Installation
Node B
IMN:NB-440
A50016-G5000-C229-5-7631
ND-57356-701(E)-05
IMN:NB-440
Installation
Node B
Trademarks:
All designations used in this document can be trademarks, the use of which by third parties for their
own purposes could violate the rights of their owners.
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
all
Chapter 1 and 3
2.5.5
2.6.10
2.6.12
Issue History
Issue
Number
Date of issue
04/2002
07/2002
10/2002
12/2002
02/2003
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
IMN:NB-440
Installation
Node B
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
Contents
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Purpose of the Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tasks of the Node B Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System Operating Bands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Prerequisites. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Handling of the Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ancillary Material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data of NB-440. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Interfaces of the NB-440. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
11
11
12
12
13
13
14
14
14
2
2.1
2.2
2.3
2.4
2.4.1
2.5
2.5.1
2.5.2
2.5.2.1
2.5.2.2
2.5.3
2.5.4
2.5.5
2.6
2.6.1
2.6.2
2.6.3
2.6.3.1
2.6.3.2
2.6.3.3
2.6.4
2.6.5
2.6.6
2.6.7
2.6.8
2.6.9
2.6.9.1
2.6.10
2.6.10.1
2.6.10.2
2.6.11
NB-440 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Position in the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Construction View of NB-440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unpacking the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unpacking the rack out the transportation crate . . . . . . . . . . . . . . . . . . . . .
Unpacking the rack out the wrapping foil cover . . . . . . . . . . . . . . . . . . . . .
Devices Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setup of Earthquake Mounting Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
External Cabling Activities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ground and Power Supply Connections -48 V DC . . . . . . . . . . . . . . . . . . .
Iub-Interface - Link Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Iub-Interface for 100/120 Ohm Cable Impedance. . . . . . . . . . . . . . . . . . . .
Iub-Interface for 75 Ohm Cable Impedance . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring Interfaces of the Iub interfaces . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm Collection Terminal - external Signal Sensors . . . . . . . . . . . . . . . . .
Installation of the Mounting Kit OPEXAL . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm Collection Terminal ACTC - internal Alarms . . . . . . . . . . . . . . . . . . .
Local Maintenance Terminal (LMT) Interface . . . . . . . . . . . . . . . . . . . . . . .
Connection of External Reset Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Antenna Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation of Antenna Jumper Cables . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation of the Tower Mounted Amplifiers . . . . . . . . . . . . . . . . . . . . . . .
Pole Mounting with Hose Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Mounting of TMAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation of the Top Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
15
15
16
16
18
19
19
20
20
22
22
23
27
29
29
31
33
33
35
36
37
39
42
43
44
45
45
51
54
56
57
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
IMN:NB-440
Installation
Node B
2.6.12
2.7
3
3.1
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Checklist for NB-440 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
Illustrations
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
1.1
1.2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
2.10
2.11
2.12
2.13
2.14
2.15
2.16
2.17
2.18
2.19
2.20
2.21
2.22
2.23
2.24
2.25
2.26
2.27
2.28
2.29
2.30
2.31
2.32
2.33
2.34
2.35
2.36
2.37
2.38
2.39
2.40
2.41
ESD Symbol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Press-stud for ESD wrist-strap connection . . . . . . . . . . . . . . . . . . . . . .
Position of a Node B within the System . . . . . . . . . . . . . . . . . . . . . . . . .
Site configuration NB-440 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fully equipped NB-440 rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ShockwatchTM-label and TIP (N) TELLTM-label . . . . . . . . . . . . . . . . . .
Removal of the straps, opening of the top cover . . . . . . . . . . . . . . . . . .
Removal of the packing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Opening of the PE-wrap, lifting straps around the rack . . . . . . . . . . . . .
Foil- transportation packing of NB-440 . . . . . . . . . . . . . . . . . . . . . . . . .
Opening of rack door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removal of top cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guideline for crane transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Space necessary for installation of NB-440 . . . . . . . . . . . . . . . . . . . . . .
Removal of fastening claws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adjusting of rack foot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting bracket for fixing to wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts of the earthquake kit S3086-K4119-X . . . . . . . . . . . . . . . . . . . . .
Double claw for the rear feet in mounted position . . . . . . . . . . . . . . . . .
Claws for the front feet before fixing . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drilling sketch for earthquake mounting kit . . . . . . . . . . . . . . . . . . . . . .
Interfaces on EMI Panel of the NB-440 . . . . . . . . . . . . . . . . . . . . . . . . .
Locations of connection points for external cables . . . . . . . . . . . . . . . .
Ground and DC mains connections of the NB-440 . . . . . . . . . . . . . . . .
DC mains terminal block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of the grounding wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preparation of twisted pair cables, 120 Ohm impedance . . . . . . . . . . .
Routing of Iub-cable (example with OVPTE1J1SF). . . . . . . . . . . . . . . .
Pinning Iub interface at OVPTE1J1SF / IUBCONSFV1. . . . . . . . . . . . .
Iub interface with coaxial connectors (example with OVPTE1CF). . . . .
Iub line connectors of OVPTE1CF / IUBCONCFV1. . . . . . . . . . . . . . . .
