855555555
| FALSE | TRUE
| TRUE
| TRUE
|
|-------------------------------------+---------+---------+---------+---------|
| PWR-UP ALARM:
| TRUE
|
|
| -3dB ALARM:
| FALSE |
|
|-------------------------------------+---------+-----------------------------|
|
ID STRING: ELENOS2000
| COMMAND EXAMPLE: on, PWR 1800, res
|
|-------------------------------------+ Sets PA on air at 1800W output and
|
| Commands: PWR 1234 - set out pwr
| resets the alarm counter.
|
|
ON
- on air
| Commands must be separated by commas. |
|
STBY
- stand-by
| A space must be inserted between
|
|
RES
- reset alarms
| PWR and the value required.
|
|
STS
- status request | Commands are case insensitive.
|
+-------------------------------------+---------------------------------------+
(note: the fields in italic are modifiable by the user)
Type in the telephone numbers (leaving no space at the beginning) also adding the Country code (e.g. +393371234567)
and programme the permissions for each number.
Permissions:
Enable this account: if it is on true mode, the account is enabled for reception and transmission.
Enable Status Request: if it is on true mode, the user will be able to check the equipment functioning status.
Enable Command Execute: if it is on true mode, the user will be able to send commands to the equipment (ON-STBYRES-PWR) otherwise they will not be accepted.
Enable Global Echo: if it is on true mode, the user will receive notices regarding the other users actions.
On the instance presented above, users 1 and 2 have the highest permissions since they have the power to make the
equipment respond to the commands, they can check its functioning and they receive notice of all the other users.
User no.3 can not receive messages of global notice, he can not require the functioning status, but he can send command to the equipment.
User no.4 can only require the functioning status.
User no.5 would have the highest permission but his account is disabled, therefore he will have no control over the
equipment.
Choose the kind of notice sent by the equipment:
PWR-UP: if it is on true mode, once the equipment is connected to the network, it will send, after 2 minutes, a status
message confirming the system activation.
3dB Alarm: if it is on true mode the equipment will send a status message whenever the output power level of the
machine is less than half of the figure set in the POWER LIMITER.
If one wants it is possible to modify the equipment ID STRING by typing in an alphanumeric string of 10 characters
maximum.
The programming is now complete; if it has been done using a remote terminal, it is preferable to end the communication
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 41
Command
Switching-on
Stand By
Power setting
Alarm reset
Status?
Sintax
ON
STBY
PWR nnnn
RES
STS
Example
ON
STBY
PWR 1200
RES
STS
Latency
30 s
10 s
30 s
10 s
10 s
Notes:
1000WOPWRO2200
The commands can be sent one by one, or, if separated by commas, several messages can be sent all in the same
message:
e.g. single command: ON
The first command will turn on the equipment, the second one will turn on the equipment, set the output power to 1500W
and reset the protection counter.
Make sure you follow exactly the indicated syntax otherwise the equipment will not respond to your commands.
STATUS MESSAGE
The status message is a summarising indication of the equipments functioning parameters and it is composed as follows:
1 ELENOS
2 PHCMD ID 02
3 Status
4 000 CORRECT WORKING
5 FWD 2000 W
6 REFL 0 W
7 V 45.0 V
8 I 70.0 A
9 T.Max RF 45 C
10 T.Max PSU 47 C
11 T.Env 27 C
12 ON
Row 1: ID STRING, and 10 characters alphanumeric string modifiable by the user.
Row 2: Message source PhoneCoMmanD ID nn.
The ID of the user who sent the command is visualised. The messages coming from the equipment itself have 00 as ID.
In this example the status message indicated that the command has been sent by user no. 2.
Row 3: Alarm type or notice (Pwr Up, -3dB Alarm, Status) that are sent.
Row 4: Status row. Currently active highest priority alarm.
Row 5: Direct power.
Row 6: Reflected power.
Pag. 42
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Some modems, like the Siemens TC35, can not memorise a configuration predefined by the user, therefore the E2000
must re-initialise them whenever it gets switched on. If by any chance, the connected modem gets turned off, it will not be
able to communicate neither via terminal nor via text messages since there will no longer be any configuration. If this ever
happens as a consequence of maintenance operations or anything else, do not reset or switch the E200 off. Once the
modem is reconnected, you will simply need to select the GSM MODEM CONFIG menu from the front panel, press
ENTER once to enter the menu and once more to start the initialisation procedure.
The process will end when the INIT field is on the TRUE mode.
Check the modem communication is correct by entering the GSM FIELD STRENGHT menu and by reading the level
of reception of the field. This function is useful for the correct setting of the antenna too, and as far as this is concerned
we recommend that you use a directive antenna pointed at the closest GSM repeater.
If the level remains on the -113dBm indicator, there could be either serial communication problems to and from the
E2000, antenna problems or the modem could be having problem registering on the network.
We would like to remember that the PIN number of card to be inserted in the Modem must be disabled, otherwise it will
be impossible for the modem to register on the network.
If the field of reception is satisfactory ( -80dBm at least) the equipment will be ready to work.
We would like to remember that in case of heavy traffic in the GSM network it could be hard, if not impossible, to obtain
the connection via the terminal and/or the messages may be considerably delayed. Such drawbacks do not depend on
the device or the chosen modem but are characteristic of the GSM network and can appear in different ways depending
on the network administrator or the cell serving the working zone of the modem.
Appendix A
ADDRESSING
Dip Switch 1 - 6
Dip switches from 1 to 6 are used for the addressing of the equipment when it operates in a combined system, or when
the same modem is used to monitor several machines.
The address is inserted according to the binary code and the weight of every switch equals the power of 2 raised to n-1,
where n corresponds to the switch number on the ON mode.
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 43
The address 0 (default) is the one of the equipment alone. For combined systems or for several machines connected to
the same modem one will have to choose the addresses going from 1 to 63.
We would like to remember that the management of the equipment via text messages will be active only for single
machines having the address 0.
**Dip switch 7
Power supplier energy selection:
OFF = TR version
ON = DR switching version
**WARNING!
This dip switch is set up at the factory according to the kind of power supplier that goes
with the amplifier and must not be modified, unless the power supplier is changed.
Dip switch 8
Activation of text messaging management:
OFF = disabled SMS communication (default).
ON = Enabled SMS communication.
It is possible to disable the SMS communication whenever there is not a GSM modem connected to the equipment or in
case one is not interested in this kind of service, so that there is no need to wait for the modem initialisation during the
powering up of the machine.
Pag. 44
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.5.
Analog measurements
connector
This connector is located on the front panel of the E2000 amplifier and enables connection to a telemetry system with analog inputs.
It is possible to select the various measurement banks (0- modules currents, 1 - power
supply voltage/current, 2 - temperature, 3 - power/efficiency) by connecting the two input
selectors SEL 0 and SEL 1 to ground.
The electrical characteristics of the port are as follows:
=
=
=
11K
2V
2.5V
1
9
2
10
3
11
4
12
5
13
6
14
7
15
8
Output impedance
Full-scale voltage
Max output voltage
SEL 0
SEL0
OPEN
OPEN
SEL1
MON 0
FWD
OPEN
CLOSED I PSU A
CLOSED OPEN
CLOSED
CLOSED
Temp
PSU A
I a1
MON 1
REF
I PSU B
MON 2
IN PWR
I PSU C
MON 3
ERR V
VDS
MON 4
VDS
+5V
MON 5
Id
+12V
MON 6
Tmax RF
-12V
Temp
PSU B
I a2
Temp
PSU C
I a3
None
Temp
Env
I b1
Temp
RF A
I b2
Temp
RF B
I b3
I a4
GND
M O NIT O R 0
M O NIT O R 1
M O NIT O R 2
M O NIT O R 3
M O NIT O R 4
M O NIT O R 5
M O NIT O R 6
M O NIT O R 7
SEL 1
MON 7
Tmax PSU
Currents
sum
None
I b4
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 45
Pag. 46
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
3.6.
