1 CME Single Configuration Operation Guide

This section describes data configuration operations. The CME allows you to search for
configuration objects, configure a single object or configure objects in batches, and perform
other basic operations in the data configuration window.

Searching for and Configuring Configuration Objects


Figure 1-1 shows the window for searching for NE managed objects (MOs) and configuring
such objects.

Figure 1-1 Window for searching for and configuring configuration objects

1. Select an object view from the left pane of the planned data area, for example, base
station.
2. In area 1, select the base station controller, base station, or cell to which a
configuration object belongs.
3. In area 2, type the name of a configuration object on the Search tab page, for example,
GCELL.
4. In the Object Name column of area 3, double-click the required configuration object.
all parameters for the configuration object are displayed in area 4.
5. Configure the data in area 4 and area 5.

TIP:
To obtain parameter description for a configuration object, press F1 in area 4 to invoke the Help of the
parameters for the configuration object.

Click

to hide or show area 5 that vertically displays a single record.

Operations for Configuring Multiple Records


The data configuration window for objects consists of the window for multiple records and for a
single record. Figure 1-1 shows the window for multiple records in area 4 and the window for a
single record in area 5.
Table 1-1 describes the operations you can perform in area 4 for configuring multiple records.

Table 1-1 Data configuration operations


Operation

Description

Add a
, add a record of object information, and click
configuration Click
object.
information.
is displayed in front of the added record.

to save the

NOTE:
If the parameter value is in hexadecimal format, type H'****. For example, H'1214.

After configuring some mandatory parameters, you can select Auto Commit in the
upper right part. The CME automatically saves the configured data on the client
when you view other data. To save all the configured data to the planned data area,
click

after configuring all mandatory parameters.

Modify a
single
parameter.

Select the parameter you want to modify, type a new value, and click

Modify
parameters
in batches.

Click
in the upper right part of the configuration window. The CME displays
Bulk Modification Wizard. Modify parameters in batches according to the
wizard.

can also click the blank area on the left of


displayed on the left of the modified record.

to save the modification.

Delete a
configuration Select one or more records you want to delete, and click
object.

is

After you delete an existing record,

After you delete a new record, the record is not displayed in the window.

Update
configuration Click
data.

. You

is displayed on the left of the record.

to update the configuration data in the active window.

TIP:

After data is changed due to data import or other interlocked modification, you
can update data if the data in the active data configuration window is not
automatically updated.

View
Some parameter names are long and the CME displays only part of the
parameter
parameter names. To view a complete parameter name, do as follows:
names
displayed
Place the cursor on the parameter name. The CME automatically displays the full
incompletely.
name of the parameter.

Export data.

Copy data.

Sort data.

Filter data.

Widen the column of the table by dragging the separation line between two columns
until the full parameter name can be displayed.

Double-click the separation line between two columns. The CME automatically
adjusts the column width to display the parameter names fully.

Right-click a data record and choose Export All Data of Current NE Version from
the shortcut menu. The CME exports all the NE data in the active current or planned
data area that is of the same version as the selected data to a file.

In the data configuration area, select a data record, and click


exports all the data of the object under the NE to a file.

. The CME

Right-click the record you want to copy and choose one of the following items
as required:

Copy Record: copies existing data in the selected record and pastes the data to the
added record.

Copy Cell: copies data in the selected cell and pastes the data to another file.

Copy Row: copies all data in the selected row and pastes the data to another file.

Copy Column: copies all data in the column where the selected cell locates and
pastes the data to another file.

Copy Table: copies all data in the selected table and pastes the data to another file.

Sort data in the current window in ascending or descending order.

1. Click

next to the name of the data to be sorted to change it into

2. Click

. The CME sorts the data in ascending or descending order.

The objects that meet the entered filter criteria can be quickly located.

1. Click

next to the parameter name.

2. Select filter criteria from the drop-down list.

Select a single filter criterion: Select a parameter value from the drop-down list. The
CME displays the data that matches the value.

Select multiple filter criteria: Select Custom from the drop-down list. Then, select
multiple criteria in the displayed dialog box. The CME displays the data that meets
these filter criteria.

CAUTION:
The function applies only to the data consisting of numerals, characters, or a
combination of them.

Hide
parameters.

Characters are case insensitive.

Hide the parameters that you do not need to view in the window.

1. Right-click in the data configuration area and choose Select Columns


to Display from the shortcut menu.
2. Clear the parameters that are not required.

Collect
statistics
about
records.

Right-click in the data configuration area and choose Record Statistics from
the shortcut menu.

Locate the
Locate the column for a parameter according to the parameter name. You can
column for a
use this function when the scroll bar is displayed for additional parameters that
parameter.
do not fit into the space in the window.

1. Right-click in the data configuration area and choose Locate Column


from the shortcut menu.
2. In the displayed dialog box, type the name of the parameter that you
want to locate and click OK.

Operations for Configuring a Single Record


In the single record configuration area, you can only modify a single parameter, modify
parameters in batches, update configuration data, and export data by click
Table 1-1.

as described in

Você também pode gostar