Pinning of the monitoring interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terminal numbering of the ACTM . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents of the MK:OPEXAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drilling sketch for MK:OPEXAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall mounted MK:OPEXAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Routing of external alarm cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connector arrangement at ACTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of external reset line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Example for cell numbering (top view from the antenna pole). . . . . . . .
Tools for jumper fabrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts of the connector unit kit (example) . . . . . . . . . . . . . . . . . . . . . . . .
Using the trimming tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
12
12
15
16
18
20
20
21
21
22
23
23
24
24
25
25
26
27
28
28
28
29
30
31
32
32
33
34
34
35
35
36
38
39
40
41
41
42
44
45
46
46
47
IMN:NB-440
Installation
Node B
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
Fig.
2.42
2.43
2.44
2.45
2.46
2.47
2.48
2.49
2.50
2.51
2.52
2.53
2.54
2.55
2.56
2.57
2.58
2.59
2.60
2.61
2.62
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
Tables
Tab.
Tab.
Tab.
Tab.
Tab.
Tab.
Tab.
Tab.
Tab.
Tab.
1.1
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3.1
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
14
36
37
38
39
42
42
43
59
61
IMN:NB-440
10
Installation
Node B
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
1 Introduction
!
1.1
Important!
The declaration of CE conformity for the product is fulfilled if the setup and wiring are
carried out as described in the manual and the documents contained therein, such as
installation instructions, cable lists, etc. Project-specific documentation should be taken
into account as appropriate. Deviations from specifications or unauthorized changes in
the setup, such as the use of cable types with less shielding, can lead to a violation of
CE safety requirements. In such cases, the declaration of conformity is rendered void.
The responsibility for the resulting problems passes to the individual who caused the deviation.
1.2
1.3
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
11
IMN:NB-440
Installation
Node B
1.4
Installation Prerequisites
It is required that the installer pays attention to all relevant national EMC standards.
EMF (electromagnetic fields) standard relevant for the choice of the antenna, the
placement of the antennas
and the max. output power of the Node B (cell coverage).
Use the correct material as described in this manual.
Installation according to the standards EN 50310 or ETS 300253, EN 50154 and the
statements in this manual.
The other equipment on site have to fulfill the relevant safety- and EMC standards
and must provide interfaces for connecting of external cables conformable to EMC
instructions.
The installation staff must have a basic knowledge of the relevant standards.
The installation manual should be available for staff on site.
1.5
Fig. 1.1
ESD Symbol
Fig. 1.2
12
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
1.6
!
Safety Instructions
Pay attention to the following safety instructions on high voltage and high current:
Persons other than the maintenance personnel must not touch the devices inside the
AC-Distribution. The AC-Distribution involves a high voltage and high current. Touching
it can lead to an electrical shock or accident.
Make sure not to touch parts of the Node B that contains components with high voltage
or current. An inadvertent contact with any of these components can cause injury, death,
and/or damage to the system.
Be sure to provide grounding where required. A failure to do so can lead to a system
failure or electrical shock at the time of lightning.
When measuring voltage or current, take adequate insulating measures, such as covering or winding the superfluous parts of the measuring terminal and tools with insulating
tape. Allowing the measuring terminal to touch another terminal or a short-circuit caused
by a tool can lead to an electrical shock or accident.
Before making a connection with the DC-PDB, ensure that the power to the main and
battery circuit breaker is OFF. Making a connection with the DC-PDB when the power
is ON can lead to an electrical shock or accident.
Before making a cable connection, be sure to turn the switch on the power distribution
board to OFF. Otherwise, an electrical shock or accident can result.
Before making a cable connection, confirm the electric polarity. If the cable is connected
with wrong polarity, an electrical shock or accident can result.
Make sure to follow the additional safety instructions in this manual.
1.7
Installation Tools
The correct installation is carried out with the aid of the following tools:
Standard toolkit for BSS-installation
Spirit level
Torque spanner for SMC connectors (35 Ncm)
Torque spanner for SMA connectors (100 Ncm)
Screw driver for torx screws T8, T10, T20, T25, T30
Long screw driver for torx screws T30 (length 400 mm)
Engineers spanners open ended for M12, M42 (SW 19, 65 mm)
Ratchet with inserts for nuts M4, M5, M6, M8, M10 (SW 7, 8, 10, 13, 17 mm)
Security torx bit IPR25 (Knrr part no. 4000031 98)
Screw drivers for hexagonal socket screw or hexagonal socket screw key SW 4 mm
Screw driver for slotted screw M3, M4, M5
Screw driver for pozi drive screws M3,M4, M5
A pair of scissors
Stripping knife for RF cables
90 offset screw driver for torx screws T20
Blanket and knee pads (recommended)
Adjuster feed wrench M42 (SW65) (Knrr part no. 01.139.965.7)
Hammer and a suitable piece of wood
Insulated torque wrench for Torx T30 (6 Nm) and an open ended 17mm (20 Nm)
Torque wrench 32 mm (12-35 Nm) for 7/16 connectors
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
13
IMN:NB-440
Installation
Node B
Tool Siemens SNR C39407-A149-A6 (removal of gas filled surge arristors in the
OVPT)
1.8
Ancillary Material
The following ancillary materials are needed :
plumb line
colophony
adhesive tape (yellow/green, green, blue, red, orange, white)
cable fasteners
wire end sleeves for 16 mm and 35 mm2 copper wires
cable lugs M8
wire end sleeves
paint retouch kit (Siemens Serial No. A500-C101-B261)
1.9
1.10
7/16, female
IuB lines
mains input DC
ground
external alarms
LMT
System Reset line
Tab. 1.1
14
Interface
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2 NB-440 Installation
2.1
RNS
Uu interface
Node B
Core Network
RNC
Iub
interface
Iu
interface
mobile
User
Equipment
Fig. 2.1
2.2
Site Requirements
The NB-440 is intended to be installed in a restricted access area.The installation site
must fulfill installation rules according to ETS 300253 or EN 503010 and EN 50174.