Diagnostics connector
2
3
4
5
6
8
9
10
/DI_TX_ON
/DI_TX_OFF
/DI_RESET
/DI_ENABLE
DI_COMMON
DO_ON
DO_ON_AIR
DO_FAILURE
DO_-3dB
DO_COMMON
DI_TX_ON:
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 47
Pag. 48
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
4.1.
Introduction
4.1.1.
Protection
4.1.2.
Measurements
The directional coupler for measuring forward and reflected power, is thermocompensated in order to resist variations of ambient temperature. All the transducers present in the unit are designed for total immunity to RF fields to prevent problems arising
from false readings.
All operational parameters, besides being displayed on the front panel, are available in analog form, for users wanting to connect the unit to a telemetry system.
4.1.3.
Telemetry
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 49
4.1.4.
Indicators
In addition to the alphanumeric 24x2 display, the following indicator leds are visible on
the front panel:
OnAir = Transmitter ready to operate.
Fault
Mains = The line supply voltage is present and the diagnostic board program has run
correctly.
Pag. 50
Pwr
StBy
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
4.3.
Power supply section
The E2000 unit is available in two versions: the linear power supply version
(E2000TR) and the switching power supply version (E2000DR).
It is possible to modify the latter to operate in three-phase or single phase configuration at 220 or 380 V.
The linear power supply version, however, can only operate at 220 or 380V
three-phase.
4.3.1.
Linear power supply
This comprises two rugged sections connected in parallel. The transformers and
rectifier are protected against over-temperature and current overload (45 A max. per section).
4.3.1.
Switching power
supply
This consists of three units connected in parallel and balanced by a currentsharing circuit. Each section is protected against over-temperature and over-current.
4.3.2.
Auxiliary power supply
This board is slightly different in the two versions, DR and TR, and supplies the
unit with all the supply voltages for the control circuits and also receives the signals from
the user interface connector (USER INTERFACE) and transfers them to the CPU.
Title:
Board Code:
E2K 6A000_1
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 55
J10
SMB
J9
SMB
Microstrip 90 70.7Ohm
50R
Microstrip 90 70.7Ohm
R19
50R
J8
SMB
R12
100R
Microstrip 90 35 Ohm
Microstrip 90 70.7Ohm
R18
50R
J7
SMB
R17
50R
Microstrip 90 70.7Ohm
Microstrip 90 70.7Ohm
R14
50R
R11
50R
Microstrip 90 70.7Ohm
R10
50R
2PCB0262
Microstrip 90 35 Ohm
Microstrip 90 70.7Ohm
R9
50R
R16
50R
C2
4.7nF
J6
2
1
2PCB0261
R15
100K
J5
SMB
D1
HSMS2850
-34dB
C1
180pF
Microstrip 50 Ohm
R16
68R
Title:
SPLITTER INPUT
Rev
E2000
Board Code:
Model:
Approved : A.Giovannelli
Sheet
of
4.4.2.
RF modules
C18
C19
C13
These are designed using planar technology for the input impedance transformer
and a transmission line transformer for the output matching circuit.
C16
C17
L2
R9
C12
C15
C14
50 Ohm
C11
R8
25 Ohm
25 Ohm
L1
U1
C7
R2
C8
R3
C6
D1
R1
C4
C3
C5
P1
R7
TF1
R4
R5
2PCB0252_1
R8
Microstrip 90 70.7Ohm
J4
SMB
This is a classic Wilkinson splitter with eight outputs using micro-strip technology
J3
SMB
4.4.1.
Input splitter
J2
SMB
Comprises two banks of 1000W, each containing a total of eight 300W modules. The power combiners are designed to allow operation of the unit in any unbalanced
condition caused by the failure of one or more RF modules.
J1
SMB
4.4.
Radio frequency section
C9
C10
R6
C2
Pag. 56
C1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
4.4.3.
Output combiner
2PCB0256
2PCB0256
Microstrip 75 Ohm
Microstrip 75 Ohm
PORT 1/A
PORT 3/A
R1
100R
R6
R4
100R
100R
PORT 2/A
PORT 4/A
Microstrip 75 Ohm
Microstrip 75 Ohm
RG302 90
RG302 90
R3
100R
AL FILTRO PASSABASSO
RG302 90
RG302 90
RG302 90
RG302 90
Microstrip 75 Ohm
Microstrip 75 Ohm
PORT 1/B
PORT 3/B
R2
100R
R7
100R
R5
100R
2PCB0256
Microstrip 75 Ohm
2PCB0256
PORT 2/B
PORT 4/B
Microstrip 75 Ohm
Title:
OUTPUT COMBINER
Rev
E2000
Board Code:
Model:
Approved : A.Giovannelli
Sheet
of
4.4.4.
Low-pass filter and
directional coupler
This filter removes the harmonics generated by the non-linear operation of the
amplifier and guarantees a level of residual harmonics and spurious signal content within
current regulations.
The directional coupler is thermally compensated and allows reading of both
forward and reflected power.
4.4.5.
Shunt boards
These boards are housed in the front part of the RF section and individually measure the currents drawn by the 8 power modules.
Title:
E2K 3A000_1
E2000
of
1
Rev
Model:
Approved : A.Giovannelli
Sheet
Website WWW.ELENOS.COM
CURRENT SENSOR
Board Code:
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 57
4.4.6.
CPU board
The board is designed around the NEC V25 (Intel 8086), a powerful microprocessor which enables easy and reliable control of the unit.
Title:
CPU BOARD
Board Code:
E2K 2A000_1
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
4.4.7.
ALC board
This board, housed in the front of the RF section, gathers and normalises the
readings from all the sensors present in the RF section, stabilizes the output power at the
value set by the user, protects the RF section in the event of excessive SWR and interacts
with the CPU board for displaying data.
Title:
ALC
Board Code:
E2K 5A000_1
Pag. 58
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 59
Pag. 60
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
Description
BRDG1
130MT80KB
BRDG2
130MT80KB
C1
15000uF
C2
15000uF
C3
15000uF
C4
15000uF
C5
100nF
C6
100nF
C7
100nF
F1
6.3AT
F2
6.3AT
F3
6.3AT
F4
6.3AT
F5
6.3AT
F6
6.3AT
F7
1AT
F9
500mAT
F8
500mAT
F10
4AT
J1
CON2
J2
CON2
J7
CON3
J3
CON3
J4
CON4
J5
CON4
J6
CON4
J8
CIRCLE
J32
CON MC4
K1
Telemecanique LC1 D1810M7
K2
OMRON MK3P5-S
L2
500uH
L1
500uH
R1
50/20W
R2
50/20W
R3
50/20W
R4
330/10W
R5
330/10W
R6
0.0012R
R7
0.0012R
T1
TF
T2
TF
T3
TF
T4
TF
T5
TF
T6
TF
T7
PR. 220V sec 15 + 15 V 2A
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 63
Pag. 64
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
D1
D2
D3
F4
F5
F6
F7
J1
J2
J4
J3
K1
S1
T1
Description
40EPS08
40EPS08
40EPS08
VD. CONFIG
VD. CONFIG
VD. CONFIG
VD. CONFIG
CON3
CON3
CON3
CON4
Telemecanique LC1 D1810M7
INT. MAGNETO-TERMICO
PR. 220V sec 15 + 15 V 2A
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 67
Pag. 68
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
VERSIONE A 220V
VERSIONE A 110V
EBM A2E200-AI38-01TW
EBM A2E200-AI38-01TW
EBM A2E200-AI86-70TW
EBM A2E200-AI86-70TW
M1
M2
M1
M2
GIALLO-VERDE
MARRONE
BLU
NERO
GIALLO-VERDE
MARRONE
BLU
C1
5u 400V
C2
5u 400V
4
3
2
1
C2
1u5 400V
NERO
MARRONE
BLU
GIALLO-VERDE
4
3
2
1
C1
1u5 400V
NERO
GIALLO-VERDE
MARRONE
BLU
NERO
J1
CON4
J1
CON4
VERSO ALIMENTATORE
VERSO ALIMENTATORE
Title:
E2000
Board Code:
Model:
Approved : A.Giovannelli
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Sheet
of
Pag. 69
Component list
Ref.
