Você está na página 1de 2

PowerPac Universal Power Supply

Sole Source Specifications

Output range (programmable)


Volts 10-500 V in 1 volt steps
Current 0.01-2.5 A in 0.001 A steps
Power 1-500 W in 1 watt steps
Type of output Constant voltage, constant current, or constant power with
automatic crossover
Timer 1 min – 99 hr 59 min
Volt-hour control Up to 99,000 V-hr
Pause/resume function Yes
Programmable methods Stores 9 methods, each with up to 9 steps
Editing on the fly Yes
Display 128 x 64 pixel, backlit, graphics LCD
Viewing angle adjustment Yes
Automatic recovery after power Yes
failure
Safety features No load detection; sudden load change detection, ground leak
detection, overvoltage detection, overload/short circuit protection,
input line protection, auto power-up after power failure
Input protection Fuses
Operating conditions 0-40 °C; 0-95% humidity
Dimensions (WXDXH) 27.5 X 34 X 10 cm
Stackable Yes
# output jacks 4 sets in parallel
Regulatory EN-61010, CE
Input power (actual) Universal 90-120 or 198-264 VAC, 50/60 Hz, autoswitching
Cold room compatible Yes
Weight 2.5 kg
Warranty 3 year

1. Output capability of 500 V, 2.5 A, and 500 W for compatibility with the broadest range of applications.
2. Innovative wireless data transfer to organize, display, print, andalyze, export, and annotate run data
to a PDA and a PC.
3. IQ/OQ to support GLP- and FDA-regulated environments with IQ/OQ protocols and test box.
4. Run duration can be programmed for either continuous or timed control (maximum of 99 hr 59 min)
or volt-hour control up to 99,000 V-hr.
5. Autoswitching input power of 100-120/220-240 VAC, 50 or 60 Hz for portability around the world.
6. Stores up to 9 methods, each with up to 9 steps, for reproducibility and ease of use.
7. Run parameters can be programmed for constant voltage, constant current, or
constant power control with automatic crossover.
8. Four sets of color-coded power output jacks, wired in parallel for simultaneous operation
of four (identical) electrophoresis cells.
9. The PowerPac Universal power supply can automatically resume and complete
an electrophoresis run in the event of a power failure.

1 of 2 05/25/04 Rev. A
10. Viewing angle adjustment for optimal viewing from a lab bench or shelf.
11. Overload/short circuit detection with automatic shutdown to protect the power supply
from damage incurred by incorrect usage.
12. Sudden load change detection with automatic shutdown to protect the user
from potential electric shock hazard.
13. Certified to the international IEC 1010-1 safety standard. Conforms to CE standards
for Emissions and Immunity class A, tested at 120/230V. TÜV EMC certification.
14. Cold-room compatible.
15. Stackable design to save bench space.

2 of 2 05/25/04 Rev. A

Você também pode gostar