The lightning protection measures must be in accordance with IEC 1312 (in the future
series IEC 61024) and IEC 61000-2-5 to achieve a lightning protection zone 1 interface
to the communication equipment.
Prior to the commencement of installation, the construction of the room which the
Node B is to be housed in should be complete and the room in good condition.
If necessary, dry heaters should be setup in the room.
Doors and windows must already have been installed and must be lockable.
Openings in wall or ceiling or floor - if required - must be complete.
The floor coverings must have been laid.
Room lighting and wall sockets must have been installed.
Heating or air-conditioning systems should be ready for operation.
Battery ventilation must be ensured.
Walls and ceilings should have been painted. The room must be clean.
A minimum floor space of 1,10 m x 1,40 m must be provided. These are the dimensions for a minimum installation without the possibility for later extension.
optional cable runways have to be installed first
The floor load of the construction room must exceed of 7000 N/m2.
All installation works of -48 V DC power supply equipment should be finished.
External circuit breakers (125 A, medium response time and a contact separation of
at least 3mm) if there is no DC pole grounded, a two-pole disconnect device is
necessary. They have to be fitted in a power distribution panel for each rack.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
15
IMN:NB-440
Installation
Node B
To prevent subsequent accumulation of dust and dirt, the parts and equipment
units to be installed should be unpacked outside the room (if possible). It is advantageous to install the Node B only after all other installation works to create the required
infrastructure are complete.
2.3
Site Configuration
Operation of the NB-440 requires additional equipment on site:
TX/RX antennas
external alarms**
AC mains
Iub lines
-48 V DC
LE
link equipment
=
DC power supply
(can be NTPM or
microwave)
terrestrial lines
to RNC *
ground bar
ground connection
Fig. 2.2
2.4
16
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
NOTE
All empty slots in a partially equipped shelf must be closed with adequate dummy board
cassettes, so that the air flow inside the rack will not be affected.
Dummy board casettes are available with the dimensions 295 x 20 mm, 295 x 40 mm
and 295 x 60 mm (H x W).
NB-440 is fed by an external -48 V DC source.
The required link equipment for the fixed link to the fixed public telephone network
(can be microwave or NTPM) must find place in a separate shelf on site. Type and layout
of the shelf depends on customer requirements.
For further information about the hardware architecture refer to the Technical Description UTRAN NB-440/441.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
17
IMN:NB-440
Installation
Node B
2.4.1
Rack Layout
The rack allows a minimal configuration with 1 TRX and can be equipped with up to
6 TRX for different cell configurations.
top cover
EMI Panel
FAN#0
FAN#1
A-shelf
LPA#4
DUAMCOF#2
LPA#5
LPA#0
DUAMCOF#0
LPA#1
LPA#2
DUAMCOF#1
LPA#3
document tray
DC Panel
18
...
B-shelf
CH#9
REP#0,1
TRX#0
CH#0
CC#0
Fig. 2.3
...........
TRX#5
FAN#3
FAN#2
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.5
Equipment Delivery
The NB-440 rack is shipped vertically in a wooden crate.
The crate dimensions for the NB-440 are 1600 mm x 800 mm x 650 mm (HxWxD).
Depending on the pre-installed modules inside the racks, the crate can weigh up to
approx. 190 kg.
The delivery position in case of transportation by airplane or at transportation on the
street is horizontally. In this case the NB-440 is mounted on a wooden pallet and is
protected through cardboard corner reinforcement at the edges of rack and by a wrapping foil cover.
The crate or the packing-foil cover have the following information printed on them for
identification of delivery:
destination, customer order number
serial number of rack
gross and net weight, overall dimensions (cm)
symbol or inprint to identify the "Top" and the "Bottom"
delivery papers
Use handling aids (for example: fork-lift truck, goods elevator) for transportation of the
NB-440 from the unloading area into the construction room. A second person is needed
for help. The 4 fastening clamps which are fixing the rack-feet to the bottom of the crate
should be used for fastening the rack to the floor.
!
2.5.1
NOTE
In the case of horizontal transportation, the fixing plates are not used but are always part
of a delivery. Though not needed for horizontal transportation, the claws can be used
for fixing the Rack to the floor after installation.