C1
C2
C2
C1
J1
J1
M1
M2
M2
M1
Pag. 70
Description
1u5 400V
1u5 400V
5u 400V
5u 400V
CON4
CON4
EBM A2E200-AI38-01TW
EBM A2E200-AI38-01TW
EBM A2E200-AI86-70TW
EBM A2E200-AI86-70TW
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Title:
Board Code:
E2K 6A000_2
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 71
Pag. 72
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
1nF
C40
/DO PSU_RESET
Q4
Q3
BC856
2
1
PML4148
3
/DO PSU_RESET
R71
1K
DL14
KP2012ID
C46
R63
1K
D20
4.7V
R68
1K
PML4148
U4B
LM324
D17
D18
4.7V
R65
2.2K
R67
100
TRIP
2.2M
R57
C44
13
+12
12
11
10
11
1uF
C45
~ 47.5A
PML4148
14
U4D
LM324
D10
4.7K
R66
PML4148
U4C
LM324
R61
2.2M
D11
R69
470
R70
1K
3.8V
+12
11
6
1uF
R64
4.7K
1nF
2
1
R74
2.2K
D12
+12
BC846
R51
100R
TL_ENABLE
CURR_ALERT
CURR_ALERT
TL_ENABLE
R56
3.9K
TRIG1
TRIG2
U4A
LM324
100nF
TRIG1
C54
+12
11
TRIG2
R60
10K
R59
10K
R58
1K
9.55 V
Title:
Board Code:
E2K 6A000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 75
Pag. 76
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
II4M-R
1
2
3
4
J2
II4M-R
1
2
3
4
J3
L3
L4
L5
L6
C3
1nF
100uH
100uH
R3
1K
C5
1nF
100uH
100uH
R23
1.13K
C4
1nF
R27
1.13K
C6
1nF
+12
E2K 6A000_1
+
7
1uF
10.2K
LMC6482IN
U1B
100nF
1uF
C20
C14
LMC6482IN
10.2K
C19
R25
R22
2M2
U2B
R28
R26
2M2
8
4
R24
1K
R29
1K
1nF
C56
AI_PSU_T_2
1nF
C55
AI_PSU_T_1
II4M-R
4
3
2
1
J8
II4M-R
1
2
3
4
J1
L1
L2
C2
1nF
C31
100nF
C25
100nF
C18
100nF
R10
1.13K
DL4
KP2012ID
L8
100uH
C30
100nF
C26
100nF
L7
100uH
C1
1nF
100uH
100uH
R2
1K
R38
470R
R40
1K
+12
+12
+
1
C35
100nF
R49
4.7K
C29
100nF
DL5
KP2012ID
R39
470R
1uF
C9
R37
4.7K
10.2K
R36
1K
LMC6482IN
U1A
R12
R9
2M2
8
4
R4
1K
8
4
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
2
R11
1K
3
1
Board Code:
Title:
+12
Q2
BC846
Q1
BC846
R62
100R
R50
100R
1nF
C57
1nF
C42
/DI XFR_T_ALARM
1nF
C39
/DI XFR_T_WARNING
AI_PSU_T_3
Website WWW.ELENOS.COM
Model:
Sheet
E2000
Rev
Approved : A.Giovannelli
of
Pag. 79
TRIG2
C51
AI_PSU_I_2
TRIG2
1nF
C17
1nF
II4M-R
p=80Hz
100nF
C24
R33
R8
100R
R32
22R
C23
100nF
II4M-R
100nF
C8
2
1
J5
20K
LMC6482IN
R34
1K
7
6
100nF
C22
R30
R31
22R
R7
100R
U3B
20K
100nF
C21
voltage probe
p=80Hz
C13
R17
22R
R6
100R
R18
From capacitors
2
J7
100nF
20K
LMC6482IN
C12
100nF
100nF
C7
2
1
J4
AI_PSU_I_2
R13
2.2K
R20
1.8K
D2
PML4148
1nF
C49
R19
1K
+
3
100nF
C11
D4
PML4148
AI_PSU_I_1
AI_PSU_I_1
TRIG1
TRIG1
U3A
+12
C16
20K
100nF
100nF
II4M-R
Shunt2
R15
C10
R16
22R
R5
100R
LMC6482IN
U2A
3
C15
+12
Vout=10V @ 50A
100nF
R14
1K
C52
1nF
AI PSU_V
Shunt1
Title:
Board Code:
E2K 6A000_1
Pag. 80
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C1
C2
C3
C4
C5
C6
C17
C32
C36
C37
C38
C39
C40
C41
C42
C43
C46
C47
C48
C49
C50
C51
C52
C53
C55
C56
C57
C58
C59
C60
C61
C62
C67
C68
C69
C7
C8
C10
C11
C12
C13
C14
C15
C16
C18
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
Description
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 81
Component list
Ref.
C31
C35
C54
C9
C19
C20
C44
C45
C33
C34
C70
C71
C63
C64
C65
C66
DL1
DL2
DL3
DL6
DL7
DL8
DL9
DL10
DL11
DL12
DL13
DL4
DL5
DL14
DL15
DL16
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D17
D20
D18
D19
F2
F1
H1
Pag. 82
Description
HOLE3.5MM
100nF
100nF
100nF
1uF
1uF
1uF
1uF
1uF
100uF 25V
100uF 25V
100uF 25V
100uF 25V
1000uF 25V
1000uF 25V
1000uF 25V
1000uF 25V
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012SGD
KP2012ID
KP2012ID
KP2012ID
LED VERDE
LED VERDE
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
4.7V
4.7V
KBU8D
FUSE
FUSE
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
H2
H3
H4
ISO1
ISO2
ISO3
ISO4
JP1
JP2
J1
J2
J3
J4
J5
J7
J8
J6
J9
J10
J11
L1
L2
L3
L4
L5
L6
L7
L8
PWR1
Q1
Q2
Q4
Q3
RL1
RL2
RL3
RL4
RL5
RL6
RL7
R1
R2
R3
R4
R11
R14
R19
R21
R24
R29
R34
R35
R36
R40
R42
Description
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
TLP181
TLP181
TLP181
TLP181
JUMPER
JUMPER
II4M-R
II4M-R
II4M-R
II4M-R
II4M-R
II4M-R
II4M-R
W4M-R
5+5M-R
17+17M-R
W3M-R
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
NME1212S
BC846
BC846
BC846
BC856
JW1FSN-12VDC
JW1FSN-12VDC
JW1FSN-12VDC
OMRON G5V-1 12VDC
OMRON G5V-1 12VDC
OMRON G5V-1 12VDC
OMRON G5V-1 12VDC
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 83
Component list
Ref.
