Você está na página 1de 2

I N T E R V E N T I O N A L

B R E A S T

S O L U T I O N S

Simply Better.

Innovation in ultrasound-guided breast biopsy

Better access, larger cores and more control. Introducing Celero.


Simply put... its simply better.
Innovation starts with the willingness to listen and the ability to understand. By leveraging the
knowledge and insight of leading physicians, technologists and administrators, we were able
to better understand their challenges and as a result designed a better hand-held breast biopsy
solution Celero. The Celero breast biopsy device delivers both the compassion patients
deserve and the clinical benets you demand.
Celero is the rst vacuum-assisted, spring loaded core biopsy device designed for your use
under ultrasound-guidance. With its 12-gauge needle and 11 trocar tip, you have better
access to areas of interest regardless of tissue type or lesion position. With the Celero
breast biopsy device, you can achieve your goals with fewer samples and larger quality
cores, which means fewer needle insertions and a more compassionate breast biopsy for
your patient. For your ease and convenience, Celero is completely disposable, requires no
capital and is economically supported by reimbursement code 19103.

Clinical Goals Achieved:


Easy access to challenging lesions
Larger tissue samples than other spring loaded core devices
Consistently provides quality tissue samples
Fewer insertions for your patient
Visually conrms aperture location prior to tissue acquisition
Ability to mark biopsy site

LIT553_CeleroSellSheet_3712r1.indd 1

7/9/13 12:55 PM

Better Cores

Better Access

Better Conrmation

Core size more than 2x the size


of other SLC devices*

11 trocar tip provides smooth


penetration to lesion while
eliminating deection

Two ring modes provides exibility


for precise control and verication of
sample area

Better control for challenging


procedures:

Vacuum technology holds tissue in


the aperture ensuring large core
sample

Fewer insertions needed for


accurate diagnosis
Consistent core quality
*Data on le at Hologic, Inc.

- Chest wall
- Axilla
- Implants

Aperture clearly visible prior to


tissue acquisition

Aperture open and ready


for tissue acquisition
14 gauge,
12 gauge, Celero core.
spring loaded core.
More than twice
the tissue.

Hologic offers the following markers to be used with our Celero


ultrasound-guided breast biopsy device. All these deployment
devices are a rigid end-deploy delivery system.
SecurMark for Celero and SecurMark Ultrasound
SecurMark biopsy site markers are
comprised of:
- Ultrasound visible bio-absorbable
suture-like netting, designed to minimize
movement within the biopsy cavity that
surrounds a bio-compatible permanent
marker.
- Two titanium and three stainless steel
shapes available.
SecurMark under ultrasound

Titanium

Stainless steel

SecurMark Biopsy Site Markers

CeleroMark
CeleroMark biopsy site markers
are comprised of bio-compatible
permanent titanium.
Two shapes available.
CeleroMark Biopsy Site Markers

Note: Shapes appear larger than actual size.

Hologic, Inc.
250 Campus Drive
Marlborough, MA 01752
Toll Free: 866.636.8837
Tel: +1.508.263.2900
Fax: +1.508.229.2795

LIT553:RevF (3/13) Hologic 2013. All rights reserved.


Printed in USA. Specications are subject to change without prior notice. Hologic, Celero, CeleroMark,
the Hologic, Celero, and CeleroMark logos are trademarks and/or registered trademarks of Hologic, Inc.
in the United States and other countries.

www.hologic.com

LIT553_CeleroSellSheet_3712r1.indd 2

7/9/13 12:55 PM

Você também pode gostar