CAUTION
The rack door must be kept closed during transportation.
Preliminary Checks
The transportation crate of the NB 440 is equipped with a ShockwatchTM -label and a
TIP (N) TELLTM -label. These labels are fixed at the crate for indication of fallover or
strong shocks during the transport from factory to the site.
If the TIP (N) TELLTM arrow is blue, the package has been on the side of tipped over in
transit. Indicates the ShockwatchTM -label red color, the package has been shocked
during the transport.
Check that the delivery packing and labels are in proper condition. If there is obviousdamage due to transportation, unpack the equipment in the presence of an insurance
company representative and promptly claim any damage. Inform the shipper of the
specific damage.
Check whether the package is actually addressed to the site and complete.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
19
IMN:NB-440
Installation
Node B
ShockwatchTM-label
Fig. 2.4
2.5.2
2.5.2.1
!
NOTE
Immediately after unpacking the rack, inspect it for damage and report the extent of
any damage to the transportation company.
unscrew
cut
Fig. 2.5
20
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.
3.
4.
5.
6.
7.
Unscrew the 10 M4 screws on the top of the crate (see Fig. 2.5).
Remove the crates top cover .
Take out the packing material protecting the rack (see Fig. 2.6).
Open and remove the tubular PE-wrap protecting the rack (see Fig. 2.7).
Take out the rack from the crate. Use the straps around the rack.
Lift the rack in vertical position.
Fig. 2.6
cut
Fig. 2.7
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
21
IMN:NB-440
Installation
Node B
2.5.2.2
2
1
Fig. 2.8
CAUTION
Safety gloves and goggles must be worn when cutting the straps.
Pay attention to the tension of the straps. Use only plate shears.
Unpack the rack according to the following instructions and in accordance with the
Fig. 2.8.
1. Cut the two straps (1)
2. Open by cutting the foil along the cardboard corner reinforcement (2) the tubular
PE-wrap protecting and remove it
3. Remove the cardboard reinforcement on the top and from the corners of rack
4. Remove the four fastening claws from the feet of the rack, for further transport to the
installation location as described in chapter 2.5.4.
2.5.3
Devices Unpacking
If neccessary proceed as follows:
1.
2.
3.
4.
22
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.5.4
Rack Installation
Prior to the commencement of rack installation, consult the site documentation
to locate the installation point of the NB-440, the link equipment, power supply unit and
the access of the antenna cables into the construction room.
After that, check the proper installation of the ground bar and the necessary
cable runways.
If the rack must be moved to the final installation position by crane and for later
connection works, it is necessary to remove the top cover of the rack.
CAUTION
Before opening the rack door, take measures to prevent the rack falling over!
Note the accident prevention regulations, when working with a fork lift truck or crane !
Proceed as follows:
3
4
2
1
Fig. 2.9
1. Open the rack-door as shown in the figure above: Slide down the protection cover
(1), push the button behind the cover (2) and flap out the handle (3). Turn the handle
counterclockwise 45 (4).
2. Slide the top cover 20 mm in front direction and lift it up ( see Fig. 2.10.)
3. Disconnect the green/yellow ground wire from the pin inside the top cover.
ground wire
Fig. 2.10
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
23
IMN:NB-440
Installation
Node B
min. 65
Fig. 2.11
The NB-440 are intended for interior installation only so that they should be free from
possible water ingress, frost, tampering and excessive insect attack.
The following recommendations should be considered:
In order to install the NB-440 below a roof or in a room, a minimum height of
1700 mm is required which is also necessary for removing the top.
Installation next to a wall is possible to the left. A minimum distance of 100 mm to be
maintained at the rear. A clearance of 500 mm on the right is needed to open the
rack door. In case of back-to-back installation a distance between the rear panels
of the racks of 200 mm is absolutely required.
The minimum distance to the opposite wall is 750 mm.
It is recommended that an additional working area be considered with an
appropriate emergency exit. The rack has a right hand opening door.
min. distance
for proper air radiation
NB-440
100 mm
600 mm
500 mm
NB-440
1700 mm
(minimum room height)
750 mm
door
Fig. 2.12
24
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
Fig. 2.13 shows the four fastening claws which fix the rack feet to the crate or wooden
pallet during transport. The claws should be used for fixing the NB-440 rack to the floor.
Fig. 2.13
4
3
1
Fig. 2.14
CAUTIONIt is strictly not allowed, to install the NB-440 without fixing to a concrete
foundation or base construction!
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
25
IMN:NB-440
Installation
Node B
Additionally the rack can be affixed to the wall. Mounting brackets (Siemens serial no.
C50300-A204-C156) should be used for the wall fixing.
20
40
100
195
diameter 10
length 20
40
Fig. 2.15
26
CAUTION
When the earthquake mounting kit is used, no additional wall mounting of the
rack is allowed!
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.5.5
Fig. 2.16
Fix the rack to the floor in accordance with Fig. 2.19 in steps as follows:
Mark the positions of the drilling holes in.
Drill at right-angle the holes with 18 mm in diameter and a depth of 98 mm. Dont
pre-drill the holes!