R44
R46
R48
R52
R53
R54
R55
R58
R63
R68
R70
R71
R72
R73
R5
R6
R7
R8
R50
R51
R62
R9
R22
R26
R10
R23
R27
R12
R25
R28
R13
R65
R74
R15
R18
R30
R33
R16
R17
R31
R32
R20
R37
R41
R43
R45
R47
R49
R64
R66
R39
R38
R56
R57
R61
Pag. 84
Description
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
100R
100R
100R
100R
100R
100R
100R
2M2
2M2
2M2
1.13K
1.13K
1.13K
10.2K
10.2K
10.2K
2.2K
2.2K
2.2K
20K
20K
20K
20K
22R
22R
22R
22R
1.8K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
470R
470R
3.9K
2.2M
2.2M
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
R59
R60
R67
R69
U1
U2
U3
U4
U5
U6
Description
10K
10K
100
470
LMC6482IN
LMC6482IN
LMC6482IN
LM324
LM7912C
LM1085-12T
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 85
Pag. 86
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Title:
Board Code:
E2K AA000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 87
Pag. 88
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
AI_PSU_I_3
AI_PSU_I_2
AI_PSU_I_1
AI_PSU_I_3
AI_PSU_I_2
AI_PSU_I_1
AO_PSU_REF
1
3
5
7
9
1
3
5
7
9
1
3
5
7
9
+
+
+
+
+
+
+
+
+
+
+
+
+
+
+
5+5M-R
+
+
+
+
+
J6
5+5M-R
+
+
+
+
+
J7
5+5M-R
+
+
+
+
+
2
4
6
8
10
2
4
6
8
10
2
4
6
8
10
+12
+12
R21
1K
R36
1K
/DI_PSU3_ALARM
/DI_PSU2_ALARM
+12
R48
1K
/DI_PSU1_ALARM
KPT20125D
DL7
KPT20125D
DL12
/DI_PSU3_ALARM
/DI_PSU2_ALARM
KPT20125D
DL13
/DI_PSU1_ALARM
1
3
3
2
1
3
3
2
AO_PSU_REF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
E2K AA000_1
3
Board Code:
3
Title:
Model:
Sheet
4.7K
4.7K
4.7K
Q2
BC846
R35
JUMPER
JMP1
R24
4.7K
Q4
BC846
R46
JUMPER
JMP2
R39
4.7K
Q6
BC846
R54
JUMPER
JMP3
R51
4.7K
R33
10K
R34
10K
Q1
R44
10K
R45
10K
Q3
R52
10K
R53
10K
Q5
1
1
1
J8
R23
10K
BC856
R38
10K
BC856
R50
10K
BC856
R22
10K
R37
10K
R49
10K
C20
100nF
C26
100nF
C33
100nF
+12
+12
R47
4.7K
+12
/DO_INHIBIT
/DO_INHIBIT
Website WWW.ELENOS.COM
E2000
Rev
Approved : A.Giovannelli
of
Pag. 93
1nF
C32
1uF
10.2K
C8
R9
C1
1nF
R16
1uF
C11
10.2K
LMC6482IN
-
+
5
R13
2M2
C3
1nF
100uH
CON4
L3
L4
J2
CON4
1
2
3
4
100uH
R14
1.13K
C4
1nF
C5
1nF
R2
1K
R18
1.13K
100uH
L5
100uH
L6
J3
1
2
3
4
R3
1K
C6
1nF
+12
+12
C9
U1B
1uF
C12
R19
10.2K
LMC6482IN
100nF
R15
1K
C31
1nF
1
2
3
4
AI_PSU_T_2
J1
1nF
C30
CON4
L1
L2
100uH
100uH
R7
1.13K
C2
1nF
R1
1K
C7
1nF
CON2
2
1
AI_PSU_T_1
7
U2B
+
+
3
R6
2M2
+12
R10
2.2K
R4
1.8K
J4
LMC6482IN
U1A
LMC6482IN
2
U2A
100nF
D2
PML4148
D1
PML4148
R20
1K
+12
C10
+12
R17
2M2
R11
1K
C29
1nF
R8
1K
AI PSU_V
AI_PSU_T_3
Title:
Board Code:
E2K AA000_1
Pag. 94
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C1
C2
C3
C4
C5
C6
C7
C15
C16
C19
C21
C22
C23
C24
C25
C27
C28
C29
C30
C31
C32
C34
C35
C36
C37
C42
C43
C44
C45
C8
C11
C12
C9
C10
C13
C14
C20
C26
C33
C17
C18
C46
C47
C38
C39
C40
C41
DL1
DL2
DL3
DL4
DL5
DL6
DL8
DL11
Description
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1uF
1uF
1uF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100uF 25V
100uF 25V
100uF 25V
100uF 25V
1000uF 25V
1000uF 25V
1000uF 25V
1000uF 25V
KPT20125GD
KPT20125GD
KPT20125GD
KPT20125GD
KPT20125GD
KPT20125GD
KPT20125GD
KPT20125GD
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 95
Component list
Ref.
DL14
DL15
DL7
DL9
DL10
DL12
DL13
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
F1
F2
H1
H2
H3
H4
ISO1
ISO2
ISO3
ISO4
JP1
JMP1
JP2
JMP2
JMP3
J1
J2
J3
J4
J5
J11
J6
J7
J8
J9
J10
L1
L2
L3
L4
L5
L6
PWR1
Q1
Q3
Pag. 96
Description
KPT20125GD
KPT20125GD
KPT20125D
KPT20125D
KPT20125D
KPT20125D
KPT20125D
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
PML4148
BRIDGE
FUSE
FUSE
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
TLP180
TLP180
TLP180
TLP180
JUMPER
JUMPER
JUMPER
JUMPER
JUMPER
CON4
CON4
CON4
CON2
W3M-R
W3M-R
5+5M-R
5+5M-R
5+5M-R
5+5M-R
17+17M-R
100uH
100uH
100uH
100uH
100uH
100uH
NME1212S
BC856
BC856
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
Q5
Q2
Q4
Q6
RL1
RL2
RL3
RL4
RL5
RL6
R1
R2
R3
R5
R8
R11
R12
R15
R20
R21
R26
R28
R30
R32
R36
R40
R41
R42
R43
R48
R55
R56
R4
R6
R13
R17
R7
R14
R18
R9
R16
R19
R10
R22
R23
R33
R34
R37
R38
R44
R45
R49
R50
R52
R53
Description
BC856
BC846
BC846
BC846
JW1FSN-12VDC
JW1FSN-12VDC
OMRON G5V-1 12VDC
OMRON G5V-1 12VDC
OMRON G5V-1 12VDC
OMRON G5V-1 12VDC
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1.8K
2M2
2M2
2M2
1.13K
1.13K
1.13K
10.2K
10.2K
10.2K
2.2K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 97
Component list
Ref.