Produce an undercut of the drilling holes: drill the hole to stop and swivel the
jack hammer 3-5 times keeping stop to concrete.
Clean out the drilling holes by blowing or sucking.
Put dowels (3) (e.g. HILTI - M12*73 / 20) into the inserting tool and hammer into each
hole until the sleeve is flush with surface.
Screw the premounted double claw (1) with the rear dowels on the floor with a torque
of 60Nm tight (see Fig. 2.17).
Shift the rack to the appropriate position, so that each of the rear rack feet is placed
in a cutout of the double claw.
Open the rack door.
Insert a claw (2) on each of the front feet and affix them with the M12 bolts to the
steel plugs in front of the rack (see Fig. 2.18).
Tighten the connection with a torque of 60Nm.
See drilling sketch in Fig. 2.19.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
27
IMN:NB-440
Installation
Node B
Fig. 2.18
465
450
600
92.5
Fig. 2.17
485
57.5
Fig. 2.19
28
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.6
2.6.1
6
7
4
1
4 DC terminal
5 ACT
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
29
IMN:NB-440
Installation
Node B
After that all other cables like DC mains, RF cabling or alarm wires can be installed.
The screen of the RF jumpers has to be grounded before entering the rack via
the cable feeding module, see Fig. 2.49.
If cables are fed through coaxial cable access located at the top of the rack at the
front, the screen has to be grounded like all other coaxial cables.
front of rack
NB-440
Fig. 2.21
30
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.6.2
16 mm2
16 mm2
35 mm2
-48 V
125 A
+0V
=
~
connection
to ground
Fig. 2.22
ground bar
power distribution
with circuit breaker
AC mains
The figure above shows the recommended cabling for the power supply and
ground connections. The recommended cable types as shown in the figure above
guarantees the proper function of the NB-440, equipped with up to 6 TRX.
The NB-440 will be powered by -48V DC. A 2-pole terminal block of the MSU, located
in the top of rack, is the connection point for the DC mains wires.
An easily accessible disconnect device is incorporated into the DC mains supply
wiring. To isolate the DC mains supply, a 125 A circuit breaker (medium response time
and a contact separation of at least 3 mm) must be installed in the DC distribution box
for interruption of the -48 V conductor. If there no DC pole grounded, a two-pole
disconnect device is necessary.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
31
IMN:NB-440
Installation
Node B
To connect the NB-440 with the DC mains supply equipment point, proceed with
the following steps:
1. Refer to the site documentation for the required information about type and location
of the DC distribution.
2. Check the actual distance between terminal block of the MSU and DC distribution.
3. Cut back the wire insulation at the end that is to be connected to the terminal block.
4. Fix both DC wires with straps by using the strain relief clamps at the edge of
EMI Panel.
5. Insert the wires into the terminals. Use a screwdriver for opening the terminal
springs. Check that all wires are in fixed position.
- 48 V
+0V
fixed by straps
32
Fig. 2.23
Fig. 2.24
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.6.3
NOTE
Use only mesh shielded twisted pair or coaxial copper cables.
The maximum cable length between the Iub interface and the link equipment on site
must not exceed 42 metres (140 feet).
The cable shielding must be connected to the relevant ground pins as close as possible
(in order to avoid EMC/RF interfering effects).
2.6.3.1
Fig. 2.25
1.
2.
3.
4.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
33
IMN:NB-440
Installation
Node B
Fig. 2.26
1.
2.
3.
4.
Ground
IUB4_ULB
IUB7_ULA IUB3_DLA
IUB4_ULA
IUB3_ULA
IUB4_DLB
IUB3_ULB
IUB7_ULB IUB3_DLB
Ground
IUB2_DLA
IUB2_ULA
IUB6_ULA IUB0_DLA
IUB1_ULB
IUB0_ULA
upper row
lower row
34
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.6.3.2
Fig. 2.28
For coax cabling with 75 impedance use coaxial cable e.g. 2YCCY 0.4/2.5.
The coaxial cables will be prepared as follows:
1. Fix a 1,0/2,3-female connector for each Iub up- and down-line at the end to be
connected to the OVPTE1CF or IUBCONCSFV1.
2. Connect the prepared cable to the matching connectors.
3. Use a torque spanner for 1,0/2,3 connectors (35 Ncm).
IUB-downlink line no.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
35
IMN:NB-440
Installation
Node B
2.6.3.3
1 2
3 4
5 6
X1
X2
X9
X3
X10
X4
X11
X5
X12
X6
1 2
3 4
5 6
Fig. 2.30
connector / pin
connector / pin
Signal name
X1-1
Iub 0 - ULA
X4-1
Iub 4 - DLA
X1-2
Iub 0 - ULB
X4-2
Iub 4 - DLB
X1-3
Iub 0 - DLA
X4-3
Iub 5 - ULA
X1-4
Iub 0 - DLB
X4-4
Iub 5 - ULB
X1-5
Iub 1 - ULA
X4-5
Iub 5 - DLA
X1-6
Iub 1 - ULB
X4-6
Iub 5 - DLB
X2-1
Iub 1 - DLA
X5-1
Iub 6 - ULA
X2-2
Iub 1 - DLB
X5-2
Iub 6 - ULB
X2-3
Iub 2 - ULA
X5-3
Iub 6 - DLA
X2-4
Iub 2 - ULB
X5-4
Iub 6 - DLB
X2-5
Iub 2 - DLA
X5-5
Iub 7 - ULA
X2-6
Iub 2 - DLB
X5-6
Iub 7 - ULB
X3-1
Iub 3 - ULA
X6-1
Iub 7 - DLA
X3-2
Iub 3 - ULB
X6-2
Iub 7 - DLB
X3-3
Iub 3 - DLA
X6-3
EXTSYNCA
X3-4
Iub 3 - DLB
X6-4
EXTSYNCB
X3-5
Iub 4 - ULA
X6-5
X3-6
Iub 4 - ULB
X6-6
Tab. 2.1
36
Signal name
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
connector / pin
connector / pin
Signal name
X7-1
Iub 0 - ULA
X10-1
Iub 4 - DLA
X7-2
Iub 0 - ULB
X10-2
Iub 4 - DLB
X7-3
Iub 0 - DLA
X10-3
Iub 5 - ULA
X7-4
Iub 0 - DLB
X10-4
Iub 5 - ULB
X7-5
Iub 1 - ULA
X10-5
Iub 5 - DLA
X7-6
Iub 1 - ULB
X10-6
Iub 5 - DLB
X8-1
Iub 1 - DLA
X11-1
Iub 6 - ULA
X8-2
Iub 1 - DLB
X11-2
Iub 6 - ULB
X8-3
Iub 2 - ULA
X11-3
Iub 6 - DLA
X8-4
Iub 2 - ULB
X11-4
Iub 6 - DLB
X8-5
Iub 2 - DLA
X11-5
Iub 7 - ULA
X8-6
Iub 2 - DLB
X11-6
Iub 7 - ULB
X9-1
Iub 3 - ULA
X12-1
Iub 7 - DLA
X9-2
Iub 3 - ULB
X12-2
Iub 7 - DLB
X9-3
Iub 3 - DLA
X12-3
EXTSYNCA
X9-4
Iub 3 - DLB
X12-4
EXTSYNCB
X9-5
Iub 4 - ULA
X12-5
X9-6
Iub 4 - ULB
X12-6
Tab. 2.2
2.6.4
Signal name
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
37
IMN:NB-440
Installation
Node B
X9
X10
Fig. 2.31
12
X2
12
12
X3
X1
X4
12
CAUTION
The signal source of the external alarms (clamping block X1 ...X4) must be a switching
contact (relais, open collector for rack internal alarms will be possible).
It is not allowed to connect a voltage source to the alarm inputs.
Pin no.
connector X1
Alarm No.
connector X2
Alarm No.
connector X3
Alarm No.
connector X4
Alarm No.
2,4,6,8,10,12
GND (ground)
GND (ground)
GND (ground)
GND (ground)
AL_42
AL_36
AL_30
AL_24
AL_43
AL_37
AL_31
AL_25
AL_44
AL_38
AL_32
AL_26
AL_45
AL_39
AL_33
AL_27
AL_46
AL_40
AL_34
AL_28
11
AL_47
AL_41
AL_35
AL_29
Tab. 2.3
The ACTM provides at the connectors X9 and X10 the possibility to switch up to
8 electrical consumers via a relay contact (relays is already integrated on ACTM).
38
CAUTION
The switched current must not exceed 100 mAAC/DC (contact closed) and the maximum
switched voltage is limited to 30 VAC or 30 VDC (contact open). The maximum
switching power is 10 W.
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
Pin no.
Signal name X9
CMD0P
CMD4P
CMD0M
CMD4M
CMD1P
CMD5P
CMD1M
CMD5M
CMD2P
CMD6P
CMD2M
CMD6M
CMD3P
CMD7P
CMD3M
CMD7M
Tab. 2.4
2.6.5
OPEXAL
cable ties
10 symmetric pair
cables
Fig. 2.32
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
39
IMN:NB-440
Installation
Node B
Drill two holes with 6 mm in diameter and min. 35 mm depth as shown in Fig. 2.33.
Insert the dowels.
Attach the MK:OPEXAL to the wall in vertical position and fix it with screws and
washers.
Connect the cables coming from the external alarm sensors at the left screw terminals of the overvoltage protectors.
Connect the symmetric pair cables at the right screw terminals of the overvoltage
protectors.
Attach the ground wire to the yellow / green WAGO terminal (see Fig. 2.34).
Fix all cables with cable ties at the bracket of the MK:OPEXAL..
Route the cables to the ACTM and the ground wire to the PE-plate of the EMI-panel
(see Fig. 2.35).
700 mm
220 mm
Fig. 2.33
40
diameter 6 mm
drill hole depth 35 mm
max. 30 mm
from the rack edge
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
cables from
external alarm sensors
Input side
ground wire
to PE-plate of EMI Panel
Fig. 2.34
Output side
cable tie
ACTM
PE-plate
ground bolt
Fig. 2.35
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
41
IMN:NB-440
Installation
Node B
2.6.6
Fix external alarm cables with cables ties at the stress relieving bracket, so that a
proper electrical contact between the bracket and the cable screens is guaranteed.