R24
R25
R27
R29
R31
R35
R39
R46
R47
R51
R54
U1
U2
U3
U4
Pag. 98
Description
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
4.7K
LMC6482IN
LMC6482IN
LM7912C/TO220
LM1085-12T
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
IOD[0..7]
/DI_XFR_T_WARNING
/DI_XFR_T_ALARM
/DI_PSU_ALARM
R59
R61
100K
100K
/DI_ALARM_BUS
/CN_INTLK
/DI_ALARM_BUS
/CN_INTLK
100nF
100nF
100nF
100nF
/DI_XFR_T_WARNING
/DI_XFR_T_ALARM
/DI_PSU_ALARM
C4
C69
+12V
C111
VCC
U1A
1
9
TD62083AF
IN
EM
OUT
CA
U1B
2
9
U2
74HC273M
2
5
6
9
12
15
16
19
IN
EM
OUT
CA
16
10
R32
2K2
DO_TL2
DO_TL2
/DO_PSU_RESET
/DO_PSU_RESET
/DO_ALARM_RST
/DO_ALARM_RST
Q1
BC846
VCC
CLK
CLR
DO_TL1
TD62083AF
3
9
17
10
R34
2K2
/DO_PA_INHIBIT
1Q
2Q
3Q
4Q
5Q
6Q
7Q
8Q
DO_TL1
/DO_PA_INHIBIT
Q2
BC846
11
1
1D
2D
3D
4D
5D
6D
7D
8D
OUT
CA
100nF
/CS2
/RST
3
4
7
8
13
14
17
18
18
10
TD62083AF
IN
EM
U1C
C75
IOD0
IOD1
IOD4
IOD5
IOD7
IOD6
IOD3
IOD2
/CS2
/RST
100K
100K
100K
/CS3
100nF
/CS3
R2
R1
R3
+12V
1
19
C68
G1
G2
2
3
4
5
6
7
8
9
C9
A1
A2
A3
A4
A5
A6
A7
A8
100nF
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
C1
18
17
16
15
14
13
12
11
C5
IOD0
IOD1
IOD2
IOD3
IOD4
IOD5
IOD6
IOD7
100nF
U3
74HC541M
A_MPX2
A_MPX1
A_MPX0
A_MPX2
A_MPX1
A_MPX0
U9
74HC273M
/CS4
/RST
11
1
1D
2D
3D
4D
5D
6D
7D
8D
+12V
U1H
1Q
2Q
3Q
4Q
5Q
6Q
7Q
8Q
2
5
6
9
12
15
16
19
8
9
IN
EM
OUT
CA
11
10
DO_ON_AIR
DO_ON_AIR
14
10
DO_-3dB
DO_-3dB
13
10
DO_ON
DO_ON
12
10
DO_FAILURE
DO_FAILURE
15
10
DO_FAN
DO_FAN
TD62083AF
U1E
5
9
IN
EM
OUT
CA
TD62083AF
CLK
CLR
VCC
C6
/CS4
/RST
3
4
7
8
13
14
17
18
100nF
IOD0
IOD1
IOD4
IOD5
IOD7
IOD6
IOD3
IOD2
U1F
6
9
IN
EM
OUT
CA
TD62083AF
U1G
100nF
C2
VCC
7
9
IN
EM
OUT
CA
TD62083AF
U1D
4
9
IN
EM
OUT
CA
TD62083AF
DAC1EN
DAC1HW
DAC1EN
DAC1HW
G1
G2
/CS5
100nF
100nF
/SELM0
/SELM1
C62
/SELM0
/SELM1
C63
2
3
4
5
6
7
8
9
100nF
A1
A2
A3
A4
A5
A6
A7
A8
C61
Y1
Y2
Y3
Y4
Y5
Y6
Y7
Y8
100nF
18
17
16
15
14
13
12
11
C60
U4
74HC541M
IOD0
IOD1
IOD2
IOD3
IOD4
IOD5
IOD6
IOD7
R33
R35
R58
R56
100K
100K
100K
100K
/DI_ENABLE
/DI_TX_ON
/DI_TX_OFF
/DI_RESET
/DI_ENABLE
/DI_TX_ON
/DI_TX_OFF
/DI_RESET
1
19
/CS5
Title:
DIGITAL I/O
Board Code:
E2K 2A000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 111
Component list
Ref.
CN1
CN2
CX1
C1
C2
C3
C4
C5
C6
C7
C8
C9
C18
C19
C30
C31
C60
C61
C62
C63
C64
C65
C66
C67
C68
C69
C70
C73
C74
C75
C76
C77
C78
C80
C82
C83
C84
C85
C86
C87
C88
C89
C90
C91
C92
C93
C94
C95
C96
C97
C98
C99
C100
C101
C102
Pag. 112
Description
CONN DSUB 9-R
CONN DSUB 15-R
10uF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C103
C104
C105
C106
C108
C109
C111
C113
C114
C115
C116
C117
C118
C121
C122
C124
C126
C127
C130
C131
C141
C154
C155
C159
C160
C162
C163
C10
C11
C12
C13
C14
C15
C16
C17
C20
C21
C22
C23
C24
C25
C26
C27
C28
C29
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
Description
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 113
Component list
Ref.
C42
C43
C44
C45
C46
C47
C48
C49
C50
C51
C52
C53
C54
C55
C56
C57
C58
C59
C128
C132
C133
C134
C135
C136
C137
C138
C139
C144
C145
C146
C147
C148
C149
C150
C151
C152
C153
C71
C140
C142
C156
C72
C79
C107
C119
C123
C161
C81
C110
C125
C143
C112
C120
C129
C157
Pag. 114
Description
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
100uF 25V
100uF 25V
100uF 25V
100uF 25V
470uF 16V
10uF 16V
10uF 16V
10uF 16V
10uF 16V
10uF 16V
1uF
1uF
1uF
1uF
22pF
22pF
68pF
68pF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C158
C164
DX1
DX2
DX3
DZ1
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D17
D18
H1
H2
H3
H4
JP1
JP2
JP3
JP4
J1
J2
J3
J4
L1
L2
L3
QX2
QX1
QX3
Q1
Q2
RV1
RX2
RV2
R57
R60
R62
R63
R64
R65
R66
R68
Description
68pF
68pF
1N4007
1N4007
9V1
ZRB500F
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
HOLE3.2MM
HOLE3.2MM
HOLE3.2MM
HOLE3.2MM
JUMPER
JUMPER
JUMPER
JUMPER
CON24AP
CONN RCPT 17x2
CON16
STRIP FEMALE 2.54 RIGHT 26P
1OOnH
1OOnH
1OOnH
BC337
BC337
BSP316
BC846
BC846
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 115
Component list
Ref.
R85
R90
R91
R96
R97
R98
R99
R103
R104
R105
R106
R110
R119
R120
R121
R122
R123
R124
R125
R126
R127
R128
R129
R130
R139
R140
R141
R142
R143
R144
R145
R146
R147
R148
R184
R185
R187
R188
R189
R192
R193
RX1
R1
R2
R3
R33
R35
R56
R58
R59
R61
R160
R161
RX3
R5
Pag. 116
Description
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
100K
100K
100K
100K
100K
100K
100K
100K
100K
100K
100K
100K
3K3
1K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
R6
R8
R9
R10
R21
R36
R37
R45
R95
R100
R108
R113
R116
R117
R150
R151
R152
R153
R154
R155
R156
R157
R158
R159
R163
R11
R12
R38
R13
R14
R19
R20
R22
R43
R44
R46
R47
R87
R102
R131
R132
R133
R134
R164
R165
R166
R167
R168
R169
R170
R171
R172
R173
R174
R175
R176
Description
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
22R
22R
22R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
100R
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 117
Component list
Pag. 118
Ref.