Attach the ground wire to the bolt at the PE-plate.
Connect the external alarm cables at the matching WAGO terminals of the ACTM.
Signal name
Pin no. X8
Signal name
AL_1P
AL0_P
AL_GND
AL_GND
DC_SMOKE_PUE
DC_SMOKE_MUE
Tab. 2.5
Pin no. X9
Signal name
Signal name
AL10_P
BB0_BB1
BB0_BB1
AL_GND
Tab. 2.6
SMOKE RDO
X12
X8
X9
X10
18
X21
BB0...BB1
meaning of abbrevations:
RDO: rack door open
SMOKE: smoke sensor
BB0...1: battery fuse 0...1
Fig. 2.36
42
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
AL_GND
10
12
14
16
17
TEMP_SENSE_GND
18
TEMP_SENSE
Tab. 2.7
2.6.7
Signal name
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
43
IMN:NB-440
Installation
Node B
2.6.8
Fig. 2.37
44
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.6.9
Antenna Connections
The NB-440 has to be connected to the transmit/receive antennas. The antenna
configuration and the required cabling are dependent on the conditions found at the site.
For detailed information refer to the site-specific documentation or use the corresponding customer documents.
For installation and service purposes it is useful to know which hardware is connected
to which cell. The numbering, seen from the top of the antenna pole, starts at an
azimuth angle of 0 (north) and rotates clockwise.
The first existing cell whose beam centre line lies at 0 or more is defined as
cell 0 or sector 0. The next one following in the same sense of rotation is cell 1, etc.
In case of an omni cell the cell no. is 0.
0
sector 2
sector angle
directional antenna
pole
sector width 120
sector 0
sector 1
Fig. 2.38
2.6.9.1
Example for cell numbering (top view from the antenna pole)
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
45
IMN:NB-440
Installation
Node B
These jumper cables must be fabricated of 1/2 highly flexible coaxial cable on-site,
if no pre-fabricated cables should be used.
Fabricate the jumper cables in steps as shown in the following figures.
cable knife
open-ended spanners
(jaw opening 21mm and
25 mm)
Fig. 2.39
heatshrink sleeve
fitting ring
cleaning tissue
corrugation nut
connector head
emery paper
Fig. 2.40
46
Measure the distance between the end of the antenna feeder cable and the front
connectors of the combining modules.
Saw the cable to the required length. Do not deform cable outer conductor, when
using too much pressure for sawing !
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2
rotate clockwise
1
Fig. 2.41
Fig. 2.42
heatshrink sleeve
fitting ring
Fig. 2.43
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
47
IMN:NB-440
Installation
Node B
fitting ring
connector head
corrugation nut
Fig. 2.44
20 mm
Fig. 2.45
Fig. 2.46
48
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
heated air
Fig. 2.47
The antenna cables must be routed through the EMI Panel forward to the 7/16 front
connectors of DUAMCOF.
NOTE
Note that being able to close the doors means that the depth of the right angle
connector is not allowed to exceed 45 mm.
max. 45 mm
Fig. 2.48
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
49
IMN:NB-440
Installation
Node B
NOTE
The outer insulation of the antenna cables must be removed for proper ground contact
at the lids of the cable feeding module (see Fig. 2.49).
unscrew
Fig. 2.49
50
NOTE
After the installation of the antenna system is completed, collect the following antenna
cable parameters and document them for the customer:
length and type of all antenna feeder cables
length and type of all antenna jumper cables
The same type of antenna feeder cables and jumper cable should be used within the
same sector.
The length differences between the main and diversity paths within the same sector
should be less than < = 1m. A cable length accuracy < = 1/2 m is recommended.
Information about the cable parameters supplied by subcontractors may be required.
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
2.6.10
Linear-Pol Antennas
TMAF
TMAF
Feeder 1
Fig. 2.50
Cross-Pol Antenna
DTMAF
Feeder 1
Feeder 2
Feeder 2
FDD
FDD
NodeB
NodeB
60.5
to antenna
47
68
78
to Node B
draining pipe
ground screw
175
Fig. 2.51
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
51
IMN:NB-440
Installation
Node B
24
296
Fig. 2.52
77
to Node
1
30
47
68
78
175
Fig. 2.53
52
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
77
to antenna
0
47
30
Fig. 2.54
340
24
Fig. 2.55
Two 7/16 female connectors, located at the bottom of the TMAF (lettered ANT and
Node B) are the interfaces for connections of the feeder cable towards to Node B and
to TX/RX antenna with appropriate antenna jumper cabels 1/2.
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
53
IMN:NB-440
Installation
Node B
The DTMAF provides two 7/16 female connectors at the bottom for the connection with
the Node B (lettered NodeB 0 and NodeB 1) and on the top both 7/16 connectors for
connecting the jumper cables to the antennas (lettered ANT 0 and ANT 1).