R177
R178
R179
R180
R181
R182
R183
R15
R16
R17
R18
R23
R24
R25
R26
R39
R40
R41
R42
R48
R49
R50
R69
R70
R71
R72
R73
R74
R75
R76
R77
R78
R79
R80
R81
R82
R83
R84
R88
R92
R93
R94
R27
R28
R29
R30
R31
R51
R52
R53
R54
R55
R32
R34
R67
R101
Description
100R
100R
100R
100R
100R
100R
100R
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
2K
680R
680R
680R
680R
680R
680R
680R
680R
680R
680R
2K2
2K2
20K
20K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
R109
R149
R86
R89
R107
R111
R112
R114
R115
R118
R135
R136
R137
R138
R162
R186
R191
R190
TP1
TP2
U1
U2
U9
U12
U3
U4
U26
U5
U6
U7
U8
U10
U11
U13
U14
U15
U16
U17
U20
U30
U18
U19
U21
U22
U23
U24
U25
U27
U28
U29
U32
U31
U33
U34
U35
Y1
Description
20K
20K
12K
511K
47K
1.82K
1.82K
220K
470K
82K
470R
470R
470R
470R
470R
470R
4K7
4K7
CONN PLUG 1
CONN PLUG 1
TD62083AF
74HC273M
74HC273M
74HC273M
74HC541M
74HC541M
74HC541M
74HC245M
MS6M8512
AM29F040
LM340S-5
74HC138M
LM7301BIM5
74HC04M
AT28HC64B-70JC
LMC7101BIM5
LMC7101BIM5
LMC7101BIM5
LMC7101BIM5
LMC7101BIM5
TLV5620I
D70320L-8
CD4051M
CD4051M
CD4051M
CD4051M
CD4051M
MAX691ACSE
PALCE16V8Q-15JC/4
TLV2548I
MAX485
MAX485
TLC5628DW
TLC5628CN
74HC540
16MHZ
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 119
Pag. 120
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
C107
100nF
+12
R1
1K
BIAS 6
BIAS 7
BIAS 7
BIAS 8
BIAS 8
BIAS 9
BIAS 9
BIAS 10
BIAS 10
C1
1nF
C96
100nF
+12
+
-
U23
LM7301/SO
+ SM/SOT23-5
L3
R3
1K
100uH
C3
1nF
C105
100nF
-12
C78
100nF
+12
VBias L
BIAS 6
100uH
C108
100nF
-12
VBias L
L1
U25
LM7301/SO
+ SM/SOT23-5
+
-
R5
1K
U16
LM7301/SO
+ SOG.050/14/WG.244/L.325L4
C5
1nF
C79
100nF
-12
100uH
C59
100nF
+12
L16
R25
1K
U11
LM7301/SO
+ SM/SOT23-5
C22
1nF
C69
100nF
-12
100uH
C54
100nF
+12
L21
R32
1K
U7
LM7301/SO
+ SM/SOT23-5
C58
100nF
-12
100uH
C46
1nF
Title:
Board Code:
E2K 5A000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 125
+12
R42
1K
5
3
+
-
U15
LM7301/SO
+ SM/SOT23-5
BIAS 2
BIAS 2
BIAS 3
BIAS 3
BIAS 4
BIAS 4
BIAS 5
BIAS 5
L20
R31
1K
100uH
C45
1nF
C68
100nF
-12
C95
100nF
+12
+
-
U20
LM7301/SO
+ SM/SOT23-5
L15
R24
1K
100uH
C21
1nF
C94
100nF
-12
C106
100nF
+12
+
-
U24
LM7301/SO
+ SM/SOT23-5
L14
R4
1K
100uH
C4
1nF
C104
100nF
-12
C110
100nF
+12
+
-
U26
LM7301/SO
+ SM/SOT23-5
L2
R2
1K
-12
BIAS 1
100uH
C77
100nF
+12
VBias R
BIAS 1
C53
1nF
C57
100nF
-12
VBias R
L22
U9
LM7301/SO
+ SM/SOT23-5
100uH
C2
1nF
C109
100nF
Title:
Board Code:
E2K 5A000_1
Pag. 126
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
TP2
R12
1
+12
R27
1M
100uH
3
+12
R26
REF_PWR
REF_PWR
AI_REF_PWR
AI_REF_PWR
1K
10K
C29
1nF
J3
RV2
10K
3
4
3
2
1
C25
100nF
100uH
3
R14
1
R28
470K
U3
LMC7101BI
+
1
R29
C13
1nF
10K
1nF
+12
L6
TP3
C23
f -3dB = 16KHz
R11
10K
C14
1nF
CON4
R13
47R
R10
C12
1nF
10K
U2
LMC7101BI
+
L5
C24
100nF
FWD_PWR
FWD_PWR
AI_FWD_PWR
AI_FWD_PWR
R16
1K
10K
C27
1nF
RV3
10K
C26
R15
10K
L19
+12
100uH
J2
2
1
C10
1nF
+
5
CON2
1nF
f -3dB = 16KHz
C50
100nF
U1
LMC7101BI
+
R9
R8
1K
AI_INPUT_PWR
220K
AI_INPUT_PWR
C31
1nF
R6
470K
RV1
10K
3
C11
100nF
R7
22K
Title:
Board Code:
E2K 5A000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 127
L12
1
2
3
4
CON4
R23
1K
+12
C41
100nF
RFC
C20
1nF
R22
2.2M
L11
J7
RFC
C19
1nF
R39
1K13
U6
LMC7101BI
+ SM/SOT23-5
AI_TEMP1
R40
10.2K
C32
1nF
C42
1uF
C43
100nF
1
2
3
4
CON4
R19
1K
L8
+12
RFC
L7
3
RFC
C15
1nF
C35
100nF
U4
LMC7101BI
+ SM/SOT23-5
AI_TEMP2
- R34
10.2K
R35
1K
1
2
3
4
C34
C37
1uF
C36
100nF
L10
AI_TEMP2
1nF
R33
1K13
J6
Fp=1.75Hz
R18
2.2M
C16
1nF
J5
AI_TEMP1
R41
1K
R21
1K
+12
Fp=1.75Hz
C38
100nF
RFC
C18
1nF
R20
2.2M
L9
CON4
RFC
C17
1nF
U5
LMC7101BI
+ SM/SOT23-5
AI_TEMP3
- R37
10.2K
R38
1K
AI_TEMP3
C33
1nF
R36
1K13
C40
1uF
C39
100nF
Fp=1.75Hz
Title:
Board Code:
E2K 5A000_1
Pag. 128
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C12
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C26
C27
C28
C29
C30
C31
C32
C33
C34
C44
C45
C46
C48
C51
C52
C53
C65
C75
C81
C82
C83
C84
C85
C86
C87
C88
C99
C102
C103
C11
C24
C25
C35
Description
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
1nF
100nF
100nF
100nF
100nF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 129
Component list
Ref.
C36
C38
C39
C41
C43
C47
C50
C54
C57
C58
C59
C60
C62
C63
C67
C68
C69
C70
C71
C72
C73
C74
C76
C77
C78
C79
C89
C90
C92
C94
C95
C96
C97
C98
C100
C101
C104
C105
C106
C107
C108
C109
C110
C37
C40
C42
C49
C91
C55
C56
C66
C93
C111
C112
C61
Pag. 130
Description
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
1uF
1uF
1uF
1uF
1uF
100uF 25V
100uF 25V
100uF 25V
100uF 25V
100uF 25V
100uF 25V
10uF
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C80
C64
D1
D2
D4
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D3
D5
D6
H1
H2
H3
H4
H5
H6
J1
J3
J5
J6
J7
J8
J2
J4
J9
J10
J11
J12
J13
L1
L2
L3
L4
L5
L6
L13
L14
L15
L16
L17
L18
L19
L20
L21
L22
L7
L8
Description
10uF
47nF
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
PMLL4148
ZRB500F
9.1V
LED
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
CON4
CON4
CON4
CON4
CON4
CON2
CON2
CON20AP
CONN PCB 5
CONN PCB 5
CON10AP
CON10AP
CON10AP
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
100uH
RFC
RFC
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 131
Component list
Ref.
L9
L10
L11
L12
Q1
Q2
Q4
Q3
Q5
RV1
RV2
RV3
RV4
RV5
R11
R12
R14
R15
R17
R26
R29
R30
R43
R56
R60
R69
R70
R71
R72
R73
R74
R75
R79
R80
R84
R87
R88
R89
R92
R94
R96
R97
R1
R2
R3
R4
R5
R9
R10
R16
R19
R21
R23
R24
R25
Pag. 132
Description
RFC
RFC
RFC
RFC
BC856
BC856
BC856
BCV62
BC846BL
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
10K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
1K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
R31
R32
R35
R38
R41
R42
R55
R58
R95
R6
R28
R82
R7
R59
R8
R13
R18
R20
R22
R27
R33
R36
R39
R34
R37
R40
R44
R45
R62
R63
R81
R46
R47
R48
R49
R50
R53
R54
R83
R90
R91
R51
R52
R86
R93
R57
R61
R64
R67
R68
R65
R66
R76
R77
R78
Description
1K
1K
1K
1K
1K
1K
1k
1K
1K
470K
470K
22K
22K
220K
220K
47R
2.2M
2.2M
2.2M
1M
1K13
1K13
1K13
10.2K
10.2K
10.2K
2.21K
2.21K
2.21K
2.21K
1.2K
1.2K
4.7K
4.7K
4.7K
4.7K
4.7k
4.7k
4.7K
4.7K
4.7K
47K
100R
100R
100R
6.8K
390K
470R
470R
470R
0R
9.09K
5.6K
8.2K
33K
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 133
Component list
Ref.
R85
R98
R99
S1
TP1
TP2
TP3
TP4
TP5
TP6
TP7
TP8
TP9
U1
U2
U3
U4
U5
U6
U8
U17
U18
U19
U7
U9
U10
U11
U12
U13
U15
U16
U20
U21
U22
U23
U24
U25
U26
U14
Pag. 134
Description
2.2K
820R
820R
SW PUSHBUTTON
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
CONN PLUG 1
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
LM7301/SO
4093
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Title:
CURRENT SENSOR
Board Code:
E2K 3A000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 135
Pag. 136
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C1
C2
C3
C4
C13
C14
C15
C16
C17
C18
C19
C20
C21
C22
C23
C5
C6
C7
C8
C9
C10
C12
C11
C24
C25
C26
C27
C28
C29
C30
C31
D1
H1
H2
H3
H4
H5
H6
H7
H8
J2
J1
PWR1
Q1
Q2
Q3
Q4
R1
R2
R3
R4
R5
R6
R7
R8
Description
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
33uF 25V
33uF 25V
100nF 63V
100nF 63V
100nF 63V
100nF 63V
10nF 63V
10nF 63V
100nF
100nF
100nF
100nF
100nF
100nF
100nF
100nF
15V
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
HOLE3.5MM
CON10AP
CON10AP
NME1212S
BSP316
BSP316
BSP316
BSP316
0.006R
0.006R
0.006R
0.006R
47R
47R
47R
47R
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 139
Component list
Ref.
R9
R10
R11
R12
R13
R14
R15
R16
R17
U1
U2
U3
U4
Pag. 140
Description
47R
47R
47R
47R
1K
1K
1K
1K
100R
LMC7101BI
LMC7101BI
LMC7101BI
LMC7101BI
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Title:
KEYBOARD
Board Code:
E2K 8A000_1
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 141
Title:
Pag. 142
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
DSW7
DSW6
DSW5
DSW4
DSW3
DSW2
DSW1
DSW0
DL7
DL6
DL5
DL4
DL3
DL2
DL1
DL0
SW-ARR.DOWN
SW-ARR.RIGHT
SW-SEL
SW-RESET
SW-ST.BY
SW-ENTER
SW-ARR.UP
SW-ARR.LEFT
Board Code:
H2
HOLE3.2MM
H1
HOLE3.2MM
HOLE3.2MM
H3
E2K 8A000_1
HOLE3.2MM
H4
J1
1
2
3
4
5
6
7
8
Model:
Sheet
E2000
of
16
15
14
13
12
11
10
9
SW DIP-8/SM
SW1
CON2
1
2
J2
DL2
DL0
DL3
LED GR 3mm
MAINS
DL3
LED YE 3mm
ST.BY
DL4
DL5
LED HLMP2350
FAILURE
DL2
DL1
LED HLMP2550
ON AIR
DL1
DL4
DL5
DL6
DL7
SEL
ENTER
ST.BY
RESET
ARR.UP
ARR.DOWN
ARR.LEFT
1
4
SWP2
2
3
ARR.RIGHT
1
2
4
3
MICRO-COSMOS
SWP1
1
2
4
3
MICRO-COSMOS
SWP3
1
2
4
3
MICRO-COSMOS
SWP6
1
2
4
3
MICRO-COSMOS
SWP5
1
2
4
3
MICRO-COSMOS
SWP8
1
2
4
3
MICRO-COSMOS
SWP7
1
2
4
3
MICRO-COSMOS
SWP4
MICRO-COSMOS
SW-ARR.RIGHT
SW-ARR.LEFT
SW-ARR.DOWN
SW-ARR.UP
SW-RESET
SW-ST.BY
SW-ENTER
SW-SEL
Website WWW.ELENOS.COM
KEYBOARD
Rev
Approved : A.Giovannelli
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
DL1
DL2
DL3
DL4
DL5
H1
H2
H3
H4
J1
J2
SWP1
SWP2
SWP3
SWP4
SWP5
SWP6
SWP7
SWP8
SW1
Description
LED HLMP2550
LED HLMP2350
LED GR 3mm
LED YE 3mm
LED GR/RED 3mm
HOLE3.2MM
HOLE3.2MM
HOLE3.2MM
HOLE3.2MM
STRIP FEMALE 2.54 RIGHT 27P
CON2
MICRO-COSMOS
MICRO-COSMOS
MICRO-COSMOS
MICRO-COSMOS
MICRO-COSMOS
MICRO-COSMOS
MICRO-COSMOS
MICRO-COSMOS
SW DIP-8/SM
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 143
Pag. 144
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Title:
DIRECTIONAL COUPLER
Board Code:
E2K 0A000_0
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 145
C7
100nF
4 HEADER
4K7
100K NTC
R13
ntcb
100K
4n7
C1b
C3b
HSMS2850
USCITA RF
R1b
56
47pF
R2b
R1B1
1K2
D1
500
R11b
NULL
REF
NULL
0 dBm
J1
BNC
Lx
6 x 0.4 D 2
RF SAMPLE
DIR
500
R11a
C1
10K
R3B1
-
100nF
AR2
C3
4K7
100K NTC
R12
ntc
100K
4n7
47pF
C3a
HSMS2850
56
C1a
R2a
R2
1K2
D1a
R1a
4n7
100
R6
LMC7101BI
4n7
100nF
AR1
C4
R3
C5
10K
LMC7101BI
R5
100
C6
100nF
4
3
2
1
JP1
Title:
DIRECTIONAL COUPLER
Board Code:
E2K 0A000_0
Pag. 146
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
AR2
AR1
C1b
C1a
C1
C5
C3
C4
C6
C7
C3b
C3a
D1
D1a
JP1
J1
Lx
R2b
R2a
R1B1
R2
R3
R3B1
R5
R6
R1b
R1a
R11b
R11a
R12
R13
ntcb
ntc
Description
LMC7101BI
LMC7101BI
4n7
4n7
4n7
4n7
100nF
100nF
100nF
100nF
47pF
47pF
HSMS2850
HSMS2850
4 HEADER
BNC
6 x 0.4 D 2
100K
100K
1K2
1K2
10K
10K
100
100
56
56
500
500
4K7
4K7
100K NTC
100K NTC
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 147
Pag. 148
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
J2
/DI_ENABLE
/DI_TX_OFF
DI_COMMON
DO_ON
DO_FAILURE
9
7
5
3
1
+
+
+
+
+
10
8
6
4
2
+
+
+
+
+
/DI_TX_ON
/DI_RESET
DO_COMMON
DO_ON_AIR
DO_-3dB
CON10AP
J1
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
/DI_TX_ON
/DI_TX_OFF
/DI_RESET
/DI_ENABLE
DI_COMMON
DO_ON
DO_ON_AIR
DO_FAILURE
DO_-3dB
DO_COMMON
CONN PCB 10
H5
H1
HOLE3.2MM
HOLE3.2MM
Title:
USER INTERFACE
Board Code:
E2K 4A000_0
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 149
Component list
Ref.