NOTE
The TMAF and the DTMAF can be pole-or wall mounted in vertical position only !
Each TMAF / DTMAF shall be grounded to the pole, therefore a grounding wire has to
be prepared for each device on site.
The mounting plate has a screw with a locking washer attached to it and a threaded hole
for connection of the grounding wire (see Fig. 2.51 and Fig. 2.53).
The grounding wire cable lug must have the right size for the M8 ground screw. The
cross section of the ground wire must be not less than 16 mm2.
The other end of the grounding wire should be safely connected to a well grounded point
on the pole.
Care must be taken that the draining pipe (see Fig. 2.51 and Fig. 2.53) is pointed downwards. The draining pipe is factory mounted. If it, for any reason, would be loosened, it
should be tightened again with a sufficient torque wrench, however not exeeding
2.2 Nm.
The draining pipe must never be obstructed or covered with paint which would impede
the venting and draining of the housing.
2.6.10.1
54
NOTE
Pay attention to the thermal dimensional changes of the antenna feeder cables.
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
Fig. 2.56
hose clips
tighten
tighten
Fig. 2.57
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
55
IMN:NB-440
Installation
Node B
to antenna
ground bolt
to NodeB
Fig. 2.58
2.6.10.2
340 mm
278 mm
296 mm
TMAF
175 mm
Fig. 2.59
56
DTMAF
322 mm
130 mm
130 mm
175 mm
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
!
2.6.11
CAUTION
It is absolutely necessary to prepare and connect an adequate grounding cable to the
TMAFs grounding point.
CAUTION
Pay attention to the thermal dimensional changes of the antenna feeder cables.
Fig. 2.60
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
57
IMN:NB-440
Installation
Node B
2.6.12
TX
TX
LPA 0
RF out
TX 0
D RX 0
U
A RX 1
M
C RX 0
O
F RX 1
TX 1
RF out
TRX 0
RX 0
RX 1
RX 0
RX 1
TRX 3
LPA 1
TX
Fig. 2.61
58
TX
CAUTION
To avoid short circuits, do not pack the overlength of system cables in the free space
between the fans of the A-shelf and the EMI-filters of the mains supply unit.
CAUTION
To obtain the minimum bending radius of 35 mm (RG 142) and 3,5 mm
(semi-rigid .86 AI). A bending tool should be used.
Fix the system cables at SMA connectors with a torque wrench set 100 Ncm and at
N-type connectors with a torque wrench set 1,10 Nm.
Terminate all unused connectors of the antenna combiners with 50 Ohm load resistors!
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
The following table provides an overview of the types and functionality of the
prefabricated cables.
connection
code number
length
path
connector
cable
type
C39195-Z80C221
80 mm
TX
C39195-Z80C222
250 mm
TX
C39195-Z80C219
1800 mm TX/
RX
SMA,90,male/
SMA,90,male
semirigid
.86 Al
1800 mm TX/
RX
SMA,90, male/
SMA,90, male
coax
cable,
flexible
Tab. 2.8
S30864X217-A20
The minimum single bending radius of the flexible cables is 20 mm. The minimum
repeated bending radius is 40 mm. The exeptional length of the cables have to be stored
inside the vertical space between the subracks and the inside rack wall.
The horizontal space below each subrack have not to be used to store the extra length
of the system cables or anything else. This space is used as an air inlet for cooling.
Here a routing sketch for the DUAMCOF and LPA left/right hand cabling is given.
LPA left/right hand cabling
C39195-Z80-C221
L
P
A
#0
Fig. 2.62
D
U
A
C
O
F
L
P
A
#0
#1
C39195-Z80-C222
LPA-DUAMCOF cabling
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
59
IMN:NB-440
Installation
Node B
2.7
60
Siemens AG:A50016-G5000-C229-5-7631
NEC Corporation:ND-57356-701(E)-05
Installation
Node B
IMN:NB-440
3 Appendix
3.1
Yes
No
Grounding
Node B connected to ground as described in section Ground and
Power Supply Connections -48V DC
Cable screens of all cables connected to ground at the cable
window of the building
Power Supply
Cross section of power supply cable sufficient
Proper disconnect and overcurrent device installed
power supply connection correspondend to TNS-or TT Network
requirements
Cable window of the installation building equipped with lightning
conductor
Cross section correspondend to cable length
External Alarms
External alarm cables with braided screen
Cable screen contacted to metal lid of cable feeding module
Cable screen contacted to ground at both ends
Overvoltage protection equipment present and correct installed
IuB cables
IuB cables with braided screen
Cable screens connected with EMI panel of rack
Cable screen contacted to ground at both ends
NTPM connector for cable screens correspondend to
EMC requirements
Overvoltage protection equipment present and correct installed
Antenna Cables
Outer conductor of antenna cables connected to ground at
antenna window
Grounding of antenna cables between antenna and antenna window correpondend to grounding guideline
Antenna cable conductor protected against humidity
Cable parameter parameters collected and part of the customer
documentation
Tab. 3.1
Siemens AG:
A50016-G5000-C229-5-7631
NEC Corporation:
ND-57356-701(E)-05
61