H1
H5
J1
J2
Pag. 150
Description
HOLE3.2MM
HOLE3.2MM
CONN PCB 10
CON10AP
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
L1
100nH
C1
C2
10uF
100nF
L2
U1
LM35 DZ
1
2
3
4
100nH
+V
OUT
GND
J1
CON4
R1
68
C4
100nF
C3
100nF
Title:
THERMAL PROBE
Board Code:
E2K 7A000_0
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 151
Component list
Ref.
C1
C3
C2
J1
L2
L1
R1
U1
Pag. 152
Description
10uF
100nF
100nF
CON4
100nH
100nH
68
LM35 DZ
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
POSITIVE
R1
18k
TO
CAPACITORS
2
1
C1
47nF
CN1
NEGATIVE
Title:
VOLTAGE PROBE
Board Code:
E2K 1A000_0
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Model:
Rev
E2000
Approved : A.Giovannelli
Sheet
of
Pag. 153
Component list
Ref.
C1
J22
J22
J23
R1
Pag. 154
Description
47nF
CN1
POSITIVE
NEGATIVE
18k
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
C17
C18
C19
C18
C19
L2
R9
50 Ohm
C13
C13
C12
C15
C14
C11
L2
R9
C12
C15
C14
50 Ohm
C11
R8
25 Ohm
R2
R3
R6
+VDS
L1
R7
TF1
C9
R4
C10
R5
C6
D1
R1
GATE BIAS
C3
C4
VOLTAGE
C2
C1
P1
25 Ohm
+VDS
2PCB0252_1
C7
C8
R8
25 Ohm
U1
C16
C17
25 Ohm
L1
U1
C7
R2
C8
R3
C6
D1
R1
GATE BIAS
C4
C3
VOLTAGE
C5
C5
P1
C9
C10
R4
R5
R7
2PCB0252_1
C16
TF1
R6
C2
C1
Title:
POWER AMPLIFIER
Rev
E2000
Board Code:
Model:
Approved : A.Giovannelli
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Sheet
of
Pag. 155
470pF
470pF
C16
470pF
50 ohm
25 ohm
C10
10nF
C9
R6
5.6K
C1
56pF
TF1
R1
10nF
C3
10nF
P1
C2
R4
10
R3
10
R2
10
10K
1N4148
D1
20K
R5
10
10nF
C8
10nF
C7
10nF
10nF
C4
C6
10nF
C5
10nF
R7
22
U1
BLF278
L1
R8
10
25 ohm
470pF
C15
470pF
C11
10
R9
L2
430nH
C12
470pF
C17
C19
C18
470pF
C14
470pF
C13
+VDS
47uF 63V
Title:
Pag. 156
POWER AMPLIFIER
Rev
E2000
Board Code:
Model:
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Component list
Ref.
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C14
C11
C12
C15
C16
C17
C18
C19
C13
D1
J1
J2
L1
L2
P1
R1
R2
R3
R4
R5
R8
R9
R6
R7
TF1
TF2
TF3
TF4
U1
Description
56pF
10nF
10nF
10nF
10nF
10nF
10nF
10nF
10nF
10nF
470pF
470pF
470pF
470pF
470pF
470pF
470pF
470pF
47uF 63V
1N4148
SMA CS VERT
BNC
IND
430nH
20K
10K
10
10
10
10
10
10
5.6K
22
25 ohm
25 ohm
50 ohm
BLF278
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 157
Pag. 158
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
L1
L2
L3
L4
L5
87nH
169nH
161nH
169nH
87nH
INPUT
OUTPUT
C1
C2
C3
C4
35pF
41pF
41pF
35pF
Title:
Component list
Ref.
C1
C4
C3
C2
L1
L5
L2
L4
L3
E2000
Board Code:
Model:
Approved : A.Giovannelli
Sheet
of
Description
38pF
38pF
70pF
70pF
20nH
20nH
80nH
80nH
74nH
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 159
J10
SMB
Microstrip 90 70.7Ohm
R19
Microstrip 90 70.7Ohm
50R
J9
SMB
R18
Microstrip 90 35 Ohm
Microstrip 90 70.7Ohm
50R
J8
SMB
R17
Microstrip 90 70.7Ohm
50R
J7
SMB
R14
Microstrip 90 70.7Ohm
50R
J4
SMB
R11
Microstrip 90 70.7Ohm
50R
J3
SMB
50R
R12
100R
2PCB0262
Microstrip 90 35 Ohm
Microstrip 90 70.7Ohm
R10
50R
J2
SMB
Microstrip 90 70.7Ohm
R9
50R
R8
J1
SMB
J6
2
1
2PCB0261
R15
100K
C2
4.7nF
R16
50R
J5
SMB
D1
HSMS2850
-34dB
C1
180pF
Microstrip 50 Ohm
R16
68R
Title:
Pag. 160
SPLITTER INPUT
Rev
E2000
Board Code:
Model:
Approved : A.Giovannelli
Sheet
of
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
2PCB0256
Microstrip 75 Ohm
Microstrip 75 Ohm
PORT 1/A
PORT 3/A
R1
100R
R6
R4
100R
100R
PORT 2/A
PORT 4/A
Microstrip 75 Ohm
Microstrip 75 Ohm
RG302 90
RG302 90
R3
100R
AL FILTRO PASSABASSO
RG302 90
RG302 90
RG302 90
RG302 90
Microstrip 75 Ohm
Microstrip 75 Ohm
PORT 1/B
PORT 3/B
R2
100R
R7
100R
R5
100R
2PCB0256
Microstrip 75 Ohm
2PCB0256
PORT 2/B
PORT 4/B
Microstrip 75 Ohm
Title:
OUTPUT COMBINER
Rev
E2000
Board Code:
Model:
Approved : A.Giovannelli
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Sheet
of
Pag. 161
Pag. 162
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
6.1.
Air filter replacement
The equipment features a filter placed in front of the air intake of the fans to
prevent the ingress of dust, small insects or other foreign bodies which could be damaging
to the operation of the equipment.
The air filter should be replaced at least once a year in normal operating conditions.
REPLACING THE AIR FILTER
Disconnect the equipment from the electrical supply
Remove the front panel (see the fixing points in the diagram below)
Replace the dirty air filter with a clean one
Replace the front panel
N.B.
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 163
Pag. 164
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Operating band:
Output power:
Driver power:
Gain:
Level of harmonics and spurious signals:
Asynchronous AM:
Fast SWR intervention threshold:
SWR limiter threshold:
Efficiency:
Temperature:
POWER SUPPLY
110V, 220V, 380V three-phase-single phase 50-60Hz
>90%
220V, 380V three-phase 50-60Hz
88%
RF SECTION
GENERAL CHARACTERISTICS
Humidity:
Altitude:
Weight:
Dimensions:
Rack units:
Cooling:
(operating) 0 +45 C
(storage) -20 +50 C
(operating) 95% @ 40C
(storage) 90% @ 65C
(operating) > 4600 m s.l.m.
(storage) > 15000 m s.l.m.
55Kg DR version (switching power supply)
103Kg TR version (linear power supply)
31 x 41.3 x 79 cm
7
forced ventilation
IEE485, Analog monitor, RF output monitor and RF input connecting cables must be less than 1 m. long, while
AC power input/output port cable must be less than 3 m. long.
Ufficio Tecnico TEL: +39 0532 829 965 - FAX: +39 0532 829 177
E-Mail: support@elenos.com
Pag. 165